Quick Reference Guide
Delcos 1000
SM 1345
Key to Buttons Access Code
From "Press. & Temp." display:
START Press and hold & buttons
for 5 seconds
Enter Code:
STOP
Main Selection Menu
RESET: Resets Faults/Warnings
Mains Pressure: Network Pressure and
Pressure Settings
UP: Scrolls Up in Menu Routines Note: Not accessible on
pressure switch-controlled
models (L04 & L05)
Operating Times: Running and Loaded Hours
DOWN: Scrolls Down in Menu Routines
Maintenance: Service Times
Operating Mode: Operating Settings
MINUS: Scrolls Left/Decreases Values
Factory Pre-setting: Default Values
RIGHT: Scrolls Right/Increases Values
ENTER: Selects/Confirms Values See overleaf for details
DL067AA CompAir Drucklufttechnik GmbH, Argenthaler Straße 11, D-55469, Simmern/Hunsrück, Germany. 04/2007
Tel: +49 6761 8320 Fax:+49 6761 832409 Email: info@compair.de
Training Enquiries: product.training@compair.com
Delcos 1000 - Main Menu Structure (Examples Only)
Operating times Change of settings
if the settings are to be changed, select the corresponding menu point and press the key.
The setting value will flash and can now be changed with the or keys. This does not
Load hours apply to factory pre-settings, with the exception of the (Starts per hour) settings.
(see "Change coasting time" within the user manual).
Operating hours * Hold down for 5 seconds
Mains pressure Press. & Temp. display Maintenance Operating mode Factory pre-settings
Mains pressure display Remaining time air filter Operating mode Operating pressure
* Aut = Automatic operation
&
cnt = Continuous operation
Fault storage
Startup protection
Pressure band 1, cut-out pressure Remaining time oil filter
Local/remote control
Loc = Local control
Etn = Remote control Shutdown excess. comp. temp.
Pressure band 1, cut-in pressure Remaining time fine separator
Early warning excess. comp. temp.
Automatic re-start
Pressure band 2, cut-out pressure Remaining time oil change
Start-up blockage low temp.
Start delay for deferred startup(s)
Pressure band 2, cut-in pressure Shutdown at - 100 hours
Star/delta changeover time
Limited power failure time
The menu point for the additional
Fault message indicated automatic restart after power failure
(Er1 = latest entry) (PFt) is only displayed if this Max. number of starts per hour
function has been activated. See
The error codes in the right display chapter "additional automatic
Pressure band 2 can be configured can be found in the fault storage restart after power failure" within
via terminal block X2 table (see user manual). the user manual. Soft-stop time
SM 1346
Accessible and Visible on code entry only
Compressor number
Access Code
From Press. & Temp. display :-
Press and hold & buttons for 5 seconds
(display changes to: ) Protocol
Enter code: