You are on page 1/ 19

SDS3000X HD %

Series

Digital Storage
Oscilloscope

Data Sheet
EN01A

2022.02
Key Features
4 analog channels, up to 1 GHz bandwidth with up to
4GSa/s sample rate

SDS3104X HD 12-bit ADC


Low background noise: 125 μVrms @ 1 GHz bandwidth
SDS3054X HD SPO technology
 Waveform capture rates up to 200,000 wfm/s in
SDS3034X HD Normal mode and 890,000 wfm/s in Sequence
mode
 Supports 256-level intensity grading and color
temperature display modes
 Up to 400 Mpts/ch record length
 Digital trigger system
Intelligent trigger: Edge, Slope, Pulse, Window, Runt,
Interval, Dropout, Pattern, Qualified, Nth edge,
Setup/hold, Delay and Video (HDTV supported). Zone
Trigger simplifies advanced triggering
Product Overview
Serial bus triggering and decoder, supports protocols I2C,
SIGLENT’s SDS3000X HD series Digital Storage SPI, UART, CAN, LIN, CAN FD, FlexRay, I2S, MIL-STD-
Oscilloscopes are available in bandwidths of 1 GHz, 500 MHz 1553B, SENT, Manchester and ARINC429
and 350 MHz, have 12-bit ADCs with sample rate up to Segmented acquisition (Sequence) mode, dividing the
4GSa/s, maximum record length of 400 Mpts/ch, and display maximum record length into multiple segments (up to
up to 4 analog channels + 16 digital channels for high 80,000), according to trigger conditions set by the user,
performance mixed signal analysis. with a very small dead time between segments to capture
the qualifying event
The SDS3000X HD series employs Siglent’s SPO technology History waveform record (History) function, the maximum
with a maximum waveform capture rate of up to 200,000 wfm/ recorded waveform length is 80,000 frames
s, 256-level intensity grading display function plus a color Automatic measurements on 50+ parameters, supports
temperature display mode. It also employs an innovative digital statistics with histogram, track, trend, Gating
trigger system with high sensitivity and low jitter. The trigger measurement, and measurements on Math, History and
system supports multiple powerful triggering modes including Memory traces
serial bus triggering. Tools such as History waveform
4 Math traces (4 Mpts FFT, Filter, addition, subtraction,
recording, Search and Navigate functions, Mask Test, Bode
multiplication, division, integration, differential, square
Plot and Power Analysis allow for extended waveform records
root, etc.), supports formula editor
to be captured, stored, and analyzed. An impressive array of
measurement and math capabilities, options for a 50 MHz Abundant data analysis functions such as Search,
arbitrary waveform generator, as well as serial decoding are Navigate, Digital Voltmeter, Counter, Waveform
also features of the SDS3000X HD . Histogram, Bode plot and Power Analysis
High Speed hardware-based Average, ERES; High
Speed hardware-based Mask Test function, with Mask
The large 10.1’’ display capacitive touch screen supports multi-
Editor tool for creating user-defined masks
touch gestures, with the addition of user-friendly UI design, can
greatly improve the operational efficiency. It also supports 16 digital channels (optional)
mouse control, and remote web control over LAN. External 50 MHz waveform generator (optional)
Large 10.1” TFT-LCD display with 1024 * 600 resolution;
Capacitive touch screen supports multi-touch gestures
Interfaces include: 2x USB 3.0 Host,1x USB 2.0 Host ,
USB 3.0 Device (USBTMC) , 1000M LAN ((VXI-
11/Telnet/Socket/LXI)), External Triger In, Aux Out
(Pass/Fail, Trigger Out)
Built-in web server supports remote control over the LAN
port using a web browser. Supports SCPI remote control
commands. Supports external mouse and keyboard

INT.SIGLENT.COM 1
SDS3000X HD Series Digital Storage Oscilloscope

Models and Key Specifications


Model SDS3104X HD SDS3054X HD SDS3034X HD
Analog channels 4 + EXT
1 GHz (800 MHz in non-interleaving 500 MHz
Bandwidth 350 MHz
mode)
Sample rate 4 GSa/s (interleaving mode), 2 GSa/s (non-interleaving mode)
(Max.)
Memory depth 400 Mpts/ch (interleaving mode: single-channel), 200 Mpts/ch (interleaving mode: dual-channel), 100 Mpts/ch
(Max.) (non-interleaving mode)
Waveform Normal mode:200,000 wfm/s;
capture rate
(Max.) Sequence mode:890,000 wfm/s
Vertical
12-bit. Up to 16-bit in ERES mode
resolution
Edge, Slope, Pulse width, Window, Runt, Interval, Dropout, Pattern, Video, Qualified, Nth edge, Setup/hold,
Trigger type
Delay, Serial
Serial trigger and Standard: I2C, SPI, UART, CAN, LIN
decode Optional: CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT, Manchester (decode only), ARINC429
Measurement 50+ parameters, statistics, histogram, trend, and track supported
4 traces
Math 4 Mpts FFT, +, -, x, ÷, ∫dt, d/dt, √, Identity, Negation, Absolute, Sign, ex, 10x, ln, lg, Interpolation, MaxHold,
MinHold, ERES, Average, Filter. Supports formula editor
Search, Navigate, History, Mask Test, Digital Voltmeter, Counter, Waveform Histogram, Bode plot, and Power
Data analysis
Analysis
Digital channel
16-channel; maximum sample rate up to 1 GSa/s; record length up to 100 Mpts
(optional)
Waveform
generator Single-channel SAG1021I, frequency up to 50 MHz, 125 MSa/s sample rate, 16 kpts waveform memory
(optional)
USB 3.0 Host x2, USB 2.0 Host x1, USB 3.0 Device, 10M/100M/1000M LAN, External trigger, Auxiliary output
I/O
(TRIG OUT, PASS/FAIL)
Probe
One 500 MHz passive probe supplied for each channel
(Standard)
Display 10.1 TFT-LCD with capacitive touch screen (1024*600)

2 INT.SIGLENT.COM
SDS3000X HD Series Digital Storage Oscilloscope

Functions & Characteristics

12-bit High Resolution

8-bit 12-bit
12-bit resolution shows you more details and less noise on the waveform.

12-bit

Low noise floor: 125 µVrms at 1 GHz bandwidth 0.5% DC gain accuracy

Excellent User Interface and User Experience

 10.1” display with 1024x600 resolution


 Capacitive touch screen, supporting multi-touch
gestures, can move or scale the waveform
traces quickly by finger-touch movements,
which greatly improves the operation efficiency
 Built-in WebServer supports remote control on a
web page over LAN
 Supports external mouse and keyboard

INT.SIGLENT.COM 3
SDS3000X HD Series Digital Storage Oscilloscope

High Waveform Update Rate Deep Record Length

With a waveform update rate of up to 200,000 wfm/s, the Using hardware-based Zoom technique and record length of up
oscilloscope can easily capture unusual or low-probability to 400 Mpts, users can select a slower timebase without
events. In Sequence mode, the waveform capture rate can compromising the sample rate, and then quickly zoom in to
reach 890,000 wfm/s focus on the area of interest

Multiple Trigger Functions Zone Trigger

Edge, Slope, Pulse, Video, Windows, Runt, Interval, Dropout, Zone Trigger is available for advanced triggering. Combine
Pattern, Qualified, Nth edge, Setup/hold, Delay and serial spatial triggering with common trigger modes to isolate signals
trigger of interest

4 INT.SIGLENT.COM
SDS3000X HD Series Digital Storage Oscilloscope

Advanced Math Function Deep Memory FFT

In addition to the traditional (+, -, X, /) operations, FFT, Filter, FFT supports up to 4 Mpts operation. This provides high-
integration, differential, square root, and more are supported. frequency resolution with a fast refresh rate. The FFT function
Formula Editor is available for more complex operations. 4 math also supports a variety of window functions so that it can adapt
traces are available. to different spectrum measurement needs. Three modes
(Normal, Average, and Max hold) can satisfy different
requirements for observing the power spectrum. Auto peak
detection and markers are supported.

Measurements of a Variety of Parameters Parameter Statistics Function

Statistics show the current value, maximum value, minimum


value, standard deviation, and mean value of up to 12
parameters simultaneously. A histogram is available to show the
Parameter measurements include 4 categories: horizontal, probability distribution of a parameter. Trend and Track are
vertical, miscellaneous, and CH delay providing a total of 50+ available to show the parameter value vs. time.
different types of measurements. Measurements can be
performed within a specified gate period. Measurements on For horizontal parameters such as period, all results are
Math, Reference, and History frames are supported extracted from a frame, instead of just calculating the first one.
This accelerates statistics on horizontal measurements and
enables distribution observation in a frame using Histogram and
Track

INT.SIGLENT.COM 5
SDS3000X HD Series Digital Storage Oscilloscope

History Mode Sequence Mode

History function can record up to 80,000 frames of waveforms. Segmented memory collection will store the waveform into
The recording is executed automatically so that the customer multiple memory segments (up to 80,000) and each segment
can playback the history waveforms at any time to observe will store a triggered waveform as well the dead time
unusual events and quickly locate the area of interest using the information. The interval between segments can be as small as
cursors or measurements. The failed frames of the Mask Test 1.12 μs. All of the segments can be played back using the
can be stored as history History function

Search and Navigate Serial Bus Decode

The oscilloscope can search events specified by the user in a Display the decoded characters through the events list. Bus
frame. Events flagged by the Search can be recalled protocol information can be quickly and intuitively displayed in
automatically using Navigate. It can also navigate by time (delay tabular form. I2C, SPI, UART, CAN, LIN, CAN FD, FlexRay, I2S,
position) and history frames MIL-STD-1553B, SENT, Manchester and ARINC429 are
supported

6 INT.SIGLENT.COM
SDS3000X HD Series Digital Storage Oscilloscope

Hardware-based High Speed Mask Test Function

The oscilloscope utilizes a hardware-based Mask Test function, Built-in Mask Editor application helps to create custom masks
performing up to 28,000 Pass / Fail decisions each second. It is
easy to generate user-defined test templates to provide trace
mask comparisons, making it suitable for long-term signal
monitoring or automated production line testing

Bode Plot Power Analysis (Optional)

The oscilloscope can control the SIGLENT isolated USB AWG The Power Analysis option provides a full suite of power
module or a stand-alone SIGLENT SDG generator, to scan the measurements and analysis, which greatly improve the
amplitude and phase-frequency response of the DUT, and measurement efficiency in switching power supplies and power
display the data as a Bode Plot. This makes it possible to devices design
replace expensive network analyzers in some applications

INT.SIGLENT.COM 7
SDS3000X HD Series Digital Storage Oscilloscope

Digital Channels / MSO (Optional) 50 MHz Function/Arbitrary Waveform Generator


(Optional)

Four analog channels plus 16 digital channels enable users to The oscilloscope can control the SAG1021I waveform
acquire and trigger the waveforms then analyze the pattern, generator to output a waveform with up to 50 MHz frequency
simultaneously with one instrument and ±3 V amplitude. Six basic waveforms plus multiple types of
arbitrary waveforms are built-in

8 INT.SIGLENT.COM
SDS3000X HD Series Digital Storage Oscilloscope
Specifications
All specifications are not guaranteed unless the following conditions are met:
• The oscilloscope calibration period is current
• The oscilloscope has been working continuously for at least 30 minutes at the specified temperature (18℃ ~ 28℃)

Acquire (analog)
Sample rate 4 GSa/s (interleaving mode* 1),2 GSa/s (non-interleaving mode* 2 )
400 Mpts/ch (interleaving mode, single-channel), 200 Mpts/ch (interleaving mode, dual-channel), 100
Memory depth* 3 *4
Mpts/ch (non-interleaving mode)
Memory
management Auto, Fixed sample rate, Fixed memory length
mode
Waveform update Normal mode:up to 200,000 wfm/s
rate Sequence mode:up to 890,000 wfm/s
Intensity grading 256-level
Peak detect 0.5 ns
Average 4, 16, 32, 64, 128, 256, 512, 1024, 2048, 4096, 8192
ERES Enhanced bit: 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4 bits
Sequence Up to 80,000 segments, interval between triggers = 1.12 μs min.
History Up to 80,000 frames
Interpolation sinx/x, x
* 1: Interleaving mode: only one of C1/C2 and/or only one of C3/C4 activated
* 2: Non-interleaving mode: both C1/C2 and/or both C3/C4 activated
* 3: In Average and ERES modes, the memory depth is 20 Mpts/ch (interleaving mode), 10 Mpts/ch (non-interleaving mode)
* 4: single-channel: only one channel is active; dual-channel: one of C1/C2 and one of C3/C4 activated;

Vertical
SDS3104X HD SDS3054X HD SDS3034X HD
(analog)
Channel 4 + EXT
Bandwidth Interleaving mode:1 GHz
500 MHz 350 MHz
(-3 dB) @ 50 Ω Non-interleaving mode:800 MHz

Rise time@50 Ω Interleaving mode:450 ps


610 ps 830 ps
(typical) Non-interleaving mode:570 ps
Bandwidth
500 MHz 500 MHz 350 MHz
(-3 dB) @ 1M Ω
Hardware Bandwidth limit:
Bandwidth limit 20 MHz: 20 MHz (±20%)
200 MHz: 200 MHz (±20%)
Resolution 12-bit
ENOB *1 (typical) 8.2-bit 8.4-bit 8.5-bit
Noise floor*2 (rms,
@50 Ω, typical,1 125 μV 90 μV 70 μV
mV/div)
Range 8 divisions
1 MΩ: 0.5 mV/div – 10 V/div
50 Ω: 0.5 mV/div – 1 V/div
1 MΩ: 0.5 mV/div – 10 V/div
Vertical scale
(probe 1X) 2 μV/div – 10 V/div (Zoom mode)
50 Ω: 0.5 mV/div – 1 V/div
2 μV/div – 1 V/div (Zoom mode)
0.5 mV/div ~ 4.95 mV/div: ±1.5 %;
DC gain accuracy
5 mV/div ~ 10 V/div: ±0.5 % typical, ±1.0 % maximum;
Offset accuracy ± (1% of the offset setting + 0.5% of full scale + 0.02% maximum offset + 1 mV)
1 MΩ: 0.5 mV/div ~ 5 mV/div: ±1.6 V; 50 Ω: 0.5 mV/div ~ 5 mV/div: ±1.6V;
5.1 mV/div ~ 10 mV/div: ±4 V; 5.1 mV/div ~ 10 mV/div: ±4 V;
Offset range 10.2 mV/div ~ 20 mV/div:±8 V; 10.2 mV/div ~ 20 mV/div:±8 V;
(probe 1X) 20.5 mV/div ~ 100 mV/div: ±16 V; 20.5 mV/div ~ 1 V/div: ±10 V
102 mV/div ~ 200 mV/div: ±80 V;
205 mV/div ~ 1 V/div: ±160 V;

INT.SIGLENT.COM 9
SDS3000X HD Series Digital Storage Oscilloscope
1.02 V/div ~ 10 V/div: ±400 V
Low frequency
response (AC 6 Hz (typical)
coupling -3 dB)
Overshoot (100
mV/div, 150 ps
18% 10% 7%
edge @50 Ω,
typical)
Coupling DC, AC, GND
1 MΩ: (1 MΩ±2%) || (15 pF±3 pF)
Impedance
50 Ω: 50 Ω±1%
Max. input 1 MΩ ≤ 400 Vpk (DC + AC), DC~10 kHz
voltage 50 Ω ≤ 5V rms
SFDR ≥ 45dBc
60 dB up to 200 MHz
CH to CH 50 dB up to 500 MHz 60 dB up to 200 MHz 60 dB up to 200 MHz
Isolation (@50Ω) 50 dB up to 500 MHz 50 dB up to 350 MHz
40 dB up to 1 GHz
Probe Attenuation 1X, 10X, 100X, custom
* 1: 50Ω input impedance, 50 mV/div, 4GSa/s, 24.9943MHz/-1dBFS input
* 2: Use the Stdev (also known as ACrms) measurement

Horizontal SDS3104X HD SDS3054X HD SDS3034X HD


Time scale 200 ps/div – 1000s/div 500 ps/div – 1000s/div 1 ns/div – 1000 s/div
Range 10 divisions
Display mode Y-T, X-Y, Roll
Roll mode ≥ 50 ms/div
Skew (C1~C4) < 100 ps
Time base
±2 ppm initial (0~50℃); ±0.5 ppm 1st year aging; ±3 ppm 20-year aging
Accuracy

Trigger
Mode Auto, Normal, Single
Internal: ±4.1 div from the center of the screen
Level EXT: ± 0.61 V
EXT/5: ± 3.05 V
Ext Trigger input 1 MΩ ≤ 42 Vpk
voltage 50 Ω ≤ 5Vrms
By time: 8 ns ~ 30 s (8 ns step)
Hold off range
By event: 1 ~ 108
C1~C4
DC: Passes all components of the signal
AC: Blocks DC components and attenuates signals below 15 Hz
LFRJ: Attenuates the frequency components below 2.4 MHz
HFRJ: Attenuates the frequency components above 1.3 MHz
Noise RJ: Increases the trigger hysteresis
Coupling
EXT
DC: Passes all components of the signal
AC: Blocks DC components and attenuates signals below 18 Hz
LFRJ: Attenuates the frequency components below 7.5 kHz
HFRJ: Attenuates the frequency components above 250 kHz
C1~C4: ±0.2 div
Accuracy (typical)
EXT: ±0.3 div
Noise RJ = OFF Noise RJ = ON
>10 mV/div: ±0.26 div ±0.33 div
C1 ~ C4:
5 mV/div~10 mV/div: ±0.26 div ±0.33 div
≤ 2 mV/div: ±0.5 div ±0.5 div
Sensitivity
200 mVpp, DC ~ 10 MHz
EXT:
300 mVpp, 10 MHz ~ bandwidth(300 MHz)
EXT/5: 1 Vpp, DC ~ 10 MHz

10 INT.SIGLENT.COM
SDS3000X HD Series Digital Storage Oscilloscope

1.5 Vpp, 10 MHz ~ bandwidth(300 MHz)


C1~C4: < 10 ps rms (typical) ,≥ 6 div Vpp sine,2.5 mV/div ~ 10 V/div
Jitter
EXT: < 200 ps rms
Pre-Trigger: 0 ~ 100% memory
Displacement
Delay-Trigger: 0 ~ 10,000 div
Up to 2 zones
Zone Source: C1~C4
Property: Intersect, Not Intersect
Edge Trigger
Source C1~C4/EXT/(EXT/5)/AC Line/D0~D15
Slope Rising, Falling, Rising & Falling
Slope Trigger
Source C1~C4
Slope Rising, Falling
Limit range <, >, in range, out of range
Time range 2 ns ~ 20 s, Resolution = 1 ns
Pulse Width Trigger
Source C1~C4/D0~D15
Polarity +width, -width
Limit range <, >, in range, out of range
Time range 2 ns ~ 20 s, Resolution = 1 ns
Video Trigger
Source C1~C4
Standard NTSC, PAL, 720p/50, 720p/60, 1080p/50, 1080p/60, 1080i/50, 1080i/60, Custom
Synchronization Any, Select
Trigger Condition Line, Field
Window Trigger
Source C1~C4
Window type Absolute, Relative
Interval Trigger
Source C1~C4/D0~D15
Slope Rising, Falling
Limit range <, >, in range, out of range
Time range 2 ns ~ 20 s, Resolution = 1 ns
Dropout Trigger
Source C1~C4/D0~D15
Timeout type Edge, State
Slope Rising, Falling
Time range 2 ns ~ 20 s, Resolution = 1 ns
Runt Trigger
Source C1~C4
Polarity Positive, Negative
Limit range <, >, in range, out of range
Time range 2 ns ~ 20 s, Resolution = 1 ns
Pattern Trigger
Source C1~C4/D0~D15
Pattern Setting Don’t Care, Low, High
Logic AND, OR, NAND, NOR
Limit range <, >, in range, out of range
Time range 2 ns ~ 20 s, Resolution = 1 ns
Qualified Trigger
Type State, State with Delay, Edge, Edge with Delay
Qualified Source C1~C4/D0~D15
Edge Trigger Source C1~C4/D0~D15
Nth Edge Trigger
Source C1~C4/D0~D15
Slope Rising, Falling
Idle time 8 ns ~ 20 s, Resolution = 1 ns

INT.SIGLENT.COM 11
SDS3000X HD Series Digital Storage Oscilloscope

Edge Number 1 ~ 65535


Delay Trigger
Source A C1~C4/D0~D15
Source B C1~C4/D0~D15
Slope Rising, Falling
Limit range <, >, in range, out of range
Time range 2 ns ~ 20 s, Resolution = 1 ns
Serial Trigger
Source C1~C4/D0~D15
Standard: I2C, SPI, UART, CAN, LIN
Protocol
Optional: CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT
I2 C Type: Start, Stop, Restart, No Ack, EEPROM, Address & Data, Data Length
SPI Type: Data
UART Type: Start, Stop, Data, Parity Error
CAN Type: All, Remote, ID, ID+Data, Error
LIN Type: Break, Frame ID, ID+Data, Error
CAN FD(Optional) Type: Start, Remote, ID, ID+Data, Error
FlexRay(Optional) Type: TSS, Frame, Symbol, Errors
I2S(Optional) Type: Data, Mute, Clip, Glitch, Rising Edge, Falling Edge
MIL-STD-1553B
Type:Transfer, Word, Error, Timing
(Optional)
SENT(Optional) Type: Start, Slow channel, Fast channel, Error
ARINC429 (Optional) Type: Word Start, Word End, Label, Label+Data, Error, Any Bit, Any Bit of 0, Any Bit of 1

Serial Decoder
Decoders 2
Threshold -4.1 ~ 4.1 div
List 1 ~ 7 lines
Decoder type Full duplex
I2 C
Source C1~C4/D0~D15
Signal SCL, SDA
Address 7-bit, 10-bit
SPI
Source C1~C4/D0~D15
Signal CLK, MISO, MOSI, CS
Edge Select Rising, Falling
Chip select Active high, Active low, Clock timeout
Bit Order LSB, MSB
UART
Source C1~C4/D0~D15
Signal RX, TX
Data Width 5-bit, 6-bit, 7-bit, 8-bit
Parity Check None, Odd, Even, Mark, Space
Stop Bit 1-bit, 1.5-bit, 2-bit
Idle Level Low, High
Bit Order LSB, MSB
CAN
Source C1~C4/D0~D15
LIN
LIN Version Ver 1.3, Ver 2.0
Source C1~C4/D0~D15
Baud Rate 600 bps, 1200 bps, 2400 bps, 4800 bps, 9600 bps, 19200 bps, Custom
CAN FD(Optional)
Source C1~C4/D0~D15
Nominal Baud Rate 10 kbps, 25 kbps, 50 kbps, 100 kbps, 250 kbps, 1 Mbps, Custom
Data Baud Rate 500 kbps, 1 Mbps, 2 Mbps, 5 Mbps, 8 Mbps, 10 Mbps, Custom
FlexRay(Optional)
Source C1~C4/D0~D15
12 INT.SIGLENT.COM
SDS3000X HD Series Digital Storage Oscilloscope
Baud Rate 2.5 Mbps, 5 Mbps, 10 Mbps, Custom
I2S(Optional)
Source C1~C4/D0~D15
Signal BCLK, WS, DATA
Audio Variant Audio-I2S, Audio-LJ, Audio-RJ
Start Bits 0~31
Data Bits 1~32
MIL-STD-1553B(Optional)
Source C1~C4
SENT(Optional)
Source C1~C4/D0~D15
Manchester(Optional)
Source C1~C4
Baud Rate 500 bps~5 Mbps
ARINC429(Optional)
Source C1~C4
Baud Rate 12.5 kbps~100 kbps, tolerance 1%~20%
Word format L/SDI/D/SSM,L/D/SSM,L/D

Measurement
Automatic Measurement
Source C1~C4, D0~D15, Z1~Z4, F1~F4, M1~M4, Ref, History
Mode Simple, Advanced
Screen
Range
Gated: inside screen, definable with separate Gate cursors
Custom Threshold Upper, Middle, Lower
No. of Measurements Display 12 measurements at the same time (Display mode = M2)
Max, Min, Pk-Pk, Top, Base, Amplitude, Mean, Cycle Mean, Stdev, Cycle Stdev, RMS, Cycle RMS,
Vertical Parameters
Median, Cycle Median, FOV, FPRE, ROV, RPRE, Level@Trigger
Period, Frequency, Time@max, Time@min, +Width, -Width, 10-90%Rise time, 90-10%Fall time, Rise
Horizontal Parameters time, Fall time, +Burst Width, -Burst Width, +Duty Cycle, -Duty Cycle, Delay, Time@Middle, Cycle-
Cycle jitter
+Area@DC, -Area@DC, Area@DC, Absolute Area@DC, +Area@AC, -Area@AC, Area@AC,
Miscellaneous
Absolute Area@AC, Cycles, Rising Edges, Falling Edges, Edges, Positive pulses, Negative pulses,
Parameters
Positive Slope, Negative Slope
Phase, FRFR, FRFF, FFFR, FFFF, FRLR, FRLF, FFLR, FFLF, Skew, Tsu@R, Tsu@F, Th@R,
Delay Parameters
Th@F
Statistics Current, Mean, Min, Max, Sdev, Count, Histogram, Trend, Track
Statistics Count Unlimited, 1~1024
Cursors
Source C1~C4, D0~D15, F1~F4, M1~M4, Ref, Histogram
Manual : Time X1, X2, (X1-X2), (1/ΔT); Vertical Y1, Y2, (Y1-Y2)
Type Track: Time X1, X2, (X1-X2)
Measure: indicates the measurement on specific parameter

Math
Trace F1~F4
Source C1~C4, M1~M4, F1~F4, Zoom traces
FFT, +, -, x, ÷, ∫dt, d/dt, √, Identity, Negation, |x|, Sign, ex, 10x, ln, lg, Interpolation, Max hold, Min
Operation
hold, ERES, Average, Filter, Formula Editor
Length: 4 Mpts, 2 Mpts, 1 Mpts, 512 kpts, 256 kpts, 128 kpts, 64 kpts, 32 kpts, 16 kpts, 8 kpts, 4 kpts,
2 kpts
Window: Rectangular, Blackman, Hanning, Hamming, Flattop
FFT
Display: Full Screen, Split, Exclusive
Mode: Normal, Max hold, Average
Tools: Peaks, Markers

Analysis
Search
Source C1~C4, History
Mode Edge, Slope, Pulse, Interval, Runt
Copy setting Copy from trigger, Copy to trigger

INT.SIGLENT.COM 13
SDS3000X HD Series Digital Storage Oscilloscope
Navigate
Type Search event, Time, History frame
Mask Test
Source C1~C4,Z1~Z4
Mask creating Auto (Create mask), Customized (Mask Editor)
Mask test speed Up to 28,000 frames/s
DVM
Source C1~C4
Mode DC mean, DC RMS, AC RMS, Peak-peak, Amplitude
Plot Bar, Histogram, Trend
Gate 20 ms
Bode Plot
Source C1~C4
Supported signal SAG1021I (Connection: USB),
sources SDG series waveform generators (Connection: USB, LAN)
Sweep type Simple, Vari-level
Mode: Linear, Logarithmic
Frequency
Range: 10 Hz ~ 120 MHz
Measure Upper cutoff frequency, Lower cutoff frequency, Bandwidth, Gain margin, Phase margin
Power Analysis (optional)
Power quality, Current Harmonics, Inrush current, Switching loss, Slew rate, Modulation, Output
Measure
ripple, Turn on/turn off, Transient response, PSRR, Efficiency, SOA
Histogram
Source C1~C4
Type Horizontal, Vertical, Both
Counter
Source C1~C4
Frequency resolution 7 digits
Totalizer Counter on edges, supports Gate and Trigger

Digital Channels(optional)
Max. Sampling Rate 1 GSa/s
Memory Depth 100 Mpts/ch
Min. Detectable Pulse
3.3 ns
Width
Level Group D0~D7, D8~D15
Level Range -10 V~10 V
Logic Type TTL, CMOS, LVCMOS3.3, LVCMOS2.5, Custom
D0~D15: ±1 sampling interval
Skew
Digital to Analog: ± (1 sampling interval +1 ns)

Waveform Generator (optional)


Channels 1
Max. Output Frequency 50 MHz
Sampling Rate 125 MSa/s
Frequency Resolution 1 μHz
Frequency Accuracy ±50 ppm
Vertical Resolution 14 bit
-1.5 V ~ +1.5 V (into 50 Ω)
Amplitude Range
-3 V ~ +3 V (into High-Z)
Waveforms Sine, Square, Ramp, Pulse, DC, Noise, 45 Arbitrary
Output Impedance 50 Ω ± 2%
Protection Over voltage protection, Current limit
Isolated voltage ±42 Vpk
Sine
Frequency 1 μHz ~ 50 MHz
Offset accuracy (10
±(1%*offset setting value +3 mVpp)
kHz)
Amplitude flatness ±0.3 dB, compare to 10 kHz, 2.5 Vpp into 50 Ω
DC ~ 1 MHz -60 dBc
SFDR 1 MHz ~ 5 MHz -55 dBc
5 MHz ~ 25 MHz -50 dBc
Harmonic distortion DC ~ 5 MHz -50 dBc
14 INT.SIGLENT.COM
SDS3000X HD Series Digital Storage Oscilloscope
5 MHz ~ 25 MHz -45 dBc
Square/Pulse
Frequency 1 μHz ~ 10 MHz
Duty cycle 1% ~ 99%
Edge < 24 ns (10% ~ 90%)
Overshoot < 3% (typical,1 kHz, 1 Vpp)
Pulse width > 50 ns
Jitter (cycle-cycle) < 500 ps + 10 ppm
Ramp
Frequency 1 μHz ~ 300 kHz
Linearity < 0.1% of Pk-Pk (typical, 1 kHz, 1 Vpp, 50% symmetry)
Channels 0% ~ 100%
DC
±1.5 V (into 50 Ω)
Offset range
±3 V (into Hi-Z)
Accuracy ±(|setting value|*1% + 3 mV)
Noise
Bandwidth (-3 dB) >50 MHz
Arb
Frequency 1 μHz ~ 5 MHz
Waveform memory 16 kpts
Sample rate 125 MSa/s
Wave import From EasyWaveX, from U-disk, directly from waveform data of analog channels

I/O
USB 3.0 Host x2,
Front
Calibration Signal: 1 kHz,3 V Square
USB 2.0 Host,
USB 3.0 Device,
Rear LAN: 10/100/1000M (RJ45),
External Trigger,EXT: ≤1.5 Vrms,EXT/5: ≤ 7.5Vrms,
Auxiliary Output: TRIG OUT(3.3 V LVCMOS), PASS/FAIL OUT(3.3 V TTL)

Display
Display Type 10.1 TFT LCD with capacitive touch screen
Resolution 1024×600
Contrast (typical) 500:1
Backlight (typical) 500 nit

Display Setting
Range 8 x 10 grid
Display Type Dot, Vector
Persistence Time OFF, 0.1 s, 0.2 s, 0.5 s, 1 s, 5 s, 10 s, 30 s, infinite
Color Display Normal, Color;
Supports customer trace color
Language Simplified Chinese, Traditional Chinese, English, French, Japanese, German, Spanish, Russian,
Italian, Portuguese
Built-in Help System Simplified Chinese, English

Environmental
Operating: 0 °C ~ 50 °C
Temperature
Non-operating: -30 °C ~ 70 °C
Operating: 5% ~ 90%RH, 30℃, degraded to 50%RH at 50 ℃
Humidity
Non-operating: 5% ~ 95%
Operating: ≤ 3,000 m, 25 ℃
Altitude
Non-operating: ≤15,000 m
Meets EMC directive (2014/30/EU), meets or exceeds IEC 61326-1:2012/EN61326-1:2013 (Basic)
CLASS A group 1
Electromagnetic Conducted disturbance CISPR 11/EN 55011
150 kHz-30 MHz
Compatibility
CLASS A group 1
Radiated disturbance CISPR 11/EN 55011
30 MHz-1 GHz

INT.SIGLENT.COM 15
SDS3000X HD Series Digital Storage Oscilloscope
Electrostatic discharge (ESD) IEC 61000-4-2/EN 61000-4-2 4.0 kV (Contact),8.0 kV (Air)
10 V/m (80 MHz to 1 GHz);
Radio-frequency
IEC 61000-4-3/EN 61000-4-3 3 V/m (1.4 GHz to 2 GHz);
electromagnetic field Immunity
1 V/m (2.0 GHz to 2.7 GHz)
Electrical fast transients (EFT) IEC 61000-4-4/EN 61000-4-4 2kV (Input AC Power Ports)
1kV (Line to line)
Surges IEC 61000-4-5/EN 61000-4-5
2kV (Line to ground)
Radio-frequency continuous
IEC 61000-4-6/EN 61000-4-6 3 V, 0.15-80 MHz
conducted Immunity
Voltage Dips:
0% UT during 1 cycle;
40% UT during 10/12 cycles;
Voltage dips and interruptions IEC 61000-4-11/EN 61000-4-11
70% UT during 25/30 cycles
Voltage interruptions: 0% UT
during 250/300 cycles
UL 61010-1:2012/R: 2018-11; CAN/CSA-C22.2 No. 61010-1:2012/A1:2018-11.
Safety
UL 61010-2-030:2018; CAN/CSA-C22.2 No. 61010-2-030:2018.
RoHS EU 2015/863

Power Supply
Input Voltage & Frequency 100 ~ 240 Vrms 50/60 Hz
Power consumption 120 W max., 80 W typical, 4 W typical in standby mode

Mechanical
Length × Height × Width = 317.2 mm × 236.0 mm × 149.0 mm
Dimensions
(including knobs and supporting legs)
Weight Net Weight 4.1 kg, Gross Weight 5.6 kg

Ordering Information
Model Description
SDS3104X HD 1 GHz, 4 GSa/s, 4-CH, 12-bit, 400 Mpts/ch memory depth, 10.1” capacitive touch screen
SDS3054X HD 500 MHz, 4 GSa/s, 4-CH, 12-bit, 400 Mpts/ch memory depth, 10.1” capacitive touch screen
SDS3034X HD 350 MHz, 4 GSa/s, 4-CH, 12-bit, 400 Mpts/ch memory depth, 10.1” capacitive touch screen

Standard Accessories Quantity


USB cable 1
Quick start 1
Passive probe (500 MHz) 1/channel
Certificate of calibration 1
Wireless mouse 1
Power cord 1

Optional Accessories Part No.


USB isolated waveform generator SAG1021I
16-channel logic probe SPL2016
Power Analysis deskew fixture DF2001A
STB3 demo signal source STB3
USB-GPIB adapter USB-GPIB
High-speed active probe SAP1000, SAP2500
High voltage probe HPB4010
High-speed differential probe SAP2500D
DPB1300/DPB4080/DPB5150/
High voltage differential probe
DPB5150A/DPB5700/DPB5700A
CPL5100/CP4020/CP4050/CP4070/CP4070A
Current probe CP6030/CP6030A/CP6150/CP6500/SCP5030/SCP
5030A/SCP5150/SCP5150A
Bag BAG-S2

16 INT.SIGLENT.COM
SDS3000X HD Series Digital Storage Oscilloscope
Options Part No.
Waveform generator (software) SDS3000HD-FG
16 digital channels (software) SDS3000HD-16LA
Power Analysis (software) SDS3000HD-PA
I2S trigger & decode (software) SDS3000HD-I2S
MIL-STD-1553B trigger & decode (software) SDS3000HD-1553B
FlexRay trigger & decode (software) SDS3000HD-FlexRay
CAN FD trigger & decode (software) SDS3000HD-CANFD
SENT trigger & decode (software) SDS3000HD-SENT
Manchester decode (software) SDS3000HD-Manch
ARINC429 trigger & decode (software) SDS3000HD-ARINC
350 MHz to 500 MHz bandwidth upgrade (software) SDS3000HD-BW3T5
350 MHz to 1 GHz bandwidth upgrade (software) SDS3000HD-BW3TA
500 MHz to 1 GHz bandwidth upgrade (software) SDS3000HD-BW5TA

INT.SIGLENT.COM 17
SDS3000X HD Series Digital Storage Oscilloscope

About SIGLENT

SIGLENT is an international high-tech company, concentrating on R&D, sales,

production and services of electronic test & measurement instruments.

SIGLENT first began developing digital oscilloscopes independently in 2002.

After more than a decade of continuous development, SIGLENT has extended

its product line to include digital oscilloscopes, isolated handheld

oscilloscopes, function/arbitrary waveform generators, RF/MW signal

generators, spectrum analyzers, vector network analyzers, digital multimeters,

DC power supplies, electronic loads and other general purpose test

instrumentation. Since its first oscilloscope was launched in 2005, SIGLENT

has become the fastest growing manufacturer of digital oscilloscopes. We

firmly believe that today SIGLENT is the best value in electronic test &

measurement.

Headquarters:
SIGLENT Technologies Co., Ltd

Add: Bldg No.4 & No.5, Antongda Industrial

Zone, 3rd Liuxian Road, Bao'an District,

Shenzhen, 518101, China

Tel: + 86 755 3688 7876

Fax: + 86 755 3359 1582

Email: sales@siglent.com

Website: int.siglent.com

North America:
SIGLENT Technologies America, Inc

6557 Cochran Rd Solon, Ohio 44139

Tel: 440-398-5800

Toll Free: 877-515-5551

Fax: 440-399-1211
Follow us on
Email: info@siglent.com Facebook: SiglentTech