0% found this document useful (0 votes)
10 views7 pages

DS1000D E Datasheet

The RIGOL DS1000E and DS1000D series digital oscilloscopes are economical, high-performance instruments featuring dual analog channels, a maximum bandwidth of 100MHz, and a 16-channel logic analyzer for mixed signal measurements. They offer various applications including electronic circuit testing and education, along with user-friendly features like a built-in help menu and adjustable waveform intensity. The oscilloscopes also support advanced functions such as automatic measurements, waveform recording, and pass/fail testing, making them suitable for both R&D and production environments.

Uploaded by

Ruben Caldas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
10 views7 pages

DS1000D E Datasheet

The RIGOL DS1000E and DS1000D series digital oscilloscopes are economical, high-performance instruments featuring dual analog channels, a maximum bandwidth of 100MHz, and a 16-channel logic analyzer for mixed signal measurements. They offer various applications including electronic circuit testing and education, along with user-friendly features like a built-in help menu and adjustable waveform intensity. The oscilloscopes also support advanced functions such as automatic measurements, waveform recording, and pass/fail testing, making them suitable for both R&D and production environments.

Uploaded by

Ruben Caldas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

RIGOL

Data Sheet
DS1000E, DS1000D Series
Digital Oscilloscopes
DS1102E, DS1052E, DS1102D, DS1052D

Product Overview
The DS1000E, DS1000D series instruments are
economical, high-performance digital oscilloscopes.
The DS1000E series scopes feature dual channels
and 1 external trigger channel.
The DS1000D series scopes feature dual channels
and 1 external trigger channel as well as a 16
channel logic analyzer.

Applications Easy to Use Design

 Electronic Circuit Test  Built-in help menu makes the features


 Circuit Functional Test more convenient
 Logical Signal Comparison  Multiple Language User Interface, support
 Component R & D or Failure Analysis Chinese & English input
 Mixed Signal Circuit Test  Supports USB disk and local files storage
 Education & Training  Adjustable waveform intensity
 One-Button signal display with AUTO key
 Easy to read and access menus
 Powerful UltraScope PC application software
Main Features  Built-in FFT function
 Dual analog channels and 16 channels logic  Adjustable digital filter settings
analyzer, 100MHz maximum bandwidth,  High resolution delayed scan function
1GSa/s maximum real-time Sampling rate and  Pass/Fail detection function enables
25GSa/s maximum equivalent Sample rate isolated output for production applications
 5.6 inch, 64 k TFT color LCD makes the  Math operations available to multiple waves
waveform display clear and vivid  Standard configuration interface: USB
 Variety of trigger types: Edge, Pulse Width, Device, USB Host , RS-232 and support USB
Video, Slope, Alternate, Pattern and disk storage and PictBridge printer standards
Duration  “Key Lock” function meets the needs of
 Unique, adjustable trigger sensitivity enables industrial production
triggering in high noise signal environments  Support for remote command control using
 Able to measure 20 types of wave VISA drivers via USB or RS-232 and standard
parameters and track measurements with SCPI instruction set
cursors automatically
 Unique waveform record and replay

2010 Update
RIGOL Technologies USA, Inc.
Automatically Measure 20 Wave Parameters Cursor Measure
DS1000E & DS1000D series oscilloscopes
provide 20 types of wave parameters for
automatic measurements, which contain
10 voltage and 10 time parameters.
In cursor mode, users can easily
measure and track signals. Additionally,
Automatic measure 3 types of cursor measurements are FFT cursor measure
available: Manual, Track and Auto.

Multiple Trigger
Both DS1000E and DS1000D series scopes feature multiple trigger modes:
 Edge trigger, Pulse Width trigger, Video trigger, Slope trigger,
Alternate trigger, Pattern trigger (DS1000D), Duration trigger
(DS1000D)
The Duration trigger is a new trigger type combining pattern and pulse width
triggering. The adjustable trigger sensitivity is ideal for ignoring
noise in signals that would otherwise cause false triggering.
Pattern trigger

16 Channel Logic Analyzer

Equipped with a 16 channel logic analyzer, the DS1000D series mixed


signal oscilloscopes achieve mixed signal measurements coordinated
with the 2 analog channels.
Each channel can be turned on or off independently, or in groups of
Digital channels setup
8 (D7-D0 and D15-D8); also, you can adjust waveform size and threshold
types or change the display positions on screen for the digital channels.
Waveform Recording
With the waveform recording function on the DS1000E and DS1000D
series oscilloscopes, not only the outputs from the two channels can be
recorded, but also the output of the Pass/Fail test. In total, up to 1000
frames of waves can be recorded. Additionally, users can view waves Waveform recording
and independently recall or save specific waveforms for further analysis.
Pass/Fail Testing

The Pass/Fail function monitors changes in a signal by comparing


whether the input signal is within the pre-defined mask. The test results
can be displayed on screen, output by isolated pass/fail port, and/or set to
generate an alarm via the system speaker. Pass/Fail testing
UltraScope Software
RIGOL provides UltraScope, a powerful PC software application, which
enables users to: Capture and measure waves; Perform local or remote
operations; Save waves in “.bmp” format; Save files as “.txt” or “.xls”
format; Print waveforms.
Measurement window

1
Specifications
All specifications apply to DS1000E, DS1000D Series Oscilloscopes unless where noted. To come up to
these specifications, two conditions must be met:

 The instrument must have been operated continuously for 30 minutes under the specified
operating temperature.
 Perform Self-Calibration operation through the Utility menu if the range of operating
temperature variations up to or more than 5°C.
NOTE: All specifications are guaranteed except where marked “typical”.

Specifications

Bandwidth
DS1102E DS1052E DS1102D DS1052D
100MHz 50MHz 100MHz 50MHz
Acquisition
Sample Modes Real-Time Sample Equivalent Sample
DS1102X DS1052X
Sample Rate 1GSa/s, 200MSa/s[1]
25GSa/s 10GSa/s
The waveform will be displayed one time while all the channels finish N
Averages
times Sample, N could be selectable from 2, 4, 8, 16, 32, 64, 128 and 256
Inputs
Input Coupling DC, AC, GND
Input Impedance 1MΩ± 2%, the input capacity is 18pF± 3pF
Probe Attenuation Factors 1X, 5X, 10X, 50X, 100X, 500X,1000X
400V (DC+AC Peak, 1MΩ input impedance)
Maximum Input Voltage
40V (DC+AC Peak) [1]
Time Delay between Channel (typical) 500ps
Horizontal
Real-Time: 13.65Sa/s-1GSa/s
Sample Rate Range
Equivalent: 13.65Sa/s-25GSa/s
Waveform Interpolation Sin(x)/x
Channel Memory Depth Memory Depth
Sample rate
Mode (normal) (long memory)
Single
1GSa/s 16kpts N.A.
channel
Single 500MSa/s
Record Length 16kpts 1Mpts
channel or lower
Dual 500MSa/s
8kpts N.A.
channel or lower
Dual 250MSa/s
8kpts 512kpts
channel or lower
2ns/div~50s/div, DS1102X
Scanning Speed Range
5ns/div~50s/div, DS1052X
(Sec/div)
1-2-5 Sequence
Sample Rate and Delay
± 50ppm (any interval ≥1ms)
Time Accuracy
Delta Time
Single: ± (1 Sample interval + 50ppm × reading + 0.6 ns)
Measurement Accuracy
>16 averages: ± (1Sample interval + 50ppm × reading + 0.4 ns)
(Full Bandwidth)
Vertical

2
A/D Converter 8-bit resolution, all channels sample simultaneously[2]
Volts/div Range 2mV/div~10V/div (at the input terminal connecting to BNC)
Maximum input voltage on analog channel
CAT I 300Vrms, 1000Vpk; instantaneous overvoltage 1000Vpk
CAT II 100Vrms, 1000Vpk
Maximum Input RP2200 10:1:CAT II 300Vrms
RP3200 10:1:CAT II 300Vrms
RP3300 10:1:CAT II 300Vrms
± 40V (250mV/div~10V/div)
Offset Range
± 2V (2mV/div~245mV/div)
100MHz (DS1102D,DS1102E)
Analog Bandwidth
50MHz (DS1052D, DS1052E)
100MHz (DS1102D, DS1102E)
Single-shot Bandwidth
50MHz (DS1052D, DS1052E)
Selectable Analog
20MHz
Bandwidth Limit (typical)
Lower Frequency
≤5Hz (at input BNC)
Response (AC –3dB)
Rise Time at BNC (typical) <3.5ns, <7ns, respectively at 100MHz, 50MHz
2mV/div-5mV/div:
± 4% (In Normal or Average acquisition mode)
DC Gain Accuracy
10mV/div-10V/div:
± 3% (In Normal or Average acquisition mode)
When vertical displacement is zero, and N ≥16:
± (DC Gain Accuracy× reading+0.1div+1mV)
When vertical displacement is not zero, and N ≥16:
DC Measurement ± [DC Gain Accuracy× (reading+vertical displacement)+(1% of
Accuracy, Average vertical displacement) + 0.2div]
Acquisition Mode When vertical scale is between 2mV/div and 245mV/div, add 2mV
more for setting value.
When vertical scale is between 250mV/div and 10V/div, add 50mV
more for setting value.
Under same setting and condition, the voltage difference (△ V)
Delta Volts
between any two points in the waves coming from the average of
Measurement Accuracy
more than 16 waves have been acquired: ± (DC Gain
(Average Acquisition Mode)
Accuracy× reading + 0.05 div)
Trigger
Trigger Sensitivity 0.1div~1.0div (adjustable)
Internal ± 6 divisions from center of screen
Trigger Level Range
EXT ± 1.2V
Trigger Level Accuracy (typical) Internal ± (0.3div × V/div)(± 4 divisions from center of screen)
applicable for the signal of
EXT ± (6% of setting + 200 mV)
rising and falling time ≥20ns
In Normal mode: pre-trigger (memory depth/ 2*Sample rate),
Trigger Offset delayed trigger 1s
In Slow Scan mode: pre-trigger 6div, delayed trigger 6div
Trigger Holdoff Range 500ns~1.5s

Set Level to 50% (typical) When input signal frequency ≥50Hz

Edge Trigger
Edge trigger slope Rising, Falling, Rising + Falling
Pulse WidthTrigger
Trigger Condition (>, <, =) Positive pulse width, (>, <, =) Negative pulse width
Pulse Width Range 20ns ~10s

3
Video Trigger
Video Standard Support for standard NTSC, PAL and SECAM broadcast systems. Line
Line Frequency number range: 1~525 (NTSC) and 1~625 (PAL/SECAM)
Slope Trigger
Trigger Condition (>, <, =) Positive slope, (>, <, =) Negative slope
Time Setting 20ns~10s
Alternate Trigger
Trigger on CH1 Edge, Pulse Width, Video, Slope
Trigger on CH2 Edge, Pulse Width, Video, Slope
Pattern Trigger[1]
Pattern Type D0~D15 select H, L, X, ,
Duration Trigger[1]
Pattern Type D0~D15 select H, L, X
Qualifier >, <, =
Time Setting 20ns~10s
Measurements
Voltage difference between cursors (∆V)
Manual Time difference between cursors (∆T)
Reciprocal of ∆T in Hertz (1/∆T)
Cursor Voltage value for Y-axis waveform
Track
Time value for X-axis waveform
Auto Cursors are visible when measure automatically
Vpp, Vamp, Vmax, Vmin, Vtop, Vbase, Vavg, Vrms, Overshoot, Preshoot, Freq,
Auto Measure Period, Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, Delay1→2 ,
Delay1→2
Remarks:
[1] For DS1000D Series;
[2] Only one channel is available when the Sample rate is 1GSa/s.

4
General Specifications

Display
Display Type 5.7inch. (145mm) diagonal TFT Liquid Crystal Display
Display Resolution 320 horizontal × RGB× 234 vertical pixels
Display Color 64k color
Display Contrast (typical) 150:1
Backlight Brightness (typical) 300 nit
Probe Compensator Output
Output Voltage (typical) Approximately 3Vpp (peak to peak value)
Frequency (typical) 1kHz
Power Supply
Supply Voltage 100 ~ 240VACRMS, 45~440Hz, CAT II
Power Consumption Less than 50W
Fuse 2A, T level, 250 V
Environmental
Operating 10℃~ 40℃
Ambient Temperature
Non-operating -20℃~ +60℃
Cooling Method forced cooling by fan
below +35℃: ≤90% relative humidity
Humidity
+35℃~ +40℃: ≤60% relative humidity
Operating at 3,000 m or below
Altitude
Non-operating at 15,000 m or below
Mechanical
Width 303mm
Dimensions Height 154mm
Depth 133mm
Without package 2.3kg
Weight
Packaged 3.5kg
IP Protection
IP2X
Calibration Interval
The recommended calibration interval is one year

5
Ordering Information Warranty

Name of Product Thank you for choosing RIGOL products!


RIGOL DS1000E, DS1000D series oscilloscopes RIGOL Technologies, Inc. warrants that this
Standard Accessories product will be free from defects in materials and
workmanship from the date of shipment. If a
 Probe× 2 (1.5m), (1:1 or 10:1 adjustable) product proved defective within the respective
Passive Probes period, RIGOL will provide repair or replace
 Power Cord as described in the complete warranty statement.
 USB Cable
 A Data Cable (DS1000D series) For the copy of complete warranty statement or other
 An Active Logic Head (DS1000D series) maintenance information, please contact us directly
 20 Logic Testing Clips (DS1000D series) at our local RIGOL sales and service office.
 20 Logic Testing leads (DS1000D series)
 A CD-ROM (including User’s Guide and
RIGOL does not provide any other warranties
Application Software)
except the one being provided by this summary
 A Quick Guide
and the warranty statement.
Optional Accessories

 BNC Cable
 RS232 Cable
 USB-GPIB Adapter
 DS1000E, DS1000D soft carrying case

Contact Us

If you have any questions, concerns, or thoughts about our products, documentation, or services,
please contact RIGOL Technologies USA, Inc. or your local distributor or representative.

To contact our US office:

Tel: (440) 232-4488


Toll Free: 877-4-RIGOL-1

Service & Support


8:30 am –5: 00 pm Eastern Time, Monday to Friday

Or by e-mail at:
info@rigol.com

Or mail to:
RIGOL Technologies USA, Inc.
7401 First Place Suite N
Oakwood Village, OH 44146

Outside of North America: Contact the local RIGOL distributors or sales office.
For the latest product information and service, visit our website: http://www.rigolna.com

You might also like