POWERTEC Generator Set
Powered by Perkins 4016TAG2A Engine
Model:PPE2250             Prime Power: 1600KW/2000KVA             Standby Power: 1800KW/2250KVA
  Genset Fundamental Characteristics                                  Genset Standard Configuration
 ◆ 230/400VAC,50HZ 0.8PF 3 Phases, 4 wires output                ◆ Perkins Engine
 ◆ Frequency drop            ≤3%                                 ◆ Brushless synchronous alternator
 ◆ Voltage modulation         ≤0.3%                              ◆ POWERTEC intelligent controller
 ◆ The steady state frequency       ≤0.5%                        ◆ 40℃ standard ambient temperature
 ◆ The steady state voltage deviation ≤±1%                            Water radiator
 ◆ The transient frequency deviation     ≤+10% ≤-15%             ◆ Modularized case circuit breaker(3P)
 ◆ The transient voltage deviation ≤+20%         ≤-15%           ◆ Float Battery Charger
 ◆ Frequency recovery time       ≤3S                             ◆ Battery connect wire
 ◆ Voltage recovery time      ≤1S(Voltage±3%)                    ◆ Steel base frame(include shock absorbers )
 ◆ THF (Telephone Harmonic Factor)        <3                     ◆ Bellows、exhaust bend
 ◆ TIF (Telephone Influence Factor) <50                          ◆ Manual book and files
    Comply to Standard NEMA MG1-22.43
 ◆ Standard equipped with ambient temperature 40℃
    Connecting radiator
 ◆ Inbuilt shock absorber has high performance on shock absorption.
    It’s easy to be transported and installed without embedding and
    Fixing rubber shock pad between the genset and ground
  Genset Optional Configuration
 ◆ 24V Starter Batteries
 ◆ Daily Fuel Tank
 ◆ Oil-water separator
 ◆ Warning function of low water level, low fuel oil
 ◆ Automatically monitoring & controlling system of
    City power
 ◆ Coolant heater
 ◆ Oil heater
 ◆ Heat exchanger--Water cooling Tower System
 ◆ Soundproof Canopy/ Trailer
 ◆ ISO container
 ◆ Design and construction of environmental protection
    Engineering for the Genset room
                                                         1
 Equipment Instruction
 Performance Description of Diesel Engine
◆ Model: Perkins 4016TAG2A
◆ Construction:Equiping with independent four valves cylinder head to facilitate air flow. The single fuel injector
   ensures ultra atomization of diesel fuel and combust at high speed under full control. Sharing a large number of
   components with other 4000 series engines helps to
   reduce the inventory of the manufacture.
◆ Intake: Turbocharged
◆ Fuel system: Digital governor with isochronous function,
   speed is adjustable to ISO8528-5 standard; direct
   injection system with lift pump
◆ Lubrication system: Wet all aluminum oil pan with oil
   injector and oil dip stick
◆ Cooling system: Two sets of double thermostat
◆ Filtration system: Embedded air filter and turbocharger;
   rotary full-flow fuel filter; rotary full-flow oil filter
◆ Electrical equipment: 24V starter and 24V alternator,
   built-in regulator (DC output); turbine inlet high
   temperature protection switch; double coolant high
   temperature protection switch;double low oil pressure protection switch
◆ Lower operating cost: The standard replacement oil interval is set to 500 hours
◆ Engine Operating Environment Description:
   The engine can work under the following conditions without modulating power:
   1800r/min engine--altitude less than 1000 m, ambient temperature less than 40 ℃
   1500r/min engine--altitude less than1000 m, ambient temperature less than 40 ℃
 Performance Description Alternator
◆ Optional Alternator: Stamford / Marathon/ Faraday/Engga/Mecc Alt
◆ Brushless, 4 pole rotating magnetic field, single bearing with
   protective cove
◆ Insulation: H Class.
◆ Standard IP23 grade
◆ Cooling system
◆ AC exciter, rotate rectifying unit
◆ Surface of stator winding is covered with damp-proof epoxy
   Insulation varnish after impregnation proceeding
◆ Rotor and exciter is proceeded with high temperature insulating
   resin, Will be more applicable for harsh environment.
◆ Rotor dynamic balancing comply to standard BS5625,class 2.5
◆ Sealed with advanced lubricating grease prolongs life of bearing.
Notes: Above data of alternator comes from Stamford. Proper specification is subject to the practice
alternator if customers choose other alternator
                                                               2
 Intelligent Control System
  Standard Detection Function
◆ 3 phases voltage Ua,Ub,Uc              ◆ 33 phases
                                         ◆    phases current
                                                     current La,Lb,Lc
                                                             La,Lb,Lc
◆ Frequency F1                           ◆ Active
                                         ◆ Active power
                                                  power PA
                                                        PA
◆ Apparent power PR                      ◆ Power
                                         ◆ Power factor
                                                  factor PF
                                                         PF
◆ Coolant temperature WT                 ◆ Temperature ℃
                                         ◆ Temperature ℃ display
                                                         display
◆ Oil pressure OP                        ◆ KPa/Psi/Bar
                                         ◆ KPa/Psi/Bar display
                                                       display
◆ Speed RPM                              ◆ Battery
                                         ◆ Batteryvoltage
                                                   voltageVV
◆ HC timer 99999 hours records
◆ Maximum cumulative times of starting can reach 999999
  Standard Protection Function
Genset Protection
◆ Programmable alarm and status input ◆ Emergency stop
 Engine Protection
◆ Stop for over speed                     ◆ Alarm for low/high battery voltage
◆ Alarm/Stop for low oil pressure         ◆ Alarm for shortage of battery
◆ Alarm/Stop for coolant high temperature
◆ Stop for failure to start/jigger
◆ Indication of sensor fault
 Alternator Protection
◆ Stop for over high/low voltage              ◆ Stop for over frequency
◆ Alarm/stop for over current                 ◆ Stop for low frequency
◆ Stop for loss of voltage detection signal
 Control System Components
◆ Control switch—manual/auto/stop/start
◆ Screen menu selection button
◆ Setting button                              ◆ Emergency stop button
◆ Fault status indicators                     ◆ Digital display
  Communication Interface                      (optional function)
  InterfaceCommunicatio
◆ International standard MODBUS communication protocol with error detection as well as RS232/ RS485 (RS485 is
                    n has functions of remote control, telemetry and telesignalling, which are facilitate to monitor
    opto-isolated type)
  Interface
   genset.  Communication
                Interface
Notes: Above data of controller comes from POWERTEC GC6110. Proper specification is subject to customers’
practice controller if other controller is selected.
                                                            3
Data sheet of Genset
                                          Model                         PPE2250
                            Prime Rating (kw)                               1600
           Genset
                            Standby Rating (kw)                             1800
                            Prime current(A)                                2887
                            Frequency(hz)                                     50
                            Engine Model                                 4016TAG2A
                            Gross Engine output-Prime (kw)                  1715
                            Gross Engine output-Standby (kw)                1886
                            Bore * stroke (mm)                             160*190
                            Cylinders and structure                       16 V type
                            Displacement(Liter)                             61.12
                            Compression Ratio                               13.6:1
                                                                    Turbocharged/ Air-Air
                            Intake way
                                                                         intercooler
                            Max intake resistance (KPa)                      2.5
                            Air intake (m3/h)                               8220
                            Max exhaust back pressure (KPa)                   3
                            Exhaust gas flow (m3/h)                         23220
                            Exhaust temp (℃)                                 493
                            Cooling way                             Water Radiator & Fan
                            Fan exhaust flow (m3/min)                       2430
                            Coolant capacity (L)                             316
                            Highest water temperature(℃)                      98
      Engine & Alternator
                            Minimum air opening to room (m2)               10.0/9.0
                            Thermostat range (℃)                            71-85
                            Max oil temperature (℃)                          105
                            Lubrication system oil capacity (L)              237
                            Fuel consumption(L/H)                            434
                            Standard Governor/Class                       Electronic
                                                                  Marathon--- MX-1800-4
                                                                  Engga------- EG500-1800N
                            Optional Alternator Model
                                                                  Stamford---- PI 734F
                                                                  Faraday----- FD7F1-4
                            Rated Voltage(V)                               400/230
                            Output Way                                3 Phases, 4 wires
                            Rated power factor                               0.8
                            Exciter                                 Brushless, Self-exciter
                            Max voltage regulation                           ±1%
                            Phase                                             3
                            Protection class                               IP21-23
                            Insulation class                                  H
          Controller        Brand and Model                         POWERTEC GC6110
                                                   4
Dimension and Weight
                             Dimension mm             Weight      Fuel Tank Capacity
            Type
                               (L*W*H)                 KG                 L
         Open Type           6650*2300*2562            14361                 -
         Silent Type                  -                   -                  -
      Notes::Above data are for reference only. Specific size is subjected to actual measurement.
    Contact Way          Powertec Generator System Co., Ltd
                         Add: Danshui Yanna Industry Zone, Huiyang, Huizhou, Guangdong, China
                         Tel:0752-3911119 / 0752-3911118
                         FAX:0752-3911110
                         Web:www.powertec.com.cn         Email:sales@powertecgs.com