Datasheet RAC05-K - 480
Datasheet RAC05-K - 480
The RAC05-K/480 series of 5 watt AC/DC units are specially designed for harsh industrial and outdoor
2‘‘ x 1‘‘ 3 arrant
y
w
mains conditions. These PCB-mount power supplies are rated to OVC III and/or PD3 conditions from
100-480VAC nominal input lines with phase-to-phase or single phase operation in class II installations
by just adding a single fuse externally. The modules support an operating temperature range from -40°C Single Output
to +80°C and come with fully protected outputs as well as EMC Class B compliance in floating output
connections. All these features make them an ideal fit for integration into smart grid, renewable energy,
smart metering and IoT applications.
Selection Guide
Part Input Output Output Efficiency Max. Capacitive
Number Voltage Range Voltage Current typ (1) Load (2)
[VAC] [VDC] [mA] [%] [µF]
RAC05-05SK/480 85-528 5 1000 63 10000
RAC05-12SK/480 85-528 12 420 65 1200 C
O
M
C O N V ER
T
C
O
M
CO NVE R
T
E
E
RE
RE
R
R
ERP
S
S
RAC05-15SK/480 85-528 15 330 60 1000 RoHS 2 + REACH
compliant compliant compliant
10 from 10
Notes:
CO
CO
TS
TS
M M
C
C
PL U P U
IA N D LIA D
T PRO N T PRO
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max Cap Load is tested at nominal input and full resistive load
Model Numbering
RAC05-__ _K/480
nom. Output Power Single
5003727
Output Voltage
IEC/EN62368-1 compliant
Ordering Examples: UL61010-1 certified
RAC05-05SK/480 5Vout Single Output CSA C22.2 No. 61010-1 certified
RAC05-12SK/480 12Vout Single Output
IEC/EN61010-1 certified
IEC/EN61204-3 compliant
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) EN55032 compliant
EN55014-1 compliant
BASIC CHARACTERISTICS EN55014-2 compliant
Parameter Condition Min. Typ. Max. EN55024 compliant
Internal Input Filter Pi type EN61000 compliant
CB Report
nom. Vin= 480VAC 85VAC 528VAC
Input Voltage Range (3,4)
120VDC 745VDC
100VAC 110mA
Input Current 400VAC 40mA
480VAC 35mA
400VAC 18A
Inrush Current cold start at +25°C
480VAC 20A
No load Power Consumption 500mW
Input Frequency Range AC Input 47Hz 63Hz
Minimum Load 0%
Notes:
Note3: The products were submitted for safety files at AC-Input operation
Note4: Refer to „Line Derating“
continued on next page
Notes:
Note5: Measurements are made with a 0.1μF MLCC & 10μF E-cap in parallel across output. (low ESR)
RAC05-05SK/480 RAC05-12SK/480
100 100
90 90
80 80
70 70
Efficiency [%]
Efficiency [%]
60 60
50 50
40 40
30 230VAC 30 230VAC
400VAC 400VAC
20 20 480VAC
480VAC
10 10
0 0
0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100
Output Load [%] Output Load [%]
RAC05-15SK/480
100
90
80
70
Efficiency [%]
60
50
40
30 230VAC
400VAC
20 480VAC
10
0
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
Deviation at 400/480VAC
RAC05-05SK/480 RAC05-12SK/480
1 1
0.5 0.5
Deviation [%]
Deviation [%]
0 0
-0.5 -0.5
-1 -1
0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100
Output Load [%] Output Load [%]
RAC05-15SK/480
1
0.5
Deviation [%]
-0.5
-1
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
PROTECTIONS
Parameter Type Value
Input Fuse (6) external slow blow 600VAC, 2A
Limited Power Source (LPS) according to IEC62368-1 CB Report yes
Short Circuit Protection (SCP) below 100mW hiccup, automatic restart
Over Voltage Protection (OVP) 150% - 195%, hiccup mode
Over Voltage Category OVCIII
Over Current Protection (OCP) 150% - 195%, hiccup mode
Class of Equipment Class II
ENVIRONMENTAL
Parameter Condition Value
full load -40°C to +60°C
Operating Temperature Range (8) @ natural convection 0.1m/s
refer to „Derating Graph (8)“ -40°C to +80°C
Maximum Case Temperature +100°C
Temperature Coefficient 0.05%/K
Thermal Impedance 0.1m/s airflow 16K/W
Operating Altitude according to 61010-1 5000m
Pollution Degree according to 61010-1 PD3
Operating Humidity non-condensing 5% - 95% RH max.
Vibration according to MIL-STD-202G 10-500Hz, 2G 10min./1cycle, 60min. each along x,y,z axes
+25°C 105 x 103 hours
Design Lifetime
+60°C 40 x 103 hours
+25°C >1726 x 103 hours
MTBF according to MIL-HDBK-217F, G.B.
+40°C >1585 x 103 hours
Derating Graph (8) Line Derating
(@ Chamber and natural convection 0.1m/s)
100 100
90 90
80 80
70 70
Output Load [%]
Output Load [%]
60 60
50 50
40 40
30 30
20 20
10 10
0 0
-40 -20 0 20 40 60 80 100 120 85 90 528
Ambient Temperature [°C] Input Voltage [VAC]
Notes:
Note8: The 12Vout and 15Vout were submitted for safety file (190415125GZU-001) for full load operation up to TAMB= +50°C only
embossed logo
27.4
Pin Connections
Pin # Single
51.5 26.3 1 VAC in (N) (L2)
2 VAC in (L) (L1)
3 -Vout
4 +Vout
23.0
Ø1.0 +0.15/-0.05
6.0 ±1.0
20.32
2 1 4
1 4 2
F VACIN (N)
-VOUT
D3 D4 D5
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.