- All winfiol commands have 05 digits ends by:
P ---------- PRINT
I ---------- INITIATE
C ---------- CHANGE
E ---------- EXECUTE
COMMAND DEFINITIONS
DTSTP: DIP=ALL; DIGITAL PATH STATE
RLCRP: CELL=ALL; Cell resource data
RLSTP: CELL=ALL; Cell Status
CACLP; System clock
RLSLP:CELL=ALL; Cell supervision of logical channels
ALLIP:ACL=A2; Alarm for BTSs
RXASP:MOTY=RXOTG; Managed BTS alarm situations
RXASP:MO=RXOTG-30; Managed BTS alarm situations TG=30
RXELP:MO=RXOTX-0-0; FAULT INFORMATION LOG
RES RESET
STA STARTED
DIS DISABLED
ENA ENABLED
RXMFP:MOTY=RXOTX MANAGED OBJECT FAULT INFORMATION
RXMSP:MOTY=RXOTG; MANAGED OBJECT STATUS (BTS)
BLOCKED
DTFSP:DIP=ALL; DIGITAL PATH FAULT SUPERVISION
PARAMETERS
DTQSP:DIP=ALL; DIGITAL PATH QUALITY SUPERVISION
PARAMETERS
RLBCP:CELL=ALL; DYNAMIC BTS POWER CONTROL CELL
DATA
RLPCP:CELL=ALL; DYNAMIC MS POWER CONTROL CELL
DATA
RXTCP:MOTY=RXOTG,CELL=10621A; To Get TG
RXTCP:MO=RXOTG-14; To get how many sector
RXCDP:MO=RXOTG-20; MANAGED OBJECT CONFIGURATION DATA
TRX
RXMOP:MO=RXOTRX-350-0&-1&-3; Where is TRU located which cell (A, B ,C)
RLCFP:CELL=10102A; CELL CONFIGURATION FREQUENCY DATA
RLDEP:CELL=10622B; CELL DESCRIPTION DATA
NTCOP:SNT=ETM2-0; SWITCHING NETWORK TERMINAL
CONNECTION DATA
RXMOP:MO=RXOTG-17; To get by TG site name
RXMOP:MO=RXOCF-17; Check the site Master/Slave
ALLIP:ALCAT=POWER;
ALLIP:ALCAT=EXT;
ALLIP:ALCAT=APZ;
ALLIP:ALCAT=APT;
NTCOP:SNT=ALL; SWITCHING NETWORK TERMINAL
CONNECTION DATA
RXMFP:MO=RXOTG-408,FAULTY,SUBORD; All active faults (class 1) in TG
RLVLP; CELL SEIZURE SUPERVISION OF LOGICAL
CHANNELS DATA
RLSLP:CELL=ALL; CELL SUPERVISION OF LOGICAL CHANNEL
AVAILABILITY DATA
ALLIP:PRCA=43; ALARM LIST (BTS EXTERNAL FAULT)
RLSBP:CELL=10201A; CELL SYSTEM INFORMATION BCCH DATA
C7LDp:ls=ALL; SIGNALLING CC7
C7LTp:ls=ALL;
RXAPP:MO=RXOTG CHECK E1 DEVICES “31”
RXCAP:MO=RXOTG CHECK CASCADED OR NOT
RXCAP:MO=RXOTG
<racip:dev=RTLTB2-88;
DEVICE AND CIRCUIT IDENTITY CODE DATA
DEV BSC CIC ATERCIC
RTLTB2-88 824
END
RLGSP:CELL=10626A;
RLGSP:CELL=ALL;