Service Information
Produced: 17.10.2018        Page 1/1
Subject:              USB memory firmware update mul�-device support
Model:                See support list below
Error codes:          -/-
                      Field measures:     Next visit       At Maintenance       By Case
Classification:                           SC/Error         Paper Feeding/Conveying        Firmware / Software
                      Phenomenon:
                                          Image            Machine operation              Information
Related to:
Description: For the conven�onal model firmware update, a USB memory can store only one model firmware.
To improve serviceability, for the new models there is a support for mul� devices on one USB memory.
                                                     Example old / new
                            Supported model - USB memory firmware update mul�-device support
                  Model name
                  ECOSYS M4132idn/ M4125idn
                  ECOSYS M8130cidn/ M8124cidn
                  TASKalfa 307ci
                  TASKalfa 4012i/ 3212i
                  ECOSYS M6230cidn/ M6630cidn/ M6235cidn/ M6635cidn/ TASKalfa 351ci
                  ECOSYS M3660id/ M3655idn/ M3145dn/ M3645dn/ M3145idn/ M3645idn
                  ECOSYS P6230cdn/ P6235cdn/ P7240cdn
                                                KYOCERA Document Solutions
                                                   Service Support/UKU
TSR_055
Service Information
                                                                       Produced: 17.10.2018     Page 2/1
Mul�-model firmware update is to enable the USB memory to store mul�ple model firmware image files for the
firmware update func�on.
The main unit selects the firmware applicable to update from the dedicated directory in the USB memory and installs
the firmware.
When storing the firmware for mul�ple models, it is necessary to create the directories by model in the top-level
directory of the USB memory and store the firmware applicable for each model, in each directory, in order to iden�fy
the model.
Use the following directory configura�on for the different models.
Important:     Don’t change below men�oned folder names in any way.
               The device will not recognize the firmware.
                                          Firmware storage directory by model.
    ECOSYS M4132idn               ECOSYS M8130cidn                   TASKalfa 4012i               TASKalfa 307ci
       FWUP_02P1                     FWUP_02P3                       FWUP_02V6                     FWUP_02SZ
    ECOSYS M4125idn               ECOSYS M8124cidn                  TASKalfa 3212i
       FWUP_02P2                     FWUP_02P4                       FWUP_02V6
    ECOSYS P6230cdn               ECOSYS M6230cidn                 ECOSYS M3660idn               ECOSYS M3145dn
      FWUP_02TV                      FWUP_02V0                       FWUP_02TA                     FWUP_02TF
     ECOSYS P6235cdn              ECOSYS M6630cidn                 ECOSYS M3655idn               ECOSYS M3645dn
      FWUP_02TW                      FWUP_02V1                       FWUP_02TA                    FWUP_02TG
    ECOSYS P7240cdn               ECOSYS M6235cidn                 ECOSYS M3645idn
       FWUP_02TX                     FWUP_02V0                       FWUP_02TA
                                  ECOSYS M6635cidn                 ECOSYS M3145idn
                                     FWUP_02V1                       FWUP_02V2
                                     TASKalfa 351ci
                                     FWUP_02V1
                                               KYOCERA Document Solutions
                                                  Service Support/UKU