APPLICATION GUIDE
Switch
Thank you for choosing Schneider Electric AvatarOn series products.
To ensure proper application of our product, please read through the following
information before installation and use.
This application guide applies to the following products.
(Notes: suffix WE/WG/GH/LW/WD/ST_C1/G12 etc. mean the colors and sales
areas)
Cat. No. Description
E83FLW_PIR Night Foot Lamp w PIR sensor LED
SPECIFICATIONS
Rated input : 220-240V~,50/60Hz
Rated power : 0.7-0.8W
Input current : 20mA Max.
Light source power : 0.12W(4xMax 0.03W/pcs)
Power factor : <0.2
Mounting center : 60.3mm
Delay time : 60-90s (During this Period can be
JYT8788501 V00
triggered continuously)
Warm-up brightness :5-20Lux
Operating temperature :35℃ Max
Sensing distance :8m Max
IMPORTANT NOTE
1. The products must be installed by qualified electricians.
2. Please check your local wiring regulations before installation.
3. Please install with standard wall box to aid correct operation of the product.
4. Safekeeping the surround to prevent damage during product installation.
5. Turn off the power supply when you clean the product. Use a piece of soft,
slightly-moistened cloth or tissue paper to wipe off the dust and dirt on the surface.
Clean with much diluted detergent if necessary but avoid using corrosive chemicals.
6. This product is only suitable for indoor environment.
7. The sensitivity of the product varies according to the direction in which people
move, as shown in Figure 1 and Figure 2 .
8. The product will automatically light up when it is powered on for the first time and
enter standby state after it is turned off .
9. This product contains a non-user replaceable light source. The light source in this
luminaire shall be supplied by the manufacturer or to be replaced by an service agent
or a competent person.
High trigger Low trigger
sensitivity sensitivity
Figure 1 Figure 2
WIRING DIAGRAMS
L N
Live
Neutral
MOUNTING INSTRUCTION
1. Remove the cover
2. Unscrew the protective 3. Connect the wires correctly according to
cover and open the cover. the wiring diagram and arrange the wires.
4. Make sure the protective cover 5. Fix the grid plate on to the wall box
snaps and locks with screws. with mounting screw and reattach the
dolly cover.