Features

 High quality, reliable and complete generating sets.


 4; generating set carries a comprehensive test program
Every
which includes 25%, 50%, 75%, 100% , 110% loading test and
series protecting function (example: Low oil pressure , High
coolant temperature, over current/load etc.) check.
 Easy for operation and maintenance.
 Compact structure &high-strength chassis.
 Base frame design incorporates an intergrade fuel tank for at
least 8 hours running (up to 650KVA).
 The canopy body painting adopts the HenKel pretreatment
process and the base frame painting adopts sandblasting
+AkzoNobel powder, the paint warranty period can be 3 years.
 High-performance free-maintenance batteries with isolation
switch.
 Anti- vibration pads are mounted between the engine/alternator
feet and the base frame.
 Top lifting point and steel base frame with forklift holes, easy for
transportation.
 Compliance with international electrical safety standards.
 Complete protection functions and safety labels.
 A large number of matching optional to meet the needs of Engine Specifications
various customers.
Engine model & manufacturer 4008TAG2

SPECIFICATION OPEN TYPE SILENT TYPE Number Of Cylinder 8 Vertical In – Line

Model Genset PL – 1000 P PL – 1000 P Bore And Stroke 160.0 x 190.0 mm

Power Output 1000 Kva / 800 Kw 1000 kva / 800 Kw Displacement 30.561 Litres
Turbocharged and Air to Air Charge
Phase 3 ( Three) 3 ( Three) Aspiration
Cooled
Frequency 50 Hz @1500RPM 50 Hz @1500RPM Cycle 4 Stroke
Voltage 220 / 380 V 220 / 380 V Cumbustion System Direct Injection
Fuel Tank, Residential
Fuel Tank, Residential Compression Ratio 13.6 : 1
Accessories Muffler, Batteries, Tools
Muffler, Batteries, Tools Kit
Kit
Rotation Anti – Clockwise, viewed on Flywheel
Dimension LxWxT 4860 x 2050 x 2550 mm 6060 x 2440 x 3500 mm
Total Lubricating Capacity 153.0 Liter
Weight 7490 Kg 12490 Kg
Cooling System Water Cooled
Fuel tank Opt Opt
Total Coolant Capacity 143.0 Litres

Also available in the following voltages: Fuel Consumption (L/H) 162.0(75% Load) /215.0(100% Load)
415/240V, 380/220V, 220/127V, 200/115V (According to customer requirements).
Rated Power/prime Power(PRP) :
 Heavy duty Perkins diesel engine
Continuous running at variable load for unlimited periods with 10% overload available
 Four stroke, water cooled, Turbocharged and Air To Air
for 1 hour in any 12 hour period, in accordance with ISO8528.
Charge Cooled aspirated
Standby Power/Emergency Standby Power (ESP):  Direct injection fuel system
The maximum power available during a variable electrical power sequence, no overload  Electric governor system
on these ratings, in accordance with ISO 8528.  24V DC starter and charge alternator
 Replaceable fuel filter and dry element air filter
 Cooling radiator and fan
 Starter battery(with lead acid) including rack and cables
 Flexible fuel connection hoses
 Industrial capacity exhaust silencer and steel bellows
 Operation manuals and circuit diagram documents

Generator Silent Type Generator Open Type


Alternator Specifications
Alternator Manufacturer Stamford

Design Design Brushless Single Bearing, Revolving Field

Stator 2/3 Pitch

Rotor Single Bearing, Flexible Disc

Insulation System Class H

Standard Temperatur Rise 125 - 163°C Continous

Exciter Type Self Excited

Phase Rotation A (U), B (V), C (W)

Alternator Cooling Direct Drive Centrifugar Blower Fan

AC Waveform Total Harmonic Distortion No Load <1.5% Non Distorting Balanced Linear Load <5%

Telephone Influence Factor ( TIF ) <50 per NEMA MGI – 22.43

Telephone Harmonic Factor ( THF ) <2%

Control System

DSE4520 ( Deepsea ) DSE4620 ( Deepsea ) DSE7320 ( Deepsea )

Suitable for > 250KVA Gen - sets Suitable for for all series Gen - sets

The Controller Display DSE4520 Control System DSE7320 Control System


Voltage between phases(L-L) √ √
Voltage between neutral and phase(L-N) √ √
Frequency √ √
3 Phase current √ √
Real power(kW) and apparent power(kVA) √ √
Power factor √ √
Engine speed √ √
Running hours √ √
Coolant temperature √ √
Oil pressure √ √
Battery voltage √ √
LCD alarm indication √ √
3 Phase mains (utility) sensing √ √
Emergency stop button √ √
High coolant temperature √ √
Low oil pressure √ √
Over current/load √ √
under/over speed, frequency & voltage √ √
Low/High battery voltage √ √
Low coolant level √ √
Generating Set Type

Genset Type Silent Genset Type Trailer Genset Type Open

Panel ATS / Synchrone

Panel ATS
Panel Synchrone

Sparepart

Module ( Deepsea ) Switch Temperatur Switch Oli Switch Aki Filter Solar

Filter Oli Filter Oli Filter Udara Speed Control AVR

Baterai Charger Camp Shaft Ampere Dynamo Stater Dynamo Bearing Generator