Torqshift 6/6R140: Technical Bulletin #1601
Torqshift 6/6R140: Technical Bulletin #1601
Torqshift 6/6R140
High Pitch Noise/Pump Whine
If you have a high pitch noise when the engine is running there are a few things to check.
1. Check line pressure with gauge. Is the pressure gauge smooth?
If yes, the pressure regulator system is in good shape and no air is entering the system.
If no, inspect for cracked filer or poor seal. A cross leak or place for air to be sucked into system.
Ford 6R140 transmission has no pump bushing. Ford now uses a bearing like some of the Mercedes
transmission. This bearing is also failing with low miles as seen in figure 1. Inspect the bearing for pit-
ting and wear marks. At the time of this bulletin the bearing is only sold as part of the complete pump.
                                                                                            Figure 1
Copyright © 2014 ATRA All Rights Reserved                                                     JW • Page 1 of 1
                                                                               Technical Bulletin #1602
                                                           Transmission:                Jeep RE
                                                                 Subject:               Electrical Circuit Test
                                                             Application:               Jeep
                                                              Issue Date:               April, 2014
Jeep RE
Electrical Circuit TestElectrical Circuit Test
                                     1993 ½ To 1995 Jeep RE Transmission Circuit Test
                                                                          Typical Wire Diagram
                                                                  (Wire Colors May Vary Per Model Year All Circuits
                                                                          Should Identified By Pin Number)
                                                                                                                                     Code List:
                                                                                                                                     21 = Governor Press.
                                                                                                                                     22 = O/D (3-4) Sol.
                  TRANSMISSION
                    CONTROL
                                                                                                                                     23 = TCC (lockup)
                     MODULE
                   (REAR OF I/P LEFT
                 OF STEERING COLUMN)                                                    HOT ST/RUN    HOT AT ALL TIMES
                                                                                    FUSE
                                        C1 (E1 1995)                               BLOCK    FUSE          FUSE          FUSE
                                                                                              0             9             8
                                           C8 (E8 1995)                                      16A           40A           20A
                       FUSED B (+)
                                            C9 (E9 1995)
                  FUSED IGN (ST/RUN)
                                           (F8 1995)                                                                                             6       5
                       FUSED B (+)                                                                                                           7               4
                                           (D8 Mid 1993 & 1994)                                                                                  8
                                                                                                                                             1               3
                                           D12 (F12 1995                                                                                             2
                        GROUND
SOLENOIDS
                                                                                                                        Code List:
                                                      QUICK TEST FOR ONE SOLENOID                                       21 = Governor Press.
                                                                                                                        22 = O/D (3-4) Sol.
      TRANSMISSION                                    CODE SET & RELAY CHECKS OK                                        23 = TCC (lockup)
        CONTROL
         MODULE
       (REAR OF I/P LEFT
     OF STEERING COLUMN)                                                   HOT ST/RUN    HOT AT ALL TIMES
                                                                       FUSE
                           C1 (E1 1995)                               BLOCK    FUSE          FUSE          FUSE
                                                                                 0             9             8
                              C8 (E8 1995)                                      16A           40A           20A
           FUSED B (+)
                               C9 (E9 1995)
      FUSED IGN (ST/RUN)
                              (F8 1995)
           FUSED B (+)
                              (D8 Mid 1993 & 1994)
                                     +
                                                                               1                      5             6          7
                            BATTERY
                                                                            TRANS                  VARIABLE         O/D        TCC
                                                                            CTRL RLY                FORCE         SOLENOID   SOLENOID
                                                                            OUTPUT                SOLENOID
              (Pin ID Changes 1995                                                               (GOVERNOR)
Face View
   C16                                                        C1                                                                       6       5
   D16                                                        D1                                                                   7
                                                                                                                                       8
                                                                                                                                                   4
                                                                                                                                   1               3
                                                                                                                                           2
       POWERTRAIN
        CONTROL
         MODULE
           (RIGHT SIDE OF
            SAFETY WALL)
                                                                               ACC    START
                                                      AUTOMATIC
                             C1                       SHUTDOWN
                             2                                                  OFF RUN
                                                        RELAY
      FUSED IGN (ST/RUN)
                                                                          IGNITION
                                                                           SWITCH
                             22
              FUSED B (+)
                             31
              GROUND
                             32
              GROUND
                        SOLENOIDS                                     1                   5             6           7
                                                                                                                             Case Connector
                                                                      1                   5             6           7
                O/D         TCC     GOV.
                SOL.        SOL.    SOL.
                                                                                                                                    DISCONNECT
                                                                                                                                   TRANSMISSION
                                                                                                                                    CONNECTOR
P0748 = Governor Press. CODE SET & RELAY CHECKS OK (Model Dependent)
       POWERTRAIN
        CONTROL
         MODULE
           (RIGHT SIDE OF
            SAFETY WALL)
                                                                                  ACC    START
                                                      AUTOMATIC
                            C1                        SHUTDOWN
                            2                                                      OFF RUN
                                                        RELAY
      FUSED IGN (ST/RUN)
                                                                             IGNITION
                                                                              SWITCH
                            22
              FUSED B (+)
                            31
              GROUND
                            32
                                                       CUT WIRE
              GROUND
                                                       CLOSE TO
                                                         PCM
                            8
            VAR SOL CTRL
                            11
            TCC SOL CTRL
            O/D SOL CTRL
                            21
                                                                                         SOLENOIDS
                                                                                        O/D         TCC
                            30                                                                                      JUMP 12 VOLTS
       TRANS RELAY CTR
                            C2                                                                                          WITH A
                                                                                                                      FUSED LINK
                                                                                                                     TO ONE PIN ON
                                                                                                                    A KNOWN GOOD
                                                                                                                       SOLENOID
                                                                                                                   JUMP THE OTHER
                                                                                                                    PIN TO THE CUT
                                                                                                                  WIRE ON THE PCM C2
                                                                                                                      CONNECTOR
                                            +
                                                       Fusible
                                                        Link
                                                                         1                   5             6             7
                                       +                               TRANS
                                                                      CTRL RLY
                                                                                        VARIABLE
                                                                                         FORCE
                                                                                                        O/D
                                                                                                      SOLENOID
                                                                                                                   TCC
                                                                                                                 SOLENOID
                                 BATTERY                               OUTPUT           SOLENOID      CONTROL    CONTROL
                                                                                        CONTROL
                       C1                            C2                          TRANSMISSION ASSEMBLY
                      BLACK                         WHITE
                                     Wire Side                                                                                          Face View
       1                              11    1                          11
      12                              21   12                          21        O/D & TCC Solenoid = 25-40                                 6       5
                                                                                 ohms / 0.48 - 0.30 amps                                7               4
                                                                                                                                            8
      22                              32   22                          32        Governor Solenoid = 3-5 ohms                           1               3
                                                                                                                                                2
                                                                                 / 4 - 2.4 amps
Case Connector
                                  HOT ST/RUN
                                                                FUSE               FUSE                            TRANS
                                                                  9                  M                             RELAY
                                      FUSE        JUNCTION       16A                16A
                                        9
                                       16A
                                                   BLOCK
         POWERTRAIN
          CONTROL                                                    JOINT
                                                                   CONNECTOR
           MODULE                                                      2
                                                                                                                                   S115
          (RIGHT SIDE OF                                                                                                                        GENERATOR
           SAFETY WALL)
                            C1
                            2                                                                                              2001 & Up No Relay
      FUSED IGN (ST/RUN)                                                                                                     May Have IPM
                                                                                                                              INTERGRATED
             FUSED B (+)
                            22                                                                                                   POWER
                                                                                                                                 MODULE
                            31
              GROUND
                            32
              GROUND
                             8
            VAR SOL CTRL
            TCC SOL CTRL
                             11                                                               CONNECT
            O/D SOL CTRL
                             21
                                                                                             KNOWN GOOD                                Face View
                             30
         TRANS RELAY CTR                                                                    SOLENOIDS TO
                            C2
                                                                                            HARNESS FROM                                    6       5
                                                                                                PCM                                     7               4
                                                                                                                                            8
             GENERATOR       25                                                                                                         1               3
              OUTPUT                                                                                                                            2
                            C3
                                                                                                                                 Case Connector
                       SOLENOIDS                                               1              5             6          7
                                                                               1              5             6          7
               O/D         TCC      GOV.
               SOL.        SOL.     SOL.
                                                                                                                                       DISCONNECT
                                                                                                                                      TRANSMISSION
                                                                                                                                       CONNECTOR
                   WHITE                                 GREY
                                    Wire Side                                        TRANSMISSION ASSEMBLY
                                HOT ST/RUN
                                                                FUSE                  FUSE                            TRANS
                                                                  9                     M                             RELAY
                                     FUSE        JUNCTION        16A                   16A
                                       9
                                      16A
                                                  BLOCK
         POWERTRAIN
          CONTROL                                                       JOINT
                                                                      CONNECTOR
           MODULE                                                         2
                                                                                                                                         S115
          (RIGHT SIDE OF                                                                                                                               GENERATOR
           SAFETY WALL)
                           C1
                           2
      FUSED IGN (ST/RUN)
                                                                                                                              2001 & Up No Relay
                                                                                                                                May Have IPM
                           22
             FUSED B (+)                                                                                                         INTERGRATED
                           31                                                                                                       POWER
              GROUND
                           32
                                                            CUT WIRE                                                                MODULE
              GROUND
                                                            CLOSE TO
                                                              PCM
                           8
            VAR SOL CTRL
                           11
            TCC SOL CTRL
            O/D SOL CTRL
                           21
                           30                                                                SOLENOIDS
         TRANS RELAY CTR
                           C2
                                                                                             O/D         TCC             JUMP 12 VOLTS
              GENERATOR
                           25                                                                                                WITH A
               OUTPUT      C3                                                                                              FUSED LINK
                                                                                                                          TO ONE PIN ON
                                                                                                                         A KNOWN GOOD
                                                                                                                            SOLENOID
                                                                                                                        JUMP THE OTHER
                                                                                                                         PIN TO THE CUT
                                                                                                                       WIRE ON THE PCM C2
                                                                                                                           CONNECTOR
                                                 +
                                                            Fusible
                                                             Link
                                                                                  1              5             6          7
                                        +
                                                                             TRANS           VARIABLE        O/D        TCC
                                BATTERY                                     CTRL RLY          FORCE        SOLENOID   SOLENOID
                                                                             OUTPUT          SOLENOID      CONTROL    CONTROL
                                                                                             CONTROL
                    C2                                   C3                             TRANSMISSION ASSEMBLY
                   WHITE                                GREY
                                  Wire Side                                                                                              Face View
Case Connector
                2005 & Up
                (TTVA C1)
                                                                                                                                                 85
                             C1
                                                                                                                                                 86
                                                                                                                         30 87
                             14
            VAR SOL CTRL
                             25
                                                                                                                            Face View
            TCC SOL CTRL
                             15
            O/D SOL CTRL
                             31
      TRANS RELAY CTR
                             C2                                                                                                      6       5
                                                                                                                                 7               4
                                                                                                                                     8
                                                                                                                                 1               3
                                                                                                                                         2
                                                                                                                          Case Connector
                       SOLENOIDS                                        1                5             6         7
                                                                        1                5             6         7
               O/D          TCC      GOV.
               SOL.         SOL.     SOL.
                                                                                                                                  DISCONNECT
                                                                                                                                 TRANSMISSION
                                                                                                                                  CONNECTOR
TRANSMISSION ASSEMBLY
        1                                                   10
       11                                                   20
       21                                                   30                  O/D & TCC Solenoid = 25-40 ohms / 0.48 - 0.30 amps
       31                                                   40                  Governor Solenoid = 3-5 ohms / 4 - 2.4 amps
       41                                                   50
Wire Side
               2005 & Up
               (TTVA C1)
                                                                                                                                                 85
                            C1
                                                                                                                                                 86
                                                                                                                         30 87
                                                        CLOSE TO
                                                          PCM
                            14
           VAR SOL CTRL
                            25
           TCC SOL CTRL
           O/D SOL CTRL
                            15
                            31                                                       SOLENOIDS
      TRANS RELAY CTR
                            C2
                                                                                     O/D        TCC
                                                                                                               JUMP 12 VOLTS
                                                                                                                   WITH A
                                                                                                                 FUSED LINK
                                                                                                                TO ONE PIN ON
                                                                                                               A KNOWN GOOD
                                                                                                                  SOLENOID
                                                                                                              JUMP THE OTHER
                                        +                                                                      PIN TO THE CUT
                                                    Fusible                                                  WIRE ON THE ECM C2
                                                     Link
                                                                                                                 CONNECTOR
                                  +
                           BATTERY
                                                                        1                5            6          7
TRANSMISSION ASSEMBLY
                                                                                                                         Face View
       1                                                      10
      11                                                      20
      21                                                      30            O/D & TCC Solenoid = 25-40
                                                                                                                                 6       5
      31                                                      40            ohms / 0.48 - 0.30 amps                                          4
                                                                                                                            7
      41                                                      50            Governor Solenoid = 3-5 ohms                         8
                                                                            / 4 - 2.4 amps                                  1                3
                                                                                                                                     2
A960
L/R, No.2, No.3, and No.4 Sprag Assembly
The low/reverse sprag freewheels counter clockwise and locks clockwise while holding the inner race.
If the sprag is installed incorrect a no forward gear in drive and/or a bind on the 1-2 shift.
To check secondary pulley pressure (line pressure) we are going to need to remove the pressure plug
on the passenger’s side of the transmission shown in figure 1. The fitting threads on the secondary
pressure plug are 14mm x 1.5mm. The pressure is high and we need a 1000 PSI gauge set. I would
recommend the use of a transducer or the Subaru testing equipment.
18801AA000 gauge
18681AA000 fitting
498897700 adaptor set
                                                                                          Figure 1
Copyright © 2014 ATRA All Rights Reserved                                              JW • Page 1 of 3
Lineartronic CVT Gen 1                                                                           #1604
Secondary Pressure and Transfer Clutch Pressure Testing
With the transducer or gauge hooked up check and record pressure readings at idle in park, reverse,
neutral and drive. Then test reverse at stall and drive at stall. In figure 2 is the chart for line pressure
specification for reference. If line pressure is low some of the area’s to look at would be a plugged
filter, bad pump and leaks in the secondary pulley circuit.
Figure 3
The cause of these complaints is a loose fit between the manual lever selector shaft into the MLPS
switch. This happens when the case cover is being installed. The technician sees that the roll pin on
the selector shaft is not lined up with the key way in the case cover. A pair of pliers is used to rotate
the shaft into position. Twisting the shaft with pliers or vise grips will collapse the shaft causing a loose
fit. Simply spread the shaft open to obtain a good fit between the shaft and MLPS switch.
TH400
Diagnosing Late Shifts or No Kick Down
An oldie but a goodie that has plagued many technicians. When a 400 has late shifts, it either has no
vacuum to the modulator or the detent solenoid is active (solenoid is open or leaks). If there’s no kick
down it’s usally an innactive detent solenoid (solenoid stuck closed or no current). A quick way to find
out what’s at fault is with a pressure gauge.
Late Shifts
Measure the line pressure in neutral and drive. The pressure readings should be the same in both
ranges 55-80lbs. If the line pressure jumps to 95-105 in drive and drops back to 55-80lbs when the
lever is placed back in neutral, the detent solenoid circuit is active and is the cause of the late shifts. If
the line pressure is high in neutral and in drive, it’s a vacuum flow or modulator related problem.
If there’s a line pressure increase in drive with remote stater switch, repeat the test using the vehicles
electrical system to energize the solenoid. When using the vehicle electrical system, if there still is no
pressure increase then there is a blown fuse, bad switch or a resistance problem. The late GM trucks
from 1987 on utilize a TPS triggered relay that commonly fails.
       If you have one that will not kick down, has line pressure
       increase with solenoid enegrized. Remove the gear and
       valve from the governor. Blow air through the gear end of
       valve, air must exit at balance port.
The 400 detent solenoid is tied into the modulator circuit. A leak in the solenoid circuit will cause a
pressure boost created by the modulator circuit in drive only and late shifts.
A4CF2
Solenoid and Clutch Apply Chart
                                              Solenoid Apply Chart
                                   PCSV-A        PCSV-B        PCSV-C   PCSV-D     On/Off
                     Range
                                 (OD & L/R)     (2nd & R)       (UD)     TCC      Solenoid
                 Park,Neutral       OFF            ON             ON      OFF       ON
                 Reverse            OFF           OFF             ON      OFF       ON
                 D, 1st           *OFF-ON          ON             OFF     OFF    *ON-OFF
                 D, 2nd              ON           OFF             OFF     ON        OFF
                 D, 3rd             OFF            ON             OFF     ON        OFF
                 D, 4th             OFF           OFF             ON      ON        OFF
                 S - 1st            OFF            ON             OFF     OFF       ON
PCSV-A: When the oil pressure is required for OD clutch or Low & reverse brake, this solenoid valve
must be off.
PCSV-B: When the oil pressure is required for 2nd brake or Reverse clutch, this solenoid valve must be
off. If the manual valve ‘R’ position is selected, the pressure will be applied to the reverse clutch. That
is the reason why the reverse clutch is not engaged in 2nd and 4th gear (PCSV-B off condition)
SCSV (On/Off): When this solenoid valve is off, LR brake pressure is released and the OD clutch pres-
sure is applied. That is the reason why the 3rd gear failsafe (mechanically failed 3rd gear condition) is
possible when the all solenoid valves are off including this solenoid valve.
VFS Solenoid Valve: Changes the line pressure according to throttle open angle (engine load) and shift
ranges.
ZF5HP24
Slips In Reverse
Do you have a Land Rover, Jag or BMW that slips in reverse? Have you already tried another valve
body, solenoids and/or a new C clutch drum and it still slips? Have a look at the C clutch drum shaft
bushings.
Inner Bushing
Outer Bushing
If the bushings are worn reverse oil will be dumped into the lube circuit and pan. Replacment bushings
are availible. The o-rings and teflon sealing rings are equally important as well.
Clutch O-Rings
                              Feed In to C Clutch
           Feed Out to C Clutch