CONTROL EQUIPMENT
DIGITAL TIME SWITCHES
                           The new range of time switches are a great economic technical solution for time management
                           PUKPќLYLU[HWWSPJH[PVUZ
                           These time switches consist of products that are easy to read thanks to 1 “1/3 backlit
                           LCD display with large numbers, which thanks to the optimal contrast, allows to visualize
                           immediately the load status as well as the day, the current time and if a manual intervention
                           ^HZZLSLJ[LK;OLWLYMVYTHUJLVќLYLKTHRL[OLTZ\P[HISLMVY\ZLPU]HYPV\ZHWWSPJH[PVUZ
                           to run programs with interventions lasting a minimum of one second, up to interventions
                           that can last up to a week. Thanks to the internal memory, you can save up to 20 ON-OFF
                           WYVNYHTZ[OH[PU^LLRS`]LYZPVUZJHUILNYV\WLKPU[VNYV\WZVMKH`ZVYKPќLYLU[MVYLHJO
                           KH`VM[OL^LLR;OL^PKLVќLYVM[PTLZ^P[JOLZHSSV^Z`V\[VÄUKHS^H`Z[OLWYVK\J[[VÄ[
                           your needs. They are available in daily and weekly versions, with one or two contacts, with or
                           without the daylight saving time change.
                           SPECIAL FEATURES
                           • Large 1 “1/3 display
     backlit display       • Minimum ON / OFF Programming 1 second
                           • Programming even past midnight, between different days
                           • Memory capacity: 20 ON / OFF programs coupled in blocks of days
                           • EEPROM memory to maintain the programs beyond the power reserve
                           • Power reserve: 15 days
                           • Hinged protective cover
                           • Sealable protective cover
                           • Terminals 6 sq.m.
                           • Terminals with captive screws
                           KEY
                           PROGR = programming input
                                 =     selection of desired program 1 or 2
                           DAY   =     selection of day / group of days
                                 =     data input ON status / OFF status
                           PROGR =     programming end
                           Possibility of manual override of ON / OFF permanent status
                           PROGRAMMING EXAMPLES
                            1    Automatic gate opening at h. 8:00 and closing at h. 9:00
                                                                      1 sec.
                                 DAY                                                             ON
                           P01   1-2-3-4-5                                                       OFF
                                                                       8:00
                                                                                1 sec.
                                 DAY                                                             ON
                           P02   1-2-3-4-5
                                                                                 9:00
                                                                                                 OFF
                            2    Control box time profiles in zone systems
                                 DAY                                                             ON
                           P01   1-2-3-4-5                                                       OFF
                                                               6:00              8:30
                                 DAY                                                             ON
                           P02   1-2-3-4-5
                                                                                                 OFF
                                                                               17:00     23:00
                                 DAY                                                             ON
                           P03   6-7
                                                               6:00                      23:00
                                                                                                 OFF
56
TIME SWITCHES WITH AUTOMATIC DAYLIGHT SAVING TIME CHANGE
1IO 7080
Digital daily time switch with automatic daylight saving time change 1 channel - 2 DIN
1 potential-free changeover contact
1IO 7081
Digital weekly time switch with automatic daylight saving time change 1 channel - 2 DIN
1 potential-free changeover contact
1IO 7281
Digital weekly time switch with automatic daylight saving time change 2 channels - 2 DIN
2 potential-free changeover contacts
TIME SWITCHES WITHOUT AUTOMATIC DAYLIGHT SAVING TIME CHANGE
1IO 6080
Digital daily time switch without daylight automatic saving time change 1 channel - 2 DIN
1 potential-free changeover contact
1IO 6081
Digital weekly time switch without automatic daylight saving time change 1 channel - 2 DIN
1 potential-free changeover contact
                Legenda:
                Pin  1 VDD (power supply)
 1
                Pin
                Pin 12 VDD
                        relay   output 1
                            (alimentazione)
 2
 3
                Pin 23 uscita
                Pin     relayrelè 1
                                output   2
 4
                Pin 3 uscita relè 2
                Pin
                Pin 44 massa
                        GNDGND  earth
DIGITAL DAILY TIME SWITCH MODULES WITH AUTOMATIC DAYLIGHT
SAVING TIME CHANGE
1IO 1080/M
Digital daily time switch module with automatic daylight saving time change 1 channel
1IO 1280/M
Digital daily time switch module with automatic daylight saving time change 2 channels
1IO 1081/M
Digital weekly time switch module with automatic daylight saving time change 1 channel
1IO 1281/M
Digital weekly time switch module with automatic daylight saving time change 2 channels
                                                                                             57
                    CONTROL EQUIPMENT
                    DIGITAL TIME SWITCHES
TECHNICAL SPECIFICATIONS
                                          With automatic daylight saving time change   Without automatic daylight saving time change
1IO                                         7080           7081            7281              6080                   6081
Daily programming
Daily - weekly programming
Output channels n.                            1              1               2                 1                      1
Automatic daylight saving time change
ON-OFF minimum time 1 second
Backlit display
                     Power supply voltage                                 230V a.c. 50 - 60Hz
                     Contact rated data                                   potential-free NC contact
                                                                          16 (2) A / 250V a.c.
                     Max program number (ON-OFF)                          20 (matchable in blocks of days)
                     ON - OFF minimum connection time                     1 second
                     Displays                                             1” 1/3 backlit LCD display
                     Max. commutable power                                3500 VA (for individual contact)
                     Power: Incandescent LPs                              2300 W
                     Power: Fluorescent tube LPs, not                     1000 W
                     compensated
                     Power: Parallely comp. fluorescent tube LPs          >[V[JHWHJP[`э-
                     Power: Compact, fluorescent LPs                      600W
                     Max cross-section of wires to                        6 mm2
                     terminals
                     Protection degree (IP)                               IP 20 - IP 40 (on rear of switchboard)
                     Type of output                                       terminals with captive screw
                     Insulation class                                     II
                     ON / OFF relay signalling                            ON / OFF in LCD display
                     Charge reserve                                       max 15 days
                     Type of reserve                                      NiMH rechargeable battery
                     Time tolerance                                       + - 0.5 sec / day
                     Operating temperature limits                         0°C / +50°C
                     Storing temperature                                  -10°C / +50°C
                     Type of installation                                 DIN rail / on rear of switchboard
                     Housing                                              thermoplastic - grey RAL 7035
                     Type of use                                          civil / tertiary / industrial
                     Controls                                             programming keys, ON / OFF manual
                                                                          override key
                     Clock setting accuracy                               digital for hours / minutes
                     Daylight saving time change                          for 4 geographic ares
                     Digital programming                                  for hours / minutes / seconds
                     Dimensions (L x W x H) mm                            35 x 60 x 90
58
The large backlit display allows for a clear and immediate reading of the relays status, current time and day and any manual
override.
              DISPLAY AND KEYS FUNCTION                                                                ICONS DISPLAY
                                                                                  Channel 2 OFF
                                            LCD display                                                                      Manual override
                                                                                  Channel 1 ON
                                                                                                                             N. program
Hours, minutes, seconds                     Confirm                                                                          running
programming
                                            Reset
                                            Channel 2 manual
                                            override
Day programming
                                            Programming
                                            key
                                            Channel 1 manual                                                              Week days
                                            override                                                                      (only weekly version)
          DIMENSIONS (mm)                                                                    WIRING DIAGRAM
          1 2 3 4 5                                                             1 2 3 4 5                                             1 2 3 4 5
                                                                                 C1                                                    C1
90
                                                                                                                                       C2
                                                                                6 7 8 9 10                                            6 7 8 9 10
          6 7 8 9 10
              35             60                                     N                                                 N
                                                          230 Vac                                           230 Vac
                                                                    L                                                 L
                                                           Range:                                            Range:
            Front         side                             1IO 6080 (daily, 1 channel)                       1IO 7281 (weekly, 2 channels, +/- 1hr auto)
                                                           1IO 6081 (weekly, 1channel)
                                                           Range:
                                                           1IO 7080 (daily, 1 channel, +/- 1hr auto)
                                                           1IO 7081 (weekly, 1channel, +/- 1hr auto)
                                                                                                                                                    59