he HYPERCELL® Flexible cable range are desi-

T gned for long service life feeders, resulting in


highly efficient signal transfer between trans-
mission equipments and antennas. The annular
corrugation of the solid copper outer conductor
allow continuous EMI/RFI shielding while offering
great strength and adequate flexibility for easy
installation in towers.
The black polyethylene jacket is fully waterproof and
ultraviolet resistant, allowing long term operation in
outdoor applications.
Other jacket material is available for fire retardancy
in indoor applications.
A full range of connectors and accessories ensure
the complete integrity of the feeder line for long
life.

Flexible
12
C a b l e

13
Inner conductor Copper wire ø
HPL50-1/4 F
2.50 + 0.05 mm
Dielectric Cellular PE ø 6.40 + 0.20 mm
Outer Conductor Corrugated copper ø 7.60 + 0.20 mm
Jacket standard Black PE ø 9.50 + 0.30 mm M 2930 Z
Options LSOH : IEC 332-3A ø 9.50 + 0.30 mm M 2932 Z
HFR : IEC 332-3A / UL1666 / K26 ø 9.50 + 0.30 mm M 5309 Z / R
Marking : ACOME - HYPERCELL® - COAX HPL 50-1/4 - Flexible - M 2930 - lot : year / week - meter
ACOME - HYPERCELL® - COAX LSOH HPL 50-1/4 - Flexible - M 2932 - lot : year / week - meter
ACOME - HYPERCELL® - COAX LSOH HFR HPL 50-1/4 - Flexible - M 5309 - lot : year / week - meter

Mechanical Connectors
characteristics Electrical
F l e x i b l e

Cable weight (kg/m) (PE) (LSOH) 0.129


Minimum bending radius (mm) 40
0.145 characteristics N male C 0066 A
Characteristic impedance (Ω) 50 + 1
Multiple bending radius (mm) 100 Max. frequency (MHz) 15.000
Number of bends 20 Relative velocity (%) 85
Tensile strength (N) 560 Capacitance (pF/m) 78.5 + 1.5 FQ Attenuation R/L Power rating
Installation temperature (°C ) - 25 / + 60 Peak power Rating (kW) 7.5 (MHz) (dB/100m) (dB) (kW)
Screening effectiveness (dB) >120 30 2.25 - 3.06
Operating temperature (°C ) - 40 / + 85
Inner conductor DC resistance (Ω/km) 3.6 80 3.71 - 1.85
Outer conductor DC resistance (Ω/km) 3.7 150 5.14 - 1.35
Max. operating voltage (V.RMS) 870 450 9.14 - 26.5 0.76
Shipping 900
960
13.27
13.75
-
-
26.5
26.5
0.53
0.52
N female C 0056 A

informations Attenuation @ 20°C (dB)


Power rating @ 40°C (kW)
1000
1500
14.06
17.54
- 26.5
-
0.50
0.40
Standard 500 m + 5% and inner conductor @100°C
1700 18.83 - 24.0 0.38
Gross weight (PE) kg 94 // 110* Return Loss max @ 20°C (dB) 1800 19.43 - 24.0 0.36
Net weight (PE // LSOH-HFR) kg 65 // 72.50 Return Loss typical - 23dB (1@3000 MHz) 2000 20.60 - 24.0 0.34
2200 21.75 - 24.0 0.33
*For sea freight Intermodulation IM3 (1800 MHz) -155 dBc max. 2500 23.37 - 23.5 0.31
(-163 dBc typical) 2700 24.42 - 23.5 0.30
For more detailed information see page 52 - 54 3000 25.80 - 0.27

Reel
ABE B
A 0.79
N male right angle C 0065 A

D
B
0.42

Grounding kits Preparation tools

C 0029 A
C 0270 A
See page 44-51 for details of accessories

14 15
Inner conductor Copper wire ø
HPL50-3/8 F
3.30 + 0.05 mm
Dielectric Cellular PE ø 8.30 + 0.20 mm
Outer Conductor Corrugated copper ø 9.50 + 0.20 mm
Jacket standard Black PE ø 11.50 + 0.30 mm M 2934 Z
Options LSOH : IEC 332-3A ø 11.50 + 0.30 mm M 2936 Z
HFR : IEC 332-3A / UL1666 / K26 ø 11.50 + 0.30 mm M 5310 Z / R
Marking : ACOME - HYPERCELL® - COAX HPL 50-3/8 - Flexible - M 2934 - lot : year / week - meter
ACOME - HYPERCELL® - COAX LSOH HPL 50-3/8 - Flexible - M 2936 - lot : year / week - meter
ACOME - HYPERCELL® - COAX LSOH HFR HPL 50-3/8 - Flexible - M 5310 - lot : year / week - meter

Mechanical Connectors
characteristics Electrical
F l e x i b l e

Cable weight (kg/m) (PE) (LSOH) 0.185 0.204 characteristics 7-16 male C 0053 A
Minimum bending radius (mm) 50 Characteristic impedance (Ω) 50 + 1
7-16 male right angle C 0052 A
Multiple bending radius (mm) 100 Max. frequency (MHz) 12.000
Number of bends 20 Relative velocity (%) 85
Capacitance (pF/m) 78 + 1.5
Tensile strength (N) 700 FQ Attenuation R/L Power rating
Peak power Rating (kW) 12.8 (MHz) (dB/100m) (dB) (kW)
Installation temperature (°C ) - 25 / + 60
Screening effectiveness (dB) >120
Operating temperature (°C ) - 40 / + 85 30 1.72 - 4.00 7-16 female C 0051 A
Inner conductor DC resistance (Ω/km) 2.10
80 2.84 - 2.44
Outer conductor DC resistance (Ω/km) 2.20 150 3.93 - 1.80
Max. operating voltage (V.RMS) 1130 450 7.01 - 26.5 0.99
Shipping 900
960
10.17
10.54
-
-
26.5
26.5
0.69
0.66
Attenuation @ 20°C (dB)
informations Power rating @ 40°C (kW) 1000 10.77 - 26.5 0.65 N male C 0064 A
and inner conductor @100°C 1500 13.47 - 0.52
Standard 500 m + 5% 1700 14.40 - 24.0 0.49
Gross weight (PE) kg 121.50 // 137.50* Return Loss max @ 20°C (dB)
1800 14.82 - 24.0 0.47
Net weight (PE // LSOH-HFR) kg 92.50 // 102.00 Return Loss typical - 23dB (1@3000 MHz) 2000 15.15 - 24.0 0.45
D Intermodulation IM3 (1800 MHz) -155 dBc max. 2200 16.00 - 24.0 0.43
*For sea freight 2700 18.03 - 23.5 0.38 N female C 0062 A
(-163 dBc typical)
3000 19.20 - 0.36
Reel
B
ABE A 0.79

For more detailed information see page 52 - 54 D


B
0.42
N male right angle C 0063 A
Preparation tools
Hangers Grounding kits

C 0291 A
See page 44-51 for details of accessories
C 0328 A C 0230 A
16 17
Inner conductor Copper clad aluminum wire ø
HPL50-1/2 F
4.80 + 0.05 mm
Dielectric Cellular PE ø 11.90 + 0.20 mm
Outer Conductor Corrugated copper ø 13.70 + 0.20 mm
Jacket standard Black PE ø 16.00 + 0.30 mm M 1473 Z
Options LSOH : IEC 332-3A ø 16.00 + 0.30 mm M 2831 Z
HFR : IEC 332-3A /UL1666 / K26 ø 16.00 + 0.30 mm M 5322 Z / R
Marking : ACOME - HYPERCELL® - COAX HPL 50-1/2 - Flexible - M 1473 - lot : year / week - meter
ACOME - HYPERCELL® - COAX LSOH HPL 50-1/2 - Flexible - M 2831 - lot : year / week - meter
ACOME - HYPERCELL® - COAX LSOH HFR HPL 50-1/2 - Flexible - M 5322 - lot : year / week - meter

Mechanical Electrical Connectors


characteristics
F l e x i b l e

Cable weight (kg/m) (PE) (LSOH) 0.250 0.276


characteristics
7-16 male C 0006 A
Characteristic impedance (Ω) 50 + 1
Minimum bending radius (mm) 70
Max. frequency (MHz) 8000 7-16 female right angle C 0050 A
Multiple bending radius (mm) 125 Relative velocity (%) 88
Number of bends 20 Capacitance (pF/m) 76 + 1.5 FQ Attenuation R/L Power rating
Peak power Rating (kW) 25.6 (MHz) (dB/100m) (dB) (kW)
Tensile strength (N) 1100
30 1.18 - 7.29 7-16 female C 0001 A
Installation temperature (°C ) - 25 / + 60 Screening effectiveness (dB) >120
Inner conductor DC resistance (Ω/km) 1.60 80 1.95 - 4.34
Operating temperature (°C ) - 40 / + 85 150 2.69 - 3.21
Outer conductor DC resistance (Ω/km) 1.60
450 4.75 - 26.5 1.81
Max. operating voltage (V.RMS) 1600 900 6.85 - 26.5 1.25 N male C 0061 A
Shipping Attenuation @ 20°C (dB)
960
1000
7.08
7.25
-
-
26.5
26.5
1.21
1.18
informations Power rating @ 40°C (kW)
and inner conductor @100°C
1500
1700
9.03
9.68 -
-
24.0
0.95
0.89 N male right angle C 0060 A
Standard 500 m + 5% Return Loss max @ 20°C (dB) 1800 10.00 - 24.0 0.86
Gross weight (PE) kg 186 // 225* Return Loss typical - 23dB (1@3000 MHz) 2000 10.62 - 24.0 0.81
Net weight (PE // LSOH-HFR) kg 125 // 138 2200 11.12 - 24.0 0.77
D
Intermodulation IM3 (1800 MHz) -155 dBc max. 2500 12.00 - 23.5 0.72 N female C 0059 A
*For sea freight (-163 dBc typical) 2700 12.53 - 23.5 0.67
Reel 3000 13.30 - 0.65
B
CBE A 1.09

EIA 7/8 C 0079 A


D
B
For more detailed information see page 52 - 54 0.52

inner 7/8 C 0084 A


Hangers and hoisting grips
Preparation tools Grounding kits
C 0319 A

C 0265 A C 0271 S
C 0332 A C 0271 A
C 0109 A C 0110 A See page 44-51 for details of accessories
C 0157 A C 0158 A C 0008 C
18 C 0199 A 19
Inner conductor Copper tube ø
HPL50-5/8 F
7.05 + 0.10 mm
Dielectric Cellular PE ø 17.20 + 0.20 mm
Outer Conductor Corrugated copper ø 19.70 + 0.20 mm
Jacket standard Black PE ø 22.50 + 0.30 mm M 5038 Z
Options LSOH : IEC 332-3A ø 22.50 + 0.30 mm M 5039 Z
HFR : IEC 332-3A - K26 ø 22.50 + 0.30 mm M 5357 Z / R
Marking : ACOME - HYPERCELL® - COAX HPL 50-5/8 - Flexible - M 5038 - lot : year / week - meter
ACOME - HYPERCELL® - COAX LSOH HPL 50-5/8 - Flexible - M 5039 - lot : year / week - meter
ACOME - HYPERCELL® - COAX LSOH HFR HPL 50-5/8 - Flexible - M 5357 - lot : year / week - meter

Mechanical Electrical Connectors


characteristics
F l e x i b l e

characteristics
Cable weight (kg/m) (PE) (LSOH) 0.448 0.500 Characteristic impedance (Ω) 50 + 1 7-16 male C 0211 A
Minimum bending radius (mm) 90 Max. frequency (MHz) 6000
Multiple bending radius (mm) 200 Relative velocity (%) 87
Number of bends 20 Capacitance (pF/m) 76.5 + 1.5 FQ Attenuation R/L Power rating 7-16 female C 0212 A
Peak power Rating (kW) 58 (MHz) (dB/100m) (dB) (kW)
Tensile strength (N) 1150 30 0.81 - 10.69
Screening effectiveness (dB) >120
Installation temperature (°C ) - 25 / + 60 Inner conductor DC resistance (Ω/km) 1.53 80 1.34 - 6.45
150 1.86 - 4.67 N male C 0208 A
Operating temperature (°C ) - 40 / + 85 Outer conductor DC resistance (Ω/km) 1.05
450 3.35 - 26.5 2.63
Max. operating voltage (V.RMS) 2400 900 4.91 - 26.5 1.82 N male right angle C 0209 A
960 5.09 - 26.5 1.73
Shipping Attenuation @ 20°C (dB)
Power rating @ 40°C (kW)
1000
1500
5.21
6.55
- 26.5
-
1.71
1.37
informations and inner conductor @100°C 1700 7.04 - 24.0 1.28 N female C 0210 A
Return Loss max @ 20°C (dB) 1800 7.27 - 24.0 1.24
Standard 500 m + 5% 2000 7.73 - 24.0 1.17
Gross weight (PE) kg 316 // 368* Return Loss typical - 23dB (1@3000 MHz)
2200 8.17 - 24.0 1.10
Net weight (PE // LSOH-HFR) kg 224 // 250 2500 8.81 - 23.5 1.02 EIA 7/8 C 0213 A
Intermodulation IM3 (1800 MHz) -155 dBc max.
(-163 dBc typical) 2700 9.22 - 23.5 0.97
*For sea freight 3000 9.82 - 0.92
Reel
B
DBE 1.25
A
EIA 7/8 right angle C 0214 A

D
B
For more detailed information see page 52 - 54 0.67

Inner 7/8 C 0084 A

Grounding Kits Hangers and hoisting grips Preparation tools

C 0292 A
C 0329 A C 0235 A
C 0331 A C 0330 A C 0200 A See page 44-51 for details of accessories

20 21
Inner conductor Copper tube ø
HPL50-7/8 F
9.00 + 0.10 mm
Dielectric Cellular PE ø 22.00 + 0.20 mm
Outer Conductor Corrugated copper ø 24.70 + 0.20 mm
Jacket standard Black PE ø 27.75 + 0.25 mm M 1474 Z
Options LSOH : IEC 332-3A ø 27.75 + 0.25 mm M 2832 Z
HFR : IEC 332-3A / K26 ø 27.75 + 0.25 mm M 5323 Z / R
Marking : ACOME - HYPERCELL® - COAX HPL 50-7/8 - Flexible - M 1474 - lot : year / week - meter
ACOME - HYPERCELL® - COAX LSOH HPL 50-7/8 - Flexible - M 2832 - lot : year / week - meter
ACOME - HYPERCELL® - COAX LSOH HFR HPL 50-7/8 - Flexible - M 5323 - lot : year / week - meter

Connectors
Mechanical 7-16 male C 0055 A

characteristics Electrical
F l e x i b l e

Cable weight (kg/m) (PE) (LSOH) 0.598 0.650 characteristics 7-16 female C 0002 A
Minimum bending radius (mm) 120 Characteristic impedance (Ω) 50 + 1
Multiple bending radius (mm) 250 Max. frequency (MHz) 5000
Number of bends 20 Relative velocity (%) 87 N male C 0070 A
Tensile strength (N) 1450 Capacitance (pF/m) 76.5 + 1.5 FQ Attenuation R/L Power rating
Peak power Rating (kW) 90 (MHz) (dB/100m) (dB) (kW)
Installation temperature (°C ) - 25 / + 60 30 0.64 - 15.32
Screening effectiveness (dB) >120 N female C 0069 A
Operating temperature (°C ) - 40 / + 85 Inner conductor DC resistance (Ω/km) 1.00 80 1.06 - 9.40
150 1.47 - 6.76
Outer conductor DC resistance (Ω/km) 0.85
450 2.64 - 26.5 3.73
Max. operating voltage (V.RMS) 3000 900 3.88 - 26.5 2.56
Shipping 960 4.02 - 26.5 2.51
EIA 7/8 C 0217 A
Attenuation @ 20°C (dB)
informations Power rating @ 40°C (kW)
1000
1500
4.11
5.18
- 26.5
-
2.41
1.92
and inner conductor @100°C 1700 5.57 - 24.0 1.80 EIA 7/8 right angle C 0218 A
Standard 500 m + 5%
Gross weight (PE) kg 437 // 485* Return Loss max @ 20°C (dB) 1800 5.76 - 24.0 1.73
Net weight (PE // LSOH-HFR) kg 299 // 325 Return Loss typical - 23dB (1@3000 MHz) 2000 6.13 - 24.0 1.63
D 2200 6.47 - 24.0 1.54
2500 6.97 - 23.5 1.42 EIA 1-5/8 C 0085 A
*For sea freight Intermodulation IM3 (1800 MHz) -155 dBc max.
(-163 dBc typical) 2700 7.30 - 23.5 1.36
Reel
B 1.45 3000 7.78 - 1.29
EBE A

EIA Inner 7/8 C 0084 A


D
B
For more detailed information see page 52 - 54 0.70

EIA Inner 1-5/8 C 0088 A


Hangers and hoisting grips
Grounding kits Preparation tools

C 0009 A
C 0200 A C 0314 A
C 0262 A C 0112 A
C 0318 A See page 44-51 for details of accessories
C 0160 A C 0113 A C 0272 S C 0365 A
C 0161 A C 0272 A
22 23
Inner conductor Copper Tube ø
HPL50-1-1/4 F
13.00 + 0.10 mm
Dielectric Cellular PE ø 32.00 + 0.20 mm
Outer Conductor Corrugated copper ø 35.70 + 0.30 mm
Jacket standard Black PE ø 39.50 + 0.50 mm M 2937 Z
Options LSOH : IEC 332-3A ø 39.50 + 0.50 mm M 2938 Z
HFR : IEC 332-3A - K26 ø 39.50 + 0.50 mm M 5358 Z / R
Marking : ACOME - HYPERCELL® - COAX HPL 50-1-1/4 - Flexible - M 2937 - lot : year / week - meter
ACOME - HYPERCELL® - COAX LSOH HPL 50-1-1/4 - Flexible - M 2938 - lot : year / week - meter
ACOME - HYPERCELL® - COAX LSOH HFR HPL 50-1-1/4 - Flexible - M 5358 - lot : year / week - meter

Mechanical Connectors
characteristics Electrical
F l e x i b l e

Cable weight (kg/m) (PE) (LSOH) 0.940 1.070 characteristics 7-16 male C 0049 C
Minimum bending radius (mm) 200 Characteristic impedance (Ω) 50 + 1
Multiple bending radius (mm) 380 Max. frequency (MHz) 3000
Number of bends 20 Relative velocity (%) 87 7-16 female C 0003 C
Tensile strength (N) 2500 Capacitance (pF/m) 76.5 + 1.5 FQ Attenuation R/L Power rating
Peak power Rating (kW) 181 (MHz) (dB/100m) (dB) (kW)
Installation temperature (°C ) - 25 / + 60 30 0.45 - 23.14
Screening effectiveness (dB) >120 N male C 0058 C
Operating temperature (°C ) - 40 / + 85 Inner conductor DC resistance (Ω/km) 0.76 80 0.75 - 13.85
150 1.04 - 9.88
Outer conductor DC resistance (Ω/km) 0.60
450 1.87 - 26.5 5.48
Max. operating voltage (V.RMS) 4300 900 2.78 - 26.5 3.71 N female C 0057 C
Shipping 960 2.88 - 26.5 3.59
Attenuation @ 20°C (dB) 1000 2.96 - 26.5 3.49
informations Power rating @ 40°C (kW) 1500 3.75 - 2.75
and inner conductor @100°C 1700 4.04 - 24.0 2.55 EIA 7/8 C 0219 C
Standard 500 m + 5%
Gross weight (PE) kg 828 // 970* Return Loss max @ 20°C (dB) 1800 4.18 - 24.0 2.47
Net weight (PE // LSOH-HFR) kg 470 // 535 Return Loss typical - 23dB (1@3000 MHz) 2000 4.45 - 24.0 2.31
2200 4.70 - 24.0 2.17
D
2500 5.05 - 23.5 2.00 EIA 1-5/8 C 0086 C
*For sea freight Intermodulation IM3 (1800 MHz) -155 dBc max.
(-163 dBc typical) . . 2700 5.37 - 23.5 1.91
Reel
GBE B
1.98
3000 5.70 - 1.78
A

Inner 7/8 C 0084 A


D
B
For more detailed information see page 52 - 54 1.08

Inner 1-5/8 C 0088 A

Hangers and hoisting grips Preparation tools


Grounding kits
C 0010 A
C 0202 A C 0352 A
C 0317 A C 0315 A
C 0263 A C 0115 A See page 44-51 for details of accessories
C 0163 A C 0116 A C 0273 S
C 0164 A C 0273 A
24 25
Inner conductor Corrugated copper tube ø
HPL50-1-5/8 F
17.30 + 0.20 mm
Dielectric Cellular PE ø 42.00 + 0.20 mm
Outer Conductor Corrugated copper ø 46.20 + 0.30 mm
Jacket standard Black PE ø 50.00 + 0.50 mm M 2939 Z
Options LSOH : IEC 332-3A ø 50.00 + 0.50 mm M 2940 Z
HFR : IEC 332-3A - K26 ø 50.00 + 0.50 mm M 5359 Z / R
Marking : ACOME - HYPERCELL® - COAX HPL 50-1-5/8 - Flexible - M 2939 - lot : year / week - meter
ACOME - HYPERCELL® - COAX LSOH HPL 50-1-5/8 - Flexible - M 2940 - lot : year / week - meter
ACOME - HYPERCELL® - COAX LSOH HFR HPL 50-1-5/8 - Flexible - M 5359 - lot : year / week - meter

Mechanical Connectors
characteristics Electrical
F l e x i b l e

Cable weight (kg/m) (PE) (LSOH) 1.448


Minimum bending radius (mm) 300
1.600
characteristics 7-16 male C 0054 C

Characteristic impedance (Ω) 50 + 1


Multiple bending radius (mm) 500 Max. frequency (MHz) 2500
Number of bends 20 7-16 female C 0004 C
Relative velocity (%) 87
Tensile strength (N) 2400 Capacitance (pF/m) 77.5 + 1.5 FQ Attenuation R/L Power rating
Peak power Rating (kW) 306 (MHz) (dB/100m) (dB) (kW)
Installation temperature (°C ) - 25 / + 60
Screening effectiveness (dB) >120 30 0.35 - 29.64 N male C 0068 C
Operating temperature (°C ) - 40 / + 85 80 0.59 - 17.60
Inner conductor DC resistance (Ω/km) 0.70
150 0.84 - 12.60
Outer conductor DC resistance (Ω/km) 0.40
450 1.55 -26.5 6.85
Max. operating voltage (V.RMS) 5400
Shipping 900
960
2.32
2.41
- 26.5
- 26.5
4.58
4.36
N female C 0067 C

informations Attenuation @ 20°C (dB)


Power rating @ 40°C (kW)
1000
1500
2.47
3.17
- 26.5
-
4.30
3.36
Standard 500 m + 5% and inner conductor @100°C 1700 3.43 - 24.0 3.10 EIA 7/8 C 0220 C
Gross weight (PE) kg 1226 // 1391* Return Loss max @ 20°C (dB) 1800 3.56 - 24.0 3.00
Net weight (PE // LSOH-HFR) kg 724 // 800 Return Loss typical - 23dB (1@3000 MHz) 2000 3.80 - 24.0 2.81
2200 4.04 - 24.0 2.63 EIA 1 5/8 C 0087 C
*For sea freight Intermodulation IM3 (1800 MHz) -155 dBc max. 2500 4.39 - 2.42
Reel (-163 dBc typical) 2700 - - -
B 2.28 3000 - - -
HBE A

Inner 7/8 C 0084 A


D
B
For more detailed information see page 52 - 54 1.14

Inner 1-5/8 C 0088 A

Hangers and hoisting grips


Grounding kits Preparation tools
C 0203 A
C 0011 A
C 0321 A
C 0353 A
(open with lace) C 0316 A
C 0264 C C 0118 A C 0274 S
C 0317 A C 0119 A C 0274 A See page 44-51 for details of accessories
C 0166 A C 0167 A
26 27