A2000 Multifunctional Power Meter: Applications Applicable Regulations and Standards
A2000 Multifunctional Power Meter: Applications Applicable Regulations and Standards
3-348-980-03
Multifunctional Power Meter                                                                                                                       8/3.02
GOSSEN-METRAWATT GMBH
A2000
Multifunctional Power Meter
Data Storage                                                                                      Representation of Values for Power and Power Factor According to the
Up to 12 measured values can be selected for storage to mem-                                      Selected Parameters Configuration
ory. The measuring instrument acquires these measured values
once every 300 ms and stores them first to intermediate memory.                                   DIN = calculation of reactive power per DIN 40110
These values are then averaged in accordance with the selected                                          without + or – sign
sampling rate and are stored to permanent memory as mean val-
ues. The sampling rate is adjustable from 300 ms to max. 30 min-
utes. Recording is triggered by means of internally selected limit                                                 Q=           S2 – P2
values. The duration of the recording can be set within a range of                                                                                         0
1 minute to 4 days. Several events can thus be stored to memory,                                                      PF = cap                                          PF = ind
one after the other. The trigger level which starts the recording                                                                                P=– P=+
                                                                                                                                                 Q=+ Q=+
can be set to either 0%, 25%, 50% or 75% for the duration of any
given recording. This provides the user with an overview of the                                                                     EP–            2. Q 1. Q            EP+
pre-history of the event which triggered recording, including time                                                                  EQ–                                 EQ+
                                                                                                                      1                                                        1
and date.                                                                                                                           EP–                                 EP+
                                                                                                                                                   3. Q 4. Q
Continuous recording is also possible.                                                                                              EQ–                                 EQ+
The memory has a capacity for up to 63,000 values. The maxi-                                                                                     P=– P=+
mum possible duration of a recording depends upon the number                                                                                     Q=+ Q=+
                                                                                                                       PF = ind                                         PF = cap
of recorded measured values (1 to 12), and the sampling rate at
which they are to be recorded (0.3 s to 30 min).                                                                                                           0
                                                                       RS-232                                                                              0
           L1                  Parameters
    Vol-
    tage
                                Memory                                 RS-485                                         PF = ind                                          PF = ind
                                              CPU
    Inputs L2                                16 Bit
                                                                                                                                                P=– P=+
           L3                       ADC                                LON                                                                      Q=+ Q=+
                           Mux     ±12 Bit                             (alternative to RS-485
           N                                                           and Profibus-DP)                                             EP–                                 EP+
                                                                                                                                                   2. Q 1. Q
    Cur-   I1                                                          Profibus-DP                                                  EQ+                                 EQ+
                                                                       (alternative to RS-485                        1                                                         1
    rent   I2                                                                                                                       EP–                                 EP+
    Inputs                                                             and LON)                                                                    3. Q 4. Q
           I3                                                                                                                       EQ–                                 EQ–
                                                                                                                                                           0
                                                                                 Limit                                PF = 1.0                                          PF = ind
                                                                                 Values                                                         P=– P=+
                                                                                                                                                Q=0 Q=+
                                                                                                                                    EP–            2. Q 1. Q            EP+
                                                                                                                                    EQ+                                 EQ+
                                                                                                                     1                                                         1
                                                                                                                                    EP–                                 EP+
                                                                                                                                                   3. Q 4. Q
                                                                                                                                    EQ–                                 EQ–
                                                                                                                                                P=– P=+
                                                                                                                                                Q=0 Q=–
Figure 1 Schematic Diagram                                                                                             PF = 1.0                                         PF = cap
2                                                                                                                                                                       GOSSEN-METRAWATT GMBH
                                                                                                A2000
                                                                           Multifunctional Power Meter
Profibus DP
In the Profibus DP version the serial interface is used only for the
Profibus. All measurement data, except for values stored to the
data logger, can be read out via the bus link. Transmission speeds
GOSSEN-METRAWATT GMBH                                                                                                                      3
A2000
Multifunctional Power Meter
Outputs                                                               Voltage                      secondary phase conductor
Limit Value Monitoring          – Monitored measured                                               voltage at the transformer 500 V
                                   values (sources)                                                primary phase conductor
                                – Min-max characteristics                                          voltage same as secondary
                                – Hysteresis                                                       (= ratio 1:1)
                                – Alarm message storage, on/off       Synchronizing Pulse          internal, mean value over 15 min.
                                – Limit value
2 or 4 Analog Outputs           – Measured values which               Outputs
                                   influence the analog outputs       Limit Value 1                Measured value:         IL1
                                – Output range 4 ... 20 mA,                                        set to:                5A
                                   0 ... 20 mA, ± 20 mA,                                           No hysteresis
                                   0 ... 10 V, 2 ... 10 V or ± 10 V                                Relay closes when exceeded
                                – Analog range with lower and                                      No storage of alarm messages
                                   upper rang values (indepen-        Limit Value 2                Measured value:        U L1
                                   dent of measuring range)                                        set to:                240 V
Pulse Outputs                   – Export, Import                                                   No hysteresis
for Active or Reactive Energy   – Overall energy or energy                                         Relay closes when exceeded
                                   from the individual phase                                       No storage of alarm messages
                                   conductors                         Analog Output 1              Meas. value:      Overall active
                                – Active or reactive energy                                                          power
                                – Pulse rate:                                                      Range:            Import
                                   1 ... 1000 pulses per kWh                                                         0 ... 2000 W
                                   in steps of 1                                                   Output Value:     4 ... 20 mA
                                   1000 ... 5000 pulses per kWh
                                                                      Analog Output 2              Meas. value:      Overall
                                   in steps of 10
                                                                                                                     reactive power
                                The same pulse rates can be                                        Range:            Import
                                used for MWh as well.                                                                0 ... 1000 Var
Serial Interfaces               Either GMC device bus,                                             Output Value:     4 ... 20 mA
                                EN 60870 or Modbus RTU                Analog Output 3 (optional)   Meas. value:      I L2
                                protocol                                                           Range             0 ... 5 A
                                                                                                   Output Value:     4 ... 20 mA
                                Attention: RS 232 and RS 485
                                                                      Analog Output 4 (optional)   Meas. value:      U L2
                                use the same protocol.
                                                                                                   Range:            0 ... 250 V
                                                                                                   Output Value:     4 ... 20 mA
                                Addresses with values ranging
                                from 0 to 254                         Pulse Output 1 (optional)    Meas. value:     overall system
                                Baud rate: 1200, 2400, 4800,                                       Active Energy Import
                                9600 or 19,200                                                     10 pulses per kWh
                                Parity: even, odd, none or space      Pulse Output 2 (optional)    Meas. value:     overall system
                                                                                                   Active Energy Export
The measuring instrument is configured with the following                                          10 pulses per kWh
parameters at the factory:
All parameters can be subsequently changed by the user.               Serial Interfaces
The encoding switch for securing selected parameters against          Address                      250
change is set at the factory to allow for parameter changes.          Baud Rate                    9600
                                                                      Protocol                     GMC device bus
Type of Electrical System                                             Parity                       even
Configuration                   4-wire unbalanced
                                (The energy meters display
                                active and reactive energy for
                                phases L1, L2 and L3, as well
                                as for the overall system.)
Inputs
Current                         second. transformer current 5 A
                                primary current same as
                                secondary (= ratio 1:1)
4                                                                                                          GOSSEN-METRAWATT GMBH
                                                                                        A2000
                                                                   Multifunctional Power Meter
GOSSEN-METRAWATT GMBH                                                                                                               5
A2000
Multifunctional Power Meter
Terminal Assignments                                                                                 Variants with RS 232 and RS 485 Serial Interface, or with LON and RS 232
                                                                                                                                                                                                                  13 14 15
Current Inputs
                                                                                                                                                                                                                   N 115V 230V
             L1                    k            l                                                         Relay 1 Relay 2             I1       I2         I3       N L1 L2 L3
                                                                                                                                                                                                                 Power supply
             N                                                                                                                    k l      k l         k l                                                       max. 15 VA
51 52 53 55 56 57 1 3 4 6 7 9 11 2 5 8 13 14 15
1 3 4 6 7 9 11 2 5 8
L2
L1 k l 46 45 44 43 42 41 38 37 35 33 31 24 23 22 21 20
                                                                                                                           B A
                                                                                                                           LON
                                                                                                                   RxD                              A1 A2 A3 A4          Sync.-      S01 +
                                                                                                                TxD    C B A                                            Input          S02
                                       1 3 4 6 7 9                               2 5 8                                                              Analog
                                                                                                             RS-232 RS-485                          Output                            Pulse
                                                                                                                                                                                      Output
             RELAY 1 RELAY 2           I1               I2           I3        N L1 L2 L3   Power         Please observe permissible feature combinations when ordering.
                                                                                            supply
                                                                                                           51 52 53   55 56 57    1    3   4    6     7        9   11     2      5    8   13 14 15
                 RELAY 1 RELAY 2       I1               I2           I3        N L1 L2 L3   Power
                                                                                            supply
L2
L1 k l
1 3 2 5 8 46 45 44 24 23 22 21 20
6                                                                                                                                                                                                    GOSSEN-METRAWATT GMBH
                                                                                             A2000
                                                                        Multifunctional Power Meter
GOSSEN-METRAWATT GMBH                                                                                                                  7
A2000
Multifunctional Power Meter
Order Information
 Designation                                                                                                                    Configuration Options
                                                                                                                               Article Number / Feature
 A2000 Multifunctional Power Meter                                                                             A2000                   A2000                   A2000
 Serial Interface                             with RS-232 and RS-485                                             L0                       –                        –
                                              with LON and RS-232                                                 –                      L1                        –
                                              with Profibus-DP and RS-232                                         –                       –                        L2
 Analog Outputs                               2 analog outputs                                                   A0                      A0                        –
                                              4 analog outputs                                                  A1 1)                     –                        –
                                              without analog output                                               –                       –                        A2
 Data Logger                                  without data logger                                                R0                      R0                        R0
                                              with data logger                                                 R1 1) 2)                 R1 1)                     R1 1)
 Pulse Output / Synchronizing Input           without pulse output and without synchronizing input               P0                       –                        P0
                                              2 pulse outputs and 1 synchronizing input                          P1                      P1                        P1
 Supply Voltage                                230 / 115 V                                                       H0                      H0                        H0
                                               20 ¼ 69 V      / 20 ¼ 72 V                                        H1                      H1                        H1
                                               73 ¼ 264 V        / 73 ¼ 276 V                                    H2                      H2                        H2
 Manufacturer’s Certificate /                 without certificate                                                U0                      U0                        U0
 Test Report                                  with certificate and test report                                   U1                      U1                        U1
 Operating Instructions                       German (standard)                                                  W0                      W0                       W0
                                              English                                                            W1                      W1                       W1
                                              French                                                             W2                      W2                       W2
1)
     only in combination with Feature P1
2)   only in combination with Feature A1
Accessories
 Designation                                                                                                                                          Article Number
 METRAwinâ10/A2000        with adapter – software for the transmission of measured values and for instrument configuration                                Z305A
 Interface cable RS-232, approx. 2 m long                                                                                                           GTZ3241000R0001
Standard Units
The following measuring instruments can be shipped as standard units. Only the article number needs to be indicated.
 Designation                                                                                                              Instrument and Features Combination Article Number
 A2000       with 230 V / 115 V supply voltage, with 2 analog outputs, with RS-232 and RS-485 interfaces,                    A2000 H0 A0 P0 R0 L0 U0 W0           A2000-V001
             with operating instructions in German
 A2000       with 230 V / 115 V supply voltage, with 4 analog outputs, with 2 pulse outputs and                              A2000 H0 A1 P1 R0 L0 U0 W0           A2000-V002
             1 synchronizing input, with RS-232 and RS-485 interfaces, with operating instructions in German
 A2000       with 230 V / 115 V supply voltage, with 4 analog outputs, with 2 pulse outputs and                              A2000 H0 A1 P1 R1 L0 U0 W0           A2000-V003
             1 synchronizing input, with data logger, with RS-232 and RS-485 interfaces,
             with operating instructions in German
 A2000       with 230 V / 115 V supply voltage, with 2 analog outputs, with 2 pulse outputs and                              A2000 H0 A0 P1 R0 L1 U0 W0           A2000-V004
             1 synchronizing input, with LON and RS-232 interfaces, with operating instructions in German
 A2000       with 230 V / 115 V supply voltage, with 2 pulse outputs and 1 synchronizing input,                              A2000 H0 A2 P1 R0 L2 U0 W0           A2000-V005
             with Profibus-DP and RS-232, with operating instructions in German
GOSSEN-METRAWATT GMBH
Thomas-Mann-Str. 16-20
90471 Nuremberg, Germany
Phone +49 911 8602-0
Fax       +49 911 8602-669
e-mail: info@gmc-instruments.com
http://www.gmc-instruments.com