0% found this document useful (0 votes)
190 views7 pages

Datasheet RAC05-K - 480

The document describes the RAC05-K/480 series of 5 watt AC/DC power supplies. These PCB-mount power supplies are rated for harsh industrial and outdoor conditions, with an input voltage range of 85-528VAC and an operating temperature range of -40°C to +80°C. They provide fully protected floating outputs that are EMC Class B compliant and suitable for applications in smart grids, renewable energy, smart metering, and IoT. The power supplies are available with output voltages of 5V, 12V, or 15V and come with a 2 year warranty.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
190 views7 pages

Datasheet RAC05-K - 480

The document describes the RAC05-K/480 series of 5 watt AC/DC power supplies. These PCB-mount power supplies are rated for harsh industrial and outdoor conditions, with an input voltage range of 85-528VAC and an operating temperature range of -40°C to +80°C. They provide fully protected floating outputs that are EMC Class B compliant and suitable for applications in smart grids, renewable energy, smart metering, and IoT. The power supplies are available with output voltages of 5V, 12V, or 15V and come with a 2 year warranty.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

• OVC III and PD3 rating

Features • Continious max withstanding voltage 528VAC


• UL certified input 90-318VAC AC/DC Converter
• Operating temperature range: -40°C to +85°C
Regulated • Class II installations (without FG)
Converter •

EN55032 class “B” with floating outputs
No load power consumption <0.5W RAC05-K/480
Description 5 Watt YEA R

The RAC05-K/480 series of 5 watt AC/DC units are specially designed for harsh industrial and outdoor
2‘‘ x 1‘‘ 3 arrant

y
w
mains conditions. These PCB-mount power supplies are rated to OVC III and/or PD3 conditions from
100-480VAC nominal input lines with phase-to-phase or single phase operation in class II installations
by just adding a single fuse externally. The modules support an operating temperature range from -40°C Single Output
to +80°C and come with fully protected outputs as well as EMC Class B compliance in floating output
connections. All these features make them an ideal fit for integration into smart grid, renewable energy,
smart metering and IoT applications.

Selection Guide
Part Input Output Output Efficiency Max. Capacitive
Number Voltage Range Voltage Current typ (1) Load (2)
[VAC] [VDC] [mA] [%] [µF]
RAC05-05SK/480 85-528 5 1000 63 10000
RAC05-12SK/480 85-528 12 420 65 1200 C
O
M
C O N V ER
T
C
O
M
CO NVE R
T

E
E

RE
RE

R
R
ERP

S
S
RAC05-15SK/480 85-528 15 330 60 1000 RoHS 2 + REACH
compliant compliant compliant
10 from 10

Notes:

CO
CO

TS
TS
M M

C
C
PL U P U
IA N D LIA D
T PRO N T PRO

Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max Cap Load is tested at nominal input and full resistive load

Model Numbering

RAC05-__ _K/480
nom. Output Power Single
5003727
Output Voltage
IEC/EN62368-1 compliant
Ordering Examples: UL61010-1 certified
RAC05-05SK/480 5Vout Single Output CSA C22.2 No. 61010-1 certified
RAC05-12SK/480 12Vout Single Output
IEC/EN61010-1 certified
IEC/EN61204-3 compliant
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) EN55032 compliant
EN55014-1 compliant
BASIC CHARACTERISTICS EN55014-2 compliant
Parameter Condition Min. Typ. Max. EN55024 compliant
Internal Input Filter Pi type EN61000 compliant
CB Report
nom. Vin= 480VAC 85VAC 528VAC
Input Voltage Range (3,4)
120VDC 745VDC
100VAC 110mA
Input Current 400VAC 40mA
480VAC 35mA
400VAC 18A
Inrush Current cold start at +25°C
480VAC 20A
No load Power Consumption 500mW
Input Frequency Range AC Input 47Hz 63Hz
Minimum Load 0%
Notes:
Note3: The products were submitted for safety files at AC-Input operation
Note4: Refer to „Line Derating“
continued on next page

www.recom-power.com REV.: 7/2021 PA-1


RAC05-K/480
AC/DC Converter Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Parameter Condition Min. Typ. Max.
Power Factor 400VAC/480VAC 0.45
Start-up Time 25ms
Rise Time 20ms
100VAC 14ms
Hold-up Time 400VAC 150ms
480VAC 200ms
Internal Operating Frequency 130kHz
400VAC
Output Ripple and Noise (5) 20MHz BW 50mVp-p
480VAC

Notes:
Note5: Measurements are made with a 0.1μF MLCC & 10μF E-cap in parallel across output. (low ESR)

Efficiency vs. Load

RAC05-05SK/480 RAC05-12SK/480
100 100
90 90
80 80
70 70
Efficiency [%]

Efficiency [%]

60 60
50 50
40 40
30 230VAC 30 230VAC
400VAC 400VAC
20 20 480VAC
480VAC
10 10
0 0
0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100
Output Load [%] Output Load [%]

RAC05-15SK/480
100
90
80
70
Efficiency [%]

60
50
40
30 230VAC
400VAC
20 480VAC
10
0
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]

www.recom-power.com REV.: 7/2021 PA-2


RAC05-K/480
AC/DC Converter Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
REGULATIONS
Parameter Condition Value
Output Accuracy ±1.0% typ.
Line Regulation ±0.5% typ.
Load Regulation 10% to 100% load 1.0% typ.
25% load step change 4.0% max.
Transient Response
recovery time 500µs typ.

Deviation at 400/480VAC

RAC05-05SK/480 RAC05-12SK/480
1 1

0.5 0.5
Deviation [%]

Deviation [%]
0 0

-0.5 -0.5

-1 -1
0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100
Output Load [%] Output Load [%]

RAC05-15SK/480
1

0.5
Deviation [%]

-0.5

-1
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]

PROTECTIONS
Parameter Type Value
Input Fuse (6) external slow blow 600VAC, 2A
Limited Power Source (LPS) according to IEC62368-1 CB Report yes
Short Circuit Protection (SCP) below 100mW hiccup, automatic restart
Over Voltage Protection (OVP) 150% - 195%, hiccup mode
Over Voltage Category OVCIII
Over Current Protection (OCP) 150% - 195%, hiccup mode
Class of Equipment Class II

continued on next page

www.recom-power.com REV.: 7/2021 PA-3


RAC05-K/480
AC/DC Converter Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Parameter Type Value
Isolation Voltage (7)
I/P to O/P 1 minute 5.4kVAC
Isolation Resistance 1GΩ min.
Isolation Capacitance 100pF max.
Insulation Grade reinforced
Leakage Current 25µA max.

Protection Circuit (3,6) L


(L1) (L2)
N

F VACin (L, L1) +Vout


+Vout

VACin(N, L2) -Vout


-Vout
Notes:
Note6: An external fuse is mandatory in order to protect the device in addition on the AC input side. RECOM recommend: slow blow type, 600Vac, 2A.
Note7: For repeat Hi-Pot testing, reduce the time and/or the test voltage

ENVIRONMENTAL
Parameter Condition Value
full load -40°C to +60°C
Operating Temperature Range (8) @ natural convection 0.1m/s
refer to „Derating Graph (8)“ -40°C to +80°C
Maximum Case Temperature +100°C
Temperature Coefficient 0.05%/K
Thermal Impedance 0.1m/s airflow 16K/W
Operating Altitude according to 61010-1 5000m
Pollution Degree according to 61010-1 PD3
Operating Humidity non-condensing 5% - 95% RH max.
Vibration according to MIL-STD-202G 10-500Hz, 2G 10min./1cycle, 60min. each along x,y,z axes
+25°C 105 x 103 hours
Design Lifetime
+60°C 40 x 103 hours
+25°C >1726 x 103 hours
MTBF according to MIL-HDBK-217F, G.B.
+40°C >1585 x 103 hours
Derating Graph (8) Line Derating
(@ Chamber and natural convection 0.1m/s)

100 100
90 90
80 80
70 70
Output Load [%]
Output Load [%]

60 60
50 50
40 40
30 30
20 20
10 10
0 0
-40 -20 0 20 40 60 80 100 120 85 90 528
Ambient Temperature [°C] Input Voltage [VAC]
Notes:
Note8: The 12Vout and 15Vout were submitted for safety file (190415125GZU-001) for full load operation up to TAMB= +50°C only

www.recom-power.com REV.: 7/2021 PA-4


RAC05-K/480
AC/DC Converter Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Audio/video, information and communication technology equipment. IEC62368-1:2014 2nd Edition
Safety requirements (LVD) EN62368-1:2014 + A11:2017
Safety requirements for electrical equipment for measurement, control and UL61010-1, 3rd Edition 2012
190415122GZU-001
laboratory use - Part 1: General requirements CSA C22.2 No. 61010-1, 3rd Edition:2012
Safety requirements for electrical equipment for measurement, control and
EN61010-1:2010
laboratory use - Part 1: General requirements
190415125GZU-001
Safety requirements for electrical equipment for measurement, control and
IEC61010-1:2010 + A1:2016 3rd Edition
laboratory use - Part 1: General requirements (CB Scheme)
EAC RU-AT.03.67361 TP TC 004/020, 2011
RoHS2 RoHS-2011/65/EU + AM-2015/863

EMC Compliance Condition Standard / Criterion


Low-voltage power supplies DC output - Part 3: Electromagnetic compatibility IEC/EN61204-3:2018, Class B
Electromagnetic compatibility of multimedia equipment – Emission Requirements (9) EN55032:2015, Class B
Electromagnetic compatibility of household appliances, electric tools and similar
EN55014-1:2006+A2:2011
apparatus - Emission Requirements
LCS180508025BE
Information technology equipment - Immunity characteristics -
EN55024:2010+A1:2015
Limits and methods of measurement
Electromagnetic compatibility of household appliances, electric tools and similar
EN55014-2:2015
apparatus - Immunity Requirements
Air: ±2, 4, 8, 15kV,
ESD Electrostatic discharge immunity test EN61000-4-2: 2009, Criteria A
Contact: ±2, 4, 6, 8kV
10V/m, 80MHz-1GHz
Radiated, radio-frequency, electromagnetic field immunity test 3V/m, 1.5GHz-2GHz EN61000-4-3: 2006 + A1:2009, Criteria A
1V/m, 2GHz-2.7GHz
AC In Port: ±2.0kV (5-100kHz) EN61000-4-4:2012, Criteria A
Fast Transient and Burst Immunity
DC Out Port: ±2.0kHz EN61000-4-4:2012, Criteria B
AC IN Port: L-N ±0.5, 1, 2, 4kV EN61000-4-5:2019, Criteria A
Surge Immunity
DC Out Port: ±0.5kV EN61000-4-5:2014+A1:2017, Criteria B
Immunity to conducted disturbances, induced by radio-frequency fields 10Vrms EN61000-4-6:2014, Criteria A
Power Magnetic Field Immunity 50Hz, 30A/m EN61000-4-8:2010, Criteria A
Voltage Dips 100% EN61000-4-11:2004+A1:2017, Criteria B
Voltage Dips 60% EN61000-4-11:2004+A1:2017, Criteria C
Voltage Dips and Interruptions Voltage Dips 30% EN61000-4-11:2004+A1:2017, Criteria C
Voltage Dips 20% EN61000-4-11:2004+A1:2017, Criteria C
Voltage Interruptions > 95% EN61000-4-11:2004+A1:2017, Criteria C
Limits of Voltage Fluctuations & Flicker EN61000-3-3:2013
Notes:
Note9: If output is connected to GND, please contact RECOM tech support for advice

DIMENSION AND PHYSICAL CHARACTERISTICS


Parameter Type Value
case black plastic, (UL94 V-0)
potting polyurethane, (UL94 V-0)
Material
PCB FR4, (UL94 V-0)
baseplate plastic, (UL94 V-0)
Dimension (LxWxH) 52.5 x 27.4 x 23.0mm
Weight 58g typ.

continued on next page

www.recom-power.com REV.: 7/2021 PA-5


RAC05-K/480
AC/DC Converter Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)

Dimension Drawing (mm)


52.5

embossed logo

27.4
Pin Connections
Pin # Single
51.5 26.3 1 VAC in (N) (L2)
2 VAC in (L) (L1)
3 -Vout
4 +Vout
23.0

Tolerance: xx.x= ±0.5mm


xx.xx= ±0.25mm

Ø1.0 +0.15/-0.05
6.0 ±1.0

20.32

Recommended Footprint Details

2 1 4

Bottom View 3 Top View 3


2. 54
10.16
3.50

1 4 2

3.39 18x2.54= 45.72 2.54

INSTALLATION AND APPLICATION


Phase to Phase Application Standard L to N Application
L1 L2 L3 L N
F IC1 F
IC1
VACIN (L) VACIN (L)
+VOUT +VOUT

VACIN (N) VACIN (N)


-VOUT -VOUT

Phase Redundancy B6U Application


L1 L2 L3
IC1
F D0 D1 D2 +VOUT
VACIN (L)
F

F VACIN (N)

-VOUT
D3 D4 D5

www.recom-power.com REV.: 7/2021 PA-6


RAC05-K/480
AC/DC Converter Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
PACKAGING INFORMATION
Parameter Type Value
Packaging Dimension (LxWxH) tube 490.0 x 56.0 x 40.0mm
Packaging Quantity 15pcs
Storage Temperature Range -40°C to +85°C
Storage Humidity non-condensing 20% to 90% RH max.

The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.

www.recom-power.com REV.: 7/2021 PA-7

You might also like