Pressure sensor
SPAN-P10R-G18M-PNLK-PNVBA-L1
Part number: 8035533
General operating condition
Data sheet
Feature Value
Symbol 00995685
Certification RCM compliance mark
c UL us - Listed (OL)
CE marking (see declaration of conformity) As per EU EMC directive
As per EU RoHS directive
UKCA marking (see declaration of conformity) To UK instructions for EMC
To UK RoHS instructions
Certificate issuing authority UL E322346
Note on materials RoHS-compliant
Measured variable Relative pressure
Method of measurement Piezoresistive pressure sensor
Pressure measuring range initial value 0 MPa
Pressure measuring range initial value 0 bar
Pressure measuring range initial value 0 psi
Pressure measuring range end value 1 MPa
Pressure measuring range end value 10 bar
Pressure measuring range end value 145 psi
Max. overload pressure 15 bar
Overload pressure 1.5 MPa
Overload pressure 15 bar
Overload pressure 217.5 psi
Operating medium Compressed air as per ISO 8573-1:2010 [7:4:4]
Inert gas
Information on operating and pilot media Operation with oil lubrication possible
Temperature of medium 0 °C ... 50 °C
Ambient temperature 0 °C ... 50 °C
Accuracy in ± % FS 1.5 %FS
Repetition accuracy in ± %FS 0.3 %FS
Temperature co-efficient in ± %FS/K 0.05 %FS/K
Switching output 2 x PNP or 2 x NPN switchable
Switching function Window comparator
Threshold value comparator
Auto difference monitoring
Switching element function N/C contact/N/O contact switchable
Max. output current 100 mA
3/8/24 - Subject to change - Festo SE & Co. KG 1/3
Feature Value
Analog output 0 - 10 V
4 - 20 mA
1-5V
Max. load resistance of current output 500 Ohm
Min. load resistance of voltage output 20 kOhm
Short-circuit protection yes
Protocol IO-Link®
IO-Link®, protocol version Device V 1.1
IO-Link®, profile Smart sensor profile
IO-Link®, function classes Binary data channel (BDC)
Process data variable (PDV)
Identification
Diagnostics
Teach channel
IO-Link®, communication mode COM2 (38,4 kBd)
IO-Link®, SIO mode support Yes
IO-Link®, port class A
IO-Link®, process data width OUT 0 Byte
IO-Link®, process data width IN 2 Byte
IO-Link®, process data content IN 14 bit PDV (pressure measurement)
2 bit BDC (pressure monitoring)
IO-Link®, minimum cycle time 3 ms
IO-Link®, data memory required 500 byte
DC operating voltage range 15 V ... 30 V
Reverse polarity protection for all electrical connections
Electrical connection 1, connection type Plug
Electrical connection 1, connection technology Connection diagram L1J
Electrical connection 1, number of pins/wires 4
Electrical connection for input 1, connection pattern 00995428
Type of mounting Front panel mounting
With thread
With wall/surface bracket
Mounting position Any
Pneumatic connection External thread G1/8
Internal thread M5
Product weight 46 g
Housing material PA-reinforced
Materials in contact with the media FPM
High-alloy stainless steel
Display type Illuminated LCD
Displayable unit(s) MPa
bar
inH2O
inHg
kPa
kgf/cm²
mbar
mmHg
psi
Setting options IO-Link®
Teach-in
Via display and pushbuttons
Protection against tampering IO-Link®
PIN code
Setting range threshold value 0 % ... 100 %
Setting range hysteresis 0 % ... 90 %
Degree of protection IP40
Corrosion resistance class (CRC) 2 - Moderate corrosion stress
LABS (PWIS) conformity VDMA24364-B1/B2-L
3/8/24 - Subject to change - Festo SE & Co. KG 2/3
Feature Value
Suitability for the production of Li-ion batteries Metals with more than 1% copper, zinc or nickel by mass are excluded
from use. Exceptions are nickel in steel, chemically nickel-plated
surfaces, printed circuit boards, cables, electrical plug connectors and
coils
Cleanroom class Class 4 according to ISO 14644-1
3/8/24 - Subject to change - Festo SE & Co. KG 3/3