Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500
BlazeMaster ®
CPVC Fire Sprinkler Pipe & Fittings
Submittal Sheet
General
Description                                 Technical
Tyco® CPVC Pipe and Fittings pro-
duced by Tyco Fire & Building Prod-
                                            Data
ucts (TFBP) are designed exclusively        Sizes
for use in wet pipe automatic fire sprin-   3/4" to 3"
kler systems. The Tyco CPVC Pipe            Maximum Working Pressure
and Fittings are produced from Blaze-       175 psi
Master® CPVC compound that is a
specially developed thermoplastic           Approvals
compound composed of post chlorin-          UL, FM, C-UL, NSF, LPCB, MEA, and
ated polyvinyl chloride (CPVC) resin        the City of Los Angeles. (Refer to In-
and state of the art additives. Tyco        stallation Handbook IH-1900 dated
CPVC Pipe and Fittings are easier to        June 2008 for exact listing/approval
install than traditional steel pipe sys-    information.)
tems, and at the same time, provide         Manufacture Source
superior heat resistance and strength       U.S.A.
as compared to traditional CPVC and
PVC piping materials used in the            Material
plumbing trade. Various adapters are        • Pipe: ASTM F442, SDR 13.5
available to connect CPVC pipe to me-
tallic piping. All female pipe thread       • Fittings: ASTM F438 (Sch. 40) and
adapters have brass inserts for dura-         ASTM F439 (Sch. 80), ASTM F1970
bility. Grooved adapters connect di-
                                            Color
rectly to grooved end valves and me-
                                            Orange
tallic pipe, with flexible grooved end
couplings.
NOTICE
Tyco® CPVC Pipe and Fittings pro-
duced with BlazeMaster® CPVC com-
pound described herein must be in-
stalled and maintained in compliance
with this document and with the appli-
cable standards of the National Fire
Protection Association, in addition to
the standards of any authorities having
jurisdiction. Failure to do so may im-
pair the performance of these devices.
The owner is responsible for maintain-
ing their fire protection system and de-
vices in proper operating condition.
The installing contractor or sprinkler
manufacturer should be contacted
with any questions.
                                                                                     BlazeMaster® is a registered trademark
                                                                                     of The Lubrizol Corporation
Page 1 of 2                                              JUNE, 2008                                           TFP1915
Page 2 of 2                                                                                                   TFP1915
Installation                                Limited
Tyco®  CPVC Pipe and Fittings pro-
duced by Tyco Fire & Building Prod-
                                            Warranty
ucts (TFBP) are to be installed in          Products manufactured by Tyco Fire &
accordance with Installation Hand-          Building Products (TFBP) are war-
book IH-1900 dated June 2008.               ranted solely to the original Buyer for
                                            ten (10) years against defects in mate-
                                            rial and workmanship when paid for
Care and                                    and properly installed and maintained
                                            under normal use and service. This
Maintenance                                 warranty will expire ten (10) years
                                            from date of shipment by TFBP. No
The owner is responsible for the in-        warranty is given for products or com-
spection, testing, and maintenance of       ponents manufactured by companies
their fire protection system and de-        not affiliated by ownership with TFBP
vices in compliance with this docu-         or for products and components which
ment, as well as with the applicable        have been subject to misuse, improper
standards of the National Fire Protec-      installation, corrosion, or which have
tion Association (e.g., NFPA 25), in        not been installed, maintained, modi-
addition to the standards of any            fied or repaired in accordance with ap-
authority having jurisdiction. The in-      plicable Standards of the National Fire
stalling contractor or product manufac-     Protection Association, and/or the
turer should be contacted relative to       standards of any other Authorities
any questions.                              Having Jurisdiction. Materials found
Automatic sprinkler systems should be       by TFBP to be defective shall be either
inspected, tested, and maintained by a      repaired or replaced, at TFBP’s sole
qualified Inspection Service in accord-     option. TFBP neither assumes, nor
ance with local requirements and/or         authorizes any person to assume for it,
national codes.                             any other obligation in connection with
                                            the sale of products or parts of prod-
                                            ucts. TFBP shall not be responsible for
NOTICE
                                            sprinkler system design errors or inac-
                                            curate or incomplete information sup-
Before closing a fire protection system
                                            plied by Buyer or Buyer’s repre-
control valve for inspection or mainte-
                                            sentatives.
nance work on the fire protection sys-
tem that it controls, permission to shut    In no event shall TFBP be liable, in
down the affected fire protection sys-      contract, tort, strict liability or under
tem must first be obtained from the         any other legal theory, for incidental,
proper authorities and all personnel        indirect, special or consequential dam-
who may be affected by this action          ages, including but not limited to labor
must be notified.                           charges, regardless of whether TFBP
                                            was informed about the possibility of
After placing a fire protection system      such damages, and in no event shall
in service, notify the proper authorities   TFBP’s liability exceed an amount
and advise those responsible for moni-      equal to the sales price.
toring proprietary and/or central sta-
                                            The foregoing warranty is made in lieu
tion alarms.
                                            of any and all other warranties, ex-
                                            press or implied, including warranties
                                            of merchantability and fitness for a par-
                                            ticular purpose.
                                            This limited warranty sets forth the ex-
                                            clusive remedy for claims based on
                                            failure of or defect in products, materi-
                                            als or components, whether the claim
                                            is made in contract, tort, strict liability
                                            or any other legal theory.
                                            This warranty will apply to the full ex-
                                            tent permitted by law. The invalidity, in
                                            whole or part, of any portion of this
                                            warranty will not affect the remainder.
                © 2008 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446