Soft Starters & Drives: Industrial Control Product Catalog 2021 Section
Soft Starters & Drives: Industrial Control Product Catalog 2021 Section
contents
Introduction
7 Section
7/2 – 7/3
SIRIUS 3RW soft starters
General data 7/4 – 7/11
High Performance soft starters
3RW55 soft starters
- General Data 7/12 – 7/25
- Inline circuit 7/26 – 7/29
- Inside-delta circuit 7/30 – 7/33
3RW55/55F
- Accessories 7/34 – 7/35
3RW55 Failsafe soft starters
- General Data 7/36 – 7/48
- Inline circuit 7/49
- Inside-delta circuit 7/50
- Accessories 7/51 – 7/52
General Performance soft starters
3RW52 soft starters
- General Data 7/53 – 7/64
- Inline circuit 7/65 – 7/66
- Inside-delta circuit 7/67 – 7/68
- Accessories 7/69 – 7/70
3RW52 Basic Performance soft starters
3RW50 soft starters
- General Data 7/71 – 7/79
- Inline circuit 7/80
- Accessories 7/81 – 7/82
3RW40 soft starters
- General Data 7/83 – 7/89
- Inline circuit 7/90 – 7/91
7
- Accessories 7/92 – 7/93
3RW30 soft starters
SOFT STARTERS
- General Data 7/94 – 7/101
- Inline circuit 7/102
- Accessories 7/103 – 7/104
3RW50
Soft Starter Software 7/105
Spare parts
For 3RW55/3RW55 Failsafe 7/105 – 7/107
For 3RW52 7/108 – 7/109
For 3RW50 7/110
Class 73/74 Enclosed Softstarter applications
Overview 7/111
Application 7/111
Selection and ordering data 7/112 - 7/123
Factory Modifications 7/124
Dimensional drawings 7/125
Schematics 7/126
Introduction
Introduction
Overview
More information
Homepage,
Homepage, seesee www.usa.siemens.com/soft-starter
www.siemens.com/soft-starter Industry
Industry Online Support (SIOS)
(SIOS) topic
topic page,
page,see
see
Industry Mall,
Industry Mall, see
see www.siemens.com/product?3RW
www.siemens.com/product?3RW https://support.industry.siemens.com/cs/ww/en/view/109747404
https://support.industry.siemens.com/cs/ww/en/view/109747404
TIA Selection
TIA Selection Tool
Tool Cloud
Cloud (TST
(TST Cloud),
Cloud),see
see Simulation Tool
Simulation Tool for
for Soft
Soft Starters
Starters(STS),
(STS), see
see page
page 6/8
6/8 or
or
https://www.siemens.com/tstcloud/?node=Sirius3rwFolder
https://www.siemens.com/tstcloud/?node=Sirius3rwFolder https://support.industry.siemens.com/cs/ww/en/view/101494917
https://support.industry.siemens.com/cs/ww/en/view/101494917
Introduction
Introduction
6
• Hybrid switching devices for minimum power loss and two-phase motor control
• Soft Torque for reduced mechanical loading and optimum pump stop
• Parameterization using potentiometers
• ATEX/IECEx certification
3RW40 soft starters • Soft starting and stopping 7/83
• Current limiting
• Motor overload protection (optionally with thermistor motor protection)
• Up to 75HP @ 480V 600V ratings also available)
• Hybrid switching devices for minimum power loss and two-phase motor control
• ATEX certification
3RW30 soft starters • Soft starting with voltage ramp 7/94
• Up to 75HP @ 480V
7
Enclosures in • Complete starter includes 3RW40 or 3RW44 and CPT
NEMA 1, 3, 4, & 12 types 7/111
• Performance Range of up to 600 Hp (at 460 V)
UL/CSA listed
SOFT STARTERS
• Combination options include circuit breaker or fusible disconnect
• Application areas:
- Compressors - Lumber processing
- Pumps - Pulp & paper processing
- Stamping presses - Conveyors
- Cooling towers - Textiles
- Molding and extruding - HVAC
- Chippers and debarkers
Siemens IC 10 · 2020
Soft Starters
Switching Devices – Soft Starters and Solid-State Switching Devices
SIRIUS 3RW Soft Starters SIRIUS 3RW Soft Starters
General data General data
Overview
More information
Homepage,
Homepage, seesee www.usa.siemens.com/soft-starter
www.siemens.com/soft-starter Industry
Industry Online
Online Support (SIOS) topic page,
(SIOS) topic page,see
see
Industry Mall,
Industry Mall, see
see www.siemens.com/product?3RW
www.siemens.com/product?3RW https://support.industry.siemens.com/cs/ww/en/view/109747404
https://support.industry.siemens.com/cs/ww/en/view/109747404
TIA Selection
TIA Selection Tool
Tool Cloud
Cloud (TST
(TST Cloud),
Cloud),see
see Simulation Tool
Simulation Tool for
for Soft
SoftStarters
Starters(STS),
(STS), see
seepage
page 6/8
7/7 or
or
https://www.siemens.com/tstcloud/?node=Sirius3rwFolder
https://www.siemens.com/tstcloud/?node=Sirius3rwFolder https://support.industry.siemens.com/cs/ww/en/view/101494917
https://support.industry.siemens.com/cs/ww/en/view/101494917
3-phase controlled
3RW55 Failsafe
TIA integration
(√3)
7.5 to 400HP to 750HP
General 3RW52
performance 7.5 to 400HP
6
(√3)
to 750HP
2-phase controlled
Basic 3RW50
100 to 400HP
performance
3RW40
7.5 to 75HP
3RW30
1.5 to 75HP
Tupical
Pumping Ventilating Compressing Conveying Processing
IC01_00698
applications
7
SOFT STARTERS
Escalators ● ● ● ●
Piston compressors ● ● ● ●
Screw compressors ● ● ● ●
Small fans1) ● ● ● ●
Centrifugal blowers ● ● ● ●
Bow thrusters ● ● ● ●
7
Circular saws/bandsaws ●
Centrifuges ●
SOFT STARTERS
Mills ●
Crushers ●
● Recommended soft starter 1) The mass inertia of the fan is <10 times the mass inertia of the motor.
2)
❍ Possible soft starter The mass inertia of the fan is 10 times the mass inertia of the motor.
6
Ramp-up and ramp-down time s 0 ... 360 0 ... 360 0 ... 20 0 ... 20 0 ... 20 0 ... 203)
Pump stop (torque control)4) -- -- -- --
• Starting torque % 10 ... 100 10 ... 100 -- -- -- --
• Torque limit % 20 ... 200 20 ... 200 -- -- -- --
Soft Torque (torque limit) -- -- -- --
Integral bypass contact system
Intrinsic device protection --
5) 5) 5) 5)
Motor overload protection --
6) 6) 6)
Thermistor motor protection evaluation --
6) 6)
Analog output -- --
Remote RESET --
Adjustable current limiting --
Inside-delta circuit1) -- -- --
Breakaway pulse -- -- -- --
Automatic parameterization
7
-- -- -- --
Pump cleaning -- -- -- --
Condition monitoring
SOFT STARTERS
-- -- -- --
User account administration8) -- -- -- --
Creep speed in both directions of rotation -- -- -- -- --
Reversing duty -- -- -- --
Reversing DC braking4)7) -- -- -- -- --
DC braking4)7) -- -- -- -- --
Dynamic DC braking4)7) -- -- -- -- --
Motor heating -- -- -- -- --
Communication function9) -- --
9) 9)
HMI module installable in the cabinet door -- --
9) 9)
Operating measured value display -- --
9) 9)
Logbooks -- --
9) 9)
Statistical data and slave pointer function -- --
Trace function8) -- -- -- --
Programmable control inputs and outputs -- -- -- --
Number of parameter sets 3 3 1 1 1 1
Parameterizable via software8) -- -- -- --
Number of controlled phases 3 3 3 2 2 2
Heavy starting CLASS 304) -- -- -- --
5) When using the motor
motor overload
overload protection
protection according
according to
to ATEX/IECEx,
ATEX/IECEx,an
an
Function available
-- Function not available upstream contactor may
may be
be required,
required, see
see page
page 6/11.
7/10.
6)
1)
Inside-delta circuit only up to operational voltage 600 V. Special device versions only.
2) 7) Not possible in inside-delta circuit.
Note derating above 40 °C.
3) Only soft starting available for 3RW30. 8)
With software Soft Starter ES (TIA Portal).
4) 9)
Calculate soft starter and motor with size allowance where required. Only in conjunction with special accessories.
NSB0_01704
of the required rated operational current of the motor. 100
7
Entering the motor and load data will simulate the application
and prompt suggestions for suitable soft starters.
SOFT STARTERS
Link to the free download of the Simulation Tool for Soft Starters
(STS).
• Simple, quick and user-friendly interface
• Detailed and up-to-date Siemens motor database, including
IE3/IE4 motors.
• Simulation of heavy starting up to CLASS 30
• Update-capable (e.g. motors, load types, functions)
• Fast simulations with minimum input data
• Immediate, graphical curve charts of start operations with limit
values
• Table view of suitable soft starters for the application Everything at a glance: Simulation and results list
6
be ordered separately. The harmonic component load for start-
ing currents must be taken into consideration for the selection of
motor starter protectors (selection of release). Please observe
the maximum switching frequencies specified in the technical
specifications.
Notes:
When three-phase motors are switched on, voltage drops occur
as a rule on starters of all types (direct-on-line starters, wye-delta
starters, soft starters). The infeed transformer must always be
Inline circuit: Rated current Ie corresponds to the rated motor current In, dimensioned such that the voltage dip when starting the motor
three cables to the motor remains within the permissible tolerance. If the infeed
transformer is dimensioned with only a small margin, it is best for
the control voltage to be supplied from a separate circuit
L1 NSB0_00425
L2
(independently of the main voltage) in order to avoid the
L3
potential switching off of the soft starter.
7
N
For dimensioning soft starters,
dimensioning soft starters, we
we recommend
recommend our
our Simulation
Simulation
PE
Tool for Soft
Soft Starters
Starters (STS),
(STS), see page 6/8 or
page 7/7
our Technical Support:
Technical Support:
SOFT STARTERS
https://support.industry.siemens.com/My/ww/en/requests.
https://support.industry.siemens.com/My/ww/en/requests.
U2 L2 Recommended parameters for the initial commissioning of our
U1 SIRIUS 3RW soft starters are listed in every report of our
T1 T2 Simulation Tool for Soft Starters (STS). In addition, our
V1 High Performance soft starters provide support by means of
L1 V2 their commissioning wizards.
W2 W1 T3 L3
The types of coordination are indicated in the overload release. That is the case for motor starter protectors
corresponding tables by the symbols shown on (e.g. SIRIUS 3RV20).
orange backgrounds.
Circuit breakers without an overload release (e.g. SIRIUS 3RV23
Feeder tests and events motor starter protectors) must not be used because they do not
provide overload protection. The feeder tests for these were
To keep the scope of feeder tests with SIRIUS 3RW soft starters therefore not performed. If the motor feeder with SIRIUS 3RW
within economically reasonable limits, tests were conducted with soft starters is configured without a fuse, motor starter protectors
feeder components (motor starter protectors/circuit breakers, must be used that ensure tripping on an overload.
fuses) that cover the greatest number of use cases (different soft
starter versions depending on, for example, line voltage, type of Motor protection
circuit, or necessary overdimensioning). For the combined tests If fuses are used to provide
provide protection
protection against
against overload
overload and
that were conducted, the values for the short-circuit breaking short circuit
circuit of
of the
the cables,
cables, the the motor
motorisisprotected
protectedby bythe
the
capacity Iq in kA were determined and documented. SIRIUS 3RW
3RW soft
softstarter.
starter.IfIfthe
theconstraints
constraints(simple
(simplestarting
starting
If the short-circuit breaking capacity is the same, of course, conditions CLASS
CLASS 10, 10, listed
listed maximum
maximumvalues values for
forstarting
starting
smaller circuit breakers or fuses can also be used for the current, starting
starting time
timeand
andnumber
numberofofstarts
startsper perhour)
hour)ofofpage
page6/8
7/7)
selected soft starter provided the dimensioning of the short- are observed,
observed, thethemotor
motorfeeders
feederscan canbe beconfigured
configuredaccording
accordingtoto
7
circuit components is suitable for the connected three-phase IEC as described in the section about soft soft starters
starters (an
(an optional
optional
motor and the line protection for the cables used. For type of line contactor
contactor isisnot
notrequired).
required).IfIfthese
thesepreconditions
preconditionsare aremet, thethe
met,
coordination "2" (with semiconductor protection), it is also SIRIUS 3RW
3RW soft
softstarters
startersareareable
abletototrip
tripononoverloads
overloadstoto protect
protect
SOFT STARTERS
necessary to compare the characteristics because the the motor
motor in
in any
any case.
case.
protection function would no longer be completely ensured if too In other starting conditions and on heavy starting, the following
small a fuse were selected. If the soft starter does not have a must be considered:
motor protection function, the motor protection must also be
dimensioned appropriately. Trip classes
Setting the motor current Tested fuseless switchgear assemblies comprising SIRIUS 3RW
soft starters and motor starter protectors only comply with
If circuit breakers with an overload release are used (e.g. SIRIUS CLASS 10.
3RV20 motor starter protector), we recommend activating the To configure tested motor feeders, for example, for CLASS 20 or
motor protection function of the SIRIUS 3RW soft starter to CLASS 30, fuses must be used together with SIRIUS 3RW soft
protect the motor and setting the soft starter to the rated opera- starters.
tional current Ie of the motor. We recommend setting the circuit
breaker in such a way that it provides line protection but does not Line contactor
usually trip before the soft starter when a motor overload occurs. In applications with high starting frequencies or heavy starting
Line protection and motor protection as of CLASS 20, we recommend combining fuses with the use of
a line contactor on the line side so that a motor overload is
Line protection and motor protection are not ensured in all disconnected by the fault signaling contact of the soft starter in
operating cases, depending on: any case (that is, even in rare cases in which disconnection by
• How the motor feeder is constructed (e.g. with fuses or motor the SIRIUS 3RW soft starter is no longer possible due to the
starter protectors) operating state of the thyristors).
• Whether the SIRIUS 3RW soft starters are operated within the
specification relevant for the tests (IEC 60947-4-2)
• documented constraints
• Or whether the documented constraints (see
(seepage
page7/7)
6/8)have
have
been observed.
observed
6
ATEX/IECEx chapters of the Equipment Manual
Manual for
for the
theselected
selected
Avoid impermissibly high cable surface temperatures by soft starter.
correctly dimensioning the cross-sections.
The cable cross-section must be adequately dimensioned.
■ Benefits
Can be flexibly deployed in many applications
Strong portfolio: Intelligent operation:
comprehensive, coordinated soft starter portfolio concentrated, application-specific functionality
6
• The right hardware for all requirements, • Can be used in a wide variety of applications:
soft starters for tasks ranging from simple to demanding starting in Basic, Pumping, ventilating, compressing, moving and processing
General and High Performance versions
• Integrated, self-learning automatic parameterization depending on motor
• Extensive portfolio for individual expansion: starting conditions
Optional HMIs for installation in the device or mounting on the control
cabinet door • Application-specific functionality such as pump cleaning and pump stop
7
hybrid switching technology on board data available whenever and wherever needed
SOFT STARTERS
• Energy-efficient switching and mechanical protection of the drive train • Support from tools and data during engineering
thanks to soft starters with hybrid switching technology
• Simulation Tool for Soft Starters for support during product selection
• Low-wear switching extends the service life of the devices
• Very simple, standardized commissioning and configuration via
• Soft starting prevents current peaks, thereby increasing the network Soft Starter ES in TIA Portal
stability
• Integration in the automation system via communication interfaces
• Protection against disturbances in the application.
Mechanical protection for the drive train • Data availability and analysis:
large volumes of data at any time and anywhere, even into MindSphere
Overview
More information
Homepage, see
Homepage, see www.usa.siemens.com/soft-starter
www.siemens.com/soft-starter Industry
Industry Online Support (SIOS)
(SIOS) topic
topicpage,
page,see
see
Industry
Industry Mall,
Mall, see
see www.siemens.com/product?3RW
www.siemens.com/product?3RW https://support.industry.siemens.com/cs/ww/en/view/109747404
https://support.industry.siemens.com/cs/ww/en/view/109747404
TIA
TIA Selection
Selection Tool
Tool Cloud
Cloud (TST
(TST Cloud),
Cloud),see
see Simulation Tool
Simulation Tool for
for Soft
Soft Starters
Starters (STS),
(STS), see
see page
page 6/8
7/7 or
or
https://www.siemens.com/tstcloud/?node=Sirius3rwFolder
https://www.siemens.com/tstcloud/?node=3rw55 https://support.industry.siemens.com/cs/ww/en/view/101494917
https://support.industry.siemens.com/cs/ww/en/view/101494917
SIRIUS Soft
SIRIUS Soft Starter
Starter ES
ES (TIA
(TIA Portal),
Portal), see page 14/2
6
5
6 1
7
7
SOFT STARTERS
IC01_00582a
4
2
2 Communication modules
6 HMI push-in lugs for wall mounting
3 Hinged cover
7 HMI IP65 door mounting kit
4 Fan covers
8 HMI soft starter connection cable
5 Terminal covers
■ Benefits
6
Automatic parameterization Extremely easy commissioning and reliability even under changing load
conditions
Hybrid switching devices and three-phase motor control Minimum power loss and optimum/symmetrical motor control
7
Integration into TIA Portal – communication modules optional Efficient configuration and maximum flexibility in automation engineering
SOFT STARTERS
Removable HMI with color display, local interface, slot for micro SD memory Maximum flexibility with regard to user interface and intuitive menu guidance
card
Pump stop and torque control Reduced mechanical loading and optimum pump stop control
Certified according to ATEX/IECEx directive Suitable for the starting of explosion-proof motors
■ Technical specifications
More information
Technical specifications,
Technical specifications,see
see FAQs,
FAQs, see
see https://support.industry.siemens.com/cs/ww/en/ps/25099/faq
https://support.industry.siemens.com/cs/ww/en/ps/25099/faq
https://support.industry.siemens.com/cs/ww/en/ps/25099/td
https://support.industry.siemens.com/cs/ww/en/ps/25099/td Simulation Tool
Simulation Tool for
for Soft
Soft Starters
Starters (STS),
(STS), see
see page
page 6/8
7/7 or
or
Equipment
Equipment Manual
Manual “SIRIUS
"SIRIUS 3RW55
3RW55 Soft Starter",
Starter”, see
see https://support.industry.siemens.com/cs/ww/en/view/101494917
https://support.industry.siemens.com/cs/ww/en/view/101494917
https://support.industry.siemens.com/cs/ww/en/view/109753752
https://support.industry.siemens.com/cs/ww/en/view/109753752
6
side-by-side mounting
• Above mm 100
• At the side mm 5
• Below mm 75
Maximum installation m 5 000 2 000 5 000 2 000 5 000 2 000
altitude above sea level1)
Degree of protection IP00
Ambient conditions
Ambient temperature
• During operation2) °C -25 ... +60
• During storage and °C -40 ... +80
transport
Environmental category
according to IEC 60721
• During operation 3K6 (no ice formation, no condensation), 3C3 (no salt mist),
3S2 (sand must not get into the devices), 3M6
7
• During storage 1K6 (only occasional condensation), 1C2 (no salt mist),
1S2 (sand must not enter the devices), 1M4
SOFT STARTERS
• During transport 2K2, 2C1, 2S1, 2M2 (max. height of fall 0.3 m)
1)
Derating from 1 000
000 m,
m, see
seecharacteristic
characteristiccurve
curveon
onpage
page6/8.
7/7.
2) Note derating above 40 °C.
7
SOFT STARTERS
6
• 350% IM
- Start-up time 5 s 1/h 13 13 13 13 13
- Start-up time 10 s 1/h 4 4 4 4 4
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 13/11.5/10.5 18/15.9/13.8 25/22.3/19.6 29.6/27.2/23.6 33.5/30.5/27.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5 2.5 2.5
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 13/11.5/10.5 18/15.9/13.8 25/22.3/19.6 26/23.6/21.2 29/26/23
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 7 7 7 7 7
- Start-up time 40 s 1/h 3 3 3 3 3
7
• 350% IM
- Start-up time 20 s 1/h 4 4 4 4 4
- Start-up time 40 s 1/h 1.8 1.8 1.8 1.8 1.8
SOFT STARTERS
• 350% IM
- Start-up time 5 s 1/h 13 13 13 13 13
- Start-up time 10 s 1/h 4 4 4 4 4
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 25/22.3/19.6 47/41.6/36.2 63/55.5/50.5 77/68/62 93/82.5/75.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5 2.5 2.5
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 25/22.3/19.6 43.4/38/34.4 53/48/43 68/62/56 82.5/75.5/65
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 7 7 7 7 7
- Start-up time 40 s 1/h 3 3 3 3 3
7
• 350% IM
- Start-up time 20 s 1/h 4 4 4 4 4
- Start-up time 40 s 1/h 1.8 1.8 1.8 1.8 1.8
SOFT STARTERS
Adjustable rated motor current IM
• Minimum/maximum A 5/25 10/47 13/63 16/77 19/93
• Minimum/maximum in inside-delta circuits A 8.7/43.3 17.3/81.4 22.5/109 27.7/133 32.9/161
Type 10
3RW5534 3RW5535 3RW5536
Rated operational current Ie A 113 143 171
Power electronics
Load rating with rated operational current Ie
IEC + UL/CSA, individual mounting at 40/50/60 °C, A 113/101/89 143/128/118 171/153/141
AC-53a
Permissible rated motor current and starts/h
Normal starting (CLASS 10A)
Rated motor current IM, Tu = 40/50/60 °C A 113/101/89 143/128/118 171/153/141
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 5 s 1/h 43 43 43
- Start-up time 10 s 1/h 18 18 18
• 350% IM
- Start-up time 5 s 1/h 28 28 28
- Start-up time 10 s 1/h 10 10 10
Normal starting (CLASS 10E)
Rated motor current IM, Tu = 40/50/60 °C A 113/101/89 143/128/118 171/153/141
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 5 s 1/h 21 21 21
- Start-up time 10 s 1/h 8 8 8
6
• 350% IM
- Start-up time 5 s 1/h 13 13 13
- Start-up time 10 s 1/h 4 4 4
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 109/97/85 128/113/103 141/129/117
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10
- Start-up time 40 s 1/h 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 89/81/74 108/98/88 117/105/93
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 7 7 7
- Start-up time 40 s 1/h 3 3 3
7
• 350% IM
- Start-up time 20 s 1/h 4 4 4
- Start-up time 40 s 1/h 1.8 1.8 1.8
SOFT STARTERS
• 350% IM
- Start-up time 5 s 1/h 13 13 13 13 10 2
- Start-up time 10 s 1/h 4 4 4 4 2 --
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 162/146/130 200/180/160 231/207/183 258/230/202 272/254/236 284/262/240
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5 2.5 2.5 2.5
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 138/122/106 160/140/120 183/159/135 202/174/160 210/190/170 220/200/180
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 7 7 7 7 7 7
- Start-up time 40 s 1/h 3 3 3 3 3 3
7
• 350% IM
- Start-up time 20 s 1/h 4 4 4 4 4 4
- Start-up time 40 s 1/h 1.8 1.8 1.8 1.8 1.8 1.8
SOFT STARTERS
Adjustable rated motor current IM
• Minimum/maximum A 42/210 50/250 63/315 74/370 94/470 114/570
• Minimum/maximum in inside-delta circuits A 72.7/363 86.6/433 109.1/545 128.2/640 162.8/814 197.5/987
6
• 350% IM
- Start-up time 5 s 1/h 13 13 10 9 1
- Start-up time 10 s 1/h 4 4 2 2 1
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 500/450/400 520/470/420 570/520/470 920/840/760 980/900/810
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5 2.5 2.5
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 380/340/300 400/360/320 420/380/340 740/670/600 790/720/650
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 7 7 7 7 7
- Start-up time 40 s 1/h 3 3 3 3 3
7
• 350% IM
- Start-up time 20 s 1/h 4 4 4 4 4
- Start-up time 40 s 1/h 1.8 1.8 1.8 1.8 1.8
SOFT STARTERS
Q1 Q1
Q11 Q11
NSB0_01902
IC01_00544
M M
3~ 3~
ToC
coordina- 1
tion "1"
3RW5513 3RV2032-4TA10 65 3RV2032-4TA10 18 3RV2032-4DA10 65 3RV2032-4DA10 18
3RW5514 3RV2032-4DA10 65 3RV2032-4DA10 15 3RV2032-4EA10 65 3RV2032-4EA10 15
3RW5515 3RV2032-4EA10 65 3RV2032-4EA10 15 3RV2032-4VA10 65 3RV2032-4VA10 15
3RW5516 3RV2032-4VA10 65 3RV2032-4VA10 10 3RV2032-4JA10 65 3RV2032-4JA10 10
3RW5517 3RV2032-4WA10 65 3RV2032-4WA10 10 3RV2032-4RA10 65 3RV2032-4RA10 10
3RW5521 -- -- -- -- -- -- -- --
3RW5524 3RV2032-4JA10 65 3RV2032-4JA10 10 3RV2032-4RA10 65 3RV2032-4RA10 10
3RW5525 3VA2163-7MN32-0AA0 65 3VA2163-7MN32-0AA0 20 3VA2110-7MN32-0AA0 65 3VA2110-7MN32-0AA0 20
3RW5526 3VA2110-7MN32-0AA0 65 3VA2110-7MN32-0AA0 20 3VA2216-7MN32-0AA0 65 3VA2216-7MN32-0AA0 20
3RW5527 3VA2216-7MN32-0AA0 15 3VA2216-7MN32-0AA0 10 3VA2220-7MN32-0AA0 15 3VA2220-7MN32-0AA0 10
3RW5534 3VA2216-7MN32-0AA0 65 -- -- 3VA2220-7MN32-0AA0 65 -- --
3RW5535 3VA2220-7MN32-0AA0 65 -- -- 3VA2325-7MN32-0AA0 65 -- --
3RW5536 3VA2325-7MN32-0AA0 30 3VA2325-7MN32-0AA0 10 3VA2440-7MN32-0AA0 30 3VA2440-7MN32-0AA0 10
3RW5543 3VA2325-7MN32-0AA0 65 3VA2325-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65
3RW5544 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2450-7MN32-0AA0 65 3VA2450-7MN32-0AA0 65
3RW5545 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65
7
3RW5546 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65
3RW5547 3VA2450-7MN32-0AA0 65 3VA2450-7MN32-0AA0 65 3VA2510-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65
3RW5548 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65
SOFT STARTERS
3RW5552 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2716-7AB05-0AA0 65 3VA2716-7AB05-0AA0 65
3RW5553 3VA2510-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65 3VA2716-7AB05-0AA0 65 3VA2716-7AB05-0AA0 65
3RW5554 3VA2510-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65 3VA2716-7AB05-0AA0 65 3VA2716-7AB05-0AA0 65
3RW5556 3VA2716-7AB05-0AA0 65 3VA2716-7AB05-0AA0 65 -- -- -- --
3RW5558 3VA2716-7AB05-0AA0 65 3VA2716-7AB05-0AA0 65 -- -- -- --
Note:
The service factor or measurement inaccuracies have been
taken into account, for example, for the selection of the specified
motor starter protectors/circuit breakers; the specified short-
circuit breaking capacities Iq in kA are covered by combination
tests. Smaller motor starter protectors/circuit breakers than
those specified can be used at any time as smaller ones trip
more quickly in the event of a short circuit (unchanged short-
circuit breaking capacity) and thus protect the soft starter in any
case. The dimensioning of the short-circuit components must,
however, be suitable for the connected three-phase motor and
the line protection for the cables used.
In 690 V systems, in motor feeder tests with soft starters demon-
strable short-circuit breaking capacities can only be achieved
with the use of fuses (Iq > 5 to 10 kA).
F1 F1 F1
IC01_00545a
NSB0_01904
IC01_00565
M M M
3~ 3~ 3~
Soft starters gG class fuse Line contactor (optional) gG class fuse Line contactor (optional)
for systems for systems for systems for systems for systems for systems for systems for systems
up to 690 V up to 480 V up to 690 V up to 600 V up to 480 V up to 600 V up to 480 V up to 600 V
6
in the supply in the supply in the delta in the delta
cable cable
Q11 F1 Q21 Q21 F1 Q21 Q21 Q21 Q21
Type Type Type Type Type Type Type Type Type
Type of ToC Inline circuit Inside-delta circuit
coordina- 1
tion "1"
3RW5513 3NA3820-6 3RT2025 3RT2025 3NA3820-6 3RT2027 3RT2035 3RT2025 3RT2025
3RW5514 3NA3820-6 3RT2026 3RT2027 3NA3820-6 3RT2027 3RT2037 3RT2026 3RT2027
3RW5515 3NA3822-6 3RT2027 3RT2037 3NA3822-6 3RT2036 3RT2037 3RT2027 3RT2037
3RW5516 3NA3824-6 3RT2035 3RT2037 3NA3824-6 3RT2037 3RT2038 3RT2035 3RT2037
3RW5517 3NA3824-6 3RT2035 3RT2037 3NA3824-6 3RT2038 3RT2046 3RT2035 3RT2037
3RW5521 3NA3824-6 3RT2027 3RT2037 3NA3824-6 3RT2036 3RT2037 3RT2027 3RT2037
3RW5524 3NA3824-6 3RT2036 3RT2037 3NA3824-6 3RT2046 3RT2047 3RT2036 3RT2037
3RW5525 3NA3830-6 3RT2037 3RT2046 3NA3830-6 3RT2047 3RT1054 3RT2037 3RT2046
3RW5526 3NA3132-6 3RT2038 3RT2046 3NA3132-6 3RT1055 3RT1055 3RT2038 3RT2046
3RW5527 3NA3136-6 3RT2046 3RT2047 3NA3136-6 3RT1056 3RT1056 3RT2046 3RT2047
7
Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those speci-
fied can be used at any time as smaller ones trip more quickly in
the event of a short circuit (unchanged short-circuit breaking
capacity) and thus protect the soft starter in any case. The
dimensioning of the short-circuit components must, however, be
suitable for the connected three-phase motor and the line
protection for the cables used.
In inside-delta circuits, motor feeders with soft starters can only
be operated in systems with up to 600 V.
F’1
Q21
Q11
NSB0_01905
M
3~
7
3RW5536 3NE1230-0 3RT1056 3RT1064
3RW5543 3NE1230-21) 3RT1064 3RT1064
SOFT STARTERS
3RW5544 3NE1331-0 3RT1065 3RT1065
3RW5545 3NE1334-2 3RT1075 3RT1075
3RW5546 3NE1334-2 3RT1075 3RT1075
3RW5547 3NE1436-2 3RT1076 3RT1276
3RW5548 3NE1437-2 3TF68 3TF68
3RW5552 3NB3350-1KK26 3TF68 3TF69
3RW5553 3NB3351-1KK26 3TF69 3TF69
3RW5554 3NB3351-1KK26 -- --
3RW5556 3NB3354-1KK26 -- --
3RW5558 3NB3357-1KK26 -- --
1)
For systems up to 500 V.
Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those speci-
fied can be used at any time as smaller ones trip more quickly in
the event of a short circuit (unchanged short-circuit breaking
capacity) and thus protect the soft starter in any case. The
dimensioning of the short-circuit components must, however, be
suitable for the connected three-phase motor and the line
protection for the cables used.
In inside-delta
inside-delta circuits,
circuits, aa gR
gRclass
classfull-range
full-rangefuse
fusecould
couldnotnot
provide the semiconductor
semiconductor protection
protection ofof the
the delta-connected
delta-connected
soft starter with a short-circuit breaking capacitythat
breaking capacity thatisisade-
ade-
quate for practical
practical use.
use. InIn this
this case,
case,wewerecommend
recommendusing using
aR class partial-range
partial-range fuses
fusesforforsemiconductor
semiconductorprotection
protectionfor
for
type of coordination "2" (see
coordination “2” (see page
page 6/25).
7/24).
F1 F1 F1
IC01_00546a
IC01_00566
M M M
3~ 3~ 3~
Soft starters gG class fuse aR class fuse Line contactor gG class fuse aR class fuse Line contactor (optional)
(optional)
6
for systems for systems for sys- for sys- for systems for systems for systems for systems for sys- for sys-
up to 690 V up to 690 V tems tems up to 600 V up to 600 V up to 480 V up to 600 V tems tems
up to up to in the sup- in the sup- up to up to
480 V 690 V ply cable ply cable 480 V 600 V
in the delta in the delta
Q11 F1 F3 Q21 Q21 F1 F3 Q21 Q21 Q21 Q21
Type Type Type Type Type Type Type Type Type Type Type
Type of ToC Inline circuit Inside-delta circuit
coordina- 2
tion "2"
3RW5513 3NA3820-6 3NE8017-1 3RT2025 3RT2025 3NA3820-6 3NE8017-1 3RT2027 3RT2035 3RT2025 3RT2025
3RW5514 3NA3820-6 3NE8020-1 3RT2026 3RT2027 3NA3820-6 3NE8020-1 3RT2027 3RT2037 3RT2026 3RT2027
3RW5515 3NA3822-6 3NE8021-1 3RT2027 3RT2037 3NA3822-6 3NE8021-1 3RT2036 3RT2037 3RT2027 3RT2037
3RW5516 3NA3824-6 3NE8022-1 3RT2035 3RT2037 3NA3824-6 3NE8022-1 3RT2037 3RT2038 3RT2035 3RT2037
3RW5517 3NA3824-6 3NE8024-1 3RT2035 3RT2037 3NA3824-6 3NE8024-1 3RT2038 3RT2046 3RT2035 3RT2037
3RW5521 3NA3824-6 3NE8021-1 3RT2027 3RT2037 3NA3824-6 3NE8021-1 3RT2036 3RT2037 3RT2027 3RT2037
3RW5524 3NA3824-6 3NE8024-1 3RT2036 3RT2037 3NA3824-6 3NE8024-1 3RT2046 3RT2047 3RT2036 3RT2037
3RW5525 3NA3830-6 3NE3227 3RT2037 3RT2046 3NA3830-6 3NE3227 3RT2047 3RT1054 3RT2037 3RT2046
3RW5526 3NA3132-6 3NE3227 3RT2038 3RT2046 3NA3132-6 3NE3227 3RT1055 3RT1055 3RT2038 3RT2046
7
3RW5527 3NA3136-6 3NE3227 3RT2046 3RT2047 3NA3136-6 3NE3227 3RT1056 3RT1056 3RT2046 3RT2047
3RW5534 3NA3244-6 3NE3231 3RT1054 3RT1054 3NA3244-6 3NE3231 3RT1064 3RT1064 3RT1054 3RT1054
SOFT STARTERS
3RW5535 3NA3244-6 3NE3233 3RT1055 3RT1055 3NA3244-6 3NE3233 3RT1065 3RT1065 3RT1055 3RT1055
3RW5536 3NA3365-6 3NE3334-0B 3RT1056 3RT1064 3NA3365-6 3NE3334-0B 3RT1066 3RT1075 3RT1056 3RT1064
3RW5543 2 x 3NA3354-6 3NE3333 3RT1064 3RT1064 2 x 3NA3354-6 3NE3333 3RT1075 3RT1075 3RT1064 3RT1064
3RW5544 2 x 3NA3354-6 3NE3335 3RT1065 3RT1065 2 x 3NA3354-6 3NE3335 3RT1076 3RT1076 3RT1065 3RT1065
3RW5545 2 x 3NA3365-6 -- 3RT1075 3RT1075 2 x 3NA3365-6 -- 3TF68 3TF68 3RT1075 3RT1075
3RW5546 2 x 3NA3365-6 -- 3RT1075 3RT1075 2 x 3NA3365-6 -- 3TF69 3TF69 3RT1075 3RT1075
3RW5547 2 x 3NA3365-6 3NE3340-8 3RT1076 3RT1276 2 x 3NA3365-6 3NE3340-8 3TF69 3TF69 3RT1076 3RT1276
3RW5548 2 x 3NA3365-6 3NC3342-1U 3TF68 3TF68 2 x 3NA3365-6 3NC3342-1U -- -- 3TF68 3TF68
3RW5552 2 x 3NA3365-6 3NC3343-1U 3TF68 3TF69 -- 3NC3343-1U -- -- 3TF68 3TF69
3RW5553 2 x 3NA3365-6 3NC3343-1U 3TF69 3TF69 -- 3NC3343-1U -- -- 3TF69 3TF69
3RW5554 2 x 3NA3365-6 3NC3343-1U -- -- -- 3NC3343-1U -- -- -- --
3RW5556 3 x 3NA3365-6 3 x 3NE3340-8 -- -- -- 3 x 3NE3340-8 -- -- -- --
3RW5558 3 x 3NA3365-6 3 x 3NE3340-8 -- -- -- 3 x 3NE3340-8 -- -- -- --
Note:
The specified short-circuit breaking capacities Iq in kA are For CLASS 10 applications,
applications, asas an
an alternative
alternativeto the gG
to the gGclass
class
covered by combination tests. Smaller fuses than those speci- full-range fuses
fuses for
for cable
cable and
andline
lineprotection
protection3NA3
3NA3(F1),
(F1),
fied can be used at any time as smaller ones trip more quickly in 3RV2/3VA
3RV2/3VA motor
motor starter
starter protectors/circuit
protectors/circuit breakers
breakers can also bebe
the event of a short circuit (unchanged short-circuit breaking used, possibly with reduced
possibly with reduced short-circuit
short-circuitbreaking
breakingcapacity
capacity
capacity) and thus protect the soft starter in any case. The (see page 7/21).
6/22). In these cases, optional line contactors can be
dimensioning of the short-circuit components must, however, be dispensed with.
dispensed with.
suitable for the connected three-phase motor and the line
protection for the cables used. In inside-delta circuits, motor feeders with soft starters can only
be operated in systems with up to 600 V.
7
3RW55 Equipment Manual, Appendix A.3)
Soft starters DC braking contactor DC braking contactor assembly
SOFT STARTERS
for systems up to 400 V for systems up to 480 V for systems up to 690 V
with 2 NC contacts + with 3 NO contacts with 3 NO contacts with 3 NO contacts with 3 NO contacts
2 NO contacts parallel parallel parallel parallel parallel
Q11 Q93 Q91 Q92 Q91 Q92
Type Type Type Type Type Type
3RW5513 3RT2517 3RT2015 3RT2016 3RT2015 3RT2016
3RW5514 3RT2518 3RT2015 3RT2017 3RT2015 3RT2023
3RW5515 3RT2526 3RT2015 3RT2025 3RT2015 3RT2025
3RW5516 3RT2526 3RT2015 3RT2025 3RT2015 3RT2027
3RW5517 3RT2535 3RT2015 3RT2027 3RT2015 3RT2027
3RW5521 3RT2526 3RT2015 3RT2025 3RT2015 3RT2025
3RW5524 3RT2535 3RT2016 3RT2027 3RT2016 3RT2035
3RW5525 -- 3RT2024 3RT2027 3RT2024 3RT2037
3RW5526 -- 3RT2025 3RT2035 3RT2025 3RT2037
3RW5527 -- 3RT2027 3RT2036 3RT2027 3RT2037
3RW5534 -- 3RT2035 3RT2037 3RT2035 3RT2038
3RW5535 -- 3RT2036 3RT2038 3RT2036 3RT2046
3RW5536 -- 3RT2037 3RT2046 3RT2037 3RT2047
3RW5543 -- 3RT2045 3RT2047 3RT2045 3RT1054
3RW5544 -- 3RT2045 3RT1055 3RT2045 3RT1055
3RW5545 -- 3RT2446 3RT1056 3RT2446 3RT1056
3RW5546 -- 3RT1055 3RT1056 3RT1055 3RT1064
3RW5547 -- 3RT1456 3RT1065 3RT1456 3RT1065
3RW5548 -- 3RT1456 3RT1066 3RT1456 3RT1075
3RW5552 -- 3RT1065 3RT1075 3RT1065 3RT1075
3RW5553 -- 3RT1065 3RT1075 3RT1065 3RT1075
3RW5554 -- 3RT1466 3RT1076 3RT1466 3RT1076
3RW5556 -- 3RT1476 3TF68 3RT1476 3TF68
3RW5558 -- 3RT1476 3TF69 3RT1476 3TF69
3RW551. 3RW552.
6
13 3 5.5 -- -- 11.5 2 3 7.5 -- 5 3RW5513-@HA@4 1 1 unit
18 4 7.5 -- -- 15.9 3 5 10 -- 5 3RW5514-@HA@4 1 1 unit
25 5.5 11 -- -- 22.3 5 7.5 15 -- 5 3RW5515-@HA@4 1 1 unit
32 7.5 15 -- -- 28.4 7.5 10 20 -- 5 3RW5516-@HA@4 1 1 unit
38 11 18.5 -- -- 33.5 10 10 20 -- 5 3RW5517-@HA@4 1 1 unit
47 11 22 -- -- 41.6 10 10 30 -- 5 3RW5524-@HA@4 1 1 unit
63 18.5 30 -- -- 55.5 15 20 40 -- 5 3RW5525-@HA@4 1 1 unit
77 22 37 -- -- 68 20 25 50 -- 5 3RW5526-@HA@4 1 1 unit
93 22 45 -- -- 82.5 25 30 60 -- 5 3RW5527-@HA@4 1 1 unit
1) 3RW55 soft starter with screw terminals for operational voltage up to 480 V:
Standard delivery time SD = 1 day (d).
SOFT STARTERS
Note:
For the constraints
constraints for
forthe
themotor
motoroutputs
outputsspecified
specifiedhere,
here, see
page 6/8. 7/7.
see page
7
Control supply voltage
SOFT STARTERS
24 V AC/DC 0
110 ... 250 V AC 1
1)
3RW55 soft starter with screw terminals for operational voltage up to 480 V:
Standard delivery time SD = 1 day (d).
Note:
For the constraints
constraints for
forthe
themotor
motoroutputs
outputsspecified
specifiedhere,
here, see
page 6/8. 7/7.
see page
3RW551. 3RW552.
6
25 5.5 11 15 -- 22.3 5 7.5 15 20 5 3RW5515-@HA@5 1 1 unit
32 7.5 15 18.5 -- 28.4 7.5 10 20 25 5 3RW5516-@HA@5 1 1 unit
38 11 18.5 22 -- 33.5 10 10 20 30 5 3RW5517-@HA@5 1 1 unit
Operational voltage 200 ... 690 V
25 5.5 11 15 22 22.3 5 7.5 15 20 5 3RW5521-@HA@6 1 1 unit
47 11 22 30 45 41.6 10 10 30 40 5 3RW5524-@HA@6 1 1 unit
63 18.5 30 37 55 55.5 15 20 40 50 5 3RW5525-@HA@6 1 1 unit
77 22 37 45 75 68 20 25 50 60 5 3RW5526-@HA@6 1 1 unit
93 22 45 55 90 82.5 25 30 60 75 5 3RW5527-@HA@6 1 1 unit
1)
3RW55 soft starter with screw terminals for operational voltage up to 690 V:
Standard delivery time SD = 2 days (d).
SOFT STARTERS
Note:
For the constraints
constraints for
forthe
themotor
motoroutputs
outputsspecified
specifiedhere,
here, see
page 6/8. 7/7.
see page
7
Control supply voltage
SOFT STARTERS
24 V AC/DC 0
110 ... 250 V AC 1
1)
3RW55 soft starter with screw terminals for operational voltage up to 690 V:
- Sizes 3 and 4: Standard delivery time SD = 2 days (d).
- Size 5: Standard delivery time SD = 5 days (d).
Note:
For the constraints
constraintsfor
forthe
themotor
motoroutputs
outputsspecified
specified here, see
here,
page 6/8. 7/7.
see page
3RW551. 3RW552.
At 40 °C for inside-delta circuit At 50 °C for inside-delta circuit SD1) Article No. Price PU PS*
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current At At At current At At At At
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp d
Operational voltage 200 ... 480 V
6
22.5 5.5 11 -- 19.9 5 5 10 -- 5 3RW5513-@HA@4 1 1 unit
31.5 7.5 15 -- 28 7.5 7.5 20 -- 5 3RW5514-@HA@4 1 1 unit
43.3 11 18.5 -- 39 10 10 25 -- 5 3RW5515-@HA@4 1 1 unit
55.4 15 22 -- 49 15 15 30 -- 5 3RW5516-@HA@4 1 1 unit
65.8 18.5 30 -- 58 15 20 40 -- 5 3RW5517-@HA@4 1 1 unit
81.4 22 45 -- 72 20 25 50 -- 5 3RW5524-@HA@4 1 1 unit
109 30 55 -- 96 30 30 75 -- 5 3RW5525-@HA@4 1 1 unit
133 37 75 -- 118 30 40 75 -- 5 3RW5526-@HA@4 1 1 unit
161 45 90 -- 143 40 50 100 -- 5 3RW5527-@HA@4 1 1 unit
1)
3RW55 soft starter with screw terminals for operational voltage up to 480 V:
Standard delivery time SD = 1 day (d).
SOFT STARTERS
Note:
For the constraints
constraints for
forthe
themotor
motoroutputs
outputsspecified
specifiedhere,
here, see
page 6/8. 7/7.
see page
At 40 °C for inside-delta circuit At 50 °C for inside-delta circuit SD1) Article No. Price PU PS*
Opera- Operating power for three- Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional phase motors tional SET, M)
current At At At current At At At At
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp d
Operational voltage 200 ... 480 V
196 55 110 -- 175 50 60 125 -- 5 3RW5534-@HA@4 1 1 unit
6
7
Control supply voltage
SOFT STARTERS
24 V AC/DC 0
110 ... 250 V AC 1
1)
3RW55 soft starter with screw terminals for operational voltage up to 480 V:
Standard delivery time SD = 1 day (d).
Note:
For the constraints
constraintsfor
forthe
themotor
motoroutputs
outputsspecified
specified here, see
here,
page 6/8. 7/7.
see page
3RW551. 3RW552.
At 40 °C for inside-delta circuit At 50 °C for inside-delta circuit SD1) Article No. Price PU PS*
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current At At At current At At At At
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp d
Operational voltage 200 ... 600 V
22.5 5.5 11 15 19.9 5 5 10 15 5 3RW5513-@HA@5 1 1 unit
31.5 7.5 15 18.5 28 7.5 7.5 20 25 5 3RW5514-@HA@5 1 1 unit
6
43.3 11 18.5 22 39 10 10 25 30 5 3RW5515-@HA@5 1 1 unit
55.4 15 22 30 49 15 15 30 40 5 3RW5516-@HA@5 1 1 unit
65.8 18.5 30 37 58 15 20 40 50 5 3RW5517-@HA@5 1 1 unit
43.3 11 18.5 22 39 10 10 25 30 5 3RW5521-@HA@6 1 1 unit
81.4 22 45 45 72 20 25 50 60 5 3RW5524-@HA@6 1 1 unit
109 30 55 55 96 30 30 75 75 5 3RW5525-@HA@6 1 1 unit
133 37 75 90 118 30 40 75 100 5 3RW5526-@HA@6 1 1 unit
161 45 90 110 143 40 50 100 125 5 3RW5527-@HA@6 1 1 unit
3RW55 soft starter with screw terminals for operational voltage up to 600 V:
Standard delivery time SD = 2 days (d).
Note:
SOFT STARTERS
At 40 °C for inside-delta circuit At 50 °C for inside-delta circuit SD1) Article No. Price PU PS*
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current At At At current At At At At
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp d
Operational voltage 200 ... 600 V
196 55 110 132 175 50 60 125 150 5 3RW5534-@HA@6 1 1 unit
6
7
Control supply voltage
SOFT STARTERS
24 V AC/DC 0
110 ... 250 V AC 1
1)
3RW55 soft starter with screw terminals for operational voltage up to 600 V:
- Sizes 3 and 4: Standard delivery time SD = 2 days (d).
- Size 5: Standard delivery time SD = 5 days (d).
Note:
For
For the constraints for
the constraints forthe
themotor
motoroutputs
outputsspecified
specifiedhere,
here, see
page 6/8. 7/7.
see page
3RW5983-0TC20
3RW554 (2x) -- -- } 3RW5984-0TC20 1 1 unit
6
3RW5984-0TC20
Enclosure components
Hinged cover 3RW55 Without cutout -- } 3RW5950-0GL20 1 1 unit
3RW5950-0GL20
Communication modules
7
switch
PROFINET -- } 3RW5980-0CS00 1 1 unit
Standard
PROFIBUS -- } 3RW5980-0CP00 1 1 unit
3RW5980-0CS00
EtherNet/IP -- } 3RW5980-0CE00 1 1 unit
3RW5980-0CE00
Modbus RTU -- } 3RW5980-0CR00 1 1 unit
Modbus TCP -- } 3RW5980-0CT00 1 1 unit
3RW5980-0CR00
3RW5980-0HD00
Connecting cables
HMI connec- 3RW55 5 m, round For door } 3RW5980-0HC60 1 1 unit
tion cable 2.5 m, round mounting } 3UF7933-0BA00-0 1 1 unit
1.0 m, round } 3UF7937-0BA00-0 1 1 unit
0.5 m, round } 3UF7932-0BA00-0 1 1 unit
6
3UF793.-0BA00-0
Further accessories
Push-in lugs -- Two lugs are For HMI 2 3ZY1311-0AA00 1 10 units
for wall mount- required per modules and
ing device communica-
tion modules
3ZY1311-0AA00
Blank labels
Unit labeling 20 mm x For SIRIUS 20 3RT2900-1SB20 100 340 units
plates1) 7 mm, devices
titanium gray
IC01_00181
7
3RT2900-1SB20
SOFT STARTERS
3RW55 starter kit
SIRIUS 3RW55 -- Including 5 3RW5951-1ES04 1 1 unit
starter kit 3RW55 soft starter 13 A,
200 ... 480 V, 24 V AC/DC
Soft Starter ES V15.1,
24 V power supply unit,
connecting cable and
RJ45 network cable
3RW5951-1ES04
1)
PC labeling systems for individual inscription of unit labeling plates are
available from: murrplastik Systemtechnik GmbH (see page 16/15).
Overview
More information
Homepage, see
Homepage, see www.usa.siemens.com/soft-starter
www.siemens.com/soft-starter Simulation
Simulation Tool
Tool for
for Soft
Soft Starters
Starters (STS),
(STS), see
see page
page 6/8
7/7 or
or
Industry
Industry Mall,
Mall, see
see www.siemens.com/product?3RW
www.siemens.com/product?3RW https://support.industry.siemens.com/cs/ww/en/view/101494917
https://support.industry.siemens.com/cs/ww/en/view/101494917
Industry
Industry Online
Online Support
Support (SIOS)
(SIOS)topic
topicpage,
page,see
see SIRIUS Soft
SIRIUS Soft Starter
Starter ES
ES (TIA
(TIA Portal),
Portal), see page 14/2
https://support.industry.siemens.com/cs/ww/en/view/109747404
https://support.industry.siemens.com/cs/ww/en/view/109747404
6
5
1
6
7
7
SOFT STARTERS
IC01_00690
4
2
2 Communication modules
6 HMI push-in lugs for wall mounting
3 Hinged cover
7 HMI IP65 door mounting kit
4 Fan covers
8 HMI soft starter connection cable
5 Terminal covers
3RW55 Failsafe
3RW55 High Performance
Failsafe High Performancesoft
softstarters
starterswith
withaccessories,
accessories see
(seepage
page7/51.
6/52)
■ Benefits
6
Automatic parameterization Extremely easy commissioning and reliability even under changing load
conditions
Hybrid switching devices and three-phase motor control Minimum power loss and optimum/symmetrical motor control
7
Integration into TIA Portal – communication modules optional Efficient configuration and maximum flexibility in automation engineering
SOFT STARTERS
Removable HMI with color display, local interface, slot for micro SD memory Maximum flexibility with regard to user interface and intuitive menu guidance
card
Pump stop and torque control Reduced mechanical loading and optimum pump stop control
Certified according to ATEX/IECEx directive Suitable for the starting of explosion-proof motors
Fail-safe disconnection up to SIL 3 - PL e / STO Reduced costs and space requirements thanks to direct wiring of the
EMERGENCY STOP mushroom pushbutton to the soft starter for SIL 1
Siemens IC 10 · 2020
Soft Starters Switching Devices – Soft Starters and Solid-State Switching Devices
SIRIUS 3RW Soft Starters
High Performance Soft Starters High Performance Soft Starters
3RW55 Failsafe soft starters > General data NEW NEU
3RW55 Failsafe soft starters > General data
■ Technical specifications
More information
Technical specifications,
Technical specifications,see
see FAQs,
FAQs, see
see https://support.industry.siemens.com/cs/ww/en/ps/25776/faq
https://support.industry.siemens.com/cs/ww/en/ps/25776/faq
https://support.industry.siemens.com/cs/ww/en/ps/25776/td
https://support.industry.siemens.com/cs/ww/en/ps/25776/td Simulation Tool
Simulation Tool for
for Soft
Soft Starters
Starters (STS),
(STS), see
see page
page 6/8
7/7 or
or
Equipment
Equipment Manual
Manual “SIRIUS
"SIRIUS 3RW55
3RW55 Soft Starter",
Starter”, see
see https://support.industry.siemens.com/cs/ww/en/view/101494917
https://support.industry.siemens.com/cs/ww/en/view/101494917
https://support.industry.siemens.com/cs/ww/en/view/109753752
https://support.industry.siemens.com/cs/ww/en/view/109753752
D
W
6
• Below mm 75
Maximum installation altitude above sea level1) m 2 000
Degree of protection IP00
Ambient conditions
Ambient temperature
• During operation2) °C -25 ... +60
• During storage and transport °C -40 ... +80
Environmental category according to IEC 60721
• During operation 3K6 (no ice formation, no condensation), 3C3 (no salt mist),
3S2 (sand must not get into the devices), 3M6
• During storage 1K6 (only occasional condensation), 1C2 (no salt mist),
1S2 (sand must not enter the devices), 1M4
• During transport 2K2, 2C1, 2S1, 2M2 (max. height of fall 0.3 m)
1)
Derating from 1 000
000 m,
m, see
seecharacteristic
characteristiccurve
curveon
onpage
page6/8.
7/7.
2) Note derating above 40 °C.
7
SOFT STARTERS
Type 3RW55..-.HF.4
Power electronics
Operational voltage, rated value V 200 ... 480
• Relative negative tolerance/relative positive tolerance % -15/10
Operational voltage for inside-delta circuit, rated value V 200 ... 480
• Relative negative tolerance/relative positive tolerance % -15/10
6
7
SOFT STARTERS
Siemens IC 10 · 2020
Soft Starters Switching Devices – Soft Starters and Solid-State Switching Devices
SIRIUS 3RW Soft Starters
High Performance Soft Starters High Performance Soft Starters
3RW55 Failsafe soft starters > General data
NEW NEU
3RW55 Failsafe soft starters > General data
6
• 350% IM
- Start-up time 5 s 1/h 13 13 13 13 13
- Start-up time 10 s 1/h 4 4 4 4 4
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 13/11.5/10.5 18/15.9/13.8 25/22.3/19.6 29.6/27.2/23.6 33.5/30.5/27.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5 2.5 2.5
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 13/11.5/10.5 18/15.9/13.8 25/22.3/19.6 26/23.6/21.2 29/26/23
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 7 7 7 7 7
- Start-up time 40 s 1/h 3 3 3 3 3
7
• 350% IM
- Start-up time 20 s 1/h 4 4 4 4 4
SOFT STARTERS
• 350% IM
- Start-up time 5 s 1/h 13 13 13 13
- Start-up time 10 s 1/h 4 4 4 4
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 47/41.6/36.2 63/55.5/50.5 77/68/62 93/82.5/75.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7
- Start-up time 40 s 1/h 2.5 0 0 0
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 43.4/38/34.4 53/48/43 68/62/56 82.5/75.5/65
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 7 7 7 7
- Start-up time 40 s 1/h 3 3 3 3
7
• 350% IM
- Start-up time 20 s 1/h 4 4 4 4
SOFT STARTERS
- Start-up time 40 s 1/h 1.8 1.8 1.8 1.8
Adjustable rated motor current IM
• Minimum/maximum A 10/47 13/63 16/77 19/93
• Minimum/maximum in inside-delta circuits A 17.3/81.4 22.5/109 27.7/133 32.9/161
Siemens IC 10 · 2020
Soft Starters Switching Devices – Soft Starters and Solid-State Switching Devices
SIRIUS 3RW Soft Starters
High Performance Soft Starters High Performance Soft Starters
3RW55 Failsafe soft starters > General data
NEW NEU
3RW55 Failsafe soft starters > General data
6
• 350% IM
- Start-up time 5 s 1/h 13 4 0
- Start-up time 10 s 1/h 4 0 0
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 109/97/85 128/113/103 141/129/117
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10
- Start-up time 40 s 1/h 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 6 6
- Start-up time 40 s 1/h 0 0 0
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 89/81/74 108/98/88 117/105/93
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 7 7 7
- Start-up time 40 s 1/h 3 3 3
7
• 350% IM
- Start-up time 20 s 1/h 4 4 4
SOFT STARTERS
• 350% IM
- Start-up time 5 s 1/h 0 13 5 12 6 1
- Start-up time 10 s 1/h 0 4 0 3 0.4 --
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 162/146/130 200/180/160 231/207/183 258/230/202 272/254/236 284/262/240
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7 7 7
- Start-up time 40 s 1/h 2 2.5 2.5 2.5 2.5 2.5
Heavy starting (CLASS 30E)
Rated motor current IM, Tu = 40/50/60 °C A 138/122/106 160/140/120 183/159/135 202/174/160 210/190/170 220/200/180
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 7 7 7 7 7 7
- Start-up time 40 s 1/h 3 3 3 3 3 3
7
• 350% IM
- Start-up time 20 s 1/h 4 4 4 4 4 4
SOFT STARTERS
- Start-up time 40 s 1/h 1.8 1.8 1.8 1.8 1.8 1.8
Adjustable rated motor current IM
• Minimum/maximum A 42/210 50/250 63/315 74/370 94/470 114/570
• Minimum/maximum in inside-delta circuits A 72.7/363 86.6/433 109.1/545 128.2/640 162.8/814 197.5/987
Siemens IC 10 · 2020
Soft Starters Switching Devices – Soft Starters and Solid-State Switching Devices
SIRIUS 3RW Soft Starters
High Performance Soft Starters High Performance Soft Starters
3RW55 Failsafe soft starters > General data
NEW NEU
3RW55 Failsafe soft starters > General data
Motor feeders according to IEC with 3RV2/3VA motor starter protectors/circuit breakers (without semiconductor protection)
Type of coordination "1", CLASS 10,
short-circuit breaking capacity Iq in kA, see table
Note:
generalrecommendations
For general recommendationsforforconstructing
constructing motor
motor feeders
feeders
with soft starters,
starters, see
see page
page7/9.
6/10.
Q1 Q1
Q11 Q11
NSB0_01902
IC01_00544
M M
3~ 3~
6
ToC
coordina- 1
tion "1"
3RW5513 3RV2032-4TA10 65 3RV2032-4TA10 18 3RV2032-4DA10 65 3RV2032-4DA10 18
3RW5514 3RV2032-4DA10 65 3RV2032-4DA10 15 3RV2032-4EA10 65 3RV2032-4EA10 15
3RW5515 3RV2032-4EA10 65 3RV2032-4EA10 15 3RV2032-4VA10 65 3RV2032-4VA10 15
3RW5516 3RV2032-4VA10 65 3RV2032-4VA10 10 3RV2032-4JA10 65 3RV2032-4JA10 10
3RW5517 3RV2032-4WA10 65 3RV2032-4WA10 10 3RV2032-4RA10 65 3RV2032-4RA10 10
3RW5524 3RV2032-4JA10 65 3RV2032-4JA10 10 3RV2032-4RA10 65 3RV2032-4RA10 10
3RW5525 3VA2163-7MN32-0AA0 65 3VA2163-7MN32-0AA0 20 3VA2110-7MN32-0AA0 65 3VA2110-7MN32-0AA0 20
3RW5526 3VA2110-7MN32-0AA0 65 3VA2110-7MN32-0AA0 20 3VA2216-7MN32-0AA0 65 3VA2216-7MN32-0AA0 20
3RW5527 3VA2216-7MN32-0AA0 15 3VA2216-7MN32-0AA0 10 3VA2220-7MN32-0AA0 15 3VA2220-7MN32-0AA0 10
3RW5534 3VA2216-7MN32-0AA0 65 -- -- 3VA2220-7MN32-0AA0 65 -- --
3RW5535 3VA2220-7MN32-0AA0 65 -- -- 3VA2325-7MN32-0AA0 65 -- --
3RW5536 3VA2325-7MN32-0AA0 30 3VA2325-7MN32-0AA0 10 3VA2440-7MN32-0AA0 30 3VA2440-7MN32-0AA0 10
3RW5543 3VA2325-7MN32-0AA0 65 3VA2325-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65
3RW5544 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2450-7MN32-0AA0 65 3VA2450-7MN32-0AA0 65
3RW5545 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65
3RW5546 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65
7
Note:
The service factor or measurement inaccuracies have been
taken into account, for example, for the selection of the specified
motor starter protectors/circuit breakers; the specified short-
circuit breaking capacities Iq in kA are covered by combination
tests. Smaller motor starter protectors/circuit breakers than
those specified can be used at any time as smaller ones trip
more quickly in the event of a short circuit (unchanged short-
circuit breaking capacity) and thus protect the soft starter in any
case. The dimensioning of the short-circuit components must,
however, be suitable for the connected three-phase motor and
the line protection for the cables used.
F1 F1 F1
IC01_00545a
NSB0_01904
IC01_00565
M M M
3~ 3~ 3~
Soft starters gG class fuse Line contactor gG class fuse Line contactor (optional)
(optional)
for systems for systems for systems for systems for systems
6
7
3RW5535 3NA3244-6 3RT1055 3NA3244-6 3RT1065 3RT1055
3RW5536 3NA3365-6 3RT1056 3NA3365-6 3RT1066 3RT1056
3RW5543 2 x 3NA3354-6 3RT1064 2 x 3NA3354-6 3RT1075 3RT1064
SOFT STARTERS
3RW5544 2 x 3NA3354-6 3RT1065 2 x 3NA3354-6 3RT1076 3RT1065
3RW5545 2 x 3NA3365-6 3RT1075 2 x 3NA3365-6 3TF68 3RT1075
3RW5546 2 x 3NA3365-6 3RT1075 2 x 3NA3365-6 3TF69 3RT1075
3RW5547 2 x 3NA3365-6 3RT1076 2 x 3NA3365-6 3TF69 3RT1076
3RW5548 2 x 3NA3365-6 3TF68 2 x 3NA3365-6 -- 3TF68
Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those speci-
fied can be used at any time as smaller ones trip more quickly in
the event of a short circuit (unchanged short-circuit breaking
capacity) and thus protect the soft starter in any case. The
dimensioning of the short-circuit components must, however, be
suitable for the connected three-phase motor and the line
protection for the cables used.
F’1
Q21
Q11
NSB0_01905
M
3~
6
up to 480 V up to 480 V
Q11 F’1 Q21
Type Type Type
Type of ToC Inline circuit
coordina- 2
tion "2"
3RW5513 3NE1815-0 3RT2025
3RW5514 3NE1802-0 3RT2026
3RW5515 3NE1817-0 3RT2027
3RW5516 3NE1818-0 3RT2035
3RW5517 3NE1820-0 3RT2035
3RW5524 3NE1021-2 3RT2036
3RW5525 3NE1022-0 3RT2037
3RW5526 3NE1224-0 3RT2038
3RW5527 3NE1224-0 3RT2046
3RW5534 3NE1225-0 3RT1054
3RW5535 3NE1227-0 3RT1055
3RW5536 3NE1230-0 3RT1056
7
Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those speci-
fied can be used at any time as smaller ones trip more quickly in
the event of a short circuit (unchanged short-circuit breaking
capacity) and thus protect the soft starter in any case. The
dimensioning of the short-circuit components must, however, be
suitable for the connected three-phase motor and the line
protection for the cables used.
inside-delta circuits,
In inside-delta circuits,aagR
gRclass
classfull-range
full-rangefuse
fusecould
couldnotnot
provide the
provide the semiconductor
semiconductor protection
protectionof ofthe
thedelta-connected
delta-connected
soft starter with a short-circuit breaking
breaking capacity
capacitythat
thatisis
adequate for
adequate for practical
practicaluse.
use.InInthis
thiscase,
case,we werecommend
recommendusing using
class partial-range
aR class partial-rangefuses
fusesfor
forsemiconductor
semiconductorprotection
protectionforfor
coordination “2”
type of coordination "2" (see page 7/47).
6/48).
F1 F1 F1
IC01_00546a
IC01_00566
M M M
3~ 3~ 3~
Soft starters gG class fuse aR class fuse Line contactor gG class fuse aR class fuse Line contactor (optional)
(optional)
6
for systems for systems for systems for systems for systems for systems for systems
up to 480 V up to 480 V up to 480 V up to 480 V up to 480 V up to 480 V up to 480 V
in the supply in the delta
cable
Q11 F1 F3 Q21 F1 F3 Q21 Q21
Type Type Type Type Type Type Type Type
Type of ToC Inline circuit Inside-delta circuit
coordina- 2
tion "2"
3RW5513 3NA3820-6 3NE8017-1 3RT2025 3NA3820-6 3NE8017-1 3RT2027 3RT2025
3RW5514 3NA3820-6 3NE8020-1 3RT2026 3NA3820-6 3NE8020-1 3RT2027 3RT2026
3RW5515 3NA3822-6 3NE8021-1 3RT2027 3NA3822-6 3NE8021-1 3RT2036 3RT2027
3RW5516 3NA3824-6 3NE8022-1 3RT2035 3NA3824-6 3NE8022-1 3RT2037 3RT2035
3RW5517 3NA3824-6 3NE8024-1 3RT2035 3NA3824-6 3NE8024-1 3RT2038 3RT2035
3RW5524 3NA3824-6 3NE8024-1 3RT2036 3NA3824-6 3NE8024-1 3RT2046 3RT2036
3RW5525 3NA3830-6 3NE3227 3RT2037 3NA3830-6 3NE3227 3RT2047 3RT2037
3RW5526 3NA3132-6 3NE3227 3RT2038 3NA3132-6 3NE3227 3RT1055 3RT2038
3RW5527 3NA3136-6 3NE3227 3RT2046 3NA3136-6 3NE3227 3RT1056 3RT2046
7
3RW5534 3NA3244-6 3NE3231 3RT1054 3NA3244-6 3NE3231 3RT1064 3RT1054
3RW5535 3NA3244-6 3NE3233 3RT1055 3NA3244-6 3NE3233 3RT1065 3RT1055
3RW5536 3NA3365-6 3NE3334-0B 3RT1056 3NA3365-6 3NE3334-0B 3RT1066 3RT1056
SOFT STARTERS
3RW5543 2 x 3NA3354-6 3NE3333 3RT1064 2 x 3NA3354-6 3NE3333 3RT1075 3RT1064
3RW5544 2 x 3NA3354-6 3NE3335 3RT1065 2 x 3NA3354-6 3NE3335 3RT1076 3RT1065
3RW5545 2 x 3NA3365-6 -- 3RT1075 2 x 3NA3365-6 -- 3TF68 3RT1075
3RW5546 2 x 3NA3365-6 -- 3RT1075 2 x 3NA3365-6 -- 3TF69 3RT1075
3RW5547 2 x 3NA3365-6 3NE3340-8 3RT1076 2 x 3NA3365-6 3NE3340-8 3TF69 3RT1076
3RW5548 2 x 3NA3365-6 3NC3342-1U 3TF68 2 x 3NA3365-6 3NC3342-1U -- 3TF68
Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those speci-
fied can be used at any time as smaller ones trip more quickly in
the event of a short circuit (unchanged short-circuit breaking
capacity) and thus protect the soft starter in any case. The
dimensioning of the short-circuit components must, however, be
suitable for the connected three-phase motor and the line
protection for the cables used.
For
For CLASS
CLASS 10
10 applications,
applications, asas an
an alternative
alternative to
to the
the gG
gG class
class
full-range fuses for
full-range fuses for cable
cable and
andline
lineprotection
protection3NA3
3NA3(F1),
(F1),
3RV2/3VA
3RV2/3VA motor
motor starter
starter protectors/circuit
protectors/circuit breakers
breakers can
can also be
also be
used,
used, possibly with reduced
possibly with reduced short-circuit
short-circuitbreaking
breakingcapacity
capacity
(see
(see page 6/45). In
page 7/44). In these
these cases,
cases, optional
optional line contactors can
line contactors can be
be
dispensed with.
dispensed with.
6
3RW5543 -- 3RT1064
3RW5544 -- 3RT1065
3RW5545 -- 3RT1075
3RW5546 -- 3RT1075
3RW5547 -- 3RT1076
3RW5548 -- 3TF68
7
SOFT STARTERS
7
Standard delivery time SD = 1 day (d).
page 6/8. 7/7.
see page
SOFT STARTERS
At 40 °C At 50 °C SD1) Article No. Price PU PS*
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current At At current At At At
230 V 400 V 200/208 V 220/230 V 460/480 V
A kW kW A hp hp hp d
Operational voltage 200 ... 480 V
113 30 55 101 30 30 75 5 3RW5534-@HF@4 1 1 unit
143 37 75 128 40 40 100 5 3RW5535-@HF@4 1 1 unit
171 45 90 153 50 50 100 5 3RW5536-@HF@4 1 1 unit
210 55 110 186 50 60 150 5 3RW5543-@HF@4 1 1 unit
250 75 132 220 60 75 150 5 3RW5544-@HF@4 1 1 unit
315 90 160 279 75 100 200 5 3RW5545-@HF@4 1 1 unit
370 110 200 328 100 125 250 5 3RW5546-@HF@4 1 1 unit
470 132 250 416 150 150 350 5 3RW5547-@HF@4 1 1 unit
570 160 315 504 150 200 400 5 3RW5548-@HF@4 1 1 unit
6
43.3 11 18.5 39 10 10 25 5 3RW5515-@HF@4 1 1 unit
55.4 15 22 49 15 15 30 5 3RW5516-@HF@4 1 1 unit
65.8 18.5 30 58 15 20 40 5 3RW5517-@HF@4 1 1 unit
81.4 22 45 72 20 25 50 5 3RW5524-@HF@4 1 1 unit
109 30 55 96 30 30 75 5 3RW5525-@HF@4 1 1 unit
133 37 75 118 30 40 75 5 3RW5526-@HF@4 1 1 unit
161 45 90 143 40 50 100 5 3RW5527-@HF@4 1 1 unit
pagepage
see 6/8.7/7.
SOFT STARTERS
At 40 °C for inside-delta circuit At 50 °C for inside-delta circuit SD1) Article No. Price PU PS*
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional three-phase motors tional SET, M)
current At At current At At At
230 V 400 V 200/208 V 220/230 V 460/480 V
A kW kW A hp hp hp d
Operational voltage 200 ... 480 V
196 55 110 175 50 60 125 5 3RW5534-@HF@4 1 1 unit
248 75 132 222 75 75 150 5 3RW5535-@HF@4 1 1 unit
296 90 160 265 75 100 200 5 3RW5536-@HF@4 1 1 unit
364 110 200 322 100 125 250 5 3RW5543-@HF@4 1 1 unit
433 132 250 381 125 150 300 5 3RW5544-@HF@4 1 1 unit
546 160 315 483 150 200 400 5 3RW5545-@HF@4 1 1 unit
641 200 355 568 200 200 450 5 3RW5546-@HF@4 1 1 unit
814 250 400 721 250 250 600 5 3RW5547-@HF@4 1 1 unit
987 315 560 873 300 350 750 5 3RW5548-@HF@4 1 1 unit
1) Note:
3RW55 soft starter with screw terminals for operational voltage up to 480 V:
Standard delivery time SD = 1 day (d). For the
For the constraints
constraintsfor
forthe
themotor
motoroutputs
outputsspecified
specified here, see
here,
pagepage
see 6/8.7/7.
3RW5983-0TC20
3RW5984-0TC20
Enclosure components
Hinged cover 3RW55 Without cutout -- } 3RW5950-0GL20 1 1 unit
3RW5950-0GL20
Communication modules
7
Communica- 3RW55 PROFINET -- } 3RW5950-0CH00 1 1 unit
tion module High Feature
SOFT STARTERS
with integral
switch
PROFINET -- } 3RW5980-0CS00 1 1 unit
Standard
PROFIBUS -- } 3RW5980-0CP00 1 1 unit
3RW5980-0CS00
3RW5980-0CE00
Modbus RTU -- } 3RW5980-0CR00 1 1 unit
Modbus TCP -- } 3RW5980-0CT00 1 1 unit
3RW5980-0CR00
3RW5980-0HD00
Connecting cables
HMI connec- 3RW55 5 m, round For door } 3RW5980-0HC60 1 1 unit
tion cable 2.5 m, round mounting } 3UF7933-0BA00-0 1 1 unit
1.0 m, round } 3UF7937-0BA00-0 1 1 unit
0.5 m, round } 3UF7932-0BA00-0 1 1 unit
6
3UF793.-0BA00-0
Further accessories
Push-in lugs -- Two lugs are For HMI 2 3ZY1311-0AA00 1 10 units
for wall mount- required per modules and
ing device communica-
tion modules
3ZY1311-0AA00
Blank labels
Unit labeling -- 20 mm x For SIRIUS 20 3RT2900-1SB20 100 340 units
plates1) 7 mm, devices
titanium gray
IC01_00181
7
3RT2900-1SB20
SOFT STARTERS
Overview
More information
Homepage, www.siemens.com/soft-starter
Homepage, see www.usa.siemens.com/soft-starter Industry
Industry Online Support (SIOS)
(SIOS) topic
topic page,
page,see
see
Industry Mall,
Mall, see
see www.siemens.com/product?3RW52
www.siemens.com/product?3RW52 https://support.industry.siemens.com/cs/ww/en/view/109747404
https://support.industry.siemens.com/cs/ww/en/view/109747404
TIA Selection
TIA Selection Tool
Tool Cloud
Cloud (TST
(TST Cloud),
Cloud),see
see Simulation Tool
Simulation Tool for
for Soft
Soft Starters
Starters (STS),
(STS), see
see page
page 6/8
7/7 or
or
https://www.siemens.com/tstcloud/?node=3rw52
https://www.siemens.com/tstcloud/?node=3rw52 https://support.industry.siemens.com/cs/ww/en/view/101494917
https://support.industry.siemens.com/cs/ww/en/view/101494917
SIRIUS Soft
SIRIUS Soft Starter
Starter ES
ES(TIA
(TIA Portal)
Portal),for
see page 14/5 see page 14/5
diagnostics,
7
4
7
SOFT STARTERS
2
IC01_00581a
5
3
2 HMI modules
3 Communication modules
7 Push-in lugs for wall mounting
4 Hinged cover
8 IP65 door mounting kit
5 Fan covers
9 HMI soft starter connection cable
6 Terminal covers
3RW52 General
General Performance
Performance soft
soft starters
starters with
with accessories
accessories(see
(seepage 6/70),for
page7/69), forexpansion
expansionwith
withHMI
HMImodule
moduleororcommunication
communicationmodule
module
■ Benefits
6
Product characteristics / function Performance features / benefits
Hybrid switching devices and three-phase motor control Minimum power loss and optimum/symmetrical motor control
TIA-Integration – communication modules and HMI modules optional Efficient configuration and maximum flexibility in automation engineering
Wide range for control supply and main voltage Low variance, high system availability even with weak supply networks
Technical specifications
More information
Technical specifications,see
Technical specifications, see FAQs,
FAQs, see
see https://support.industry.siemens.com/cs/ww/en/ps/25100/faq
https://support.industry.siemens.com/cs/ww/en/ps/25100/faq
https://support.industry.siemens.com/cs/ww/en/ps/25100/td
https://support.industry.siemens.com/cs/ww/en/ps/25100/td Simulation Tool
Simulation Tool for
for Soft
Soft Starters
Starters (STS),
(STS), see
see page
page 6/8
7/7 or
or
Equipment Manual
Manual “SIRIUS
"SIRIUS 3RW52 Soft Starter",
Starter”, see
see https://support.industry.siemens.com/cs/ww/en/view/101494917
https://support.industry.siemens.com/cs/ww/en/view/101494917
https://support.industry.siemens.com/cs/ww/en/view/109753751
https://support.industry.siemens.com/cs/ww/en/view/109753751
can be rotated can be rotated can be rotated for vertical mounting surface can be
+/- 10° and tilted +/- 90°, +/- 10° and tilted tilted +/- 22.5° forward or backward
forward or for vertical forward or
backward mounting surface backward
can be tilted
+/- 22.5° forward
or backward
Distance to be maintained with side-by-side mounting
• Above mm 100
• At the side mm 5
• Below mm 75
Maximum installation altitude above sea level1) m 5 000
Degree of protection IP00
Ambient conditions
Ambient temperature
• During operation2) °C -25 ... +60
7
• During storage and transport °C -40 ... +80
Environmental category according to IEC 60721
SOFT STARTERS
• During operation 3K6 (no ice formation, no condensation), 3C3 (no salt mist),
3S2 (sand must not get into the devices), 3M6
• During storage 1K6 (only occasional condensation), 1C2 (no salt mist),
1S2 (sand must not enter the devices), 1M4
• During transport 2K2, 2C1, 2S1, 2M2 (max. height of fall 0.3 m)
1) Derating
Derating from 1 000 m,
m, see
see characteristic
characteristiccurve
curveon
onpage
page6/8.
7/7.
2)
Note derating above 40 °C.
6
Operating frequency, rated value Hz 50 ... 60
• Relative negative tolerance/relative positive tolerance % -10/10
Minimum load [% of IM]1) % 15
Maximum cable length between soft starter and motor m 800
1) Relative to the smallest adjustable Ie.
7
SOFT STARTERS
• 350% IM
- Start-up time 20 s 1/h 13 13 13 13 13
- Start-up time 40 s 1/h 4 4 4 4 4
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 13/11.5/10.5 18/15.9/13.8 25/22.3/19.6 29.6/27.2/23.6 33.5/30.5/27.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5 2.5 2.5
Adjustable rated motor current IM
• Minimum/maximum A 5.5/13 7.5/18 11.5/25 14/32 15.5/38
• Minimum/maximum in inside-delta circuits A 9.5/22.5 13/31.2 19.9/43.3 24.2/55.4 26.8/65.8
7
SOFT STARTERS
6
• 350% IM
- Start-up time 20 s 1/h 13 13 13 13
- Start-up time 40 s 1/h 4 4 4 4
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 47/41.6/36.2 63/55.5/50.5 65/59/53 93/82.5/75.5
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10
- Start-up time 40 s 1/h 4 3 4 4
• 350% IM
- Start-up time 20 s 1/h 7 4 7 7
- Start-up time 40 s 1/h 2 0 2.5 2.5
Adjustable rated motor current IM
• Minimum/maximum A 20/47 25.5/63 32/77 40.5/93
• Minimum/maximum in inside-delta circuits A 34.6/81.4 44.2/109 55.4/133 70.1/161
7
SOFT STARTERS
Type 10
3RW5234 3RW5235 3RW5236
Rated operational current Ie A 113 143 171
Power electronics
Load rating with rated operational current Ie
IEC + UL/CSA, individual mounting A 113/101/89 143/128/118 171/153/141
at 40/50/60 °C, AC-53a
Permissible rated motor current and starts/h
Normal starting (CLASS 10A)
Rated motor current IM, Tu = 40/50/60 °C A 113/101/89 143/128/118 171/153/141
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 5 s 1/h 43 43 43
- Start-up time 10 s 1/h 18 18 18
• 350% IM
- Start-up time 5 s 1/h 28 27 20
- Start-up time 10 s 1/h 10 8 4
Normal starting (CLASS 10E)
Rated motor current IM, Tu = 40/50/60 °C A 113/101/89 139/127/116 158/146/129
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 21 21 21
- Start-up time 40 s 1/h 8 8 8
6
• 350% IM
- Start-up time 20 s 1/h 13 12 12
- Start-up time 40 s 1/h 4 1 1
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 109/97/85 113/103/93 129/117/105
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10
- Start-up time 40 s 1/h 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5
Adjustable rated motor current IM
• Minimum/maximum A 53/113 68/143 81/171
• Minimum/maximum in inside-delta circuits A 91.8/196 118/248 140/296
7
SOFT STARTERS
6
• 350% IM
- Start-up time 20 s 1/h 12 13 12 13 13 11
- Start-up time 40 s 1/h 1 4 3 4 4 2
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 162/146/130 200/180/160 195/171/147 258/230/202 272/236/218 284/262/240
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5 2.5 2.5 2.5
Adjustable rated motor current IM
• Minimum/maximum A 90/210 100/250 135/315 160/370 200/470 240/570
• Minimum/maximum in inside-delta circuits A 156/364 173/433 234/546 277/641 346/814 416/987
7
SOFT STARTERS
Q1 Q1
Q11 Q11
NSB0_01902
IC01_00544
M M
3~ 3~
ToC
coordina- 1
tion "1"
3RW5213 3RV2032-4TA10 65 3RV2032-4TA10 18 3RV2032-4DA10 65 3RV2032-4DA10 18
3RW5214 3RV2032-4DA10 65 3RV2032-4DA10 15 3RV2032-4EA10 65 3RV2032-4EA10 15
3RW5215 3RV2032-4EA10 65 3RV2032-4EA10 15 3RV2032-4VA10 65 3RV2032-4VA10 15
3RW5216 3RV2032-4VA10 65 3RV2032-4VA10 10 3RV2032-4JA10 65 3RV2032-4JA10 10
3RW5217 3RV2032-4WA10 65 3RV2032-4WA10 10 3RV2032-4RA10 65 3RV2032-4RA10 10
3RW5224 3RV2032-4JA10 65 3RV2032-4JA10 10 3RV2032-4RA10 65 3RV2032-4RA10 10
3RW5225 3VA2163-7MN32-0AA0 65 3VA2163-7MN32-0AA0 20 3VA2110-7MN32-0AA0 65 3VA2110-7MN32-0AA0 20
3RW5226 3VA2110-7MN32-0AA0 65 3VA2110-7MN32-0AA0 20 3VA2216-7MN32-0AA0 65 3VA2216-7MN32-0AA0 20
3RW5227 3VA2216-7MN32-0AA0 15 3VA2216-7MN32-0AA0 10 3VA2220-7MN32-0AA0 15 3VA2220-7MN32-0AA0 10
3RW5234 3VA2216-7MN32-0AA0 65 -- -- 3VA2220-7MN32-0AA0 65 -- --
3RW5235 3VA2220-7MN32-0AA0 65 -- -- 3VA2325-7MN32-0AA0 65 -- --
3RW5236 3VA2325-7MN32-0AA0 30 3VA2325-7MN32-0AA0 10 3VA2440-7MN32-0AA0 30 3VA2440-7MN32-0AA0 10
3RW5243 3VA2325-7MN32-0AA0 65 3VA2325-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65
3RW5244 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2450-7MN32-0AA0 65 3VA2450-7MN32-0AA0 65
3RW5245 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65
3RW5246 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65
7
3RW5247 3VA2450-7MN32-0AA0 65 3VA2450-7MN32-0AA0 65 3VA2510-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65
3RW5248 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65 3VA2510-6HN32-0AA0 65
SOFT STARTERS
Note:
The service factor or measurement inaccuracies have been
taken into account, for example, for the selection of the specified
motor starter protectors/circuit breakers; the specified short-
circuit breaking capacities Iq in kA are covered by combination
tests. Smaller motor starter protectors/circuit breakers than
those specified can be used at any time as smaller ones trip
more quickly in the event of a short circuit (unchanged short-
circuit breaking capacity) and thus protect the soft starter in any
case. The dimensioning of the short-circuit components must,
however, be suitable for the connected three-phase motor and
the line protection for the cables used.
F1 F1 F1
IC01_00545a
NSB0_01904
IC01_00565
M M M
3~ 3~ 3~
Soft starters gG class fuse Line contactor (optional) gG class fuse Line contactor (optional)
for systems for systems for systems for systems for systems for systems for systems for systems
up to 600 V up to 480 V up to 600 V up to 600 V up to 480 V up to 600 V up to 480 V up to 600 V
6
in the supply in the supply in the delta in the delta
cable cable
Q11 F1 Q21 Q21 F1 Q21 Q21 Q21 Q21
Type Type Type Type Type Type Type Type Type
Type of ToC Inline circuit Inside-delta circuit
coordina- 1
tion "1"
3RW5213 3NA3820-6 3RT2025 3RT2025 3NA3820-6 3RT2027 3RT2035 3RT2025 3RT2025
3RW5214 3NA3820-6 3RT2026 3RT2027 3NA3820-6 3RT2027 3RT2037 3RT2026 3RT2027
3RW5215 3NA3822-6 3RT2027 3RT2037 3NA3822-6 3RT2036 3RT2037 3RT2027 3RT2037
3RW5216 3NA3824-6 3RT2035 3RT2037 3NA3824-6 3RT2037 3RT2038 3RT2035 3RT2037
3RW5217 3NA3824-6 3RT2035 3RT2037 3NA3824-6 3RT2038 3RT2046 3RT2035 3RT2037
3RW5224 3NA3824-6 3RT2036 3RT2037 3NA3824-6 3RT2046 3RT2047 3RT2036 3RT2037
3RW5225 3NA3830-6 3RT2037 3RT2046 3NA3830-6 3RT2047 3RT1054 3RT2037 3RT2046
3RW5226 3NA3132-6 3RT2038 3RT2046 3NA3132-6 3RT1055 3RT1055 3RT2038 3RT2046
3RW5227 3NA3136-6 3RT2046 3RT2047 3NA3136-6 3RT1056 3RT1056 3RT2046 3RT2047
3RW5234 3NA3244-6 3RT1054 3RT1054 3NA3244-6 3RT1064 3RT1064 3RT1054 3RT1054
7
Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those speci-
fied can be used at any time as smaller ones trip more quickly in
the event of a short circuit (unchanged short-circuit breaking
capacity) and thus protect the soft starter in any case. The
dimensioning of the short-circuit components must, however, be
suitable for the connected three-phase motor and the line
protection for the cables used.
F’1
Q21
Q11
NSB0_01905
M
3~
7
3RW5243 3NE1230-21) 3RT1064 3RT1064
3RW5244 3NE1331-0 3RT1065 3RT1065
SOFT STARTERS
3RW5245 3NE1334-2 3RT1075 3RT1075
3RW5246 3NE1334-2 3RT1075 3RT1075
3RW5247 3NE1436-2 3RT1076 3RT1276
3RW5248 3NE1437-2 3TF68 3TF68
1)
For systems up to 500 V.
Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those speci-
fied can be used at any time as smaller ones trip more quickly in
the event of a short circuit (unchanged short-circuit breaking
capacity) and thus protect the soft starter in any case. The
dimensioning of the short-circuit components must, however, be
suitable for the connected three-phase motor and the line
protection for the cables used.
In inside-delta
inside-delta circuits,
circuits, aagR
gRclass
classfull-range
full-rangefusefusecould
couldnotnot
provide the semiconductor
provide the semiconductor protection
protection of of the
the delta-connected
delta-connected
soft starter with a short-circuit breaking
breaking capacity
capacitythatthatisis
adequate for practical
adequate for practicaluse.
use.InInthis
thiscase,
case,we werecommend
recommendusing using
aR class partial-range
partial-range fuses
fusesfor
forsemiconductor
semiconductorprotection
protectionforfor
type of coordination "2" (see
coordination “2” (see page
page 6/65).
7/64).
F1 F1 F1
IC01_00546a
IC01_00566
M M M
3~ 3~ 3~
Soft starters gG class fuse aR class fuse Line contactor gG class fuse aR class fuse Line contactor (optional)
(optional)
6
for systems for systems for sys- for sys- for systems for systems for systems for systems for sys- for sys-
up to 600 V up to 500 V tems tems up to 600 V up to 600 V up to 480 V up to 600 V tems tems
up to up to in the supply in the supply up to up to
480 V 600 V cable cable 480 V 600 V
in the delta in the delta
Q11 F1 F3 Q21 Q21 F1 F3 Q21 Q21 Q21 Q21
Type Type Type Type Type Type Type Type Type Type Type
Type of ToC Inline circuit Inside-delta circuit
coordina- 2
tion "2"
3RW5213 3NA3820-6 3NE8017-1 3RT2025 3RT2025 3NA3820-6 3NE8017-1 3RT2027 3RT2035 3RT2025 3RT2025
3RW5214 3NA3820-6 3NE8020-1 3RT2026 3RT2027 3NA3820-6 3NE8020-1 3RT2027 3RT2037 3RT2026 3RT2027
3RW5215 3NA3822-6 3NE8021-1 3RT2027 3RT2037 3NA3822-6 3NE8021-1 3RT2036 3RT2037 3RT2027 3RT2037
3RW5216 3NA3824-6 3NE8022-1 3RT2035 3RT2037 3NA3824-6 3NE8022-1 3RT2037 3RT2038 3RT2035 3RT2037
3RW5217 3NA3824-6 3NE8024-1 3RT2035 3RT2037 3NA3824-6 3NE8024-1 3RT2038 3RT2046 3RT2035 3RT2037
3RW5224 3NA3824-6 3NE8024-1 3RT2036 3RT2037 3NA3824-6 3NE8024-1 3RT2046 3RT2047 3RT2036 3RT2037
3RW5225 3NA3830-6 3NE8024-1 3RT2037 3RT2046 3NA3830-6 3NE8024-1 3RT2047 3RT1054 3RT2037 3RT2046
3RW5226 3NA3132-6 3NE8024-1 3RT2038 3RT2046 3NA3132-6 3NE8024-1 3RT1055 3RT1055 3RT2038 3RT2046
7
3RW5227 3NA3136-6 3NE4124 3RT2046 3RT2047 3NA3136-6 3NE4124 3RT1056 3RT1056 3RT2046 3RT2047
3RW5234 3NA3244-6 3NE3332-0B 3RT1054 3RT1054 3NA3244-6 3NE3332-0B 3RT1064 3RT1064 3RT1054 3RT1054
3RW5235 3NA3244-6 3NE3334-0B 3RT1055 3RT1055 3NA3244-6 3NE3334-0B 3RT1065 3RT1065 3RT1055 3RT1055
SOFT STARTERS
3RW5236 3NA3365-6 3NE3335 3RT1056 3RT1064 3NA3365-6 3NE3335 3RT1066 3RT1075 3RT1056 3RT1064
3RW5243 2 x 3NA3354-6 3NE3333 3RT1064 3RT1064 2 x 3NA3354-6 3NE3333 3RT1075 3RT1075 3RT1064 3RT1064
3RW5244 2 x 3NA3354-6 3NE3336 3RT1065 3RT1065 2 x 3NA3354-6 3NE3336 3RT1076 3RT1076 3RT1065 3RT1065
3RW5245 2 x 3NA3365-6 3NE3336 3RT1075 3RT1075 2 x 3NA3365-6 3NE3336 3TF68 3TF68 3RT1075 3RT1075
3RW5246 2 x 3NA3365-6 3NE3336 3RT1075 3RT1075 2 x 3NA3365-6 3NE3336 3TF69 3TF69 3RT1075 3RT1075
3RW5247 2 x 3NA3365-6 3NE3340-8 3RT1076 3RT1276 2 x 3NA3365-6 3NE3340-8 3TF69 3TF69 3RT1076 3RT1276
3RW5248 2 x 3NA3365-6 3NE3340-8 3TF68 3TF68 2 x 3NA3365-6 3NE3340-8 -- -- 3TF68 3TF68
Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those speci-
fied can be used at any time as smaller ones trip more quickly in
the event of a short circuit (unchanged short-circuit breaking
capacity) and thus protect the soft starter in any case. The
dimensioning of the short-circuit components must, however, be
suitable for the connected three-phase motor and the line
protection for the cables used.
For CLASS 10 applications,
applications, asas an
an alternative
alternativetoto the
thegG
gGclass
class
full-range fuses for
full-range fuses for cable
cableand
andline
lineprotection
protection3NA3
3NA3(F1),
(F1),
3RV2/3VA
3RV2/3VA motor
motor starter
starter protectors/circuit
protectors/circuit breakers also be
breakers can also be
used, possibly
possibly with
with reduced
reducedshort-circuit
short-circuitbreaking
breakingcapacity
capacity
(see page 7/61).
6/62). In these cases, optional lineline contactors
contactors can
can be
be
dispensed with.
dispensed with.
7
page 6/8.7/7.
see page
SOFT STARTERS
At 40 °C At 50 °C SD1) Article No. Price PU PS*
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional cur- three-phase motors tional cur- SET, M)
rent At At At rent At At At At
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp d
Operational voltage 200 ... 480 V
113 30 55 -- 101 30 30 75 -- 5 3RW5234-@@C@4 1 1 unit
143 37 75 -- 128 40 40 100 -- 5 3RW5235-@@C@4 1 1 unit
171 45 90 -- 153 50 50 100 -- 5 3RW5236-@@C@4 1 1 unit
210 55 110 -- 186 60 60 150 -- 5 3RW5243-@@C@4 1 1 unit
250 75 132 -- 220 60 75 150 -- 5 3RW5244-@@C@4 1 1 unit
315 90 160 -- 279 75 100 200 -- 5 3RW5245-@@C@4 1 1 unit
370 110 200 -- 328 100 125 250 -- 5 3RW5246-@@C@4 1 1 unit
470 132 250 -- 416 150 150 350 -- 5 3RW5247-@@C@4 1 1 unit
570 160 315 -- 504 150 200 400 -- 5 3RW5248-@@C@4 1 1 unit
6
32 7.5 15 18.5 28.4 7.5 10 20 25 5 3RW5216-@@C@5 1 1 unit
38 11 18.5 22 33.5 10 10 20 30 5 3RW5217-@@C@5 1 1 unit
47 11 22 30 41.6 10 10 30 40 5 3RW5224-@@C@5 1 1 unit
63 18.5 30 37 55.5 15 20 40 50 5 3RW5225-@@C@5 1 1 unit
77 22 37 45 68 20 25 50 60 5 3RW5226-@@C@5 1 1 unit
93 22 45 55 82.5 25 30 60 75 5 3RW5227-@@C@5 1 1 unit
pagepage
see 6/8.7/7.
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional cur- three-phase motors tional cur- SET, M)
rent At At At rent At At At At
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp d
Operational voltage 200 ... 600 V
113 30 55 75 101 30 30 75 100 5 3RW5234-@@C@5 1 1 unit
143 37 75 90 128 40 40 100 125 5 3RW5235-@@C@5 1 1 unit
171 45 90 110 153 50 50 100 150 5 3RW5236-@@C@5 1 1 unit
210 55 110 132 186 60 60 150 150 5 3RW5243-@@C@5 1 1 unit
250 75 132 160 220 60 75 150 200 5 3RW5244-@@C@5 1 1 unit
315 90 160 200 279 75 100 200 250 5 3RW5245-@@C@5 1 1 unit
370 110 200 250 328 100 125 250 300 5 3RW5246-@@C@5 1 1 unit
470 132 250 315 416 150 150 350 450 5 3RW5247-@@C@5 1 1 unit
570 160 315 355 504 150 200 400 500 5 3RW5248-@@C@5 1 1 unit
7
Standard delivery time SD = 1 day (d).
page 6/8. 7/7.
see page
SOFT STARTERS
At 40 °C for inside-delta circuit At 50 °C for inside-delta circuit SD1) Article No. Price PU PS*
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional cur- three-phase motors tional cur- SET, M)
rent At At At rent At At At At
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp d
Operational voltage 200 ... 480 V
196 55 110 -- 175 50 60 125 -- 5 3RW5234-@@C@4 1 1 unit
248 75 132 -- 222 75 75 150 -- 5 3RW5235-@@C@4 1 1 unit
296 90 160 -- 265 75 100 200 -- 5 3RW5236-@@C@4 1 1 unit
364 110 200 -- 322 100 125 250 -- 5 3RW5243-@@C@4 1 1 unit
433 132 250 -- 381 125 150 300 -- 5 3RW5244-@@C@4 1 1 unit
546 160 315 -- 483 150 200 400 -- 5 3RW5245-@@C@4 1 1 unit
641 200 355 -- 568 200 200 450 -- 5 3RW5246-@@C@4 1 1 unit
814 250 400 -- 721 250 250 600 -- 5 3RW5247-@@C@4 1 1 unit
987 315 560 -- 873 300 350 750 -- 5 3RW5248-@@C@4 1 1 unit
At 40 °C for inside-delta circuit At 50 °C for inside-delta circuit SD1) Article No. Price PU PS*
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional cur- three-phase motors tional cur- SET, M)
rent At At At rent At At At At
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp d
Operational voltage 200 ... 600 V
22.5 5.5 11 15 19.9 5 5 10 15 5 3RW5213-@@C@5 1 1 unit
31.5 7.5 15 18.5 28 7.5 7.5 20 25 5 3RW5214-@@C@5 1 1 unit
43.3 11 18.5 22 39 10 10 25 30 5 3RW5215-@@C@5 1 1 unit
6
55.4 15 22 30 49 15 15 30 40 5 3RW5216-@@C@5 1 1 unit
65.8 18.5 30 37 58 15 20 40 50 5 3RW5217-@@C@5 1 1 unit
81.4 22 45 45 72 20 25 50 60 5 3RW5224-@@C@5 1 1 unit
109 30 55 55 96 30 30 75 75 5 3RW5225-@@C@5 1 1 unit
133 37 75 90 118 30 40 75 100 5 3RW5226-@@C@5 1 1 unit
161 45 90 110 143 40 50 100 125 5 3RW5227-@@C@5 1 1 unit
At 40 °C for inside-delta circuit At 50 °C for inside-delta circuit SD1) Article No. Price PU PS*
SOFT STARTERS
Opera- Operating power for Opera- Rating [hp] for three-phase motors per PU (UNIT,
tional cur- three-phase motors tional cur- SET, M)
rent At At At rent At At At At
230 V 400 V 500 V 200/208 V 220/230 V 460/480 V 575/600 V
A kW kW kW A hp hp hp hp d
Operational voltage 200 ... 600 V
196 55 110 132 175 50 60 125 150 5 3RW5234-@@C@5 1 1 unit
248 75 132 160 222 75 75 150 200 5 3RW5235-@@C@5 1 1 unit
296 90 160 200 265 75 100 200 250 5 3RW5236-@@C@5 1 1 unit
364 110 200 250 322 100 125 250 300 5 3RW5243-@@C@5 1 1 unit
433 132 250 315 381 125 150 300 350 5 3RW5244-@@C@5 1 1 unit
546 160 315 355 483 150 200 400 500 5 3RW5245-@@C@5 1 1 unit
641 200 355 450 568 200 200 450 600 5 3RW5246-@@C@5 1 1 unit
814 250 400 500 721 250 250 600 800 5 3RW5247-@@C@5 1 1 unit
987 315 560 630 873 300 350 750 950 5 3RW5248-@@C@5 1 1 unit
3RW5983-0TC20
3RW5984-0TC20
Enclosure components
Hinged cover 3RW52 With cutout for -- } 3RW5950-0GL30 1 1 unit
High Feature
HMI module
3RW5950-0GL30
7
With cutout for -- } 3RW5950-0GL40 1 1 unit
Standard HMI
SOFT STARTERS
module
3RW5950-0GL40
Communication modules
Communica- 3RW52 PROFINET -- } 3RW5980-0CS00 1 1 unit
tion module Standard
PROFIBUS -- } 3RW5980-0CP00 1 1 unit
EtherNet/IP -- } 3RW5980-0CE00 1 1 unit
3RW5980-0CS00
3RW5980-0CR00
3RW5980-0HF00
Standard -- } 3RW5980-0HS00 1 1 unit
3RW5980-0HS00
IP65 door 3RW52 IP65 For HMI } 3RW5980-0HD00 1 1 unit
mounting kit modules
for HMI
modules
6
3RW5980-0HD00
Connecting cables
HMI 3RW52 5 m, round For door } 3RW5980-0HC60 1 1 unit
connection 2.5 m, round mounting } 3UF7933-0BA00-0 1 1 unit
cable
1.0 m, round } 3UF7937-0BA00-0 1 1 unit
0.5 m, round } 3UF7932-0BA00-0 1 1 unit
3UF793.-0BA00-0
7
3UF7931-0AA00-0
Further accessories
Push-in lugs -- Two lugs are For HMI 2 3ZY1311-0AA00 1 10 units
for wall required per modules and
mounting device communica-
tion modules
3ZY1311-0AA00
Blank labels
Unit labeling -- 20 mm x For SIRIUS 20 3RT2900-1SB20 100 340 units
plates1) 7 mm, devices
titanium gray
IC01_00181
3RT2900-1SB20
1)
PC labeling systems for individual inscription of unit labeling plates are
available from: murrplastik Systemtechnik GmbH (see page 16/15).
■ Overview
More information
Homepage, www.siemens.com/soft-starter
Homepage, see www.usa.siemens.com/soft-starter Simulation
Simulation Tool
Tool for
for Soft
Soft Starters
Starters (STS),
(STS), see
see page
page 6/8
7/7 or
or
Industry Mall,
Mall, see
see www.siemens.com/product?3RW50
www.siemens.com/product?3RW50 https://support.industry.siemens.com/cs/ww/en/view/101494917
https://support.industry.siemens.com/cs/ww/en/view/101494917
TIA Selection
Industry Tool
Online Cloud (SIOS)
Support (TST Cloud), see see
topic page, SIRIUS Soft
SIRIUS Soft Starter
Starter ES
ES(TIA
(TIA Portal)
Portal),for
see page 14/5 see page 14/5
diagnostics,
https://support.industry.siemens.com/cs/ww/en/view/109747404
https://support.industry.siemens.com/cs/ww/en/view/109747404
2 HMI modules
3 Communication modules
4
4 Box terminal blocks
5 Terminal covers for box terminals
6 Terminal covers for cable lugs
and busbar connections
1
7 Fan cover
8 Push-in lugs for wall mounting
9 IP65 door mounting kit
7
11 COM connecting cable
IC01_00571
SOFT STARTERS
7 8
2
9
4
5 6
10
3RW50
3RW50 Basic
Basic Performance soft starters with accessories (see page
accessories (see page7/81),
6/82),for
forexpansion
expansionwith
withHMI
HMImodule
moduleororcommunication
communicationmodule
module
■ Benefits
6
Product characteristics / function Performance features / benefits
Hybrid switching devices and two-phase motor control Minimum power loss and optimized motor control by avoiding DC components
Small and compact design Space-saving, clearly arranged control panel layout
TIA-Integration – communication modules and HMI modules optional Efficient configuration and maximum flexibility in automation engineering
7
Motor overload and intrinsic device protection without additional wiring Adjustable trip classes, integrated diagnostics functions
SOFT STARTERS
Wide range for control supply and main voltage Low variance, high system availability even with weak supply networks
Certified according to ATEX/IECEx directive Suitable for the starting of explosion-proof motors with "increased safety" type
of protection
■ Technical specifications
More information
Technical specifications,see
Technical specifications, see FAQs,
FAQs, see
see https://support.industry.siemens.com/cs/ww/en/ps/25252/faq
https://support.industry.siemens.com/cs/ww/en/ps/25252/faq
https://support.industry.siemens.com/cs/ww/en/ps/25252/td
https://support.industry.siemens.com/cs/ww/en/ps/25252/td Simulation Tool
Simulation Tool for
for Soft
Soft Starters
Starters (STS),
(STS), see
see page
page 6/8
7/7 or
or
Equipment Manual
Manual “SIRIUS
"SIRIUS 3RW50 Soft Starters",
Starter”, see
see https://support.industry.siemens.com/cs/ww/en/view/101494917
https://support.industry.siemens.com/cs/ww/en/view/101494917
https://support.industry.siemens.com/cs/ww/en/view/109753750
https://support.industry.siemens.com/cs/ww/en/view/109753750
7
• During transport 2K2, 2C1, 2S1, 2M2 (max. height of fall 0.3 m)
1)
Derating from 11 000
000 m,
m,see
seecharacteristic
characteristiccurve
curveon
onpage
page6/8.
7/7.
SOFT STARTERS
2) Note derating above 40 °C.
6
Minimum load [% of IM]1) % 15
Maximum cable length between soft starter and motor m 800
1)
Relative to the smallest adjustable Ie.
7
SOFT STARTERS
Type 10
3RW5072 3RW5073 3RW5074 3RW5075 3RW5076 3RW5077
Rated operational current Ie A 210 250 315 370 470 570
Power electronics
Load rating with rated operational current Ie
IEC + UL/CSA, individual mounting at 40/50/60 °C, A 210/186/170 250/220/200 315/279/255 370/328/300 470/416/380 570/504/460
AC-53a
Permissible rated motor current and starts/h
Normal starting (CLASS 10A)
7
Rated motor current IM, Tu = 40/50/60 °C A 210/186/170 250/220/200 315/279/255 370/328/300 470/416/380 570/504/460
ON period = 70%; motor protection activated
SOFT STARTERS
• 300% IM
- Start-up time 5 s 1/h 43 43 43 43 43 28
- Start-up time 10 s 1/h 18 18 18 18 18 11
• 350% IM
- Start-up time 5 s 1/h 28 28 28 28 28 16
- Start-up time 10 s 1/h 8 10 10 10 10 4
Normal starting (CLASS 10E)
Rated motor current IM, Tu = 40/50/60 °C A 210/186/170 250/220/200 315/279/255 370/328/300 470/416/380 570/504/460
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 21 21 21 21 20 21
- Start-up time 40 s 1/h 8 8 8 8 7 8
• 350% IM
- Start-up time 20 s 1/h 8 13 12 13 12 13
- Start-up time 40 s 1/h -- 4 4 4 2 4
Heavy starting (CLASS 20E)
Rated motor current IM, Tu = 40/50/60 °C A 162/146/130 200/180/160 219/195/171 258/230/202 272/254/218 284/262/240
ON period = 70%; motor protection activated
• 300% IM
- Start-up time 20 s 1/h 10 10 10 10 10 10
- Start-up time 40 s 1/h 4 4 4 4 4 4
• 350% IM
- Start-up time 20 s 1/h 7 7 7 7 7 7
- Start-up time 40 s 1/h 2.5 2.5 2.5 2.5 2.5 2.5
Adjustable rated motor current IM
• Minimum/maximum A 90/210 100/250 135/315 160/370 200/470 240/570
Q1
Q11
NSB0_01902
M
3~
6
ToC
coordina- 1
tion "1"
3RW5055 3VA2220-7MN32-0AA0 20 3VA2220-7MN32-0AA0 20
3RW5056 3VA2220-7MN32-0AA0 20 3VA2220-7MN32-0AA0 20
3RW5072 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65
3RW5073 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65
3RW5074 3VA2440-7MN32-0AA0 65 3VA2440-7MN32-0AA0 65
3RW5075 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65
3RW5076 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65
3RW5077 3VA2580-6HN32-0AA0 65 3VA2580-6HN32-0AA0 65
Note:
The service factor or measurement inaccuracies have been
taken into account, for example, for the selection of the specified
motor starter protectors/circuit breakers; the specified short-
circuit breaking capacities Iq in kA are covered by combination
tests. Smaller motor starter protectors/circuit breakers than
7
F1
Q21
Q11
NSB0_01904
M
3~
Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those speci-
7
fied can be used at any time as smaller ones trip more quickly in
the event of a short circuit (unchanged short-circuit breaking
SOFT STARTERS
capacity) and thus protect the soft starter in any case. The
dimensioning of the short-circuit components must, however, be
suitable for the connected three-phase motor and the line
protection for the cables used.
F’1
Q21
Q11
NSB0_01905
M
3~
6
up to 600 V up to 480 V up to 600 V
Q11 F’1 Q21 Q21
Type Type Type Type
Type of ToC Inline circuit
coordina- 2
tion "2"
3RW5055 3NE1227-0 3RT1055 3RT1055
3RW5056 3NE1230-0 3RT1056 3RT1064
3RW5072 3NE1230-2 3RT1064 3RT1064
3RW5073 3NE1331-0 3RT1065 3RT1065
3RW5074 3NE1333-2 3RT1075 3RT1075
3RW5075 3NE1334-2 3RT1075 3RT1075
3RW5076 3NE1436-2 3RT1076 3RT1076
3RW5077 3NE1437-2 3TF68 3TF68
Note:
The specified short-circuit breaking capacities Iq in kA are
7
capacity) and thus protect the soft starter in any case. The
dimensioning of the short-circuit components must, however, be
suitable for the connected three-phase motor and the line
protection for the cables used.
F1
Q21
F3
Q11
NSB0_01906
M
3~
Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those speci-
7
fied can be used at any time as smaller ones trip more quickly in
the event of a short circuit (unchanged short-circuit breaking
SOFT STARTERS
capacity) and thus protect the soft starter in any case. The
dimensioning of the short-circuit components must, however, be
suitable for the connected three-phase motor and the line
protection for the cables used.
For CLASS 10 applications, as an
applications, as an alternative
alternativeto
tothe
thegG gGclass
class
full-range fuses
full-range fuses for
for cable
cableand
andline
lineprotection
protection3NA3
3NA3(F1),(F1),
circuit breakers
3VA circuit breakers can
canalso
alsobe
beused,
used,possibly
possiblywith
withreduced
reduced
short-circuit breaking
breaking capacity
capacity(see
(seepage
page7/76).
6/77).InInthese
thesecases
cases,
optional line
optional line contactors
contactors can
can be
bedispensed
dispensedwith.
with.
3RW5055 3RW5075
6
210 55 110 132 186 40 50 150 -- S12 5 3RW5072-@@B@4 1 1 unit
250 75 132 160 220 50 60 150 -- S12 5 3RW5073-@@B@4 1 1 unit
315 90 160 200 279 60 75 200 -- S12 5 3RW5074-@@B@4 1 1 unit
370 110 200 250 328 75 100 250 -- S12 5 3RW5075-@@B@4 1 1 unit
470 132 250 315 416 100 125 350 -- S12 5 3RW5076-@@B@4 1 1 unit
570 160 315 355 504 125 150 400 -- S12 5 3RW5077-@@B@4 1 1 unit
see page
page 7/7.
6/8.
SOFT STARTERS
3RW5985-0FC00
Box terminal block
Box terminal 3RW505 (2x) Up to 70 mm2 -- } 3RT1955-4G 1 1 unit 41B
block for round Up to 120 mm2 } 3RT1956-4G 1 1 unit 41B
and ribbon
cables 3RW507 (2x) Up to 240 mm2 } 3RT1966-4G 1 1 unit 41B
(with auxiliary
conductor
3RT1956-4G connection)
Terminal covers
Covers for 3RW505 (2x) -- -- } 3RT1956-4EA2 1 1 unit 41B
box terminals 3RW507 (2x) -- -- 2 3RT1966-4EA2 1 1 unit 41B
6
3RT1956-4EA2
Covers for 3RW505 (2x) -- -- } 3RT1956-4EA1 1 1 unit 41B
cable lugs and 3RW507 (2x) -- -- 2 3RT1966-4EA1 1 1 unit 41B
busbar
connections
3RT1956-4EA1
Communication modules
Communica- 3RW50 PROFINET -- } 3RW5980-0CS00 1 1 unit 42S
tion module Standard
PROFIBUS } 3RW5980-0CP00 1 1 unit 42S
7
EtherNet/IP } 3RW5980-0CE00 1 1 unit 42S
Modbus RTU } 3RW5980-0CR00 1 1 unit 42S
}
SOFT STARTERS
Modbus TCP 3RW5980-0CT00 1 1 unit 42S
3RW5980-0CS00
COM 3RW50 0.3 m -- } 3RW5900-0CC00 1 1 unit 42S
connection
cable
3RW5900-0CC00 For mounting
laterally on the
device
3RW5980-0HF00
Standard -- } 3RW5980-0HS00 1 1 unit 42S
3RW5980-0HS00
IP65 door 3RW50 IP65 For HMI } 3RW5980-0HD00 1 1 unit 42S
mounting kit modules
for HMI
modules
6
3RW5980-0HD00
Connecting cables
HMI 3RW50 5 m, round For door } 3RW5980-0HC60 1 1 unit 42S
connection 2.5 m, round mounting } 3UF7933-0BA00-0 1 1 unit 42J
cable
1.0 m, round } 3UF7937-0BA00-0 1 1 unit 42J
0.5 m, round } 3UF7932-0BA00-0 1 1 unit 42J
3UF793.-0BA00-0
7
Further accessories
Push-in lugs -- Two lugs are For HMI 2 3ZY1311-0AA00 1 10 units 41L
SOFT STARTERS
3RT2900-1SB20
1) PC labeling systems for individual inscription of unit labeling plates are
available from: murrplastik Systemtechnik GmbH (see page 16/15).
Overview
More information
Homepage, www.siemens.com/soft-starter
Homepage, see www.usa.siemens.com/soft-starter TIA
TIA Selection
Selection Tool Cloud
Cloud (TST Cloud), see
Industry Mall,
Mall, see
see www.siemens.com/product?3RW40
www.siemens.com/product?3RW40 https://www.siemens.com/tstcloud/?node=3rw40
https://www.siemens.com/tstcloud/?node=3rw40
Simulation Tool
Simulation Tool for
for Soft
Soft Starters
Starters (STS),
(STS), see
see page
page 6/8
7/7 or
or
https://support.industry.siemens.com/cs/ww/en/view/101494917
https://support.industry.siemens.com/cs/ww/en/view/101494917
7
1
SOFT STARTERS
8
IC01_00539
3RW40 Basic
3RW40 Basic Performance
Performance soft starters with accessories
accessories (see
(see page
page7/92)
6/94)
■ Benefits
Small and compact design Space-saving, clearly arranged control panel layout
Motor overload and intrinsic device protection without additional wiring Adjustable trip classes, integrated diagnostics functions
Integrated in the SIRIUS modular system Link modules to motor starter protectors
6
Hybrid switching devices and two-phase motor control Minimum power loss and optimized motor control by avoiding DC components
Certified according to ATEX Directive 94/9/EC Suitable for the starting of explosion-proof motors with "increased safety" type
of protection EEx e.
Technical specifications
More information
Technical specifications,see
Technical specifications, see FAQs,
FAQs, see
see https://support.industry.siemens.com/cs/ww/en/ps/25251/faq
https://support.industry.siemens.com/cs/ww/en/ps/25251/faq
https://support.industry.siemens.com/cs/ww/en/ps/25251/td
https://support.industry.siemens.com/cs/ww/en/ps/25252/td Simulation Tool
Simulation Tool for
for Soft
Soft Starters
Starters (STS),
(STS), see
see page
page 6/8
7/7 or
Equipment Manual
Manual “SIRIUS
"SIRIUS 3RW30/3RW40 SoftStarters",
3RW30/3RW40 Soft Starter”, see
see https://support.industry.siemens.com/cs/ww/en/view/101494917
https://support.industry.siemens.com/cs/ww/en/view/101494917
https://support.industry.siemens.com/cs/ww/en/view/38752095
https://support.industry.siemens.com/cs/ww/en/view/38752095
D
W
NSB0_00649a
(for 3RW402. ... 3RW404.) 90° 90°
6
7
1) In the case of deviations, please observe derating, see Equipment Manual
in the chapter "Configuring".
SOFT STARTERS
Type Terminal 3RW402., 3RW403., 3RW404.
Control electronics
Rated values
Rated control supply voltage A1/A2 V 24 AC/DC 110 ... 230 AC/DC
• Tolerance % ± 20 -15/+10
Rated frequency Hz 50/60
• Tolerance % ± 10
6
2)
Current limiting on soft starter set to 300% IM, Tu = 40/50 °C. Maximum installation vertical. The quoted switching frequencies do not apply for
adjustable rated motor current IM dependent on CLASS setting. automatic mode. Factors for permissible switching frequency in other
mounting position, direct mounting, side-by-side mounting, and
implementation of optional auxiliary fan, see Equipment Manual in the
chapter "Configuring".
- Rated motor current IM2), start-up time 4 s A 45/42 63/58 72/62 80/73 106/98
- Starts per hour3) 1/h 26/26 15/15 15/15 15/15 10/10
• For heavy starting (CLASS 20) at 40/50 °C
- Rated motor current IM2), start-up time 6 s A 38/34 46/42 50/46 64/58 77/70
- Starts per hour3) 1/h 30/30 31/31 34/34 23/23 23/23
- Rated motor current IM2), start-up time 8 s A 38/34 46/42 50/46 64/58 77/70
- Starts per hour3) 1/h 21/21 22/22 24/24 16/16 16/16
1) Measurement at 60 °C according to UL/CSA not required. 3) For intermittent duty S4 with ON period = 30%, Tu = 40/50 °C, stand-alone
2)
Current limiting on soft starter set to 300% IM, Tu = 40/50 °C. Maximum installation vertical. The quoted switching frequencies do not apply for
adjustable rated motor current IM dependent on CLASS setting. automatic mode. Factors for permissible switching frequency in other
mounting position, direct mounting, side-by-side mounting, and
implementation of optional auxiliary fan, see Equipment Manual in the
chapter "Configuring".
Q1
Q11
NSB0_01902
M
3~
ToC
coordina- 1
tion "1"
3RW4024 3RV2021-4AA10 55 3RV2021-4AA10 10
3RW4026 3RV2021-4DA10 55 3RV2021-4DA10 10
3RW4027 3RV2021-4EA10 55 3RV2021-4EA10 10
3RW4028 3RV2021-4FA10 55 3RV2021-4FA10 10
3RW4036 3RV2031-4WA10 10 3RV2031-4WA10 10
3RW4037 3RV2031-4JA10 10 3RV2031-4JA10 5
3RW4038 3RV2031-4KA10 10 3RV2031-4KA10 5
3RW4046 3RV2041-4RA10 11 3RV2041-4YA10 5
3RW4047 3RV2041-4MA10 11 3RV2041-4MA10 5
Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller motor starter protec-
tors/circuit breakers than those specified can be used at any
time as smaller ones trip more quickly in the event of a short
7
circuit (unchanged short-circuit breaking capacity) and thus
protect the soft starter in any case. The dimensioning of the
short-circuit components must, however, be suitable for the
SOFT STARTERS
connected three-phase motor and the line protection for the
cables used.
F’1
Q21
Q11
NSB0_01905
M
3~
Note:
7
fied can be used at any time as smaller ones trip more quickly in
the event of a short circuit (unchanged short-circuit breaking
capacity) and thus protect the soft starter in any case. The
dimensioning of the short-circuit components must, however, be
suitable for the connected three-phase motor and the line
protection for the cables used.
F1
Q21
F3
Q11
NSB0_01906
M
3~
Soft starters gG class fuse aR class fuse Cylindrical Line contactor (optional)
fuses
6
for systems up for systems up for systems up for systems up for systems for systems for systems for systems
to 600 V to 600 V to 600 V to 600 V up to 480 V up to 400 V up to 480 V up to 600 V
Q11 F1 F3 F3 F3 F3 Q21 Q21 Q21
Type Type Type Type Type Type Type Type Type
Type of ToC Inline circuit
coordina- 2
tion "2"
3RW4024 3NA3820-6 -- 3NE4101 3NE8015-1 3NC2240 3RT2025 3RT2025/ 3RT2025
3RT2018
(in size S00)
3RW4026 3NA3822-6 -- 3NE4102 3NE8017-1 3NC2263 3RT2026 3RT2027 3RT2037
3RW4027 3NA3824-6 -- 3NE4118 3NE8018-1 3NC2280 3RT2027 3RT2028 3RT2037
3RW4028 3NA3824-6 -- 3NE4118 3NE8020-1 3NC2280 3RT2028 3RT2035 3RT2037
3RW4036 3NA3130-6 -- 3NE4120 3NE8020-1 3NC2280 3RT2036 3RT2036 3RT2038
3RW4037 3NA3132-6 -- 3NE4121 3NE8021-1 -- 3RT2037 3RT2037 3RT2046
3RW4038 3NA3132-6 3NE3221 -- 3NE8022-1 -- 3RT2038 3RT2038 3RT2046
3RW4046 3NA3136-6 3NE3222 -- 3NE8022-1 -- 3RT2045 3RT2045 3RT2047
3RW4047 3NA3136-6 3NE3224 -- 3NE8024-1 -- 3RT2047 3RT2047 3RT1054
7
Note:
The specified short-circuit breaking capacities Iq in kA are
SOFT STARTERS
covered by combination tests. Smaller fuses than those speci-
fied can be used at any time as smaller ones trip more quickly in
the event of a short circuit (unchanged short-circuit breaking
capacity) and thus protect the soft starter in any case. The
dimensioning of the short-circuit components must, however, be
suitable for the connected three-phase motor and the line
protection for the cables used.
For CLASS 10 applications,
applications, as as an
an alternative
alternativeto
tothe
thegG
gGclass
class
full-range fuses
full-range fuses for
for cable
cableand
andline
lineprotection
protection3NA3
3NA3(F1),
(F1),
3RV2 motor starter protectors can also be be used,
used, possibly
possiblywith
with
reduced short-circuit
reduced short-circuit breaking
breakingcapacity
capacity(see
(seepage
page7/87).
6/88).InIn
cases, optional
these cases, optional line
linecontactors
contactorscancanbebedispensed
dispensedwith.
with.
3RW ambient temperature 40 °C 3RW ambient temperature 50 °C Size SD1) Article No. Price PU PS*
Rated values of Rated values of per PU (UNIT,
three-phase motors three-phase motors SET, M)
Opera- Rating at Opera- Rating at
tional operational voltage Ue tional operational voltage Ue
current Ie 230 V 400 V 500 V current Ie 200 V 230 V 460 V 575 V
A kW kW kW A hp hp hp hp d
Rated operational voltage Ue 200 ... 480 V
12.5 3 5.5 -- 11 3 3 7.5 -- S0 2 3RW4024-@BB@4 1 1 unit
6
• Screw terminals 1
• Spring-loaded terminals2) 2
3RW ambient temperature 40 °C 3RW ambient temperature 50 °C Size SD1) Article No. Price PU PS*
Rated values of Rated values of per PU (UNIT,
three-phase motors three-phase motors SET, M)
Opera- Rating at Opera- Rating at
tional operational voltage Ue tional operational voltage Ue
current Ie 230 V 400 V 500 V current Ie 200 V 230 V 460 V 575 V
A kW kW kW A hp hp hp hp d
Rated operational voltage Ue 200 ... 480 V,
with thermistor motor protection,
rated control supply voltage Us 24 V AC/DC
6
12.5 3 5.5 -- 11 3 3 7.5 -- S0 5 3RW4024-@TB04 1 1 unit
25 5.5 11 -- 23 5 5 15 -- S0 5 3RW4026-@TB04 1 1 unit
32 7.5 15 -- 29 7.5 7.5 20 -- S0 5 3RW4027-@TB04 1 1 unit
38 11 18.5 -- 34 10 10 25 -- S0 5 3RW4028-@TB04 1 1 unit
45 11 22 -- 42 10 15 30 -- S2 5 3RW4036-@TB04 1 1 unit
63 18.5 30 -- 58 15 20 40 -- S2 5 3RW4037-@TB04 1 1 unit
72 22 37 -- 62 20 20 40 -- S2 5 3RW4038-@TB04 1 1 unit
80 22 45 -- 73 20 25 50 -- S3 5 3RW4046-@TB04 1 1 unit
106 30 55 -- 98 30 30 75 -- S3 5 3RW4047-@TB04 1 1 unit
Rated operational voltage Ue 400 ... 600 V,
with thermistor motor protection,
rated control supply voltage Us 24 V AC/DC
12.5 -- 5.5 7.5 11 -- -- 7.5 10 S0 5 3RW4024-@TB05 1 1 unit
25 -- 11 15 23 -- -- 15 20 S0 5 3RW4026-@TB05 1 1 unit
32 -- 15 18.5 29 -- -- 20 25 S0 5 3RW4027-@TB05 1 1 unit
38 -- 18.5 22 34 -- -- 25 30 S0 5 3RW4028-@TB05 1 1 unit
45 -- 22 30 42 -- -- 30 40 S2 5 3RW4036-@TB05 1 1 unit
63 -- 30 37 58 -- -- 40 50 S2 5 3RW4037-@TB05 1 1 unit
7
72 -- 37 45 62 -- -- 40 60 S2 5 3RW4038-@TB05 1 1 unit
80 -- 45 55 73 -- -- 50 60 S3 5 3RW4046-@TB05 1 1 unit
SOFT STARTERS
106 -- 55 75 98 -- -- 75 75 S3 5 3RW4047-@TB05 1 1 unit
3RV2925-5AB
3RT2946-4F
Covers for soft starters
Terminal covers for box terminals
3RW403. S2 Additional touch protection to be fitted } 3RT2936-4EA2 1 1 unit
3RW404. S3 at the box terminals } 3RT2946-4EA2 1 1 unit
(two units required per device)
3RT2936-4EA2
Terminal covers for cable lugs and busbar connections
3RW404. S3 For complying with the voltage clear- 5 3RT1946-4EA1 1 1 unit
ances and as touch protection if box
terminal is removed
(two units required per device)
7
SOFT STARTERS
3RT1946-4EA1
Sealing covers
3RW402. to S0, S2, -- 5 3RW4900-0PB10 1 1 unit
3RW404. S3
3RW4900-0PB10
For motor For soft Version SD Article No. Price PU (UNIT, PS*
starter starters per PU SET, M)
protectors
Size Size d
Standard mounting rail adapters
For mechanical fixing of motor
starter protector and soft starter;
for snapping onto standard
mounting rail or for screw fixing
S2 S2 Single-unit packaging 2 3RA2932-1CA00 1 1 unit
6
3RW49..-8VB00
For soft starters Motor starter protectors SD Article No. Price PU (UNIT, PS*
Type Size Size per PU SET, M)
d
Link modules to motor starter protectors1)
Screw terminals
7
SOFT STARTERS
3RA2921-2GA00
1)
Can be used in size S0 up to 32 A.
Can be used in size S2 up to 65 A in combination with 3RA2932-1CA00
standard mounting rail adapter (specially for soft starters).
Can be used in size S3 only with mounting plate.
3RT2900-1SB20
1)
PC labeling systems for individual inscription of unit labeling plates are
available from: murrplastik Systemtechnik GmbH (see page 16/14).
Overview
More information
Homepage, see
Homepage, see www.usa.siemens.com/soft-starter
www.siemens.com/soft-starter Simulation
Simulation Tool
Tool for
for Soft
Soft Starters
Starters (STS),
(STS), see
see page
page 6/8
7/7 or
Industry
Industry Mall,
Mall, see
see www.siemens.com/product?3RW
www.siemens.com/product?3RW https://support.industry.siemens.com/cs/ww/en/view/101494917
https://support.industry.siemens.com/cs/ww/en/view/101494917
TIA
TIA Selection
Selection Tool
Tool Cloud
Cloud (TST
(TST Cloud),
Cloud),see
see SIRIUS Soft
SIRIUS Soft Starter
Starter ES
ES (TIA
(TIA Portal)
Portal),for
see page 14/5 see page 14/5
diagnostics,
https://www.siemens.com/tstcloud/?node=3rw30
https://www.siemens.com/tstcloud/?node=3rw30
1
SOFT STARTERS
IC01_00538
3RW30 Basic
Basic Performance soft starters
starters with accessories
accessories (see
(see page
page7/103)
6/105)
Benefits
Small and compact design Space-saving, clearly arranged control panel layout
Integrated in the SIRIUS modular system Link modules to motor starter protectors
6
Hybrid switching devices and two-phase motor control Minimum power loss and optimized motor control by avoiding DC components
Technical specifications
More information
Equipment Manual
Equipment Manual “SIRIUS
"SIRIUS 3RW30/3RW40
3RW30/3RW40 Soft
Soft Starters",
Starters”,see
see Catalog
Catalog LV
LV 10,
10, see
see www.siemens.com/lowvoltage/lv10
www.siemens.com/lowvoltage/lv10
https://support.industry.siemens.com/cs/ww/en/view/38752095
https://support.industry.siemens.com/cs/ww/en/view/38752095
FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16213/faq
https://support.industry.siemens.com/cs/ww/en/ps/16213/faq
7
H
SOFT STARTERS
Permissible ambient temperature
During operation °C -25 ... +60; (derating from +40)
During storage °C -40 ... +80
Weight kg 0.58 0.69 1.20 1.71
Permissible mounting position1) 10° 10°
(auxiliary fan not possible) 10° 10°
NSB0_01897
1)
In the case of deviations, please observe derating, see Equipment Manual
in the chapter "Configuring".
Power loss
• In operation after completed starting with uninterrupted rated operational W 0.25 0.5 1 2 4
current (40 °C) approx.
• During starting with 300% IM (40 °C) W 24 52 80 80 116
Permissible rated motor current and starts per hour
• For normal starting (CLASS 10) at 40/50 °C
- Rated motor current IM2), start-up time 3 s A 3.6/3.3 6.5/6.0 9/8 12.5/12.0 17.6/17.0
- Starts per hour3) 1/h 200/150 87/60 50/50 85/70 62/46
- Rated motor current IM2), start-up time 4 s A 3.6/3.3 6.5/6.0 9/8 12.5/12.0 17.6/17.0
- Starts per hour3) 1/h 150/100 64/46 35/35 62/47 45/32
1) Measurement at 60 °C according to UL/CSA not required. 3) For intermittent duty S4 with ON period = 30%, Tu = 40/50 °C, stand-alone
2)
At 300% IM, Tu = 40/50 °C. installation vertical. The quoted switching frequencies do not apply for
automatic mode.
Power loss
• In operation after completed starting with uninterrupted rated operational W 8 13 19
current (40 °C) approx.
SOFT STARTERS
D
W
NSB0_01897
Permissible installation altitude m 5 000
(Derating
(Derating from
from 1 000,
000, see
see characteristic
characteristiccurve
curveon
onpage
page6/8)
7/7)
Degree of protection acc. to IEC 60529 IP00
Control electronics
Rated values
Rated control supply voltage V 24 ... 230 AC/DC
6
• Tolerance % ± 10
Rated frequency at AC Hz 50/60
• Tolerance % ± 10
Power electronics
Rated operational voltage V AC 200 ... 400
Tolerance % ± 10
Rated frequency Hz 50/60
Tolerance % ± 10
Uninterrupted duty (% of Ie) % 100
Minimum load1) (% of Ie); at 40 °C % 9
Maximum conductor length between soft starter and motor m 1002)
Load rating with rated operational current Ie
• According to IEC and UL/CSA, individual mounting A 3/2.6/2.2
at 40/50/60 °C, AC-53a
• According to IEC and UL/CSA, side-by-side mounting A 2.6/2.2/1.8
at 40/50/60 °C, AC-53a
Power loss
7
• In operation after completed starting with uninterrupted rated W 6.5
operational current (40 °C) approx.
SOFT STARTERS
• With utilization of maximum switching frequency W 3
Permissible starts per hour
(cannot be increased by using a fan)
• For intermittent duty S4 Tu = 40 °C, stand-alone installation vertical 1/h 1 500
• ON period = 70% for 300% Ie 1/s 0.2
Dead time after uninterrupted duty
with Ie before restart s 0
1)
The rated motor current (specified on the motor's name plate) should at
least amount to the specified percentage of the SIRIUS soft starter unit's
rated operational current Ie.
2) If this value is exceeded, problems with line capacities may arise, which
can result in false firing.
Q1
Q11
NSB0_01902
M
3~
ToC
coordina- 1
tion "1"
3RW3003 3RV2011-1EA10 50
3RW3013 3RV2011-1FA10 5
3RW3014 3RV2011-1HA10 5
3RW3016 3RV2011-1JA10 5
3RW3017 3RV2011-1KA10 5
3RW3018 3RV2021-4BA10 5
3RW3026 3RV2021-4DA10 55
3RW3027 3RV2021-4EA10 55
3RW3028 3RV2021-4FA10 55
3RW3036 3RV2031-4WA10 10
3RW3037 3RV2031-4JA10 10
3RW3038 3RV2031-4KA10 10
3RW3046 3RV2041-4RA10 11
3RW3047 3RV2041-4MA10 11
Note:
7
F1
Q21
Q11
NSB0_01904
M
3~
6
Q11 F1 Q21 Q21
Type Type Type Type
Type of ToC Inline circuit
coordina- 1
tion "1"
3RW30031) 3NA38052) 3RT2015 3RT2015
3RW3013 3NA3803-6 3RT2015 3RT2015
3RW3014 3NA3805-6 3RT2015 3RT2016
3RW3016 3NA3807-6 3RT2016 3RT2017
3RW3017 3NA3810-6 3RT2018 3RT2025
3RW3018 3NA3814-6 3RT2026 3RT2026
3RW3026 3NA3822-6 3RT2026 3RT2027
3RW3027 3NA3824-6 3RT2027 3RT2028
3RW3028 3NA3824-6 3RT2028 3RT2035
3RW3036 3NA3130-6 3RT2036 3RT2036
3RW3037 3NA3132-6 3RT2037 3RT2037
3RW3038 3NA3132-6 3RT2038 3RT2038
7
3RW3046 3NA3136-6 3RT2045 3RT2045
3RW3047 3NA3136-6 3RT2047 3RT2047
1)
SOFT STARTERS
Iq = 50 kA at 400 V.
2)
3NA3805-1 (NH00), 5SB261 (DIAZED), 5SE2201-6 (NEOZED).
Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those speci-
fied can be used at any time as smaller ones trip more quickly in
the event of a short circuit (unchanged short-circuit breaking
capacity) and thus protect the soft starter in any case. The
dimensioning of the short-circuit components must, however, be
suitable for the connected three-phase motor and the line
protection for the cables used.
F’1
Q21
Q11
NSB0_01905
M
3~
1) Iq = 50 kA at 400 V.
2)
No SITOR fuse required!
Alternatively: 3NA3803 (NH00), 5SB221 (DIAZED), 5SE2206 (NEOZED).
Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those speci-
fied can be used at any time as smaller ones trip more quickly in
the event of a short circuit (unchanged short-circuit breaking
capacity) and thus protect the soft starter in any case. The
dimensioning of the short-circuit components must, however, be
suitable for the connected three-phase motor and the line
protection for the cables used.
F1
Q21
F3
Q11
NSB0_01906
M
3~
Soft starters gG class fuse aR class fuse Cylindrical fuses Line contactor (optional)
for systems for systems for systems for systems for systems for systems for systems
6
up to 480 V up to 480 V up to 480 V up to 480 V up to 480 V up to 400 V up to 480 V
Q11 F1 F3 F3 F3 F3 Q21 Q21
Type Type Type Type Type Type Type Type
Type of ToC Inline circuit
coordina- 2
tion "2"
3RW30031) 3NA38052) -- -- 3NE8015-1 3NC1010 3RT2015 3RT2015
3RW3013 3NA3803-6 -- 3NE4101 3NE8015-1 3NC2220 3RT2015 3RT2015
3RW3014 3NA3805-6 -- 3NE4101 3NE8015-1 3NC2220 3RT2015 3RT2016
3RW3016 3NA3807-6 -- 3NE4101 3NE8015-1 3NC2220 3RT2016 3RT2017
3RW3017 3NA3810-6 -- 3NE4101 3NE8015-1 3NC2250 3RT2018 3RT2025
3RW3018 3NA3814-6 -- 3NE4101 3NE8003-1 3NC2263 3RT2026 3RT2026
3RW3026 3NA3822-6 -- 3NE4102 3NE8017-1 3NC2263 3RT2026 3RT2027
3RW3027 3NA3824-6 -- 3NE4118 3NE8018-1 3NC2280 3RT2027 3RT2028
3RW3028 3NA3824-6 -- 3NE4118 3NE8020-1 3NC2280 3RT2028 3RT2035
3RW3036 3NA3130-6 -- 3NE4120 3NE8020-1 3NC2280 3RT2036 3RT2036
3RW3037 3NA3132-6 -- 3NE4121 3NE8021-1 -- 3RT2037 3RT2037
7
3RW3038 3NA3132-6 3NE3221 -- 3NE8022-1 -- 3RT2038 3RT2038
3RW3046 3NA3136-6 3NE3222 -- 3NE8022-1 -- 3RT2045 3RT2045
3RW3047 3NA3136-6 3NE3224 -- 3NE8024-1 -- 3RT2047 3RT2047
SOFT STARTERS
1) Iq = 50 kA at 400 V.
2)
3NA3805-1 (NH00), 5SB261 (DIAZED).
Note:
The specified short-circuit breaking capacities Iq in kA are
covered by combination tests. Smaller fuses than those speci-
fied can be used at any time as smaller ones trip more quickly in
the event of a short circuit (unchanged short-circuit breaking
capacity) and thus protect the soft starter in any case. The
dimensioning of the short-circuit components must, however, be
suitable for the connected three-phase motor and the line
protection for the cables used.
For CLASS 10 applications,
applications, as as an
an alternative
alternativeto tothe
thegG
gGclass
class
full-range
full-range fuses
fuses for
for cable
cableand
andline
lineprotection
protection3NA3
3NA3(F1),
(F1),3RV2
3RV2
motor starter protectors/circuit breakers
breakers can
can also
alsobebeused,
used,
possibly
possibly with
with reduced
reducedshort-circuit
short-circuitbreaking
breakingcapacity
capacity
(see page 6/100).InInthese
page 7/98). thesecases,
cases, optional line
optional contactors
line contactorscan
can
be dispensed
dispensed with.
with.
• 24 V AC/DC 0
• 110 ... 230 V AC/DC 1
Soft starters for easy starting conditions and high switching frequency,
rated operational voltage Ue 200 ... 400 V,
rated control supply voltage Us 24 ... 230 V AC/DC
3 0.55 1.1 -- A 0.5 0.5 -- -- 22.5 mm
• With screw terminals } 3RW3003-1CB54 1 1 unit
• With spring-loaded terminals } 3RW3003-2CB54 1 1 unit
1)
Soft starter Ue 200 to 480 V with screw terminals:
Standard delivery time SD = 1 day (d).
2) Main connection from size S2: screw terminals.
Note:
the constraints
For the constraintsfor
forthe
themotor
motoroutputs
outputsspecified
specified here, see
here,
pagepage
see 6/8.7/7.
3RV2925-5AB
For soft starters SD Article No. Price PU PS*
Type Size per PU (UNIT,
SET, M)
d
6
Auxiliary terminals
Auxiliary terminals, 3-pole
3RW304. S3 5 3RT2946-4F 1 1 unit
3RT2946-4F
Covers for soft starters
Terminal covers for box terminals
Additional touch protection to be fitted at the box terminals (two units
required per device)
3RW303. S2 } 3RT2936-4EA2 1 1 unit
3RW304. S3 } 3RT2946-4EA2 1 1 unit
3RT2946-4EA2
Terminal covers for cable lugs and busbar connections
For complying with the voltage clearances and as touch protection if
box terminal is removed
(two units required per device)
7
3RW304. S3 5 3RT1946-4EA1 1 1 unit
SOFT STARTERS
3RT1946-4EA1
For motor For soft Version SD Article No. Price PU PS*
starter starters per PU (UNIT,
protectors SET, M)
Si z e Size d
Mounting rails for mounting contactors for the customer assembly of 3RA21 load
feeders with busbar adapters for 60 mm systems
For the discrete configuration of direct-
on-line starters, an additional mounting
rail is needed for the contactor in addition
to the existing mounting rail on the bus-
bar adapter for the motor starter protec-
tor.
-- S0 For pushing onto the device adapter, in- 2 8US1998-7CB45 1 10 units
cluding fixing screws
8US1998-7CB45
Standard mounting rail adapters
For mechanical fixing of motor starter
protector and soft starter;
for snapping onto standard mounting rail
or for screw fixing
S2 S2 Single-unit packaging 2 3RA2932-1CA00 1 1 unit
3RA2932-1CA00
For soft starters Motor starter protectors SD Article No. Price PU PS*
Type Size Size per PU (UNIT,
SET, M)
d
Link modules to motor starter protectors1)
Screw terminals
3RA2921-2GA00
1)
Can be used in size S0 up to 32 A.
Can be used in size S2 up to 65 A in combination with 3RA2932-1CA00
6
3RP1903
per PU (UNIT,
SET, M)
d
SOFT STARTERS
3RT2900-1SB20
1) PC labeling systems for individual inscription of unit labeling plates are
available from: murrplastik Systemtechnik GmbH (see page 16/15).
7
3RW553 (2x)
3RW554 (1x) -- } 3RW5984-0FF00 1 1 unit
SOFT STARTERS
3RW555 (3x) -- } 3RW5985-0FF00 1 1 unit
3RW5983-0FF00
Terminals and terminal covers
Box terminal 3RW552 (2x) -- } 3RW5982-0TB00 1 1 unit
block
3RW5982-0TB00
Screw terminals
Spring-loaded terminals
3RW5955-0TC20
3RW5950-0GD20
3RW55..-.HF.. Yellow NEW NEU
} 3RW5950-0GD30 1 1 unit
6
3RW5950-0GD30
Hinged cover 3RW55 With cutout for } 3RW5950-0GL30 1 1 unit
High Feature
HMI module
3RW5950-0GL30
7
SOFT STARTERS
3RW5980-0HF00
Interface cover 3RW55 -- } 3RW5980-0HL00 1 1 unit
3RW5980-0HL00
6
Connection cable for installing the HMI module in the soft starter
Connection cable -- 0.1 m, flat } 3UF7931-0AA00-0 1 1 unit
3UF7931-0AA00-0
Transport packaging
Transport 3RW551 -- } 3RW5951-0VY00 1 1 unit
packaging 3RW552, 3RW553 -- } 3RW5953-0VY00 1 1 unit
3RW554 -- } 3RW5954-0VY00 1 1 unit
3RW555 -- } 3RW5955-0VY00 1 1 unit
7
SOFT STARTERS
3RW5953-0VY00
Product Manufacturer's Article No. Type of product SD Article No. Price PU PS*
designation of the soft starter per PU (UNIT,
SET, M)
d
Fans
Fans 3RW5216/17 (1x), -- } 3RW5983-0FF00 1 1 unit
3RW5226/27 (2x),
3RW523 (2x)
3RW524 (1x) -- } 3RW5984-0FF00 1 1 unit
3RW5983-0FF00
Terminals
Box terminal block 3RW522 (2x) -- } 3RW5982-0TB00 1 1 unit
3RW5982-0TB00
Screw terminals
Spring-loaded terminals
3RW5953-0GB00
Cover for control 3RW52 Titanium gray } 3RW5950-0GD20 1 1 unit
SOFT STARTERS
cable duct
3RW5950-0GD20
Product Manufacturer's Article No. Type of product SD Article No. Price PU PS*
designation of the soft starter per PU (UNIT,
SET, M)
d
Enclosure components
Hinged cover 3RW52 Without cutout } 3RW5950-0GL20 1 1 unit
3RW5950-0GL20
Transport packaging
Transport 3RW521 -- } 3RW5951-0VY00 1 1 unit
packaging 3RW522, 3RW523 -- } 3RW5953-0VY00 1 1 unit
3RW524 -- } 3RW5954-0VY00 1 1 unit
6
3RW5953-0VY00
7
SOFT STARTERS
Product Manufacturer's Article No. Type of product SD Article No. Price PU PS*
designation of the soft starter per PU (UNIT,
SET, M)
d
Fan
Fan 3RW505 (1x) -- } 3RW5905-0FF00 1 1 unit
3RW507 (1x) -- } 3RW5907-0FF00 1 1 unit
3RW5905-0FF00
Terminals
Screw terminals
6
3RW5980-1TR00
Enclosure components
Hinged cover 3RW50 -- } 3RW5900-0GL00 1 1 unit
3RW5900-0GL00
Transport packaging
Transport 3RW505 -- } 3RW5905-0VY00 1 1 unit
packaging 3RW507 -- } 3RW5907-0VY00 1 1 unit
7
SOFT STARTERS
3RW5905-0VY00
Overview Application
The family of 3RW40 and 3RW44 softstarters are available in The Class 73/74 product is a fully enclosed solid state reduced
stand alone enclosed control designs for smooth starting and voltage starter designed for a wide variety of industrial applica-
stopping of standard NEMA design B three phase inductive mo- tions. The enclosed softstarter offerings are ideal for new as well
tors, thus eliminating physical stresses to the system and load as existing applications where total motor controls is required.
while minimizing starting current. These pre-engineered en-
closed designs offer convenience and flexibility in and UL/CSA Proper selection based on application data is made simple fol-
certified offering. Enclosed styles are available in combination lowing these easy steps:
and non-combination configurations through 600HP and system - Select proper RVSS by application
voltages of 200V, 230V, 480V, and 600V. • Select the 3RW40 versus the 3RW44 using the application
The Class 73 offers either the 3RW40 or 3RW44 in a non-combi- info provided in the open section of the catalog
nation style offering. These non-combination styles come stan- - Select the rating chart for normal starting or sever duty starting
dard with a choice of Type 1, 3R, 12, 4 NEMA rated enclosure, a
control transformer, Sirius softstarter with built-in overload and • Normal starting is rated at 350% of rated motor current
bypass, line side power terminal block, and a reset pushbutton. IM for 10 seconds and based on starts per hour – repre-
The enclosed offering can be powerfully matched with a wide sentative of a class 20 application.
variety of factory modified options such as pushbutton control, • Severe starting is rated at 350% of rated motor current
pilot lights, metering and other control options such as isolation Im for 20 seconds and based on starts per hour – repre-
contactors and emergency start bypass starters. 3RW44 en- sentative of a Class 20 application
closed styles are also available with optional through the door
keypad and Profibus communication. - Select model using Motor nameplate data
• Identify correct motor voltage column
The Class 74 offering includes all of the features of the Class 73
in a combination style design. Standard options are either a cir- • Select rate current or HP row
cuit breaker or fusible disconnect providing short circuit protec- • Find ordering number under desired enclosure type
tion and soft starting in one package. column (e.g. NEMA 1)
• Select appropriate system voltage
- Select factory modification on page 6/401)
Example:
3RW44, N12, CB disconnect, 460V, 200HP with a start/stop and
red run light
Order No.
74MT34BFAP A1 FC
Product Nomenclature
Class 73 and 74 Enclosed Soft Starters
7
SOFT STARTERS
Class
73 = Non-combination type
74 = Combination type
1)
Some modifications will require a larger ‘Modified’ box than the standard box
e.g. Isolation contactor, space heater, etc. See page 7/124 for instructions.
Product Category IEC Smart Infrastructure, Industrial Control Catalog 2021 7/111
Soft Starters
Ordering Information
� Enclosed devices should be ordered by Ideal applications for 3RW40 enclosed
the FLA of the motor. softstarters
b Fans
� The 3RW40 is designed for normal b Pumps
starting applications. b Easy starting loads starting in less than
� or factory modifications see page 7/124.
F 10 seconds
� or dimensional drawings see page 7/125.
F
Class 73 starters are built to UL and CSA
standards
Class 73 non-combination starters include:
3RW40 Enclosed features: b NEMA rated enclosure
b Available in NEMA 1,12,3R,4, and b 3RW40 Sirius softstarter with built-in OL
4 stainless steel and bypass
b Compact size b Control Circuit Transformer
b Built-in Bypass contactor b Line side power terminal block
b Voltage ramp up and ramp down b Reset button
b Current limit adjustment of 125 - 550% b Isolation Contactor
b Internal overload class 10,15,or 20
b Internal self protection
b Fault monitoring
b Isolation Contactor
Rated MAX HP
a KW Class 10 Light Duty (350% * Ie for 10s)b
Operating OPEN Style List List List List NEMA 4/4X List
Current 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ NEMA 3R Price $ NEMA 12 Price $ NEMA 4 Price $ Stainless Steel Price $
11 3 3 7.5 — 6 3RW4024-1BB14 73AR3_BFA 73AR3_DFA 73AR3_0FA 73AR3_EFA 73AR3_WFA
23 5 7.5 15 — 13 3RW4026-1BB14 73BR3_BFA 73BR3_DFA 73BR3_0FA 73BR3_EFA 73BR3_WFA
29 7.5 10 20 — 16 3RW4027-1BB14 73CR3_BFA 73CR3_DFA 73CR3_0FA 73CR3_EFA 73CR3_WFA
34 10 10 25 — 18 3RW4028-1BB14 73DR3_BFA 73DR3_DFA 73DR3_0FA 73DR3_EFA 73DR3_WFA
42 10 15 30 — 23 3RW4036-1BB14 73ER3_BFA 73ER3_DFA 73ER3_0FA 73ER3_EFA 73ER3_WFA
58 15 20 40 — 31 3RW4037-1BB14 73FR3_BFA 73FR3_DFA 73FR3_0FA 73FR3_EFA 73FR3_WFA
62 20 20 40 — 33 3RW4038-1BB14 73GR3_BFA 73GR3_DFA 73GR3_0FA 73GR3_EFA 73GR3_WFA
73 20 25 50 — 39 3RW4046-1BB14 73HR3_BFA 73HR3_DFA 73HR3_0FA 73HR3_EFA 73HR3_WFA
98 30 30 75 — 52 3RW4047-1BB14 73JR3_BFA 73JR3_DFA 73JR3_0FA 73JR3_EFA 73JR3_WFA
200V 6 6 6 6 6
7
230V 2 2 2 2 2
380V 3 3 3 3 3
SOFT STARTERS
460V 4 4 4 4 4
a Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor. Starter selection is dependent on type of application. Ie = FLA rating of motor
HPs are for reference only. Enclosed ratings are at 40°C
7/112 Smart Infrastructure, Industrial Control Catalog 2021 Product Category IEC
Soft Starters
Ordering Information
Ideal applications for 3RW40 enclosed
� nclosed devices should be ordered by
E
softstarters:
the FLA of the motor.
b Fans
� he 3RW40 is designed for normal
T b Pumps
starting applications (Class 10 b Building/construction machines
applications). b Presses
� For factory modifications see page 7/124. b Escalators
b Transport systems
� For dimensional drawings see page 7/125. b Air conditioning systems
Class 73 non-combination starters include: b Ventilators
b NEMA rated enclosure b Assembly lines
3RW40 Enclosed features: Class 73 starters are built to UL and
b Available in NEMA 1, 12, 3R, 4, and 4 b 3RW40 Sirius softstarter with built-in OL
stainless steel and bypass CSA standards.
b Compact size b Control circuit transformer
b Built-in bypass contactor
b Voltage ramp up and ramp down b Line side power terminal block
b Current limit adjustment of 125 - 550% b Reset button
b Internal overload class 10, 15, or 20
b Internal self protection
b Fault monitoring
For all technical information, please consult the 2006 Industrial Controls Catalog or contact your local sales support center.
7
117 — — 75 100 — 3RW4055-6BB35 73AS35BFA 73AS35DFA 73AS350FA 73AS35EFA 73AS35WFA
145 — — 100 150 — 3RW4056-6BB35 73BS35BFA 73BS35DFA 73BS350FA 73BS35EFA 73BS35WFA
205 — — 150 200 — 3RW4073-6BB35 73CS35BFA 73CS35DFA 73CS350FA 73CS35EFA 73CS35WFA
SOFT STARTERS
248 — — 200 250 — 3RW4074-6BB35 73DS35BFA 73DS35DFA 73DS350FA 73DS35EFA 73DS35WFA
315 — — 250 300 — 3RW4075-6BB35 73ES35BFA 73ES35DFA 73ES350FA 73ES35EFA 73ES35WFA
385 — — 300 400 — 3RW4076-6BB35 73FS35BFA 73FS35DFA 73FS350FA 73FS35EFA 73FS35WFA
a Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor.
HPs are for reference only. Enclosed ratings are at 40°C.
b Starter selection is dependent on type of application. Im = FLA rating of motor.
Product Category IEC Smart Infrastructure, Industrial Control Catalog 2021 7/113
Soft Starters
Ordering Information
� Enclosed devices should be ordered by Ideal applications for 3RW40 enclosed
the FLA of the motor. softstarters
b Fans
� The 3RW40 is designed for normal b Pumps
starting applications. b Easy starting loads starting in less than
� or factory modifications see page 7/124.
F 10 seconds
� or dimensional drawings see page 7/125.
F
Class 74 starters are built to UL and CSA
standards
Class 74 non-combination starters include:
3RW40 Enclosed features: b NEMA rated enclosure
b Available in NEMA 1, 12, 3R, 4, and b Circuit Breaker disconnect with shunt trip
4 stainless steel b 3RW40 Sirius softstarter with built-in OL
b Compact size and bypass
b Built-in Bypass contactor b Control Circuit Transformer
b Voltage ramp up and ramp down b Isolation Contactor
b Current limit adjustment of 125 - 550%
b Internal overload class 10, 15, or 20
b Internal self protection
b Fault monitoring
b Isolation Contactor
Rated MAX HP
a KW Class 10 Light Duty (350% * Ie for 10s)b
Operating OPEN Style List List List List NEMA 4/4X List
Current 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ NEMA 3R Price $ NEMA 12 Price $ NEMA 4 Price $ Stainless Steel Price $
11 3 3 7.5 — 6 3RW4024-1BB14 74AR3_BFAP 74AR3_DFAP 74AR3_0FAP 74AR3_EFAP 74AR3_WFAP
23 5 7.5 15 — 13 3RW4026-1BB14 74BR3_BFAP 74BR3_DFAP 74BR3_0FAP 74BR3_EFAP 74BR3_WFAP
29 7.5 10 20 — 16 3RW4027-1BB14 74CR3_BFAP 74CR3_DFAP 74CR3_0FAP 74CR3_EFAP 74CR3_WFAP
34 10 10 25 — 18 3RW4028-1BB14 74DR3_BFAP 74DR3_DFAP 74DR3_0FAP 74DR3_EFAP 74DR3_WFAP
42 10 15 30 — 23 3RW4036-1BB14 74ER3_BFAP 74ER3_DFAP 74ER3_0FAP 74ER3_EFAP 74ER3_WFAP
58 15 20 40 — 31 3RW4037-1BB14 74FR3_BFAP 74FR3_DFAP 74FR3_0FAP 74FR3_EFAP 74FR3_WFAP
62 20 20 40 — 33 3RW4038-1BB14 74GR3_BFAP 74GR3_DFAP 74GR3_0FAP 74GR3_EFAP 74GR3_WFAP
73 20 25 50 — 39 3RW4046-1BB14 74HR3_BFAP 74HR3_DFAP 74HR3_0FAP 74HR3_EFAP 74HR3_WFAP
98 30 30 75 — 52 3RW4047-1BB14 74JR3_BFAP 74JR3_DFAP 74JR3_0FAP 74JR3_EFAP 74JR3_WFAP
7
200V 6 6 6 6 6
230V 2 2 2 2 2
380V 3 3 3 3 3
SOFT STARTERS
460V 4 4 4 4 4
a Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor. Starter selection is dependent on type of application. Ie = FLA rating of motor
HPs are for reference only. Enclosed ratings are at 40°C
7/114 Smart Infrastructure, Industrial Control Catalog 2021 Product Category IEC
Soft Starters
Enclosed 3RW44
Ordering Information
�
Enclosed devices should be ordered by Ideal applications for 3RW40 enclosed
the FLA of the motor. softstarters:
b Fans
� he 3RW40 is designed for normal
T b Pumps
starting applications (Class 10 b Building/construction machines
applications). b Presses
� or factory modifications see page 7/124.
F b Escalators
b Transport systems
� or dimensional drawings see page 7/125.
F b Air conditioning systems
Class 74 non-combination starters include: b Ventilators
b Assembly lines
3RW40 Enclosed features: b NEMA rated enclosure
Class 74 starters are built to UL and CSA
b Available in NEMA 1, 12, 3R, 4, and 4 b Circuit breaker disconnect with shunt trip
stainless steel standards.
b 3RW40 Sirius softstarter with built-in OL
b Compact size and bypass
b Built-in bypass contactor
b Voltage ramp up and ramp down b Control circuit transformer
b Current limit adjustment of 125 - 550%
b Internal overload class 10, 15, or 20
b Internal self protection
b Fault monitoring
For all technical information, please consult the 2006 Industrial Controls Catalog or contact your local sales support center.
Rated MAX HP
a KW Class 10 Light Duty (350% * Im for 10s)b
Operating OPEN Style List List List List NEMA 4/4X List
Current 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ NEMA 3R Price $ NEMA 12 Price $ NEMA 4 Price $ Stainless Steel Price $
117 30 40 75 — 56 3RW4055-6BB34 74AS3_BFAP 74AS3_DFAP 74AS3_0FAP 74AS3_EFAP 74AS3_WFAP
145 40 50 100 — 75 3RW4056-6BB34 74BS3_BFAP 74BS3_DFAP 74BS3_0FAP 74BS3_EFAP 74BS3_WFAP
205 60 75 150 — 112 3RW4073-6BB34 74CS3_BFAP 74CS3_DFAP 74CS3_0FAP 74CS3_EFAP
248 75 100 200 — 149 3RW4074-6BB34 74DS3_BFAP 74DS3_DFAP 74DS3_0FAP 74DS3_EFAP
315 100 125 250 — 186 3RW4075-6BB34 74ES3_BFAP 74ES3_DFAP 74ES3_0FAP 74ES3_EFAP
385 125 150 300 — 224 3RW4076-6BB34 74FS3_BFAP 74FS3_DFAP 74FS3_0FAP 74FS3_EFAP
200V 6 6 6 6 6
230V 2 2 2 2 2
380V 3 3 3 3 3
460V 4 4 4 4 4
7
117 — — 75 100 — 3RW4055-6BB35 74AS35BFAP 74AS35DFAP 74AS350FAP 74AS35EFAP 74AS35WFAP
145 — — 100 150 — 3RW4056-6BB35 74BS35BFAP 74BS35DFAP 74BS350FAP 74BS35EFAP 74BS35WFAP
SOFT STARTERS
205 — — 150 200 — 3RW4073-6BB35 74CS35BFAP 74CS35DFAP 74CS350FAP 74CS35EFAP
248 — — 200 250 — 3RW4074-6BB35 74DS35BFAP 74DS35DFAP 74DS350FAP 74DS35EFAP
315 — — 250 300 — 3RW4075-6BB35 74ES35BFAP 74ES35DFAP 74ES350FAP 74ES35EFAP
385 — — 300 400 — 3RW4076-6BB35 74FS35BFAP 74FS35DFAP 74FS350FAP 74FS35EFAP
a Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor. b Starter selection is dependent on type of application. Im = FLA rating of motor.
HPs are for reference only. Enclosed ratings are at 40°C.
Product Category IEC Smart Infrastructure, Industrial Control Catalog 2021 7/115
Soft Starters
Ordering Information
� Enclosed devices should be ordered by Ideal applications for 3RW40 enclosed
the FLA of the motor. softstarters
b Fans
� The 3RW40 is designed for normal b Pumps
starting applications. b Easy starting loads starting in less than
� or factory modifications see page 7/124.
F 10 seconds
� or dimensional drawings see page 7/125.
F
Class 74 starters are built to UL and CSA
standards
Class 73 non-combination starters include:
b NEMA rated enclosure
3RW40 Enclosed features: b Fusible Disconnect
b Available in NEMA 1, 12, 3R, 4, and b 3RW40 Sirius softstarter with built-in
4 stainless steel
b Compact size OL and bypass
b Built-in Bypass contactor b Control Circuit Transformer
b Voltage ramp up and ramp down b Isolation Contactor
b Current limit adjustment of 125 - 550%
b Internal overload class 10,15,or 20
b Internal self protection
b Fault monitoring
b Isolation Contactor
Rated MAX HP
a KW Class 10 Light Duty (350% * Ie for 10s)b
Operating OPEN Style List List List List NEMA 4/4X List
Current 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ NEMA 3R Price $ NEMA 12 Price $ NEMA 4 Price $ Stainless Steel Price $
11 3 3 7.5 — 6 3RW4024-1BB14 74AR3_BFAF 74AR3_DFAF 74AR3_0FAF 74AR3_EFAF 74AR3_WFAF
23 5 7.5 15 — 13 3RW4026-1BB14 74BR3_BFAF 74BR3_DFAF 74BR3_0FAF 74BR3_EFAF 74BR3_WFAF
29 7.5 10 20 — 16 3RW4027-1BB14 74CR3_BFAF 74CR3_DFAF 74CR3_0FAF 74CR3_EFAF 74CR3_WFAF
34 10 10 25 — 18 3RW4028-1BB14 74DR3_BFAF 74DR3_DFAF 74DR3_0FAF 74DR3_EFAF 74DR3_WFAF
42 10 15 30 — 23 3RW4036-1BB14 74ER3_BFAF 74ER3_DFAF 74ER3_0FAF 74ER3_EFAF 74ER3_WFAF
58 15 20 40 — 31 3RW4037-1BB14 74FR3_BFAF 74FR3_DFAF 74FR3_0FAF 74FR3_EFAF 74FR3_WFAF
62 20 20 40 — 33 3RW4038-1BB14 74GR3_BFAF 74GR3_DFAF 74GR3_0FAF 74GR3_EFAF 74GR3_WFAF
73 20 25 50 — 39 3RW4046-1BB14 74HR3_BFAF 74HR3_DFAF 74HR3_0FAF 74HR3_EFAF 74HR3_WFAF
98 30 30 75 — 52 3RW4047-1BB14 74JR3_BFAF 74JR3_DFAF 74JR3_0FAF 74JR3_EFAF 74JR3_WFAF
200V 6 6 6 6 6
7
230V 2 2 2 2 2
380V 3 3 3 3 3
SOFT STARTERS
460V 4 4 4 4 4
a Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor. Starter selection is dependent on type of application. Ie = FLA rating of motor
HPs are for reference only. Enclosed ratings are at 40°C
7/116 Smart Infrastructure, Industrial Control Catalog 2021 Product Category IEC
Soft Starters
Enclosed 3RW44
Ordering Information
� nclosed devices should be ordered by
E Ideal applications for 3RW40 enclosed
the FLA of the motor. softstarters:
b Fans
� he 3RW40 is designed for normal
T b Pumps
starting applications (Class 10 b Building/construction machines
applications). b Presses
� or factory modifications see page 7/124.
F b Escalators
b Transport systems
� or dimensional drawings see page 7/125.
F b Air conditioning systems
Class 74 combination starters include: b Ventilators
b Assembly lines
3RW40 Enclosed features: b NEMA rated enclosure
b Available in NEMA 1, 12, 3R, 4, and 4 Class 74 starters are built to UL and CSA
b Fusible disconnect
stainless steel standards.
b Compact size b 3RW40 Sirius softstarter with built-in OL
and bypass
b Built-in bypass contactor
b Voltage ramp up and ramp down b Control circuit transformer
b Current limit adjustment of 125 - 550%
b Internal overload class 10, 15, or 20
b Internal self protection
b Fault monitoring
For all technical information, please consult the 2006 Industrial Controls Catalog or contact your local sales support center.
Rated MAX HP
a KW Class 10 Light Duty (350% * Im for 10s)b
Operating OPEN Style List List List List NEMA 4/4X List
Current 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ NEMA 3R Price $ NEMA 12 Price $ NEMA 4 Price $ Stainless Steel Price $
117 30 40 75 — 56 3RW4055-6BB34 74AS3_BFAF 74AS3_DFAF 74AS3_0FAF 74AS3_EFAF 74AS3_WFAF
145 40 50 100 — 75 3RW4056-6BB34 74BS3_BFAF 74BS3_DFAF 74BS3_0FAF 74BS3_EFAF 74BS3_WFAF
205 60 75 150 — 112 3RW4073-6BB34 74CS3_BFAF 74CS3_DFAF 74CS3_0FAF 74CS3_EFAF
248 75 100 200 — 149 3RW4074-6BB34 74DS3_BFAF 74DS3_DFAF 74DS3_0FAF 74DS3_EFAF
315 100 125 250 — 186 3RW4075-6BB34 74ES3_BFAF 74ES3_DFAF 74ES3_0FAF 74ES3_EFAF
385 125 150 300 — 224 3RW4076-6BB34 74FS3_BFAF 74FS3_DFAF 74FS3_0FAF 74FS3_EFAF
200V 6 6 6 6 6
230V 2 2 2 2 2
380V 3 3 3 3 3
460V 4 4 4 4 4
7
117 — — 75 100 — 3RW4055-6BB35 74AS35BFAF 74AS35DFAF 74AS350FAF 74AS35EFAF 74AS35WFAF
145 — — 100 150 — 3RW4056-6BB35 74BS35BFAF 74BS35DFAF 74BS350FAF 74BS35EFAF 74BS35WFAF
SOFT STARTERS
205 — — 150 200 — 3RW4073-6BB35 74CS35BFAF 74CS35DFAF 74CS350FAF 74CS35EFAF
248 — — 200 250 — 3RW4074-6BB35 74DS35BFAF 74DS35DFAF 74DS350FAF 74DS35EFAF
315 — — 250 300 — 3RW4075-6BB35 74ES35BFAF 74ES35DFAF 74ES350FAF 74ES35EFAF
385 — — 300 400 — 3RW4076-6BB35 74FS35BFAF 74FS35DFAF 74FS350FAF 74FS35EFAF
a Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor. b Starter selection is dependent on type of application. Im = FLA rating of motor.
HPs are for reference only. Enclosed ratings are at 40°C.
Product Category IEC Smart Infrastructure, Industrial Control Catalog 2021 7/117
Soft Starters
Enclosed 3RW44
Ordering Information
� nclosed devices should be ordered by
E Ideal applications for 3RW44 enclosed
the FLA of the motor. softstarters:
b Fans
� he 3RW44 is designed for normal
T b Pumps
starting applications. b Conveying systems and lifts
3RW44 Enclosed features:
b Available in NEMA 1, 12, 3R, 4, and 4
� or factory modifications see page 7/124.
F b Hydraulics
stainless steel b Machine tools
� or dimensional drawings see page 7/125.
F b Mills saws
b Compact size
b Built-in bypass contactor Class 73 non-combination starters include: b Crushers and grinders
b Multiple starting/stopping techniques b Mixers
including torque control b NEMA rated enclosure
b HVAC systems
b Internal overload class 5, 10, 15, 20, or 30 b 3RW44 Sirius softstarter with built-in OL
The 3RW44 severe duty rating table should
b Built-in graphical LCD keypad and bypass
b Internal self protection be applied for high inertia applications
b Control circuit transformer
such rock crushers, chippers, screw
b Fault monitoring
b 3 parameter sets b Reset button compressors, ect.
b Communication capable via opt. Profibus Class 73 starters are built to UL and CSA
module
b Programmable inputs and outputs standards.
b External keypad available
Rated MAX HP
a KW Class 10 Light Duty (350% * Im for 10s)b
Operating OPEN Style List List List List NEMA 4/4X List
Current 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ NEMA 3R Price $ NEMA 12 Price $ NEMA 4 Price $ Stainless Steel Price $
26 7.5 7.5 15 — 12 3RW4422-1BC34 73AT3_BFA 73AT3_DFA 73AT3_0FA 73AT3_EFA 73AT3_WFA
32 10 10 20 — 15 3RW4423-1BC34 73BT3_BFA 73BT3_DFA 73BT3_0FA 73BT3_EFA 73BT3_WFA
42 10 15 25 — 19 3RW4424-1BC34 73CT3_BFA 73CT3_DFA 73CT3_0FA 73CT3_EFA 73CT3_WFA
51 15 15 30 — 22 3RW4425-1BC34 73DT3_BFA 73DT3_DFA 73DT3_0FA 73DT3_EFA 73DT3_WFA
68 20 25 50 — 37 3RW4426-1BC34 73ET3_BFA 73ET3_DFA 73ET3_0FA 73ET3_EFA 73ET3_WFA
82 25 30 60 — 45 3RW4427-1BC34 73FT3_BFA 73FT3_DFA 73FT3_0FA 73FT3_EFA 73FT3_WFA
100 30 30 75 — 56 3RW4434-6BC34 73GT3_BFA 73GT3_DFA 73GT3_0FA 73GT3_EFA 73GT3_WFA
117 30 40 75 — 56 3RW4435-6BC34 73HT3_BFA 73HT3_DFA 73HT3_0FA 73HT3_EFA 73HT3_WFA
145 40 50 100 — 75 3RW4436-6BC34 73JT3_BFA 73JT3_DFA 73JT3_0FA 73JT3_EFA 73JT3_WFA
180 60 60 125 — 93 3RW4443-6BC34 73KT3_BFA 73KT3_DFA 73KT3_0FA 73KT3_EFA 73KT3_WFA
215 60 75 150 — 112 3RW4444-6BC34 73LT3_BFA 73LT3_DFA 73LT3_0FA 73LT3_EFA 73LT3_WFA
280 75 100 200 — 149 3RW4445-6BC34 73MT3_BFA 73MT3_DFA 73MT3_0FA 73MT3_EFA 73MT3_WFA
315 100 125 250 — 186 3RW4446-6BC34 73NT3_BFA 73NT3_DFA 73NT3_0FA 73NT3_EFA 73NT3_WFA
385 125 150 300 — 224 3RW4447-6BC34 73PT3_BFA 73PT3_DFA 73PT3_0FA 73PT3_EFA 73PT3_WFA
494 150 200 400 — 298 3RW4453-6BC34 73QT3_BFA 73QT3_DFA 73QT3_0FA 73QT3_EFA
7
551 150 200 450 — 336 3RW4454-6BC34 73RT3_BFA 73RT3_DFA 73RT3_0FA 73RT3_EFA
615 200 250 500 — 373 3RW4455-6BC34 73ST3_BFA 73ST3_DFA 73ST3_0FA 73ST3_EFA
693 200 250 550 — 410
SOFT STARTERS
7/118 Smart Infrastructure, Industrial Control Catalog 2021 Product Category IEC
Soft Starters
Enclosed 3RW44
Ordering Information
� nclosed devices should be ordered by
E Ideal applications for 3RW44 enclosed
the FLA of the motor. softstarters:
b Fans
� he 3RW44 is designed for normal
T
b Pumps
starting applications.
3RW44 Enclosed features: b Conveying systems and lifts
b Available in NEMA 1, 12, 3R, 4, and 4
� or factory modifications see page 7/124.
F b Hydraulics
stainless steel � or dimensional drawings see page 7/125.
F b Machine tools
b Compact size b Mills saws
b Built-in bypass contactor Class 73 non-combination starters include: b Crushers and grinders
b Multiple starting/stopping techniques b NEMA rated enclosure b Mixers
including torque control
b Internal overload class 10, 15, or 20 b 3RW44 Sirius softstarter with built-in OL b HVAC systems
and bypass
b Built-in graphical LCD keypad The 3RW44 severe duty rating table should
b Internal self protection b Control circuit transformer be applied for high inertia applications
b Fault monitoring b Line side power terminal block such rock crushers, chippers, screw
b 3 parameter sets b Reset button compressors, ect.
b Communication capable via opt. Profibus
module Class 73 starters are built to UL and CSA
b Programmable inputs and outputs standards.
b External keypad available
Rated MAX HP
a KW Class 20 Severe Duty (350% * Im for 20s)b
Operating OPEN Style List List List List NEMA 4/4X List
Current 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ NEMA 3R Price $ NEMA 12 Price $ NEMA 4 Price $ Stainless Steel Price $
26 7.5 7.5 15 — 12 3RW4422-1BC34 73AT3_BFA 73AT3_DFA 73AT3_0FA 73AT3_EFA 73AT3_WFA
32 10 10 20 — 15 3RW4423-1BC34 73BT3_BFA 73BT3_DFA 73BT3_0FA 73BT3_EFA 73BT3_WFA
42 10 15 25 — 19 3RW4424-1BC34 73CT3_BFA 73CT3_DFA 73CT3_0FA 73CT3_EFA 73CT3_WFA
51 15 15 30 — 22 3RW4425-1BC34 73DT3_BFA 73DT3_DFA 73DT3_0FA 73DT3_EFA 73DT3_WFA
68 20 25 50 — 37 3RW4426-1BC34 73ET3_BFA 73ET3_DFA 73ET3_0FA 73ET3_EFA 73ET3_WFA
82 25 30 60 — 45 3RW4427-1BC34 73FT3_BFA 73FT3_DFA 73FT3_0FA 73FT3_EFA 73FT3_WFA
97 30 30 60 — 45 3RW4434-6BC34 73GT3_BFA 73GT3_DFA 73GT3_0FA 73GT3_EFA 73GT3_WFA
113 30 40 75 — 56 3RW4435-6BC34 73HT3_BFA 73HT3_DFA 73HT3_0FA 73HT3_EFA 73HT3_WFA
134 40 50 75 — 56 3RW4436-6BC34 73JT3_BFA 73JT3_DFA 73JT3_0FA 73JT3_EFA 73JT3_WFA
175 50 60 100 — 75 3RW4443-6BC34 73KT3_BFA 73KT3_DFA 73KT3_0FA 73KT3_EFA 73KT3_WFA
195 60 75 125 — 93 3RW4444-6BC34 73LT3_BFA 73LT3_DFA 73LT3_0FA 73LT3_EFA 73LT3_WFA
243 75 75 150 — 112 3RW4445-6BC34 73MT3_BFA 73MT3_DFA 73MT3_0FA 73MT3_EFA 73MT3_WFA
263 75 100 200 — 149 3RW4446-6BC34 73NT3_BFA 73NT3_DFA 73NT3_0FA 73NT3_EFA 73NT3_WFA
326 100 125 250 — 186 3RW4447-6BC34 73PT3_BFA 73PT3_DFA 73PT3_0FA 73PT3_EFA 73PT3_WFA
494 150 150 400 — 224 3RW4453-6BC34 73QT3_BFA 73QT3_DFA 73QT3_0FA 73QT3_EFA
7
551 150 200 450 — 298 3RW4454-6BC34 73RT3_BFA 73RT3_DFA 73RT3_0FA 73RT3_EFA
615 200 200 500 — 336 3RW4455-6BC34 73ST3_BFA 73ST3_DFA 73ST3_0FA 73ST3_EFA
634 200 250 500 — 373 3RW4456-6BC34 73TT3_BFA 73TT3_DFA 73TT3_0FA 73TT3_EFA
SOFT STARTERS
650 200 250 550 — 410 3RW4457-6BC34 73WT3_BFA 73WT3_DFA 73WT3_0FA 73WT3_EFA
880 300 350 700 — 522 3RW4465-6BC34 73YT3_BFA 73YT3_0FA
940 300 350 750 — 559 3RW4466-6BC34 73ZT3_BFA 73ZT3_0FA
200V 6 6 6 6 6
230V 2 2 2 2 2
380V 3 3 3 3 3
460V 4 4 4 4 4
26 — — 15 20 — 3RW4422-1BC35 73AT35BFA 73AT35DFA 73AT350FA 73AT35EFA 73AT35WFA
32 — — 20 25 — 3RW4423-1BC35 73BT35BFA 73BT35DFA 73BT350FA 73BT35EFA 73BT35WFA
42 — — 25 30 — 3RW4424-1BC35 73CT35BFA 73CT35DFA 73CT350FA 73CT35EFA 73CT35WFA
51 — — 30 40 — 3RW4425-1BC35 73DT35BFA 73DT35DFA 73DT350FA 73DT35EFA 73DT35WFA
68 — — 50 50 — 3RW4426-1BC35 73ET35BFA 73ET35DFA 73ET350FA 73ET35EFA 73ET35WFA
82 — — 60 75 — 3RW4427-1BC35 73FT35BFA 73FT35DFA 73FT350FA 73FT35EFA 73FT35WFA
97 — — 60 75 — 3RW4434-6BC35 73GT35BFA 73GT35DFA 73GT350FA 73GT35EFA 73GT35WFA
113 — — 75 100 — 3RW4435-6BC35 73HT35BFA 73HT35DFA 73HT350FA 73HT35EFA 73HT35WFA
134 — — 75 125 — 3RW4436-6BC35 73JT35BFA 73JT35DFA 73JT350FA 73JT35EFA 73JT35WFA
175 — — 100 150 — 3RW4443-6BC35 73KT35BFA 73KT35DFA 73KT350FA 73KT35EFA 73KT35WFA
195 — — 125 200 — 3RW4444-6BC35 73LT35BFA 73LT35DFA 73LT350FA 73LT35EFA 73LT35WFA
243 — — 150 200 — 3RW4445-6BC35 73MT35BFA 73MT35DFA 73MT350FA 73MT35EFA 73MT35WFA
263 — — 200 250 — 3RW4446-6BC35 73NT35BFA 73NT35DFA 73NT350FA 73NT35EFA 73NT35WFA
326 — — 250 300 — 3RW4447-6BC35 73PT35BFA 73PT35DFA 73PT350FA 73PT35EFA 73PT35WFA
494 — — 400 500 — 3RW4453-6BC35 73QT35BFA 73QT35DFA 73QT350FA 73QT35EFA
551 — — 450 550 — 3RW4454-6BC35 73RT35BFA 73RT35DFA 73RT350FA 73RT35EFA
615 — — 500 600 — 3RW4455-6BC35 73ST35BFA 73ST35DFA 73ST350FA 73ST35EFA
693 — — 500 650 — 3RW4456-6BC35 73TT35BFA 73TT35DFA 73TT350FA 73TT35EFA
780 — — 550 700 — 3RW4457-6BC35 73WT35BFA 73WT35DFA 73WT350FA 73WT35EFA
880 — — 700 850 — 3RW4465-6BC35 73YT35BFA 73YT350FA
940 — — 750 900 — 3RW4466-6BC35 73ZT35BFA 73ZT350FA
a Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor. b Starter selection is dependent on type of application. Im = FLA rating of motor.
HPs are for reference only. Enclosed ratings are at 40°C.
Product Category IEC Smart Infrastructure, Industrial Control Catalog 2021 7/119
Soft Starters
Enclosed 3RW44
Ordering Information
� nclosed devices should be ordered by
E Ideal applications for 3RW44 enclosed
the FLA of the motor. softstarters:
b Fans
� T he 3RW44 is designed for normal
starting applications. b Pumps
b Conveying systems and lifts
3RW44 Enclosed features: � F or factory modifications see page 7/124. b Hydraulics
b Available in NEMA 1, 12, 3R, 4, and 4 � F or dimensional drawings see page 7/125. b Machine tools
stainless steel
b Compact size � F or stocked versions see page 7/89. b Mills saws
b Built-in bypass contactor Class 74 non-combination starters include: b Crushers and grinders
b Multiple starting/stopping techniques b NEMA rated enclosure
b Mixers
including torque control b HVAC systems
b Internal overload class 5, 10, 15, 20, or 30 b 3RW44 Sirius softstarter with built-in OL
b Built-in graphical LCD keypad and bypass The 3RW44 severe duty rating table should
b Internal self protection b Circuit breaker with disconnect be applied for high inertia applications
b Fault monitoring b Control circuit transformer such rock crushers, chippers, screw
b 3 parameter sets compressors, ect.
b Communication capable via opt. Profibus b Reset button
module Class 74 starters are built to UL and CSA
b Programmable inputs and outputs standards.
b External keypad available
551 150 200 450 — 336 3RW4454-6BC34 74RT3_BFAT 74RT3_DFAT 74RT3_0FAT 74RT3_EFAT
615 200 250 500 — 373 3RW4455-6BC34 74ST3_BFAT 74ST3_DFAT 74ST3_0FAT 74ST3_EFAT
693 200 250 550 — 410 3RW4456-6BC34 74TT3_BFAT 74TT3_DFAT 74TT3_0FAT 74TT3_EFAT
SOFT STARTERS
780 200 250 600 — 447 3RW4457-6BC34 74WT3_BFAT 74WT3_DFAT 74WT3_0FAT 74WT3_EFAT
970 350 350 800 — 597 3RW4465-6BC34 74YT3_BFAT 74YT3_0FAT
1076 350 400 900 — 672 3RW4466-6BC34 74ZT3_BFAT 74ZT3_0FAT
200V 6 6 6 6 6
230V 2 2 2 2 2
380V 3 3 3 3 3
460V 4 4 4 4 4
26 — — 15 20 — 3RW4422-1BC35 74AT35BFAP 74AT35DFAP 74AT350FAP 74AT35EFAP 74AT35WFAP
32 — — 20 25 — 3RW4423-1BC35 74BT35BFAP 74BT35DFAP 74BT350FAP 74BT35EFAP 74BT35WFAP
42 — — 25 30 — 3RW4424-1BC35 74CT35BFAP 74CT35DFAP 74CT350FAP 74CT35EFAP 74CT35WFAP
51 — — 30 40 — 3RW4425-1BC35 74DT35BFAP 74DT35DFAP 74DT350FAP 74DT35EFAP 74DT35WFAP
68 — — 50 50 — 3RW4426-1BC35 74ET35BFAP 74ET35DFAP 74ET350FAP 74ET35EFAP 74ET35WFAP
82 — — 60 75 — 3RW4427-1BC35 74FT35BFAP 74FT35DFAP 74FT350FAP 74FT35EFAP 74FT35WFAP
100 — — 75 75 — 3RW4434-6BC35 74GT35BFAP 74GT35DFAP 74GT350FAP 74GT35EFAP 74GT35WFAP
117 — — 75 100 — 3RW4435-6BC35 74HT35BFAP 74HT35DFAP 74HT350FAP 74HT35EFAP 74HT35WFAP
145 — — 100 125 — 3RW4436-6BC35 74JT35BFAP 74JT35DFAP 74JT350FAP 74JT35EFAP 74JT35WFAP
180 — — 125 150 — 3RW4443-6BC35 74KT35BFAP 74KT35DFAP 74KT350FAP 74KT35EFAP
215 — — 150 200 — 3RW4444-6BC35 74LT35BFAP 74LT35DFAP 74LT350FAP 74LT35EFAP
280 — — 200 250 — 3RW4445-6BC35 74MT35BFAP 74MT35DFAP 74MT350FAP 74MT35EFAP
315 — — 250 300 — 3RW4446-6BC35 74NT35BFAP 74NT35DFAP 74NT350FAP 74NT35EFAP
385 — — 300 400 — 3RW4447-6BC35 74PT35BFAP 74PT35DFAP 74PT350FAP 74PT35EFAP
494 — — 400 500 — 3RW4453-6BC35 74QT35BFAT 74QT35DFAT 74QT350FAT 74QT35EFAT
551 — — 450 600 — 3RW4454-6BC35 74RT35BFAT 74RT35DFAT 74RT350FAT 74RT35EFAT
615 — — 500 700 — 3RW4455-6BC35 74ST35BFAT 74ST35DFAT 74ST350FAT 74ST35EFAT
693 — — 550 750 — 3RW4456-6BC35 74TT35BFAT 74TT35DFAT 74TT350FAT 74TT35EFAT
780 — — 600 850 — 3RW4457-6BC35 74WT35BFAT 74WT35DFAT 74WT350FAT 74WT35EFAT
970 — — 800 1000 — 3RW4465-6BC35 74YT35BFAT 74YT350FAT
1076 — — 900 1100 — 3RW4466-6BC35 74ZT35BFAT 74ZT350FAT
a Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor. b Starter selection is dependent on type of application. Im = FLA rating of motor.
HPs are for reference only. Enclosed ratings are at 40°C.
7/120 Smart Infrastructure, Industrial Control Catalog 2021 Product Category IEC
Soft Starters
Enclosed 3RW44
Ordering Information
� nclosed devices should be ordered by
E Ideal applications for 3RW44 enclosed
the FLA of the motor. softstarters:
� he 3RW44 is designed for normal
T b Fans
starting applications. b Pumps
3RW44 Enclosed features: b Conveying systems and lifts
� or factory modifications see page 7/124.
F
b Hydraulics
b Available in NEMA 1, 12, 3R, 4, and 4 or dimensional drawings see page 7/125.
F
stainless steel
�
b Machine tools
b Compact size � or stocked versions see page 7/89.
F b Mills saws
b Built-in bypass contactor Class 74 non-combination starters include: b Crushers and grinders
b Multiple starting/stopping techniques b Mixers
including torque control b NEMA rated enclosure b HVAC systems
b Internal overload class 5, 10, 15, 20, or 30 b 3RW44 Sirius softstarter with built-in OL
b Built-in graphical LCD keypad and bypass The 3RW44 severe duty rating table should
b Internal self protection be applied for high inertia applications
b Fault monitoring b Circuit breaker with disconnect
such rock crushers, chippers, screw
b 3 parameter sets b Control circuit transformer compressors, ect.
b Communication capable via opt. Profibus b Reset button
module Class 74 starters are built to UL and CSA
b Programmable inputs and outputs standards.
b External keypad available
Rated MAX HP
a KW Class 20 Severe Duty (350% * Im for 20s)b
Operating OPEN Style List List List List NEMA 4/4X List
Current 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ NEMA 3R Price $ NEMA 12 Price $ NEMA 4 Price $ Stainless Steel Price $
26 7.5 7.5 15 — 12 3RW4422-1BC34 74AT3_BFAP 74AT3_DFAP 74AT3_0FAP 74AT3_EFAP 74AT3_WFAP
32 10 10 20 — 15 3RW4423-1BC34 74BT3_BFAP 74BT3_DFAP 74BT3_0FAP 74BT3_EFAP 74BT3_WFAP
42 10 15 25 — 19 3RW4424-1BC34 74CT3_BFAP 74CT3_DFAP 74CT3_0FAP 74CT3_EFAP 74CT3_WFAP
51 15 15 30 — 22 3RW4425-1BC34 74DT3_BFAP 74DT3_DFAP 74DT3_0FAP 74DT3_EFAP 74DT3_WFAP
68 20 25 50 — 37 3RW4426-1BC34 74ET3_BFAP 74ET3_DFAP 74ET3_0FAP 74ET3_EFAP 74ET3_WFAP
82 25 30 60 — 45 3RW4427-1BC34 74FT3_BFAP 74FT3_DFAP 74FT3_0FAP 74FT3_EFAP 74FT3_WFAP
97 30 30 60 — 45 3RW4434-6BC34 74GT3_BFAP 74GT3_DFAP 74GT3_0FAP 74GT3_EFAP 74GT3_WFAP
113 30 40 75 — 56 3RW4435-6BC34 74HT3_BFAP 74HT3_DFAP 74HT3_0FAP 74HT3_EFAP 74HT3_WFAP
134 40 50 75 — 56 3RW4436-6BC34 74JT3_BFAP 74JT3_DFAP 74JT3_0FAP 74JT3_EFAP 74JT3_WFAP
175 50 60 100 — 75 3RW4443-6BC34 74KT3_BFAP 74KT3_DFAP 74KT3_0FAP 74KT3_EFAP
195 60 75 125 — 93 3RW4444-6BC34 74LT3_BFAP 74LT3_DFAP 74LT3_0FAP 74LT3_EFAP
243 75 75 150 — 112 3RW4445-6BC34 74MT3_BFAP 74MT3_DFAP 74MT3_0FAP 74MT3_EFAP
263 75 100 200 — 149 3RW4446-6BC34 74NT3_BFAP 74NT3_DFAP 74NT3_0FAP 74NT3_EFAP
326 100 125 250 — 186 3RW4447-6BC34 74PT3_BFAP 74PT3_DFAP 74PT3_0FAP 74PT3_EFAP
494 150 150 400 — 224 3RW4453-6BC34 74QT3_BFAT 74QT3_DFAT 74QT3_0FAT 74QT3_EFAT
7
551 150 200 450 — 298 3RW4454-6BC34 74RT3_BFAT 74RT3_DFAT 74RT3_0FAT 74RT3_EFAT
615 200 200 500 — 336 3RW4455-6BC34 74ST3_BFAT 74ST3_DFAT 74ST3_0FAT 74ST3_EFAT
634 200 250 500 — 373 3RW4456-6BC34 74TT3_BFAT 74TT3_DFAT 74TT3_0FAT 74TT3_EFAT
SOFT STARTERS
650 200 250 550 — 410 3RW4457-6BC34 74WT3_BFAT 74WT3_DFAT 74WT3_0FAT 74WT3_EFAT
880 300 350 700 — 522 3RW4465-6BC34 74YT3_BFAT 74YT3_0FAT
940 300 350 750 — 559 3RW4466-6BC34 74ZT3_BFAT 74ZT3_0FAT
200V 6 6 6 6 6
230V 2 2 2 2 2
380V 3 3 3 3 3
460V 4 4 4 4 4
26 — — 15 20 — 3RW4422-1BC35 74AT35BFAP 74AT35DFAP 74AT350FAP 74AT35EFAP 74AT35WFAP
32 — — 20 25 — 3RW4423-1BC35 74BT35BFAP 74BT35DFAP 74BT350FAP 74BT35EFAP 74BT35WFAP
42 — — 25 30 — 3RW4424-1BC35 74CT35BFAP 74CT35DFAP 74CT350FAP 74CT35EFAP 74CT35WFAP
51 — — 30 40 — 3RW4425-1BC35 74DT35BFAP 74DT35DFAP 74DT350FAP 74DT35EFAP 74DT35WFAP
68 — — 50 50 — 3RW4426-1BC35 74ET35BFAP 74ET35DFAP 74ET350FAP 74ET35EFAP 74ET35WFAP
82 — — 60 75 — 3RW4427-1BC35 74FT35BFAP 74FT35DFAP 74FT350FAP 74FT35EFAP 74FT35WFAP
97 — — 60 75 — 3RW4434-6BC35 74GT35BFAP 74GT35DFAP 74GT350FAP 74GT35EFAP 74GT35WFAP
113 — — 75 100 — 3RW4435-6BC35 74HT35BFAP 74HT35DFAP 74HT350FAP 74HT35EFAP 74HT35WFAP
134 — — 75 125 — 3RW4436-6BC35 74JT35BFAP 74JT35DFAP 74JT350FAP 74JT35EFAP 74JT35WFAP
175 — — 100 150 — 3RW4443-6BC35 74KT35BFAP 74KT35DFAP 74KT350FAP 74KT35EFAP
195 — — 125 200 — 3RW4444-6BC35 74LT35BFAP 74LT35DFAP 74LT350FAP 74LT35EFAP
243 — — 150 200 — 3RW4445-6BC35 74MT35BFAP 74MT35DFAP 74MT350FAP 74MT35EFAP
263 — — 200 250 — 3RW4446-6BC35 74NT35BFAP 74NT35DFAP 74NT350FAP 74NT35EFAP
326 — — 250 300 — 3RW4447-6BC35 74PT35BFAP 74PT35DFAP 74PT350FAP 74PT35EFAP
494 — — 400 500 — 3RW4453-6BC35 74QT35BFAT 74QT35DFAT 74QT350FAT 74QT35EFAT
551 — — 450 550 — 3RW4454-6BC35 74RT35BFAT 74RT35DFAT 74RT350FAT 74RT35EFAT
615 — — 500 600 — 3RW4455-6BC35 74ST35BFAT 74ST35DFAT 74ST350FAT 74ST35EFAT
693 — — 500 650 — 3RW4456-6BC35 74TT35BFAT 74TT35DFAT 74TT350FAT 74TT35EFAT
780 — — 550 700 — 3RW4457-6BC35 74WT35BFAT 74WT35DFAT 74WT350FAT 74WT35EFAT
880 — — 700 850 — 3RW4465-6BC35 74YT35BFAT 74YT350FAT
940 — — 750 900 — 3RW4466-6BC35 74ZT35BFAT 74ZT350FAT
a Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor.
HPs are for reference only. Enclosed ratings are at 40°C.
b Starter selection is dependent on type of application. Im = FLA rating of motor.
Product Category IEC Smart Infrastructure, Industrial Control Catalog 2021 7/121
Soft Starters
Enclosed 3RW44
Ordering Information
� nclosed devices should be ordered by
E Ideal applications for 3RW44 enclosed
the FLA of the motor. softstarters:
� he 3RW44 is designed for normal
T b Fans
starting applications. b Pumps
3RW44 Enclosed features: b Conveying systems and lifts
� or factory modifications see page 7/124.
F b Hydraulics
b Available in NEMA 1, 12, 3R, 4, and 4
stainless steel � or dimensional drawings see page 7/125.
F b Machine tools
b Compact size Class 74 non-combination starters include: b Mills saws
b Built-in bypass contactor b Crushers and grinders
b Multiple starting/stopping techniques b NEMA rated enclosure
including torque control b Mixers
b 3RW44 Sirius softstarter with built-in OL b HVAC systems
b Internal overload class 5, 10, 15, 20, or 30 and bypass
b Built-in graphical LCD keypad b Fusible disconnect The 3RW44 severe duty rating table should
b Internal self protection be applied for high inertia applications
b Fault monitoring b Control circuit transformer
such rock crushers, chippers, screw
b 3 parameter sets b Reset button compressors, ect.
b Communication capable via opt. Profibus
module Class 74 starters are built to UL and CSA
b Programmable inputs and outputs standards.
b External keypad available
For all technical information, please consult the 2006 Industrial Controls Catalog or contact your local sales support center.
Rated MAX HP
a KW Class 10 Light Duty b (350% * Im for 10s)
Operating OPEN Style List List List List NEMA 4/4X List
Current 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ NEMA 3R Price $ NEMA 12 Price $ NEMA 4 Price $ Stainless Steel Price $
26 7.5 7.5 15 — 12 3RW4422-1BC34 74AT3_BFAF 74AT3_DFAF 74AT3_0FAF 74AT3_EFAF 74AT3_WFAF
32 10 10 20 — 15 3RW4423-1BC34 74BT3_BFAF 74BT3_DFAF 74BT3_0FAF 74BT3_EFAF 74BT3_WFAF
42 10 15 25 — 19 3RW4424-1BC34 74CT3_BFAF 74CT3_DFAF 74CT3_0FAF 74CT3_EFAF 74CT3_WFAF
51 15 15 30 — 22 3RW4425-1BC34 74DT3_BFAF 74DT3_DFAF 74DT3_0FAF 74DT3_EFAF 74DT3_WFAF
68 20 25 50 — 37 3RW4426-1BC34 74ET3_BFAF 74ET3_DFAF 74ET3_0FAF 74ET3_EFAF 74ET3_WFAF
82 25 30 60 — 45 3RW4427-1BC34 74FT3_BFAF 74FT3_DFAF 74FT3_0FAF 74FT3_EFAF 74FT3_WFAF
100 30 30 75 — 56 3RW4434-6BC34 74GT3_BFAF 74GT3_DFAF 74GT3_0FAF 74GT3_EFAF 74GT3_WFAF
117 30 40 75 — 56 3RW4435-6BC34 74HT3_BFAF 74HT3_DFAF 74HT3_0FAF 74HT3_EFAF 74HT3_WFAF
145 40 50 100 — 75 3RW4436-6BC34 74JT3_BFAF 74JT3_DFAF 74JT3_0FAF 74JT3_EFAF 74JT3_WFAF
180 60 60 125 — 93 3RW4443-6BC34 74KT3_BFAF 74KT3_DFAF 74KT3_0FAF 74KT3_EFAF
215 60 75 150 — 112 3RW4444-6BC34 74LT3_BFAF 74LT3_DFAF 74LT3_0FAF 74LT3_EFAF
280 75 100 200 — 149 3RW4445-6BC34 74MT3_BFAF 74MT3_DFAF 74MT3_0FAF 74MT3_EFAF
7
315 100 125 250 — 186 3RW4446-6BC34 74NT3_BFAF 74NT3_DFAF 74NT3_0FAF 74NT3_EFAF
385 125 150 300 — 224 3RW4447-6BC34 74PT3_BFAF 74PT3_DFAF 74PT3_0FAF 74PT3_EFAF
494 150 200 400 — 298 3RW4453-6BC34 74QT3_BFAF 74QT3_0FAF
SOFT STARTERS
7/122 Smart Infrastructure, Industrial Control Catalog 2021 Product Category IEC
Soft Starters
Enclosed 3RW44
Ordering Information
� nclosed devices should be ordered by
E Ideal applications for 3RW44 enclosed
the FLA of the motor. softstarters:
� he 3RW44 is designed for normal
T b Fans
starting applications. b Pumps
3RW44 Enclosed features: b Conveying systems and lifts
� or factory modifications see page 7/124.
F b Hydraulics
b Available in NEMA 1, 12, 3R, 4, and 4
stainless steel � or dimensional drawings see page 7/125.
F b Machine tools
b Compact size Class 74 non-combination starters include: b Mills saws
b Built-in bypass contactor b Crushers and grinders
b Multiple starting/stopping techniques b NEMA rated enclosure
including torque control b Mixers
b 3RW44 Sirius softstarter with built-in OL b HVAC systems
b Internal overload class 5, 10, 15, 20, or 30 and bypass
b Built-in graphical LCD keypad b Fusible disconnect The 3RW44 severe duty rating table should
b Internal self protection be applied for high inertia applications
b Fault monitoring b Control circuit transformer
such rock crushers, chippers, screw
b 3 parameter sets b Reset button compressors, ect.
b Communication capable via opt. Profibus
module Class 74 starters are built to UL and CSA
b Programmable inputs and outputs standards.
b External keypad available
For all technical information, please consult the 2006 Industrial Controls Catalog or contact your local sales support center.
Rated MAX HP
a KW Class 20 Severe Duty (350% * Im for 20s)b
Operating OPEN Style List List List List NEMA 4/4X List
Current 200V 230V 460V 575V 380V (Starter Only) NEMA 1 Price $ NEMA 3R Price $ NEMA 12 Price $ NEMA 4 Price $ Stainless Steel Price $
26 7.5 7.5 15 — 12 3RW4422-1BC34 74AT3_BFAF 74AT3_DFAF 74AT3_0FAF 74AT3_EFAF 74AT3_WFAF
32 10 10 20 — 15 3RW4423-1BC34 74BT3_BFAF 74BT3_DFAF 74BT3_0FAF 74BT3_EFAF 74BT3_WFAF
42 10 15 25 — 19 3RW4424-1BC34 74CT3_BFAF 74CT3_DFAF 74CT3_0FAF 74CT3_EFAF 74CT3_WFAF
51 15 15 30 — 22 3RW4425-1BC34 74DT3_BFAF 74DT3_DFAF 74DT3_0FAF 74DT3_EFAF 74DT3_WFAF
68 20 25 50 — 37 3RW4426-1BC34 74ET3_BFAF 74ET3_DFAF 74ET3_0FAF 74ET3_EFAF 74ET3_WFAF
82 25 30 60 — 45 3RW4427-1BC34 74FT3_BFAF 74FT3_DFAF 74FT3_0FAF 74FT3_EFAF 74FT3_WFAF
97 30 30 60 — 45 3RW4434-6BC34 74GT3_BFAF 74GT3_DFAF 74GT3_0FAF 74GT3_EFAF 74GT3_WFAF
113 30 40 75 — 56 3RW4435-6BC34 74HT3_BFAF 74HT3_DFAF 74HT3_0FAF 74HT3_EFAF 74HT3_WFAF
134 40 50 75 — 56 3RW4436-6BC34 74JT3_BFAF 74JT3_DFAF 74JT3_0FAF 74JT3_EFAF 74JT3_WFAF
175 50 60 100 — 75 3RW4443-6BC34 74KT3_BFAF 74KT3_DFAF 74KT3_0FAF 74KT3_EFAF
195 60 75 125 — 93 3RW4444-6BC34 74LT3_BFAF 74LT3_DFAF 74LT3_0FAF 74LT3_EFAF
243 75 75 150 — 112 3RW4445-6BC34 74MT3_BFAF 74MT3_DFAF 74MT3_0FAF 74MT3_EFAF
7
263 75 100 200 — 149 3RW4446-6BC34 74NT3_BFAF 74NT3_DFAF 74NT3_0FAF 74NT3_EFAF
326 100 125 250 — 186 3RW4447-6BC34 74PT3_BFAF 74PT3_DFAF 74PT3_0FAF 74PT3_EFAF
494 150 150 400 — 298 3RW4453-6BC34 74QT3_BFAF 74QT3_0FAF
SOFT STARTERS
551 150 200 450 — 336 3RW4454-6BC34 74RT3_BFAF 74RT3_0FAF
615 200 200 500 — 373 3RW4455-6BC34 74ST3_BFAF 74ST3_0FAF
634 200 250 500 — 373 3RW4456-6BC34 74TT3_BFAF 74TT3_0FAF
650 200 250 550 — 373 3RW4457-6BC34 74WT3_BFAF 74WT3_0FAF
200V 6 6 6 6 6
230V 2 2 2 2 2
380V 3 3 3 3 3
460V 4 4 4 4 4
26 — — 15 20 — 3RW4422-1BC35 74AT35BFAF 74AT35DFAF 74AT350FAF 74AT35EFAF 74AT35WFAF
32 — — 20 25 — 3RW4423-1BC35 74BT35BFAF 74BT35DFAF 74BT350FAF 74BT35EFAF 74BT35WFAF
42 — — 25 30 — 3RW4424-1BC35 74CT35BFAF 74CT35DFAF 74CT350FAF 74CT35EFAF 74CT35WFAF
51 — — 30 40 — 3RW4425-1BC35 74DT35BFAF 74DT35DFAF 74DT350FAF 74DT35EFAF 74DT35WFAF
68 — — 50 50 — 3RW4426-1BC35 74ET35BFAF 74ET35DFAF 74ET350FAF 74ET35EFAF 74ET35WFAF
82 — — 60 75 — 3RW4427-1BC35 74FT35BFAF 74FT35DFAF 74FT350FAF 74FT35EFAF 74FT35WFAF
97 — — 60 75 — 3RW4434-6BC35 74GT35BFAF 74GT35DFAF 74GT350FAF 74GT35EFAF 74GT35WFAF
113 — — 75 100 — 3RW4435-6BC35 74HT35BFAF 74HT35DFAF 74HT350FAF 74HT35EFAF 74HT35WFAF
134 — — 75 125 — 3RW4436-6BC35 74JT35BFAF 74JT35DFAF 74JT350FAF 74JT35EFAF 74JT35WFAF
175 — — 100 150 — 3RW4443-6BC35 74KT35BFAF 74KT35DFAF 74KT350FAF 74KT35EFAF
195 — — 125 200 — 3RW4444-6BC35 74LT35BFAF 74LT35DFAF 74LT350FAF 74LT35EFAF
243 — — 150 200 — 3RW4445-6BC35 74MT35BFAF 74MT35DFAF 74MT350FAF 74MT35EFAF
263 — — 200 250 — 3RW4446-6BC35 74NT35BFAF 74NT35DFAF 74NT350FAF 74NT35EFAF
326 — — 250 300 — 3RW4447-6BC35 74PT35BFAF 74PT35DFAF 74PT350FAF 74PT35EFAF
494 — — 400 500 — 3RW4453-6BC35 74QT35BFAF 74QT350FAF
551 — — 450 550 — 3RW4454-6BC35 74RT35BFAF 74RT350FAF
615 — — 500 600 — 3RW4455-6BC35 74ST35BFAF 74ST350FAF
693 — — 550 650 — 3RW4456-6BC35 74TT35BFAF 74TT350FAF
780 — — 600 700 — 3RW4457-6BC35 74WT35BFAF 74WT350FAF
a Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor. b Starter selection is dependent on type of application. Im = FLA rating of motor.
HPs are for reference only. Enclosed ratings are at 40°C.
Product Category IEC Smart Infrastructure, Industrial Control Catalog 2021 7/123
Soft Starters
Factory Modifications
3RW Enclosure
Emergency HP Rated Bypass Starter Version Class NEMA Type Mod Suffix
3RW40ab 73/74 1/12/3R/4 A12
Available Modifications
Requiring the MODIFIED OPTIONS Box Size 3RW Enclosure
(to be used with the selections ending in GA*) Version Class NEMA Type Mod Suffix
Isolation Contactor 3RW40/44 73/74 1/12/3R/4 IC
100 VA Extra CPT Capacity 3RW40/44 73/74 ALL CA
Space Heater (120V separate control) 3RW40/44 73/74 ALL SH
Space Heater w/ T-stat (120V separate control) 3RW40/44 73/74 ALL ST
Lightning Arrestor 3RW40/44 73/74 ALL L
a (A) For sizes 73YT & 73ZT, mods IC & A12 are available individually or together; Isolation contactor IC is included as standard with version 3RW40 model R (4th
(B) For sizes 74YT & 74ZT (combination w\CB), mods IC & A12 are only available character of the cat. no.) soft starters.
individually (NOT together); (C) For sizes 74YT & 74ZT (combination w\ fusible disc), d Pilot lights are transformer type as standard. For LED type bulbs, order suffix FE in
mods IC & A12 are NOT available individually or together. addition to the standard device suffix(es). For example, to order red “ON” and green
An isolation contactor is included with the emergency HP rated bypass starter for “OFF” pilot lights with LED bulbs, order FA, FK and FE.
version 3RW40 soft starters.
7/124 Smart Infrastructure, Industrial Control Catalog 2021 Product Category IEC
Soft Starters
Class 73, 74
Dimensions are in inches and are for reference only (not for construction). Certain styles may deviate from values indicated.
7
970 - 1076 90 50 20
Amps A B C
3RW40new 11- 98 55 29 11 N1, N12 Fusible
SOFT STARTERS
117 36 18 15
Amps A B C
3RW40 145 - 205A 36 22 20
248 - 385 54 36 20 3RW44 494-780 90 50 20
26 - 51 26 12.5 15
68 - 82 36 18 15
3RW44 N4X Stainless Steel Standard Enclosure
100 - 117 36 22 20
145 - 385 54 36 20 Amps A B C
3RW40new 11- 98 55 29 11
117 - 145 54 36 20
N1, N3R, N12, N4 Modified Enclosure 3RW40
205 - 300 90 40 20
Amps A B C 26 - 42 36 23 15
3RW40 117-385 56 36 20 51 - 100 50 25 20
26-51 36 22 20 3RW44
3RW44 117 - 145 54 36 20
68-385 54 36 20 180 - 385 90 40 20
N4X Stainless Steel Modified Enclosure N1, N3R, N12, N4 Modified Enclosure
Amps A B C
Amps A B C
117 - 248 76 30 20
3RW40 117-385 54 36 20
3RW40 315 90 30 20
26-51 36 22 20
3RW44 385 90 40 20
68-385 54 36 20
26 - 215 76 30 20
3RW44 280 90 30 20
315 - 385 90 40 20
Class 73, 74
7
SOFT STARTERS
SINAMICS G120X
Introduction
SINAMICS G120X
An infrastructure drive for pumps, fans
and compressors
Siemens introduces an exciting new addition to the existing
SINAMICS product portfolio — the G120X — an “infrastructure”
drive up to 700 hp (630kW), which is targeted for pump, fan
and compressor applications in the water / wastewater, HVAC,
irrigation / agriculture and industrial chiller and refrigeration
industries.
Seamless process for higher efficiency
SINAMICS G120X is simple, seamless, cost- and energy-
efficient, robust, reliable and fit for digitalization. It integrates
easily into existing applications, works with any standard motor
(induction, synchronous and synchronous reluctance) and can be
configured for cost-optimization and resource-saving operation
which ultimately helps reduce total cost of ownership. SINAMICS
G120X meets all the latest industry standards with regard to
energy efficiency and product safety, and offers enhanced safety
with SIL3-rated safety functions and up to 100kA short-circuit
current rating according to new UL61800-5-1 design.
Application functions
Pump-specific
Service mode
n
7
Fan-specific
n Flying restart n Fire mode (essential service mode)
DRIVES
n Automatic restart n No load, torque and rotation (belt) monitoring with sensor
n Skip frequency bands
n Eco mode n Bypass mode n Support to high efficiency motors (PMSM and SRM)
n Hibernation or sleep mode n Energy / flow calculator n Real time clock and programmable timer (3)
Optimize pump and fan operation and increase system availability
Protection functions
n Phase-loss detection for both supply and motor n Motor overload monitoring and protection
n Overvoltage controller n Motor short-circuit and ground fault protection
n Undervoltage controller n Speed and torque monitoring
n Drive overtemperature protection n Blocking and stalling monitoring and protection
n Loss of analog input signal monitoring n Detection of missing communication telegrams
n External fault and warning monitoring (up to 3) n Detection of communication bus interruption
n Motor overtemperature protection (with and without sensor)
SINAMICS G120X
Technical data
Technical data
Line voltage and output power range
FSA…FSF 3AC 200V (-20%)…240V (+10%) 1 hp…75 hp (0.75kW…55kW)
FSA…FSG 3AC 380V (-20%)…480V (+10%) 1 hp…400 hp (0.75kW…250kW)
FSH, FSJ 3AC 380V (-15%)…480V (+10%) 400 hp…700 hp (315kW…560kW)
FSD…FSG 3AC 500V (-20%)…690V (+10%) 4 hp…250 hp (3kW…250kW)
FSH, FSJ 3AC 500V (-15%)…690V (+10%) 350 hp…700 hp (315kW…630kW)
Output voltage 3AC 0V….line voltage x 0.97
Input frequency 47 Hz…63 Hz
Output frequency
FSA…FSG 0 Hz…550 Hz (depending upon the control mode)
FSH, FSJ 0 Hz…150 Hz (depending upon the control mode)
Fundamental power factor (Cos φ) 0.96…0.99
Efficiency class IE2 (Based on power losses according to EN 50598-2 and IEC 61800-9-2)
Efficiency (η) 98%
Motor control n V/Hz control (linear, linear with flux current control / FCC, parabolic and eco mode)
n Sensorless less vector control (SLVC)
Supported motor types n Asynchronous (induction) motor
n Permanent magnet synchronous motor (PMSM)
n Synchronous reluctance motor (SRM)
2 Analog Inputs (AI 0…AI 1) Differential input 0V… 10V or -10V … +10V: typical current drain: 0.1 mA,
max. voltage 35V
DRIVES
0/4 mA ... 20 mA: 120 Ω input resistance, voltage < 10V, current < 80 mA
1 Analog Output (AO 0) Not isolated, switchable between voltage (0V… 10V) and current
(0/4 mA ... 20 mA) via parameter setting
1 motor temperature sensor input PTC, KTY, PT1000, bi-metallic switch with normally closed contact
1 failsafe digital input STO — electrically isolated
1 internal aux. supply voltage
24V DC, max. 250 mA
10V DC, max. 10 mA
1 external aux. supply voltage 24V DC (20.4 … 28.8V DC), current consumption 0.5A
1 memory card slot For optional SD memory cards (as a backup storage device for saving of the settings after drive com-
missioning, and also for a series commissioning of a several identical drives via cloning of the settings)
Additional control inputs and outputs (With optional I/O Extension Module)
2 Digital Inputs (DI 6…DI 7) 24V (12–30V) electrically isolated, 4mA current, PNP / NPN switchable
4 Digital (Relay) Outputs (DO 2…DO 5) 2x Type A and 2x Type C relay outputs rated 250V AC, 2A / 30V DC, 2A for resistive,
inductive or capacitive load
1 Analog Input (AI 2) Analog current input (0/4 mA … 20 mA) or Temperature sensor input
(Pt10000 / LG-Ni10000 / DIN-Ni1000)
1 motor temperature sensor input (AI 3) Temperature sensor input (Sensor Pt10000 / LG-Ni10000 / DIN-Ni1000)
2 Analog Output (AO 1 … AO 2) Not isolated, switchable between voltage (0V… 10V) and current (0/4 mA ... 20 mA)
via parameter setting
User interface
Standard Intelligent Operator Panel (IOP-2) — a high-resolution graphical color keypad
Optional Smart Access Module (SAM) Part number: 6SL3255-0AA00-5AA0 — a WiFi-based web server module and
engineering tool for quick setup and diagnostics using
a mobile device (PC, smartphone, tablet, etc.)
Basic Operator Panel (BOP-2) — a basic keypad
Blank (no Operator Panel / keypad)
SINAMICS G120X
General data
SINAMICS G120X
It’s the simple, seamless and easy-to-use drive — right out of the box.
Digitalization
Digitalization and IoT based secured health monitoring
SINAMICS CONNECT 300 SINAMICS CONNECT 300 (Part number: 6SL3255-0AG30-0AA0) is the
and IoT gateway. It is designed to acquire data through the serial port of the
Analyze MyDrives SINAMICS G120X and synchronize the data to MindSphere (cloud-based
open IoT operating system of Siemens) using the MindSphere application
Analyze MyDrives (AMD).
Certification
n CULUS
marking according to UL61800-5-1 and CSA C22.2 No. 274 with
Certification /
SCCR up to 100kA
marking
n CE marking according to European Low-Voltage Directive 2014/35/
EU EU and IEC/EN 61800-5-1, Machinery directive 2006/42/EC and IEC/
EN 61800-5-2, EMC Directive 2014/30/EU and IEC/EN 61800-3, RoHS
directive 2011/65/EU and EN 50581
n IE2efficiency level based on power losses according to EN 50598-2 and
IEC 61800-9-2
n Safe torque off (STO) SIL3 rating according to IEC/EN 61800-5-2
n EAC, K, RCM (formerly C-Tick), REACH, RoHS II, SEMI F47
Additional D
Dimensions and clearance distances FSA...FSJ depth
7
size mm (inch) mm (inch) mm (inch) mm (inch)
DRIVES
FSB 275 (10.8) 100 (3.9) 209 (8.2) 5.8 (12.8) 6.2 (13.7)
n For additional technical information including operating instructions please visit SINAMICS
G120X Technical Reference site: https://support.industry.siemens.com/cs/us/en/ps/25454
SINAMICS G120X
Selection and ordering data
EMC class
No EMI / RFI filter U
Communication interface
PROFINET, EtherNet / IP™ (Standard) F
USS, Modbus, RTU, BACnet MS / TP B
PROFIBUS DP P
*Special coating or sealing for operation in harsh / corrosive environments
SINAMICS G120X
Selection and ordering data
7
560 700 830 6 S L 3 2 2 0 – Y E 6 6 – C 0
Special coating according to IEC/EN 60721-3-3
DRIVES
Class 3C2 (Standard) 2
Class 3C3* 3
User interface
Blank (No operator panel / keypad) 1
BOP-2 (Basic keypad, Class 3C3*) 2
IOP-2 (Standard — high-resolution graphical color keypad, Class 3C3*) 3
I / O extension module
without I/O extenstion module 0
with I/O extenstion module, Class 3C3* 1
EMC class
No filter (Standard — without integrated EMI / RFI filter) for FSA to FSF only U
Filter C2 (With integrated EMI / RFI filter Category C2) for FSA to FSG only, see Note 1 A
Filter C3 (Standard — with integrated EMI / RFI filter Category C3) for FSG to FSJ only, see Note 1 C
Communication interface
PROFINET, EtherNet / IP™ (Standard) F
USS, Modbus, RTU, BACnet MS / TP B
PROFIBUS DP P
*Special coating or sealing for operation in harsh / corrosive environments
Note 1: For frame sizes FSG, FSH and FSJ, the filter can be deactivated by removing a grounding screw / clip for applications in an ungrounded or
a high-resistance grounded or a corner-grounded supply system. Please refer to the SINAMICS G120X Operating Instructions for more information.
SINAMICS G120X
Selection and ordering data
Class 3C3* 3
DRIVES
User interface
Blank (No operator panel / keypad) 1
BOP-2 (Basic keypad, Class 3C3*) 2
IOP-2 (Standard — high-resolution graphical color keypad, Class 3C3*) 3
I / O extension module
without I/O extenstion module 0
with I/O extenstion module, Class 3C3* 1
EMC class
No filter (Standard — without integrated EMI / RFI filter) for FSD to FSF only U
Filter C2 (With integrated EMI / RFI filter Category C2) for FSD to FSE only A
Filter C3 (With integrated EMI / RFI filter Category C3) for FSF to FSJ only, standard for FSG to FSJ, see Note 1 C
Communication interface
PROFINET, EtherNet / IP™ (Standard) F
USS, Modbus, RTU, BACnet MS / TP B
PROFIBUS DP P
*Special coating or sealing for operation in harsh / corrosive environments
Note 1: For frame sizes FSG, FSH and FSJ, the filter can be deactivated by removing a grounding screw / clip for applications in an ungrounded or
a high-resistance grounded or a corner-grounded supply system. Please refer to the SINAMICS G120X Operating Instructions for more information.
SINAMICS G120X
Push-through kits, Options and Features
7
FSA 6SL3261-6GA00-0BA0 127 (5.0) 324 (12.8) 234 (9.2) 160 (6.3) 57 (2.2)
FSB 6SL3261-6GB00-0BA0 154 (6.1) 384 (15.1) 279 (11.0) 153 (6.0) 66 (2.6)
DRIVES
FSC 6SL3261-6GC00-0BA0 192 (7.6) 407 (16.0) 295 (11.6) 154 (6.1) 65 (2.6)
FSD 6SL3261-6GD00-0BA0 271 (10.7) 647 (25.5) 514 (20.2) 142 (5.6) 98 (3.9)
FSE 6SL3261-6GE00-0BA0 360 (14.2) 773 (30.4) 600 (23.6) 145 (5.7) 93 (3.7)
FSF 6SL3261-6GF00-0BA0 396 (15.6) 1003 (39.5) 749 (29.5) 185 (7.3) 185 (7.3)
FSG 6SL3261-6GG00-0BA0 384 (15.1) 1275 (50.2) 1026 (40.4) 184 (7.3) 188 (7.4)
n Special coating (Class 3C3) for operation of a drive in the harsh n Output dv / dt filter
environments where corrosive gases for example, Hydrogen Sulfide
n Output Sinusoidal filter
(H2S), Chlorine (Cl) or Ammonia (NH3) are often present
n Passive line harmonic filter
n Add-on Push-Through (PT) kit to enable UL Open Type / IP20 drive in
to UL Open Type / IP20 push-through drive (up to FSG) n EMI / RFI filters
n Input and output reactors n Communication:
PROFINET, EtherNet / IP™, USS,
Modbus RTU, BACnet MS / TP and PROFIBUS DP
n I/O extension module
Notes
7
DRIVES