Cat. No. 700-HLS (Solid-State Output)

This document provides specifications for a solid-state relay and timer with catalog number 700-HLS. The specifications include details on the control circuit, outputs, power consumption, dielectric withstand voltage, impedance ranges for different input voltages, operating times, environmental operating conditions, construction, terminal markings, certifications, standards, and hazardous location approvals.

Uploaded by

Arif Khan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
66 views1 page

Cat. No. 700-HLS (Solid-State Output)

This document provides specifications for a solid-state relay and timer with catalog number 700-HLS. The specifications include details on the control circuit, outputs, power consumption, dielectric withstand voltage, impedance ranges for different input voltages, operating times, environmental operating conditions, construction, terminal markings, certifications, standards, and hazardous location approvals.

Uploaded by

Arif Khan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Relay and Timer Specifications

Cat. No. 700-HLS… (Solid-state Output)


Min. Control Voltage 80% nominal voltage
Maximum Control Voltage 110% nominal voltage
Control Current 9 mA ±10% (24V) 4 mA ±10% (120/240V)
Control Circuit
Release Voltage 0.4 x nominal voltage (24V), 0.35 x nominal voltage (120/240V)
3200 ohms (24V), 2500 ohms (24V),
Min. Control Circuit Resistance 16k ohms (120V), 12k ohms (120V),
32k ohms (240V) 24k ohms (240V)
Load Voltage Range 0…24V DC 24…240V AC
Max. Repetitive Blocking Voltage 33V 600V
Max. Switching Current (inductive/
2 A DC 1 A AC
Outputs resistive)
On State Voltage Drop @ Max.
<120 mV DC <1V AC
Switching Current
Leakage Current max. 100 μA (@U = 24V)
AC 0.6VA(120V), 1VA(240V)
Power Consumption ±10%
DC 0.2 W 0.3 W
Design Specification/Test Requirements
Pole to Pole (VRMS) 2500V
Dielectric Withstand Voltage
Contact to Coil (VRMS) 2500V
Input Voltage 24V DC 48V DC 120V AC/DC 240V AC/DC 120V LCSC 240V LCSC
Impedance (Ohms) 2K 9K 26 K 58 K 16 K 35 K
Mechanical
Degree of Protection IP20
Input Voltages See Overview/Product Selection

Operating Time at Nominal Voltage at Turn on Time 30 μs (DC only input voltage), 7 ms (AC/DC input voltage)
20 °C (ms) Drop Out Time 350 μs (DC only input voltage), 10 ms (AC/DC input voltage)
Maximum Operating Rate 300 Hz
Environmental
Operating –20…+55 °C
Temperature
Storage –40…+70 °C
Altitude 2000 m (6560 ft)
Construction
Insulating Material Molded High-Dielectric Material
Enclosure Relay IP67
Terminal Markings on Socket In accordance with EN50 0005
Certifications cULus Listed (File No. E14843, Guide NLDX/NLDX7), CE Marked, ABS (American Bureau of Shipping)
Standards UL 508, CSA C22.2 No. 14, EN 61810-1
Class 1, Zn 2, Groups IIC, Ex nC IIC T5 Ta < 55 °C
UL Listed 700-HLT1Z24-EX, 700-HLS1Z24-EX (24V DC supply)
Hazardous Location Approvals (UL 60079-15) 700-HLT1U1-EX, 700-HLS1U1-EX (110V/125V AC/DC supply)
CSA Certified (1) 700-HLT1Z24-EX, 700-HLS1Z24-EX (24V DC supply)
(CAN/CSA 60079-15)
(1) Product shall be installed in an enclosure providing at least IP54 protection. Provisions shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 40%.

54 Rockwell Automation Publication 700-TD552D-EN-P - June 2019