INTRODUCTION OF WIRE CONTROLLER
Constitution of Wire panel
■ Par ts of the panel are as follow
1) One wire controller DM602A
2) One electric control panel: LY516A or LY517A
3) Temperature probes(The number is depended on the actual order)
4) Others(No)
■ Connection wires specification of Control panels:
1) HT381 Conector cable: Solid cable diameter(0.08-1.5mm 2),specification(28 - 16AWG),Length of
   stripped wire(7mm) , fixing screw(M2.0),screw torque( 0.2-0.25NM)
2) HT508 Conector cable: Solid cable diameter(0.20-2.5mm 2),specification(24 - 12AWG),Length of
  stripped wire( 7mm), fixing screw(M2.5),screw torque(0.4-0. 50NM)
  Product marking
    Don't tear up the silver lable affixed to the front or back of the controller , for it will be helpful
for check .
For example:
Product code:H.DM602A.001
Product serial number:OW041622- 090402-0251420
Function code of Delivery software:X1.DM602A.TY.F01C
Version number of Delivery software(Unit code): V200A0( I.DM602A.001)
  Monitor introduction
■ DM602A Monitor installation and its dimension: unit mm
              119.05
                                                  21.5
                                                                                Φ4     Φ4
                                 119.05
                                                                               Φ5
                                                    .7.
                                                                                                                            LED: ● Yellow light turns on: Normal standby
■ Panel Introduction                                                                                                                 ● Green light flashes: starting operation
                                                                                                                                    ( standby →operating)
                                                                                                                                     ● Green light turns on: Normal operating
                                                                                                                                    ● Red light flashes: stopping operation
                                                                                                                                         ( operating →standby)
                                                                                                                                     ● Red light turns on: serious break- down
  ● The number 0~7 can be used for
  password setting , while the number 8 and
  9 will be replaced by 0 and 1 separately                                                                                            ON/OFF button:It will carry on STOP
  ● ON/OFF button, RESET button and SET                                                                                               operation if it is pressed during anti-
  buttons a re not set with the corresponding                                                                                         freezing operation.
  number.
                                                                                                                                      Display screen
                                                                                                                                      6_ CHECK button: For fault check
                                                                                                                                      7_ MODEL button:
                                                                                                                                      ● It is used for module switching on the
                                                                                                                                      check interface;
     0_ TIME button: For setting the time;                                 TIMER                    MODE    CHECK
                                                                                                                                      ● It is used for switching current setting
                                                                                                                                      position on the setting interface;
1_ TIMER button:For setting the timing time;                                TIME        T
                                                                                                   WATER
                                                                                                   LEVEL
                                                                                                            MODULE
                                                                                   SE
                                                                                                                                      RESET button:
 SET button:                                                                                                                          ● The sound will be eliminated by pressing the
                                                                                                                      ET              button when the system gives a fault alarm;
 ● Affirm the modification;                                                                                  RE
                                                                                                                  S
 ● Enter to the temperature setting interface by                                                                                      ● The fault will be reset by pressing the key
 pressing it on the main interface;                                                                                                   for noalarming case.
                                                                                                                                      ● The modification can not be saved by
                                                                                                                                      pressingit for returning operation
                                          2_   ADD button:
                                          ●    For turning to the front page;                              4_ MODE button:It is used for setting unit modes;
                                          ●    For increasing the parameter value;                         5_ WATER LEVEL button: It is used for setting the water level;
                                          3_   SUB button:
                                          ●    For turning to the next page;
                                          ●    For reducing the parameter value;
1. Long keys and key combination(Press down both keys at the same time)
1)                :All keys will be locked/unlocked;
                             T
2)   SE
          T
              +    RE
                        SE
                                 :Preheating operation will be cancelled;
3) Press down and hold                          TIMER        for 3s: Timing function will be set;
4)   SE
          T
              +    MODULE
                                 :The current module will carry on forced-defrost operation ;
5)Press down and hold                            SE
                                                         T
                                                             and   CHECK
                                                                           for 3s:The system will enter to the interface for factory setting;
6)   SE
          T
              +     CHECK
                                 : The system will enter to the interface for maintenance setting;
7)Press down and hold                           SE
                                                     T       for 3s:The system will enter to the interface for project setting;
8)Press down and hold                          CHECK         for 3s:The system will enter to the interface for monitor setting;
2. Display section:
1) Operating modes:
                                                                                                                           Heat                            Hot water
                  AUTO                    COOL                             HEAT               FAN                          recovery
2) Operating states of the unit:
                  HUMI                     DRY                             ANTI-FR                FAULT                          Module                       SWING
                                                                                                                                 number
                                                                                            .13.
                                                                                            .8.
3) Operating states of equipment:
         Water                Wind                 Indicating the                   Sleeping          Timing
         level                speed                compressor running
          When it turns on,it means defrosting function.
          Number
          When it turns on,it means that the corresponding compressor is defrosting;
          When it flashes, it means the forced-defrost order is received.
           When it turns on,it means that the electric heating is operating;
           When it flashes, it means the unit is carrying on preheating operation
4) Buttons state:
             Buttons locked           Invalid button
  Interface display and its operation instruction
■ User operation instruction
  Before boot-strap, please check whether all wire connections are OK.
1. Summary:
Electrifying→Boot-strap interface → Operation main interface
                                                                        →State check                →Monitor setting
                                                                        →Fault check                →Project setting
                                                                        →Temp. / Mode check         →Maintenance setting
                                                                        →Time setting               →Factory setting
                                                                        →Timing setting
2. Boot -strap interface :
①
                                                                     The boot screen displays the software function codes
                                                                     and vision No.of DM602A within the first five
                                                                     seconds.
                                 Countdown                           F01: Function code(such as DM602A.TY.F01C)
                                                                     V200: Vision NO.(such as V200),displaying 3s and
                                                                     A0, displaying 2s;
 ②                                                                 The boot screen displays the software function codes
                                                                   and vision No.of DM602A within the latter five
                                                                   seconds.
                                                                   B01: Function code(such as LY514A.TY.B01C)
                              Countdown                            V200: Vision NO.(such as V200),displaying 3s and
                                                                   A0, displaying 2s;
Remarks:The function codes and vision No. Above are just fore reference.
                                                               .9.
3. Main operation interface
   Press RESET key or countdown, the system will enter to the main operation interface:
                                                         The preheating operation will be started after electrifying as if the preheating time is not zero.
                                                         During preheating operation, the unit can not be started until the operation is over.
                                                         If    flashes, it means preheating operation andthe operation can be cancelled by pressing
                                                         down at the same time;
                                                         If    turns on, it means that the auxiliary electric heating is effective and can be started.
            means all buttons on the panel are locked;
            means the button is invalid.
  Press                   and   simultaneously to switch
  LOCK/ UNLOCK operation
            Means defrost state of             modules
   SE
        T
             +   MODULE
                          :The current module will
                                                                            means timing operation and it will be started or shut down by pressing    TIMER   .
 carry on forced-defrost operation.
 System module and status                                                        means module code and 00 is the default value and the number will
                                                                                 change by pressing  .   MODULE
                                                                              Flashes for fault display and the system will enter to the fault check interface
Equipment states: No. 1 Compressor runs
                  No. 1 Compressor is defrosting                              by pressing     .
                                                                                          CHECK
                  No. 1 Electric heater runs                                 The heat recovery temperature is indicated only when the heat recovery
                                                                             function is started up
                                                                             The system inlet water temperature or outlet water temperature is
                                                                             indicated for I . T setting or O . T setting .
                                                                             If    icon is indicated, it means sensor fault or the measuring value is out
                                                                             of the setting value .
4. State check
                                        Operation main interface                                  State check interface       State code :
                                                                                                                              T0xx : System state
Module No .: 00 ~ 15
                                                                                                                              Tnxx : No . n compressor
SRI addresses : 0 ~ F
                                                                                                                              state (n = 1 , 2 , 3 , 4 )
                                                                                                                              T9xx : The current module
                                                                                                                               state
                                        State of No.00 module                                     xx % means the opening of
                                                                   MODULE
                                                                                                  electric expansion valve
                                                                                                                              Press    or    to switch the
The switch of module
                                                                                                                              check of T0xx , Tnxx and T9xx
No . Is in the range
of setting value
                                        State of No. 01 module                                      XxA means the
                                                                   MODULE
                                                                                                    compressor current
                                                                                                                              ● Press     to return to the main
                                                                                                                                       RESET
 FF means system
                                                                                                                              interface
   information
                                                                                                                              ● If no button is pressed within
                                                                                                                              180s , the system will return to
                                        FF without any information                                                            the main interface automatically .
                                                                                      .10.
5. Fault check
  Operation main interface
                                                                                                                                                              Press    or    to switch the
                                                                                                                                                              check of T0xx , Tnxx and T9xx
                                           4 numbers for fault code                DU
                                                                                        LE
                                                                           MO                                                           T
  Module No . : 00 ~ 15                                                                                              ●Press   REto return to the main
                                                                                                                                   SE
  SRI addresses : 0 ~ F                                                                                              interface
  The interface displays the                                                                                         ●If no button is pressed within
  No . xx module fault                                                                                               180s , the system will return to
                                                                                                                     the main interface automatically .
   The switch of module No . is
                                               - - - - Means no fault                   LE
   in the range of setting value                                           M
                                                                               O
                                                                                   DU
    FF means system information
                                               4 numbers for fault code
6. TEMP./MODE setting
                                     T . SET . Means setting temperature
                                     and it means the current temperature
        Operation main interface
                                     when flashing .
                                                                                                                                                             RE
                                                                                                                                                                  SE
                                                                                                                                                                          T
                                                                                                                                                                                   Cancel setting
TEMP.                                 SE
                                           T
                                                                                                                                                                                                    Return to the
                                                                                                  Modify setting 1                                                                 Save setting
                                                                                                                                                              SE
                                                                                                                                                                          T
                                                                                                                                                                                                    main interface
             Setting 1 Setting 2
                                                                                             LE
                                                                                        DU
                                                                                   MO
                                                  It is effective only if
  ●If no button is pressed within
                                                  the setting 0 is set .
  180s , the system will return to
  the main interface automatically .                                                                                                                          RE
                                                                                                                                                                          SE
                                                                                                                                                                               T
                                                                                                                                                                                   Cancel setting
                                                                                                                                                                                                    Return to the
                                                                                                  Modify setting 2                                                        T
                                                                                                                                                              SE
                                                                                                                                                                                   Save setting main interface
        Operation main interface
                                                                                                                                                                              T
                                                                                                       MODE
                                                                                                                                                             RE
                                                                                                                                                                      SE
                                                                                                                                                                                   Cancel setting
MODE                                 MODE                                                                                                                                                           Return to the
                                                                                                  Modify modes                                                SE
                                                                                                                                                                      T
                                                                                                                                                                                   Save setting main interface
                                                 It means the current code                                              ●If no button is pressed within
                                                 when flashing                                                          180s , the system will return to
                                                                                                                        the main interface automatically .
7. Current time setting
                           Time                                                                                                     TIME
  Operation main interface
                                      TIME                      TIME                                          TIME                              TIME                                         TIME
                                   Switch to                Switch to                                  Switch to                            Switch to                                    Switch to
                                   minute setting           hour setting                               year setting                         month setting                                day setting
                                                                                                                                                                          T
                                                                                                                              or                             RE
                                                                                                                                                                  SE
                                                                                                                                                                                  Cancel setting
                                                     ●If no button is pressed within                                                            Finish                                              Return to the
                                                     180s , the system will return to                                                         modification   SE
                                                                                                                                                                  T
                                                                                                                                                                                   Save setting main interface
                                                                                                                        Modify setting
                                                     the main interface automatically .
                                                                                         .11.
8. Timing time setting
                                        The day of the week that                                 No . N timing setting works
                                        No . N timing setting                                    No . N timing setting is out of work
                                        works on                                        No . N timing setting time
                                                                                                                            No . N timing setting time will be cleared
                                                                                                                            by pressing down        and holding it for 3s .
                                                                                                                                                                  SE
                                                                                                                                                                       T
                                                         There are 10 timing settings ( 00 ~ 10 )
                                                         and No . N timing setting works
Remarks:
  There are 10 timing settings(00~10), each setting can be set separately at the any time and it is
noneffective if the time is setfor 00:00 or in the time from Saturday to Sunday.
  The settings don't change for starting or shutting down timing operation.
              Operation main interface                                                                                                                                                        When SUN or SAT flashes,
                                                                                                                                                                                              0 is for effective timing and
                                                                                                                                                                                              1 is for noneffective timing
                                                                                                                                                      The timing setting will be switched
                                                                                                                                                      in turn from Saturday to Sunday and
          T
RE
     SE       TIMER                                                                                                                                   one day is flashed once .
                                                                                                            TIMER                                        TIMER
                                                        TIMER                                                                                                                                   TIMER
                                                                                                         Switch to                                                                          Switch to
                                                        Switch to                                                                                      Switch to                            week setting
                                                                                                         hour setting
                                                        minute setting                                                                                ON/OFF setting
                                                                                                                                                                                                                           Modification effective/noneffective
                or
                                                                                                                                                                                                                      or
                                                                                                                                                                 or        Modify setting
                                                                                            ES
                                                                                               E   T
                                                                                                       Cancel setting
                                                                                        R
                                                                                                                          Finish No.N
                                                                                        SE
                                                                                             T
                                                                                                       Save setting       timing setting
9. Parameter setting
              Please press    to enter the parameter setting interface after inputing the password and keep the
                                SET
              password right!
              Operation main interface                                                                                                                       Parameter setting interface
                                      Press     and
                                               SE
                                                    T           CH EC K
                                      simultaneously for 3s                                                             Input the password
                                      Enter to the password                                                             Enter to the password
                                      input interface                                                                   setting interface by
                                                                                                                        pressing             SE
                                                                                                                                                  T
● Parameter initializing : Please follow the steps below to carry on parameter initializing operation
                                      Press    SE
                                                    T
                                                         and hold it                                                    Press or to                                                            Press   to return to the
                                                                                                                                                                                                        RE
                                                                                                                                                                                                             SE
                                                                                                                                                                                                                  T
                                      for 3s                                                                            switch setting items                                                   parameter interface.
                                                                                                                        Press  SE  to carry
                                                                                                                                    T
                                      Enter to the initializing                                                         on initializing
                                      interface                                                                         Press  RE  to exit the
                                                                                                                                    SE
                                                                                                                                         T
                                                                                                                        interface.                                              Initializing Succ!
                                                                          Initializing items:                                                                                   Fail to Initializing!
                                                                          00: Factory parameter initialization
                                                                          01: Total running time initialization
                                                                          02: User's password initialization
                                                                                                                .12.