JP15
STANDARD SPECIFICATIONS
                                                                                                                       1. ENGINE
                                                                                                                      Perkins four stroke heavy duty high performance
                                                                                                                      industrial type diesel engine.
                                                                                                                      2. ENGINE FILTRATION SYSTEM
                                                                                                                      • Air filter.
                                                                                                                      • Fuel filter.
                                                                                                                      • Full flow lube oil filter.
                                                                                                                      All filters have replaceable elements.
                                                                                                                      3. COOLING RADIATOR
                                                                                                                      Radiator and cooling fan, complete with safety
                                                                                                                      guards, designed to cool the engine at high ambient
                                                                                                                      temperatures (consult your dealer for de-ration factors)
                                                                                                                      4. EXHAUST SYSTEM
                                                                                                                      Heavy duty Industrial Exhaust Silencer
 POWERED BY:                                                                                                           Silencer noise reduction level        22 (dB)
                                                                                                                       Maximum allowable back pressure       10.0 (kPa)
                                                                                                                      5. CIRCUIT BREAKER TYPE
                                                                                                                      ABB 3 pole MCB. (4 pole is optional)
                                                                                                                                                                          (contd.)
GENERATING SET MODEL (JP15)                                                                                          A
Output Ratings                               Prime                                      Standby                      Make
                                                                                                                        Leroy Somer
380-415 V, 3 ph, 50 Hz, 1500 rpm             15 KVA                                     16.5 KVA                     ModelTAL040D
                                             12 KW                                      13.2 KW                      No.        1
230V, 1 ph, 50 Hz, 1500 rpm                  10.5 KVA                                   11.5 KVA                     Insulation H
                                             8.5 KW                                     9 KW                         T at-noonload <3.5%
                                                                                                                               load <5%
                                                                                      Ratings at 0.8 Power Factor    Wires 6
ENGINE / TECHNICAL DATA                                                                                                      IP23
Engine Make                                                                 Perkins                                        SHUNT
Engine Model                                                             403A-15G2                                   Winding
                                                                                                                         2/3 (wdg 3)
Governing Type                                                            Mechanical                                 A       R120
Number of Cylinders                                                            3                                         2250 min-1
                                                                                                                     Overspeed
Cylinder Arrangement                                                    Vertical in line                                     ± 1%
Bore and Stroke mm                                                          84 x 90                                             -
Displacement / Cubic Capacity litres                                    1.496                                         PMG Excitation System Available as Optional.
Induction System                                                 Naturally Aspirated
                                                                                                                    CONTROL PANEL
Cycle                                                                  4 stroke
                                                                                                                    Make                                     Deep Sea
Combustion System                                                 Indirect Injection
                                                                                                                    Model                                    DSE6110
Compression Ratio                                                       22.5:1
Rotation                                                 Anti-clockwise, viewed on flywheel                          The DSE6110 is an Auto Start Control Module for
                                                                                                                    single genset applications. It includes a backlit LCD
Cooling System                                                      Water - cooled
                                                                                                                    display which clearly shows the status of the
Frequency and Engine Speed                                        50Hz & 1500rpm                                    engine all the times. This module can either be
                                                        Prime                        Standby                        programmed
                                                                                                                    using    the front panel or by using the DSE
Gross Engine Power kW (hp)                              14 (18)                      15.4 (20)                      configuration suite PC software.
                                                                                                                    • Underspeed, Overspeed
Fuel Consumption @ 50%100%load
                             loadL/hr
                                  L/hr                    4.3
                                                          2.2                           5.0
                                                                                         -                          Metering and Alarm indications:
                                                                                                                    • Generator volts (L-L, L-N)
                   @ 75%Capacity
Total Lubrication System   load L/hrlitres                3.1
                                                          6.0                            -
                                                                                        6.0                         • Generator frequency
                                                                                                                    • Generator current
Total Coolant Capacity (inc. radiator)                    6.0                           6.0                         • Engine oil pressure
litres Exhaust Temperature: °C                                                                                      • Engine coolant temperature
                                                         470                           580
                                                                                                                    • Fuel level (Warning or shutdown) - Optional
Radiator Cooling Air Flow (Min): m3/sec                  0.42                          0.42                         • Hours run r counte
Combustion Air Flow: m3/min                               1.0                           1.0                         • Battery volts
Exhaust
Fuel TankGas Flow: m3/min
          Capacity:                                       2.2                           2.2                         •• Fail to start/stop
                                                                                                                       Emergency     stop
                                                          51                            51
litres                                                                                                              • Failed to reach loading voltage/frequency
                                                                                                                    • Charge fail
DIMENSIONS AND WEIGHT                                                                                         • Loss of magnetic pick-up signal - Optional
                                                                                                               • Low DC voltage
Length cm                                     Width cm   Height cm         Weight* kg (wet)                    • CAN diagnostics and CAN fail/error
     142                                        52         110                       400                                       (Please refer to DSE6110 brochure for more details)
* For skid mounted genset without enclosure                          wet weight = with lube oil and coolant      AN INSPIRED DESIGN TO MEET YOUR NEEDS
                                                                                                                                   JP15
                                                                                                              AN INSPIRED DESIGN TO MEET YOUR NEEDS
                                                                                                                    STANDARD SPECIFICATIONS
                                                                                                              6. FUEL SYSTEM
                                                                                                              On Generating Sets up to 700 KVA, the baseframe
                                                                                                              design is incorporated with an integral fuel tank with
                                                                                                              a capacity of approx. 8 hours running at Full Load.
                                                                                                              The tank is supplied complete with fill cap
                                                                                                              breather, fuel feed and return lines to the Engine
                                                                                                              and drain plug.
                                                                                                              7. ALTERNATOR
                                                                                                              7.1 INSULATION SYSTEM
                                                                                                               • The insulation system is Class H.
                                                                                                              • All windings are impregnated in either a triple dip
                                                                                                              thermosetting liquid, oil and acid resisting polyester
                                                                                                              varnish or vacuum pressure impregnated with a
                                                                                                              special polyester resin.
                                                                                                              • Heavy coat of antitracking varnish additional
                                                                                                              protection against moisture or condensation.
                                                                                                              7.2 AUTOMATIC VOLTAGE REGULATOR (AVR)
  POWERED BY:                                                                                                 The fully sealed Automatic Voltage Regulator
                                                                                                              maintains the Voltage Regulation at ±1%. Nominal
                                                                                                              adjustment by means of a trim pot incorporated on
                                                                                                              the AVR.
                                                                                                              7.3 MOTOR STARTING
                                                                                                              An overload capacity equivalent to 300% of the Full
                                                                                                              Load impedance at zero Power Factor can be
                                                                                                              sustained for 10 seconds, when PMG option is fitted.
RATINGS DEFINITION
                                                                                                              8. MOUNTING ARRANGEMENT
Prime Power
                                                                                                              8.1 BASE FRAME
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of          The complete Generating Set is mounted as a whole
commercially purchased power. 10% overload power is available for 1 hour in 12 hours continuous               on a heavy duty fabricated steel Baseframe.
operation.
                                                                                                              8.2 COUPLING
Standby Power                                                                                                 The Engine and Alternator are directly coupled by
These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a   means of an SAE flange. The Engine flywheel is
utility power failure. No overload is permitted on these ratings.                                             flexibly coupled to the Alternator rotor.
                                                                                                              8.3 ANTI-VIBRATION MOUNTING PADS
STANDARD REFERENCE CONDITIONS                                                                                 Anti-Vibration pads are affixed between the Engine /
                                                                                                              Alternator feet and the Baseframe thus ensuring
Output ratings are presented at 25°C air inlet temperature, barometric pressure 100 kPa, relative humidity    complete vibration isolation of the rotating assembly.
30%. This generating set is designed to operate at high ambient temperatures (up to 55°C), humidity (up
to                                                                                                            8.4 SAFETY GUARDS
99%) and higher altitudes. De-ration may apply, please consult your dealer for specific site                   The Fan & Fan Drive along with the Battery Charging
ratings.                                                                                                      Alternator are Safety Guard protected for personnel
                                                                                                              protection.
Some of the specifications are not standard   on all Genset
models.                                                                                                       9. FACTORY TESTS
                                                                                                              •     The Generating set is load tested before
                                                                                                              dispatch
AVAILABLE OPTIONS & ACCESSORIES                                                                               • All protective devices control functions and site
We offer a range of optional features and accessories to tailor our generating sets to meet your power        load conditions are simulated. The generator and it’s
needs.                                                                                                        systems are checked before dispatch.
OPTIONS                                                                  ACCESSORIES                          10. EQUIPMENT FINISHING
                                                                                                              All mild steel components are fully degreased and
• A variety of generating set control and synchronizing panels               • Genuine spare                  painted with powder coated paint to ensure
parts                                                                                                         maximum scuff resistance and durability.
• Additional protection alarms and shutdowns                                    • Load
banks                                                                                                         11. DOCUMENTATIONS
                                                                                                              Operation & Maintenance manual, Circuit wiring
• Water fuel seperator                                                         • Auxiliary fuel               diagrams and Commissioning / Fault Finding instruction
tanks                                                                                                         leaflets are accompanied with the Generator.
• Water jacket heater                                                             • Manual & automatic
transfer                                                                                                      12. QUALITY STANDARDS
                                                                                                              The equipment meets the following standards:
•                                  Battery                                  charger                           BS4999, BS5000, BS5514 IEC 60034, VDE0530,
switches                                                                                                      NEMA MG 1.22 and ISO 8528.
                                                                                                              13. WARRANTY
                                                                                                              All of the Generating Sets are covered under a
                                                                                                              warranty policy for a period of 12 months. Warranty
                                                                                                              of the equipment is in line with manufacturers
                                                                                                              warranty terms & conditions.
                                                                                                              (check warranty statement for more details, as it may vary for different countries)
                                                                                                              In line with continuous product development, we reserve the
             9th National Defense Association, Al Jazeera Road, South Investors, New Cairo                    right to change specifications without notice.
   Tel: 0226109400       Mob.:01102322223         Email: info@tet-egypt.net       www.tet-egypt.net