MODEL 813
3/4" Universal Digital Flowmeter
INSTRUCTION MANUAL
INTRODUCTION
The 813 positive displacement flowmeter has
incorporated the oval rotor principal into its design.
This has proven to be a highly reliable and highly
accurate method of measuring flow, providing
exceptional repeatability and high accuracy.
The 813 meter can be connected to an oil dispensing
nozzle or can be installed and used as an in line meter.
Please read and retain this instruction manual to assist
you in the operation and maintenance of this quality
product.
GENERAL INFORMATION
This manual assists you in operating and maintaining your
new positive displacement flowmeter. The information
contained will help you ensure many years of dependable
INSTALLATION
performance and trouble free operation. 1) Do not over tighten connections.
Please take a few moments to read through this manual METER OPERATION
before installing and operating your new meter. If you TOTAL BUTTON
experience problems with this product, refer to the
Maintenance and Trouble Shooting sections of this manual. Each press of the TOTAL button will allow you to scroll
If you require further assistance please contact your local through the meter options
Lincoln Distributor, or Authorised Lincoln Service Center.
Resetable Batch Total
Non Resetable Accumulative Total
IMPORTANT INFORMATION RESET BUTTON
The RESET button allows you to reset the Batch Total.
Lincoln recommends, that if you are using your meter as an SLEEP
in-line application you should install a filter before the inlet
of the meter. Contact your local Lincoln distributor for If NO flow goes through the meter for 60 seconds the
further details. display will go into sleep mode (Blank). The display will
automatically wake if the buttons are pressed or flow
occurrs.
CHANGE UNITS (e,g: ltr, gal, qrt)
1) Press and hold down RESET for 5 seconds until
2) Press Reset to scroll through the settings “ltr, gal,
3) Press and hold down RESET until “Program”
4) Press “RESET” for five seconds to return the meter
AUG—2009 Form 403944 Section - F22 Page - 34
SLEEP MODE 2) Lightly grease the o’ring (3) and place it on the meter
body.
If NO flow goes through the meter for 60 seconds the
display will go into sleep mode (Blank). The display will 3) Clean the meter cover plate (2) and place it on the body.
automatically wake if the buttons are pressed or flow Take care not to damage the o’ring (3).
occurs. The Rotor with Magnets
BATTERY REPLACEMENT
All data will be saved when the batteries are removed.
Note: Replace the batteries as soon as the
battery indicator on the LCD is displayed + - (fig 2)
1) Remove the plastic protector shroud from the meter body 4) Install the 8 screws (1) and tighten in a diagonal pattern
(fig 1). to 2nm (1.5 ft.lb). Visual check the cap has been pulled
down evenly.
2) Remove the battery cover.
5) Test the meter by turning the rotors with a finger or by
3) Replace the 2 x (AAA) Alkaline batteries. (Refer to the
applying low air pressure (No more than a good breath) to
front of the meter for correct battery orientation).
the inlet port of the meter. This will confirm the meter is
4) Replace the battery cover and re-fit the plastic shroud. operating correctly.
Note: Only use Alkaline batteries. PARTS DIAGRAM
Protector Shroud
Not included
(fig 1)
3
magnets
CAUTION 2
Ensure the fluid supply to the meter is disconnected
and the line pressure is released before disassembly.
METER DISASSEMBLY
1
Note: The electronic computer module is non-repairable.
The meter will need to be replaced if found to be damaged
or faulty.
1) Remove the 8 x socket head screws (1) from the meter
cover.
2) Remove the meter cover (2) and o’ring (3).
3) Remove both rotors (4). PARTS LIST
4) Clean and inspect all parts. Replace any suspect, worn
or damaged components. 3 ROTOR SET 2
2 O-RING 1
METER REASSEMBLY 1 SCREW 8
NOTE: Ensure the rotor with the magnets is assembled on
the same side to the batteries. The magnets in the rotor
4 276025 BATTERY COVER KIT 1
must face towards the electronic display.
1) Replace both rotors (4) so as they are at 90O to each 276026 PROTECTOR SHROUD KIT BLACK* 1
other (see fig 2). Check the rotor rotation by turning either
of the rotors. If the rotors are not in mesh correctly or do not
* Protector Shroud kit not included.
rotate freely remove one of the rotors and replace it
correctly at 90 degrees to the other rotor. Re-check the
operation of the rotors.
Form 403944 Page Number - 2
TROUBLE SHOOTING GUIDE
TROUBLE CAUSE REMEDY
a) Remove rotors and remove any dirt and
No fluid passing through the meter. a) Dirt particles jamming the rotors. contamination.
The meter is not registering a) Flat battery. a) Replace battery.
fluid output. b) Check magnets and replace rotors if
b) No signal from rotor or the magnet. required.
c) Damaged computer (reed switch
unit). c) Replace meter.
a) Flowrate outside recommended a) Adjust flow rate to within 0.8 to 21.1
Meter not accurate. Flowrate. GPM.
SPECIFICATIONS
Accuracy +/- 0.5% of Reading
Type Oval Gear
Flowrate 0.8 to 21.1 GPM
Maximum Pressure 1500 psi
Suitable for use with: Engine Oil, Diesel Oil, Automatic Transmission Fluid (Maximum Viscosity SAE 140),
Ethelene Glycol Based Anti-Freeze/Anti-Boil mixture (Max 50% water)
Wetter Materials Acetal, Aluminum, Steel, Nitrile Rubber
Battery Type 2 x AAA Alkaline
Resettable Totalizer 99999.9 (gal or ltr)
Non-Resettable Totalizer 999999 (lgal or ltr)
Connections 3/4 NPT
Maximum Temperature 131° F (55° C)
Minimum Temperature 23° F (-5° C)
Page Number - 3 Form 403944
Lincoln Industrial Standard Warranty
LIMITED WARRANTY
Lincoln warrants the equipment manufactured and supplied by Lincoln to be free from defects in material and workmanship for a period of
one (1) year following the date of purchase, excluding therefrom any special, extended, or limited warranty published by Lincoln. If equip-
ment is determined to be defective during this warranty period, it will be repaired or replaced, within Lincoln's sole discretion, without charge.
This warranty is conditioned upon the determination of a Lincoln authorized representative that the equipment is defective. To obtain repair
or replacement, you must ship the equipment, transportation charges prepaid, with proof of purchase to a Lincoln Authorized Warranty and
Service Center within the warranty period.
This warranty is extended to the original retail purchaser only. This warranty does not apply to equipment damaged from accident, over-
load, abuse, misuse, negligence, faulty installation or abrasive or corrosive material, equipment that has been altered, or equipment repaired
by anyone not authorized by Lincoln. This warranty applies only to equipment installed, operated and maintained in strict accordance with
the written specifications and recommendations provided by Lincoln or its authorized field personnel.
THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT
LIMITED TO, THE WARRANTY OF MERCHANTIBILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
In no event shall Lincoln be liable for incidental or consequential damages. Lincoln's liability for any claim for loss or damages arising out of
the sale, resale or use of any Lincoln equipment shall in no event exceed the purchase price. Some jurisdictions do not allow the exclusion
or limitation of incidental or consequential damages, therefore the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights. You may also have other rights that vary by jurisdiction.
Customers not located in the Western Hemisphere or East Asia: Please contact Lincoln GmbH & Co. KG, Walldorf, Germany, for your war-
ranty rights.
Lincoln Industrial Special Limited Warranties
SPECIAL LIMITED 2 YEAR WARRANTY-
SL-V Series, Single Injectors-85772, 85782, and Replacement Injectors-85771, 85781
Lincoln warrants the SL-V Injector series to be free from defects in material and workmanship for two (2) years following the date of pur-
chase. If an injector model (single or replacement) is determined to be defective by Lincoln, in its sole discretion, during this warranty period,
it will be repaired or replaced, at Lincoln's discretion, without charge.
SPECIAL LIMITED 5 YEAR WARRANTY-
Series 20, 25, 40 Bare Pumps, PMV Bare Pumps, Heavy Duty and 94000 Series Bare Reels
Lincoln warrants series 20, 25, 40 bare pumps, PMV bare pumps, Heavy Duty (82206), Mini Bench (81133, 81323), and 94000 LFR series
(94100, 94300, 94500) bare reels to be free from defects in material and workmanship for five (5) years following the date of purchase. If
equipment is determined by Lincoln, in its sole discretion, to be defective during the first year of the warranty period, it will be repaired or
replaced at Lincoln's discretion, without charge. In years two (2) and three (3), the warranty on this equipment is limited to repair with Lincoln
paying parts and labor only. In years four (4) and five (5), the warranty on this equipment is limited to repair with Lincoln paying for parts
only.
SPECIAL LIMITED 5 YEAR WARRANTY-
LFM Series Oil Meters (Lincoln Fluid Meter), LFV (Lincoln Fluid Valves), AOD (Air-Operated Diaphragm Pumps)-
Lincoln warrants the LFM meter series (908/912 series), the Lincoln Fluid valve (708/712 series), our Universal Inline Digital Meters (812/813
series), and our AOD Pump offering to be free from defects in material and workmanship for five (5) years following the date of purchase. If
either is determined to be defective by Lincoln, in its sole discretion, during the warranty period, they will be repaired or replaced, at Lin-
coln’s discretion, without charge.
Lincoln Industrial Contact Information
To find Lincoln Industrial’s Nearest Service Center call the following number, you may also use our website
Customer Service 314-679-4200
Website www.lincolnindustrial.com
Americas: Europe /Africa/Middle East Asia/Pacific: © Copyright Lincoln Industrial
One Lincoln Way Lincoln GmbH 51 Changi Business Park Corporation 2009
St. Louis, MO 63120-1578 Heinrich-Hertz-Str. 2-8 Central 2 Printed in USA
#09-06 The Signature
USA 69190 Walldorf - Germany
Singapore 486066
Phone +1.314.679.4200 Phone/Fax +49.6227.33-0/-259 Web site:
Phone +65.6588.0188
Fax +1.800.424.5359 www.lincolnindustrial.de Fax +65.6588.3438 www.lincolnindustrial.com
Form 403944 Page Number - 4