LOGIK 9 CONTROLLER
GENERAL INFORMATION
Logik 9 is an industrial electronic control device
suitable for the operation of low-medium size
screw compressors with basic functions.
Thanks to the input for pressure transducer,
settable via software, Logik 9 allows to operate
the compressor also by electromechanical
pressure switch.
Directives and Limits
Conformity to EC and UL 508 regulation
Black auto-extinguishing box in ABS a) according EC: IP64 for the front panel and IP20 for the
other parts; b) according UL: Type 1 and Type 12 for front panel mounting, installation in
pollution degree 2 for the other parts
Working temperature: - 10°C (14°F) ÷ 50°C (122°F) 90% RH (non condensing)
Power supply: 12Vac ± 15% 50 ÷ 60 Hz
LOGIK 9 – Inputs & Outputs
Analog Inputs : Digital Outputs :
• 2 Analog inputs • 5 relay outputs
Digital Inputs : Serial Interface :
• 4 opto isolated digital inputs • RS485 supporting Modbus RTU
LOGIK 9 – Inputs & Outputs
Power supply : Digital Inputs :
• 12 Vac ± 10%
• Input 1 : Emergency Stop Button
Analog Inputs : • Input 2 : Motor Thermal Overload
• Analog input 1 : Temperature Probe • Input 3 : Phase Control Relay
• Analog input 2 : Pressure Transducer • Input 4 : Remote Start/Stop
Unused digital inputs can be configured according to needs
LOGIK 9 – Inputs & Outputs
Power supply : Digital Inputs :
• 12 Vac ± 10%
• Input 1 : Emergency Stop Button
Analog Inputs : • Input 2 : Motor Thermal Overload
• Analog input 1 : Temperature Probe • Input 3 : Phase Control Relay
• Analog input 2 : Pressure Transducer • Input 4 : Remote Start/Stop
Unused digital inputs can be configured according to needs
LOGIK 9 – Inputs & Outputs
Digital Outputs : Alarm Relay (Output 5) :
• Output 1 : Line Contactor Thanks to special software it possible to
• Output 2 : Start Contactor take alarm and warning informations by
• Output 3 : Delta Contactor using just 1 relay.
• Output 4 : Load Selenoid
LOGIK 9 – Alarms
Alarm Method
• Phase Rotation (Digital input)
• Generic Alarm (Digital input)
• High Temperature Alarm (Parameter)
• High Temperature Warning (Parameter)
• Temperature Probe Failure (Connectiviy check)
• Low Temperature (Parameter)
LOGIK 9 – Alarms
Alarm Method
• Power Failure (Measurement)
• Starts/hour (Parameter)
• Security Pressure Switch (Digital Input)
• High Pressure Alarm (Parameter)
• Transducer Failure (Connectivity Check)
• Emergency Stop Button (Digital Input)
LOGIK 9 – Maintenance
Each maintenance timers can be set by • F-A : Air Filter Change
using the parameters • F-O : Oil Filter Change
• F-S : Separator Filter Change
• OIL : Oil Change
• C-H : Check the Compressor
• b-L : Lubricate Bearings
LOGIK 9 – The Control Panel & Visualizations
The logik9 serves the regarding informations
into different groups that user can easily
observe the important informations and
measurements separately.
Group 1 : The working pressure
Group 2 : Pressure measurement unit
Group 3 : The working temperature
Group 4 : This menu visualize the parameter
sub menu code.
LOGIK 9 – The Control Panel & Visualizations
Each icon on the screen informs the user about
current changes of the regarding inputs and
outputs.
- Pressure unit selection Psi / Bar
- Temperature unit selection °F / °C
1: The fan is on icon
2: The load selenoid valve is energized
3: Remote Start / Stop input opens
4: An alarm occured in the system
5: Maintenance timer is elapsed
6: The temperature measurement unit
7: Master / Slave working mode
LOGIK 9 – Password Protection
Logik9 has different password levels regarding
to menu access permissions.
Thanks to this special password protection
design, the risky and important parameters
security is provided.
LOGIK 9 – Communication
Logik9 has 1 RS485 serial communication port that allows to communicate under ;
• Master / Slave Mode
• Multiunit
• Scada Systems
• Cloud Server
• Webserver
LOGIK 9 – Master/Slave Communication
Master / Slave communication functions :
• Balance Hours : Two compressors can be managed to balance the working hours
• Cascade working system with two compressors : By proper parameter settings user can
design cascade system where one compressor capacity is not sufficient to provide
pressurized air.
Logik9 Logik33S Logik26S
RS485 line
Modbus Rtu Protocol
LOGIK 9 – Multiunit Communication
Multiunit Communication Functions:
• Balance Hours : the working hours can be balanced
• Priority : Its possible to assing to compressor a priority
• Smart Mode : According to air consumption, the multiunit system selects the energy
saving combination with the compressor capacities.
Logik200 Multiunit Controller
RS232-RS485
Converter
RS485 line
Modbus Rtu Protocol
Logik9 Logik33S Logik26S
Up to 12 units can be controlled
LOGIK 9 – Ethernet Serial Gateway Functions
Ethernet Serial Gateway:
• Embedded webserver mode: the compressor plant monitoring
• Cloud based mode : the compressor plant monitoring by using internet connection
• Modbus RTU -> Modbus TCP converter
Serial Ethernet Interface TCP/IP – WebServer Interface
Modbus RTU / Modbus TCP
RS485 line
Modbus Rtu Protocol Cloud – Server
TCP/IP – WebServer Interface
Up to 12 units can be connected