CENTRAL 71 4-01

Flange Adapter
Figure 71
Tyco Fire Products --- www.tyco-grooved.com
451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA
Customer Service/Sales: Tel: (215) 362-0700 / Fax: (215) 362-5385
Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Grooved Piping Products

(10) years from date of shipment by


General Ordering Tyco Fire Products. No warranty is
given for products or components
Description Procedure manufactured by companies not
affiliated by ownership with Tyco Fire
Products or for products and
Ordering Information: When placing an components which have been subject
order, indicate the full product name. Please to misuse, improper installation,
specify the quantity, figure number, type of corrosion, or which have not been

TE
gasket, EPDM “E”, and size. installed, maintained, modified or
repaired in accordance with applicable
Availability and Service: Grooved Piping Standards of the National Fire
Products, valves, accessories and other Protection Association (NFPA), and/or
®
FM products are available throughout the U.S., the standards of any other Authorities
Having Jurisdiction. Materials found by
See Fire Protection Submittal Sheet for pressure
LE
Canada, and internationally, through a
network of distribution centers. You may Tyco Fire Products to be defective shall
rating and Listing and Approval information write directly or call 215-362-0700 for the be either repaired or replaced, at Tyco
distributor nearest you. Fire Products’ sole option. Tyco Fire
The Figure 71 Flange Adapter allows a Products neither assumes, nor
direct transition from flanged components
Care and authorizes any person to assume for it,
O
into a grooved piping system. Flange bolt any other obligation in connection with
patterns conform to ANSI Class 125 and 150 the sale of products or parts of
standards.
Maintenance products. Tyco Fire Products shall not
BS

be responsible for sprinkler system


The owner is responsible for the inspection, design errors or inaccurate or
testing, and maintenance of their fire incomplete information supplied by
Technical protection system and devices in
accordance with the applicable standards of
Buyer or Buyer’s representatives.
IN NO EVENT SHALL TYCO FIRE
Data the National Fire Protection Association PRODUCTS BE LIABLE, IN
O

(e.g., NFPA 25), in addition to the standards CONTRACT, TORT, STRICT


of any authority having jurisdiction. The LIABILITY OR UNDER ANY OTHER
Figure: 71 installing contractor or product
Sizes: 2" - 12" LEGAL THEORY, FOR INCIDENTAL,
manufacturer should be contacted relative to INDIRECT, SPECIAL OR
Approvals: any questions. Any impairment must be
UL, FM, and ULC CONSEQUENTIAL DAMAGES,
immediately corrected. INCLUDING BUT NOT LIMITED TO
See Fire Protection Submittal Sheet for
exact Listing / Approval information. It is recommended that automatic sprinkler LABOR CHARGES, REGARDLESS OF
Manufacturing Source: systems be inspected, tested, and WHETHER TYCO FIRE PRODUCTS
Domestic maintained by a qualified Inspection Service. WAS INFORMED ABOUT THE
Housing: POSSIBILITY OF SUCH DAMAGES,
Ductile iron conforming to
ASTM A-536, Grade 65-45-12
Limited AND IN NO EVENT SHALL TYCO
FIRE PRODUCTS’ LIABILITY EXCEED
AN AMOUNT EQUAL TO THE SALES
Protective Coatings:
• Non-lead orange paint Warranty PRICE.
• Hot dipped galvanized conforming to THE FOREGOING WARRANTY IS MADE
ASTM A-153 Products manufactured by Tyco Fire IN LIEU OF ANY AND ALL OTHER
Gasket: (specify when ordering) Products are warranted solely to the WARRANTIES EXPRESS OR IMPLIED,
• Grade E EPDM green color code original Buyer for ten (10) years against INCLUDING WARRANTIES OF
• Prelubricated (Grade E EPDM) defects in material and workmanship MERCHANTABILITY AND FITNESS
(See Gasket Grades and Recommendations when paid for and properly installed FOR A PARTICULAR PURPOSE.
Sheet for aid in selecting the proper and maintained under normal use and
gasket) service. This warranty will expire ten
No. 18-8.0
Figure 71 Flange Adapter

A C

F B E D

Pipe Max † Max † Dimensions Bolts ‡ Net


Pressure End Load A B C *D *E F Wt.
Size
Size O.D. psi Lbs. Inches Inches Inches Inches Inches Inches Qty. lbs.
Dia. x Lg.
kPa N mm mm mm mm mm mm kg
250 1,107 6.38 4.75 0.75 2.38 3.41 7.25 5
3.0
2" 2.375" /8" x 3" 4
1,724 4,924 162.1 120.7 19.1 60.5 86.6 184.2 1.4
250 1,622 7.00 5.50 0.88 2.88 3.91 7.88 5.0

TE
2 1/ 2" 2.875" 5
/8" x 3" 4
1,724 7,215 178.0 140.0 22.0 73.0 99.0 200.0 2.3
250 2,404 7.50 6.00 0.94 3.50 4.53 9.88 5
5.6
3" 3.500" /8" x 3" 4
1,724 10,693 190.5 152.4 23.9 88.9 115.1 251.0 2.5
250 3,974 9.00 7.50 0.94 4.50 5.53 9.90 5
7.0
4" 4.500" /8" x 3" 8
1,724 17,676 228.6 190.5 23.9 114.3 140.5 251.5 3.2
250 6,073
LE
10.00 8.50 1.00 5.56 6.72 11.38 9.2
3
5" 5.563" / 4 " x 31 / 2 " 8
1,724 27,013 254.0 215.9 25.4 141.2 170.7 289.1 4.2
250 8,614 11.00 9.50 1.00 6.62 7.78 11.88 3
10.0
6" 6.625" / 4 " x 31 / 2 " 8
1,724 38,315 279.4 241.3 25.4 168.1 197.6 301.8 4.5
250 14,599 13.50 11.75 1.13 8.62 9.94 14.38 16.6
O
3
8" 8.625" / 4 " x 31 / 2 " 8
1,724 64,936 342.9 298.5 28.7 218.9 252.5 365.3 7.5
250 22,679 16.00 14.25 1.19 10.75 12.31 16.88 7
21.8
10" 10.750" /8" x 4" 12
1,724 100,876 406.4 362.0 30.2 273.1 312.7 428.8 9.9
BS

250 31,903 19.00 17.00 1.25 12.75 14.31 20.00 7


24.2
12" 12.750" /8" x 4" 12
1,724 141,905 482.6 431.8 31.8 323.9 363.5 508.0 11.0

† Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ on
other pipe materials and/or wall thickness. Contact Tyco Fire Products for details. See Fire Protection Equipment Submittal Sheet for Listing
O

and Approval pressure ratings.


* Dimensions D and E represent minimum and maximum sealing surfaces.
‡ Bolts and Nuts are not supplied. Bolt lengths are standard; it is the responsibility of the purchaser to verify
correct length for the intended application.

General Notes: It is the Designer’s responsibility to select products suitable for the intended service and to ensure
that pressure ratings and performance data is not exceeded. Always read and understand the installation
instructions (IH-1000). Never remove any piping component nor correct or modify any piping deficiencies Certified Company
without first depressurizing and draining the system. Material and gasket selection should be verified to be
compatible for the specific application.

Flow Control Tyco Fire Printed in U.S.A. 4-01