Modular Lube® Lubrication Systems
System Controls
                  Model 84501 Program Timer—Solid State
                  Designed to control the lubrication cycle frequency of air-operated single-stroke
                  pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way
                  air solenoid valve (not included) installed in the air line to pump.
                         Off Time                      On Time
                       (Cycle Time)                (Pumping Time)                    Power     Approvals                   Switch
                                                                                  Requirements                            Capacity
                     Min         Max                Min        Max
                                                              1 Min.                  120/230 VAC                 120 VAC, 5 Amps
                   20 Sec.         24 Hrs.        10 Sec.    24 Sec.                    50/60 Hz         UL, CSA 230 VAC, 1.5 Amps
                     Built-In Program Options                                   Enclosure                       Ambient Operating
                                                                                                                Temperature Range
                  3 Hr. Program          Prelube                             Dimensions-in./mm
                                                               Rating                                          Minimum Maximum
                     Memory              Function                         Height Width Depth
                    Yes       No        Yes         No         NEMA #1         8¹⁄₄        6¹³⁄₁₆    4¹⁵⁄₁₆       0°F           130°F
                                                                               210         173       125         -18°C          54°C
                  Note:
                   Refer to Technical Manual for a full explanation of available program options.
                  Model 84511 Economy Timer for
                  Single Stroke Pumps
                  Uses a timing motor, cam and Micro-Switch to turn pump off and on. NEMA 1
                  enclosure, UL and CSA listed. Switch capacity 10 amps non-inductive.
                         Off Time                     On Time
                       (Cycle Time)                (Pumping Time)                    Power     Approvals                   Switch
                                                                                  Requirements                            Capacity
                      Min        Max                Min      Max
                     5 Min.      1 Hr.            30 Sec.   90 Sec.               120 VAC, 60 Hz         UL, CSA          10 Amps
                  Note: Off-time selectable in 5 minute intervals.
                                   Enclosure
                                       Dimensions - in. / mm
                   Rating
                                    Height    Width        Depth
                  NEMA 1           5 / 127       3¹⁄₄ / 82.5       3¹⁄₂ / 89
                  Flow Meter
                  Flow meter measures and records oil flow to the system.
                                                                                                              Max. Pressure Rating
                      Model                      Register                       Oil Inlet/Outlet                   psig / bar
                      87806                  200 counts per pint                      ¹⁄₄" NPTF(F)                 6000 / 408
                  Cycle Monitors
                  Cycle Monitors monitor and record oil flow volume delivered to lube points and
                  signal fault if flow stops or diminishes significantly.
                                                                            Max.
                              System(s)         Electrical Power           Display            Alarm Time             3rd Party
                   Model
                              Monitored          Requirements              Record                                    Approvals
                                                                            pints             Min.   Max.
                    87610           1           115 VAC, 50-60 Hz                             37.5    10        CSA Class I, Group D
                                                                           999,999
                    87611           2                24 VDC                                   Sec.   Min.      Class II, Group E, F & G
26
Modular Lube® Lubrication Systems
System Controls
                  Model 84015 Timer—12-24V DC
                  Solid-state microprocessor-based controller for automated lubrication systems on
                  mobile equipment or where AC power is not available. Rugged construction with
                  liquid- and dust-tight enclosure. Includes manual push-button for remote initiation
                  of a lube cycle.
                              Off Time**
                             (Cycle Time)                            Fixed On Time                 Power                     Switch
                                                                    (Pumping Time)              Requirements                Capacity
                         Min.             Max.
                                                                                                 10-30 VDC
                      2.5 Min.                  80 Min.                   75 Sec.                                               5 Amps
                                                                                                  25 MA*
                  * Less load.
                  ** Available selections are 2.5, 5, 10, 20, 40 or 80 minutes.
                                             Enclosure                                      Ambient Operating Temperature Range
                                               Dimensions-in. / mm
                      Rating                                                                    Minimum                     Maximum
                                           Height    Width      Depth
                     NEMA 12
                                         5¹⁄₄ / 133         3¹⁄₈ / 79         3 / 76            0°F / -18°C                131°F / 55°C
                  Model 85530 Lubrication System Controller
                  Controls lubrication frequency, master divider valve cycle and monitors supply line
                  pressure. The LCD displays operating status.
                                         Lube Cycle
                                                                                                    Max.              Pumping Time
                          Timer Mode                Counter Mode
                             Off Time                Off Counts                                    Count              Before Alarm
                        Min.          Max.        Min.         Max.                                Rate*           Min.               Max.
                                                                                                   30/Sec.
                         1           .      9,900                 1                    99,000      @ 50%            1                 99
                       Minute              Minutes               Count                 Counts     Duty Cycle      Minute            Minutes
                  * Minimum duration of count signal is 33 milliseconds.
                     Power Requirements (less load)                        Pump,             Ambient                     Enclosure
                                                                          Solenoid,        Temperature                  Dimensions-in. / mm
                           Voltage                    Current             or Alarm            Range            Rating
                                                                                                                        Height Width Depth
                                                                          Capacity
                    120 VAC, 50/60 Hz                 85 MA
                                                                            360 VA          32° to 122°F       NEMA      9¹⁄₂     8¹⁵⁄₁₆     4¹⁄₈
                    230 VAC, 50/60 HZ                  45 MA
                                                                                            -0° to +50° C       12       241      227        105
                         24 VDC                       250 MA               5 Amps
                  Notes: Model 85530 is CSA/NRTL approved.
                                                                                                                                              27
Modular Lube® Lubrication Systems
System Controls
                  Model 85500 System Sentry II
                  The ultimate automated lubrication system controller/monitor now features greater
                  monitoring accuracy with less sensitivity to lubricant flow rates, feed line length or
                  bearing back-pressure. System Sentry II is always on the job, making sure that every
                  lube point is lubricated when it’s supposed to be.
                  • Solid-state controller with LCD status display and 16-button keypad for
                    system programming
                  • Controls up to two pumps with as many as two lube zones per pump
                  • Fully programmable monitoring and alarm functions
                  • Be set up to monitor every lube point for lubricant flow during each lubrication event
                  • Easy to understand prompts reported by simple English language messages in real time
                  Some functions require optional accessories. See chart on page 30. Use a
                  maximum or 48 sensors and three accessory Sensor Boards (order separately—
                  16 sensors per board) to monitor lube points. For more than 48 sensors, use
                  Model 85510 Satellite plus additional Sensor Boards for a maximum of 1536 lube points.
                                      Lube Cycle
                                                                                        Max.      Pumping Time
                        Timer Mode               Counter Mode
                           Off Time                Off Counts                          Count      Before Alarm         Net
                      Min.          Max.        Min.        Max.                       Rate*      Min.         Max.    Wt.
                       1             9,900               1             99,000         30/Sec.       1        99    18 lbs.
                     Second         Minutes             Count          Counts         @ 50%       Second   Minutes 8.1 kg
                                                                                     Duty Cycle
                  * Minimum duration of count signal is 33 milliseconds.
                   Power Requirements (less load)                Pump,        Ambient            Enclosure
                                                                Solenoid,   Temperature        Dimensions-in. / mm
                        Voltage               Current           or Alarm       Range    Rating
                                                                                               Height Width Depth
                                                                Capacity
                    120 VAC, 50/60 Hz         250 MA*
                                                                 360 VA         32° to 122°F   NEMA      16      14     4⁷⁄₈
                    230 VAC, 50/60 HZ         125 MA*
                                                                                 0° to 50° C    12       241     227    105
                         24 VDC               600 MA*            5 Amps
                  Note: Model 85500 is CSA/NRTL approved.
                  * No external load, no sensors.
                  Model 243100 Sensor Wire
                  100 foot (30.5 meters) coil of two conductor 22-gauge wire for connecting sensors to
                  monitor. Maximum length of wire between sensor and monitor is 500 feet (152 meters).
28
Modular Lube® Lubrication Systems
System Controls
                  Model 247333 Pressure Transducer
                  Pressure Transducer signals actual system pressure via LCD display of System
                  Sentry II. Comes with 72 inch (1.8m) shielded 24-gauge connecting wire. Maximum
                  length of wire between transducer and monitor is 30 (9.1m) feet.
                                                    Pressure         Ambient                  Voltage
                   Range Accuracy         Proof                                                                     Enclosure
                                                   Connection         Temp.         Input     Output       Offset
                                                                                                                    NEMA 4X
                     0 to               7500 psig ¹⁄₄" NPT   -20° to 180° F          10 to       1-6        1         Rating
                              ±1%
                   4000 psi              517 bar Male Thread -29° to 82° C            30        VDC        VDC      300 Series
                   276 bar                                                           VDC                             Stainless
                                                                                                                       Steel
                  Model 250365 Sensor Board
                  Plug-in accessory board used with Model 85500 that allows the attachment of up
                  to 16 lube flow sensors. Model 85500 comes without boards installed and can hold
                  up to a total of three.
                  Sensor Assemblies
                  Sensor assemblies consist of a check body and lube sensor with attached 30'
                  cable. Cables are epoxy potted into the sensors for a watertight seal. Sensors have
                  a ³⁄₈" pipe thread for conduit connection and a Viton® O-ring seal. Check bodies
                  terminate in a ¹⁄₈" NPTF male thread for attachment to a bearing or other lubricant
                  inlet. Maximum working pressure 6,000 psi (414 bar). Maximum wire run from
                  sensor to monitor is 500 feet (152m).
                                                                                                            Min. Interval
                                                                      Lubricant        Min. Flow
                   Model      Description         Construction                                             Between Lube
                                                                    Temp. Range        Per Event            Flow Event
                              Straight Sensor
                   250400                                                           .004 cu. in./.066 cc
                                 Assembly         Brass Sensor
                                                  & Plated Steel                      @ 32°F /0°C to
                                90° Sensor                                             125°F/52°C
                   250490                          Check Body       32° to 145° F
                                 Assembly
                                                                     0° to 63° C                             30 Seconds
                              Straight Sensor       Sensor &
                   250500                                                           .008 cu. in./.131 cc
                                 Assembly          Check Body
                                                                                    @ 126°F to 145°F
                                90° Sensor              316                           (53°C to 63°C)
                   250590
                                 Assembly         Stainless Steel
                                                                                                                          29
Modular Lube® Lubrication Systems
System Controls
                  Use This Guide to Select Accessories for
                  Model 85500 System Sentry II
                                                  Pressure              Sensor                            Sensor Wire
                            Function               Switch                Board            Sensors        #243100 (100')
                                                  #69630               #250365             Note 2             Note 3
                   Lube Controller
                   1 Pump, 1 Zone                 Optional 1               —                  —                 —
                   Note 1
                   Lube Controller,
                   1 Pump,                        Optional 1               —                  —                 —
                   Up to 3 Zones
                   Lube Controller,
                   2 Pumps, 1 Zone                Optional 1               —                  —                 —
                   Per Pump
                   Lube Controller,
                   2 Pumps, Up to 2               Optional 1               —                  —                 —
                   Zones Per Pump
                   Lube Point                                           Required           Required          Required
                   Monitoring                         —                1 per each           1 per            Quantity
                   ≤ 48 Points                                         16 Sensors         Lube Point        As Needed
                   Lube Point                                           Required           Required          Required
                   Monitoring                         —                1 per each           1 per            Quantity
                   > 48 ≤ 1536 Points                                  16 Sensors         Lube Point        As Needed
                  Note 1: Controller may be operated without a pressure switch. Pressure switch may be used to
                         monitor supply line pressure.
                  Note 2: Sensors include 30' (9.1m) cable pigtail. Select brass/plated steel or stainless steel sensors in
                         straight or 90° configuration as required.
                  Note 3: Maximum distance between monitor and sensor is 500' (152 meters).
30
Modular Lube® Lubrication Systems
System Controls
                  Electric Solenoid-Operated Air Valves
                                  Electrical Characteristics
                  Model Type       Power        Inrush Holding Air        Ambient     Cv     Max.    Conduit
                               Requirements Current Current Inlet/      Temperature Factor Pressure Connection
                                                Amps Amps Outlet           Range           psi / bar
                               110 VAC, 50 Hz
                  350244       120 VAC, 60 Hz .11          .07
                                    8.4 VA                               0° to 120°F
                         4-Way                                                         1.2
                               220 VAC, 50 Hz                           -18° to 49°C
                  350245       240 VAC, 60 Hz .055        .035
                                    8.4 VA                      1
                                                                 ⁄4"                                     1
                                                                                                          ⁄2" NPS(F)
                               110 VAC, 50 Hz                  NPT(F)
                  350241       120 VAC, 60 Hz .11          .07
                                    8.4 VA                                                       150
                               220 VAC, 50 Hz                                                    10.3
                  350242       240 VAC, 60 Hz .055        .035                         .18
                         3-Way      8.4 VA
                                   12 VDC                                0° to 140°F
                  350282
                                   6 Watts                      1
                                                                 ⁄8"    -18° to 60°C
                                                  N/A     N/A                                                  N/A
                                   24 VDC                      NPT(F)
                  350283
                                   6 Watts
                                 120V, 60 Hz                    3
                                                                 ⁄8"
                   68586 2-Way      12 VA          .2       .1 NPT(F)                  2.4               1
                                                                                                          2  ⁄ " NPT(F)
                  274398 3-Way     24 VDC         N/A     N/A
                                                                1
                                                                  ⁄4"                    .5                    N/A
                                  8.5 Watts                    NPT(F)
                               110 VAC, 50 Hz                   3
                                                                 ⁄8"     0° to 120°F
                  244727 3-Way 120 VAC, 60 Hz .12          .09 NPT(F)                  4.4               1
                                                                                                             ⁄2" NPT(F)
                                                                        -18° to 49°C
                                    11 VA
                  Model 83354 Signal Monitor
                  Designed to provide visual and audible indication of system operation and failure.
                  Utilizes signal from system controller. Includes model 69606 Alarm Horn mounted
                  on enclosure door.
                                                   Indicator Lamps                            Dimensions - in / mm
                        Power                                                  Audible
                      Requirement          Power        Lube     System                       Height Width Depth
                                            On       System On Failure         Alarm
                         115 VAC
                         50/60 Hz          Green       Amber       Red       69606 Horn         10       8          6
                          35 VA                                               (included)       254      203        152
                                                                                                                     31