INTRODUCTION OF WIRE CONTROLLER
Constitution of Wire panel
■ Par ts of the panel are as follow
1) One wire controller DM602A
2) One electric control panel: LY516A or LY517A
3) Temperature probes(The number is depended on the actual order)
4) Others(No)
■ Connection wires specification of Control panels:
1) HT381 Conector cable: Solid cable diameter(0.08-1.5mm 2),specification(28 - 16AWG),Length of
stripped wire(7mm) , fixing screw(M2.0),screw torque( 0.2-0.25NM)
2) HT508 Conector cable: Solid cable diameter(0.20-2.5mm 2),specification(24 - 12AWG),Length of
stripped wire( 7mm), fixing screw(M2.5),screw torque(0.4-0. 50NM)
Product marking
Don't tear up the silver lable affixed to the front or back of the controller , for it will be helpful
for check .
For example:
Product code:H.DM602A.001
Product serial number:OW041622- 090402-0251420
Function code of Delivery software:X1.DM602A.TY.F01C
Version number of Delivery software(Unit code): V200A0( I.DM602A.001)
Monitor introduction
■ DM602A Monitor installation and its dimension: unit mm
119.05
21.5
Φ4 Φ4
119.05
Φ5
.7.
LED: ● Yellow light turns on: Normal standby
■ Panel Introduction ● Green light flashes: starting operation
( standby →operating)
● Green light turns on: Normal operating
● Red light flashes: stopping operation
( operating →standby)
● Red light turns on: serious break- down
● The number 0~7 can be used for
password setting , while the number 8 and
9 will be replaced by 0 and 1 separately ON/OFF button:It will carry on STOP
● ON/OFF button, RESET button and SET operation if it is pressed during anti-
buttons a re not set with the corresponding freezing operation.
number.
Display screen
6_ CHECK button: For fault check
7_ MODEL button:
● It is used for module switching on the
check interface;
0_ TIME button: For setting the time; TIMER MODE CHECK
● It is used for switching current setting
position on the setting interface;
1_ TIMER button:For setting the timing time; TIME T
WATER
LEVEL
MODULE
SE
RESET button:
SET button: ● The sound will be eliminated by pressing the
ET button when the system gives a fault alarm;
● Affirm the modification; RE
S
● Enter to the temperature setting interface by ● The fault will be reset by pressing the key
pressing it on the main interface; for noalarming case.
● The modification can not be saved by
pressingit for returning operation
2_ ADD button:
● For turning to the front page; 4_ MODE button:It is used for setting unit modes;
● For increasing the parameter value; 5_ WATER LEVEL button: It is used for setting the water level;
3_ SUB button:
● For turning to the next page;
● For reducing the parameter value;
1. Long keys and key combination(Press down both keys at the same time)
1) :All keys will be locked/unlocked;
T
2) SE
T
+ RE
SE
:Preheating operation will be cancelled;
3) Press down and hold TIMER for 3s: Timing function will be set;
4) SE
T
+ MODULE
:The current module will carry on forced-defrost operation ;
5)Press down and hold SE
T
and CHECK
for 3s:The system will enter to the interface for factory setting;
6) SE
T
+ CHECK
: The system will enter to the interface for maintenance setting;
7)Press down and hold SE
T for 3s:The system will enter to the interface for project setting;
8)Press down and hold CHECK for 3s:The system will enter to the interface for monitor setting;
2. Display section:
1) Operating modes:
Heat Hot water
AUTO COOL HEAT FAN recovery
2) Operating states of the unit:
HUMI DRY ANTI-FR FAULT Module SWING
number
.13.
.8.
3) Operating states of equipment:
Water Wind Indicating the Sleeping Timing
level speed compressor running
When it turns on,it means defrosting function.
Number
When it turns on,it means that the corresponding compressor is defrosting;
When it flashes, it means the forced-defrost order is received.
When it turns on,it means that the electric heating is operating;
When it flashes, it means the unit is carrying on preheating operation
4) Buttons state:
Buttons locked Invalid button
Interface display and its operation instruction
■ User operation instruction
Before boot-strap, please check whether all wire connections are OK.
1. Summary:
Electrifying→Boot-strap interface → Operation main interface
→State check →Monitor setting
→Fault check →Project setting
→Temp. / Mode check →Maintenance setting
→Time setting →Factory setting
→Timing setting
2. Boot -strap interface :
①
The boot screen displays the software function codes
and vision No.of DM602A within the first five
seconds.
Countdown F01: Function code(such as DM602A.TY.F01C)
V200: Vision NO.(such as V200),displaying 3s and
A0, displaying 2s;
② The boot screen displays the software function codes
and vision No.of DM602A within the latter five
seconds.
B01: Function code(such as LY514A.TY.B01C)
Countdown V200: Vision NO.(such as V200),displaying 3s and
A0, displaying 2s;
Remarks:The function codes and vision No. Above are just fore reference.
.9.
3. Main operation interface
Press RESET key or countdown, the system will enter to the main operation interface:
The preheating operation will be started after electrifying as if the preheating time is not zero.
During preheating operation, the unit can not be started until the operation is over.
If flashes, it means preheating operation andthe operation can be cancelled by pressing
down at the same time;
If turns on, it means that the auxiliary electric heating is effective and can be started.
means all buttons on the panel are locked;
means the button is invalid.
Press and simultaneously to switch
LOCK/ UNLOCK operation
Means defrost state of modules
SE
T
+ MODULE
:The current module will
means timing operation and it will be started or shut down by pressing TIMER .
carry on forced-defrost operation.
System module and status means module code and 00 is the default value and the number will
change by pressing . MODULE
Flashes for fault display and the system will enter to the fault check interface
Equipment states: No. 1 Compressor runs
No. 1 Compressor is defrosting by pressing .
CHECK
No. 1 Electric heater runs The heat recovery temperature is indicated only when the heat recovery
function is started up
The system inlet water temperature or outlet water temperature is
indicated for I . T setting or O . T setting .
If icon is indicated, it means sensor fault or the measuring value is out
of the setting value .
4. State check
Operation main interface State check interface State code :
T0xx : System state
Module No .: 00 ~ 15
Tnxx : No . n compressor
SRI addresses : 0 ~ F
state (n = 1 , 2 , 3 , 4 )
T9xx : The current module
state
State of No.00 module xx % means the opening of
MODULE
electric expansion valve
Press or to switch the
The switch of module
check of T0xx , Tnxx and T9xx
No . Is in the range
of setting value
State of No. 01 module XxA means the
MODULE
compressor current
● Press to return to the main
RESET
FF means system
interface
information
● If no button is pressed within
180s , the system will return to
FF without any information the main interface automatically .
.10.
5. Fault check
Operation main interface
Press or to switch the
check of T0xx , Tnxx and T9xx
4 numbers for fault code DU
LE
MO T
Module No . : 00 ~ 15 ●Press REto return to the main
SE
SRI addresses : 0 ~ F interface
The interface displays the ●If no button is pressed within
No . xx module fault 180s , the system will return to
the main interface automatically .
The switch of module No . is
- - - - Means no fault LE
in the range of setting value M
O
DU
FF means system information
4 numbers for fault code
6. TEMP./MODE setting
T . SET . Means setting temperature
and it means the current temperature
Operation main interface
when flashing .
RE
SE
T
Cancel setting
TEMP. SE
T
Return to the
Modify setting 1 Save setting
SE
T
main interface
Setting 1 Setting 2
LE
DU
MO
It is effective only if
●If no button is pressed within
the setting 0 is set .
180s , the system will return to
the main interface automatically . RE
SE
T
Cancel setting
Return to the
Modify setting 2 T
SE
Save setting main interface
Operation main interface
T
MODE
RE
SE
Cancel setting
MODE MODE Return to the
Modify modes SE
T
Save setting main interface
It means the current code ●If no button is pressed within
when flashing 180s , the system will return to
the main interface automatically .
7. Current time setting
Time TIME
Operation main interface
TIME TIME TIME TIME TIME
Switch to Switch to Switch to Switch to Switch to
minute setting hour setting year setting month setting day setting
T
or RE
SE
Cancel setting
●If no button is pressed within Finish Return to the
180s , the system will return to modification SE
T
Save setting main interface
Modify setting
the main interface automatically .
.11.
8. Timing time setting
The day of the week that No . N timing setting works
No . N timing setting No . N timing setting is out of work
works on No . N timing setting time
No . N timing setting time will be cleared
by pressing down and holding it for 3s .
SE
T
There are 10 timing settings ( 00 ~ 10 )
and No . N timing setting works
Remarks:
There are 10 timing settings(00~10), each setting can be set separately at the any time and it is
noneffective if the time is setfor 00:00 or in the time from Saturday to Sunday.
The settings don't change for starting or shutting down timing operation.
Operation main interface When SUN or SAT flashes,
0 is for effective timing and
1 is for noneffective timing
The timing setting will be switched
in turn from Saturday to Sunday and
T
RE
SE TIMER one day is flashed once .
TIMER TIMER
TIMER TIMER
Switch to Switch to
Switch to Switch to week setting
hour setting
minute setting ON/OFF setting
Modification effective/noneffective
or
or
or Modify setting
ES
E T
Cancel setting
R
Finish No.N
SE
T
Save setting timing setting
9. Parameter setting
Please press to enter the parameter setting interface after inputing the password and keep the
SET
password right!
Operation main interface Parameter setting interface
Press and
SE
T CH EC K
simultaneously for 3s Input the password
Enter to the password Enter to the password
input interface setting interface by
pressing SE
T
● Parameter initializing : Please follow the steps below to carry on parameter initializing operation
Press SE
T
and hold it Press or to Press to return to the
RE
SE
T
for 3s switch setting items parameter interface.
Press SE to carry
T
Enter to the initializing on initializing
interface Press RE to exit the
SE
T
interface. Initializing Succ!
Initializing items: Fail to Initializing!
00: Factory parameter initialization
01: Total running time initialization
02: User's password initialization
.12.