G.
RAMAMOORTHI CONSTRUCTIONS (I) PVT LTD
BROADWAY CHECKLIST - SUNKEN FILLING(AAC BLOCK) Date:
MEGAAPLEX (Mix ratio - 1:5) Location
Drawing no & Date
Status
S.No Description Remarks
Yes No NA
Before Sunken Filling:
Check for CLEANING OF BASE SURFACE. Is loose
1
mortar & debris removed from the work area?
Check for Slab area cracks if any visible at top
2
surface?
3 Check for reference level and Sunken filling top
level?
4 Check for floor slope as per drawing
5 Check for final approval of clients?
During sunken filling:
1 Check for avilability of materials & man power
Check for moist and cement slurry should be
2
applied top surface area?
Check for sunken filling(AAC Block-50mm tk) mixing
3
ratio 1:5 (one cement and five parts of m sand )
Ensure 10mm thickness of mortar at block bottom
4
area & horizontal joints packing
Check for sunken filling top level & floor level,Trap
5
location
After sunken filling :
1 Check for sunken filling curing
Checked Approved
Name Name
Site Engineer/ Project Engg(GRC) Client Engineer /Project Head (FABS)
Signature Signature