0101010101010101010101      0101010101010101010101
0101010101010101010101      0101010101010101010101
0101010101010101010101      0101010101010101010101
0101010101010101010101      0101010101010101010101
0101010101010101010101      0101010101010101010101
0101010101010101010101      0101010101010101010101
0101010101010101010101      0101010101010101010101
0101010101010101010101      0101010101010101010101
0101010101010101010101   0101010101010101010101
                         0101010101010101010101
0101010101010101010101 Digital  Oscilloscope
                         0101010101010101010101
0101010101010101010101 Waveform    Generator
0101010101010101010101 RF0101010101010101010101
                           Signal Generator      Product Selection Guide
                         0101010101010101010101
0101010101010101010101 Spectrum     Analyzer
0101010101010101010101    Network Analyzer   Every Bench.
                   Vector0101010101010101010101
0101010101010101010101    DC Power Supply    Every Engineer.
                         0101010101010101010101
0101010101010101010101 DC0101010101010101010101
                             Electronic Load Every Day.
                            Digital Multimeter
                         Probes & Accessories
      SIGLENT TECHNOLOGIES CO., LTD
   Super Phosphor Oscilloscope
SDS7000A Series                                                                      SDS6000A Series
SDS7404A H12 (4 GHz)                                                                 SDS6204A (2 GHz)
SDS7304A H12 (3 GHz)                                                                 SDS6104A (1 GHz)
                                                                                     SDS6054A (500 MHz)
Features and Benefits:
                                                                                     Features and Benefits:
• 4 analog channels, up to 4 GHz bandwidth with up to 20 GSa/s sample rate
                                                                                     • 4 analog channels, up to 2 GHz bandwidth with 5 GSa/s (10 GSa/s ESR)
• 12-bit ADC
                                                                                       sample rate at each channel
• Low background noise: 220 μVrms @ 4 GHz bandwidth
  SPO technology                                                                     • Low background noise, supports 0.5 mV/div to 10 V/div vertical scales
   • Waveform capture rates up to 1,000,000 wfm/s                                    • SPO technology
                                                                                        • Waveform capture rates up to 170,000 wfm/s (normal mode), and 750,000
   • Supports 256-level intensity grading and color temperature display modes
                                                                                          wfm/s (sequence mode)
   • 500 Mpts/ch standard, 1 Gpts/ch optional
                                                                                        • Supports 256-level intensity grading and color temperature display modes
   • Digital trigger system
                                                                                        • 500 Mpts Record length in total for all 4 channels
• Intelligent trigger: Edge, Slope, Pulse, Window, Runt, Interval, Dropout,
                                                                                        • Digital trigger system
  Pattern, Qualified, Nth edge, Setup/hold, Delay and Video (HDTV supported).
   Zone Trigger simplifies advanced triggering                                       • Intelligent trigger: Edge, Slope, Pulse, Window, Runt, Interval, Dropout,
                                                                                       Pattern, Qualified, Nth edge, Setup/hold, Delay and Video (HDTV supported).
• Serial bus triggering and decoder, supports protocols I2C, SPI, UART, CAN,
                                                                                        Zone Trigger simplifies advanced triggering
  LIN, CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT, Manchester, ARINC429 and
   USB 2.0                                                                           • Serial bus triggering and decoder, supports protocols I2C, SPI, UART, CAN,
                                                                                       LIN, CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT and Manchester
• Segmented acquisition (Sequence) mode, dividing the maximum record
  length into multiple segments (up to 124,000), according to trigger conditions     • Segmented acquisition (Sequence) mode, dividing the maximum record
                                                                                       length into multiple segments (up to 80,000), according to trigger conditions
   set by the user, with a very small dead time between segments to capture the
                                                                                        set by the user, with a very small dead time between segments to capture the
   qualifying event
                                                                                        qualifying event
• History waveform record (History) function, the maximum recorded waveform
  length is 124,000 frames                                                           • History waveform record (History) function, the maximum recorded waveform
                                                                                       length is 80,000 frames
• Automatic measurements on 50+ parameters, supports statistics with
  histogram, track, trend, Gating measurement, and measurements on Math,             • Automatic measurements on 50+ parameters, supports statistics with
                                                                                       histogram, track, trend, Gating measurement, and measurements on Math,
   History and Memory traces
                                                                                        History and Ref
• 4 Math traces (32 Mpts FFT, Filter, addition, subtraction, multiplication,
  division, integration, differential, square root, etc.), supports formula editor   • 4 Math traces (8 Mpts FFT, addition, subtraction, multiplication, division,
                                                                                       integration, differential, square root, etc.), supports formula editor
• Abundant data analysis functions such as Search, Navigate, SignalScan,
  Digital Voltmeter, Counter, Waveform Histogram, Bode plot, Power Analysis,         • Abundant data analysis functions such as Search, Navigate, Digital Voltmeter,
                                                                                       Counter, Waveform Histogram, Bode plot, Power Analysis and Eye/Jitter
   Eye/Jitter Analysis and Compliance Test
                                                                                        Analysis
• High Speed hardware-based Average, Hi-Res; High Speed hardware-based
  Mask Test function, with Mask Editor tool for creating user-defined masks          • High Speed hardware-based Average, Hi-Res; High Speed hardware-based
                                                                                       Mask Test function, with Mask Editor tool for creating user-defined masks
• 16 digital channels (optional)
                                                                                     • 16 digital channels (optional)
• Built-in 50 MHz waveform generator
                                                                                     • 25 MHz function / arbitrary waveform generator, built-in multiple predefined
• Large 15.6” HD TFT-LCD display with 1920 * 1080 resolution; Capacitive
                                                                                        waveforms
  touch screen supports multi-touch gestures
                                                                                     • Large 12.1” TFT-LCD display with 1280 * 800 resolution; Capacitive touch
• Interfaces include: 4x USB Host 3.1 Gen 1, 2x USB 3.0 Host, USB 2.0 Device,
                                                                                       screen supports multi-touch gestures
  2x 1000M LAN, DVI-D, DP 1.2, HDMI 1.4, Audio, External Triger In, Aux Out
   (Pass/Fail, Trigger Out), 10 MHz In, 10 MHz Out                                   • Interfaces include: USB Hosts, USB Device (USBTMC), LAN (VXI-11/Telnet/
                                                                                       Socket), micro SD card, Pass/Fail, Trigger Out, HDMI
• Built-in web server supports remote control over the LAN port using a web
  browser. Supports SCPI remote control commands. Supports external mouse            • Built-in web server supports remote control over the LAN port using a web
                                                                                       browser. Supports SCPI remote control commands. Supports external mouse
   and keyboard
                                                                                        and keyboard
                                                                                                                                                www.siglent.com 1
   Super Phosphor Oscilloscope
SDS6000L Series                                                                   SDS5000X Series
SDS6208L (2 GHz)                     SDS6204L (2 GHz)                             SDS5104X (1 GHz)
SDS6108L (1 GHz)                     SDS6104L (1 GHz)                             SDS5054X (500 MHz)
SDS6058L (500 MHz)                   SDS6054L (500 MHz)                           SDS5034X (350 MHz)
Features and Benefits:                                                            Features and Benefits:
• 8/4 analog channels + 1 external trigger. Designed for expansion. Combine       • 1 GHz, 500 MHz, 350 MHz models with real-time sample rate up to 5 GSa/s
  multiple units for a high-speed acquisition system with up to 512 channels.     • SPO technology
• Up to 2 GHz bandwidth with 5 GSa/s (10 GSa/s ESR) sample rate at each             • Waveform capture rates up to 110,000 wfm/s (normal mode), and 500,000
  channel                                                                             wfm/s (sequence mode)
• Low background noise, supports 0.5 mV/div to 10 V/div vertical scales             • Supports 256-level intensity grading and color temperature display modes
• SPO technology                                                                    • Record length up to 250 Mpts/ch, 500 Mpts in total for all 4 channels
   • Waveform capture rates up to 170,000 wfm/s (normal mode), and                  • Digital trigger system
     750,000 wfm/s (sequence mode)                                                • Intelligent trigger: Edge, Slope, Pulse, Window, Runt, Interval, Dropout,
   • Supports 256-level intensity grading and color temperature display modes       Pattern, Qualified, Nth edge, Setup/hold, Delay and Video (HDTV supported).
   • 500 Mpts Record length in total for all 4 channels                             Trigger zone helps to simplify advanced triggering
   • Digital trigger system                                                       • Serial bus triggering and decoder, supports protocols I2C, SPI, UART, CAN,
• Intelligent trigger: Edge, Slope, Pulse, Window, Runt, Interval, Dropout,         LIN, CAN FD, FlexRay, I2S and MIL-STD-1553B, SENT and Manchester
  Pattern, Qualified, Nth edge, Setup / hold, Delay and Video (HDTV               • Low background noise, supports 0.5 mV/div to 10 V/div voltage scales
   supported). Zone Trigger simplifies advanced triggering                        • Segmented acquisition (Sequence) mode, dividing the maximum record
• Serial bus triggering and decoder, supports protocols I2C, SPI, UART, CAN,        length into multiple segments (up to 100,000), according to trigger conditions
  LIN, CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT and Manchester                     set by the user, with a very small dead time between segments to capture the
• Segmented acquisition (Sequence) mode, dividing the maximum record                qualifying event
  length into multiple segments (up to 80,000), according to trigger conditions   • History waveform record (History) function, the maximum recorded waveform
   set by the user, with a very small dead time between segments to capture the     length is 100,000 frames
   qualifying event                                                               • Automatic measurement function on 50+ parameters, supports statistics
• History waveform record (History) function, the maximum recorded waveform         with histogram,trend, Gating measurement, Math measurement, History
  length is 80,000 frames                                                           measurement and Ref measurement
• Automatic measurements on 50+ parameters, supports statistics with              • Math function (2 Mpts FFT, addition, subtraction, multiplication, division,
  histogram, track, trend, Gating measurement, and measurements on Math,            integration, differential, square root, etc.), supports formula editor
   History, Memory and Ref                                                          Abundant data analysis functions such as Search, Navigate, Digital Voltmeter,
• 4 Math traces (8 Mpts FFT, addition, subtraction, multiplication, division,       Counter, Waveform Histogram, Bode plot and Power Analysis
  integration, differential, square root, etc.), supports formula editor          • High Speed hardware-based Average, ERES (Enhanced Resolution)
• Abundant data analysis functions such as Search, Navigate, Digital Voltmeter,   • High Speed hardware-based Mask Test function, with Mask Editor tool for
  Counter, Waveform Histogram, Power Analysis and Eye/Jitter Analysis               creating user-defined masks
• 16 digital channels (optional)                                                  • 16 digital channels (optional) with sample rate up to 1.25 GSa/s, record
• 25 MHz function / arbitrary waveform generator, built-in multiple predefined      length up to 62.5 Mpts
   waveforms                                                                      • 25 MHz function / arbitrary waveform generator, built-in multiple predefined
• Interfaces include: 4x USB Hosts, USB Device (USBTMC), 1000M LAN (VXI-            waveforms
  11/ Telnet/ Socket), micro SD card, Pass/Fail, Trigger Out, HDMI, 10MHz In,     • Large 10.1” TFT-LCD display with 1024 * 600 resolution; Capacitive touch
   10MHz Out                                                                        screen supports multi-touch gestures
• Built-in web server supports remote control over the LAN port using a web       • Supports external mouse and keyboard
  browser. Supports SCPI remote control commands. Supports external mouse         • 10 types of one-button shortcuts
   and keyboard                                                                   • Multiple interfaces: USB Host, USB Device (USBTMC), LAN (VXI-11, telnet,
                                                                                    socket, web), Pass/Fail, Trigger Out, 10 MHz In, 10 MHz Out, VGA output
                                                                                  • Built-in web server supports remote control by the LAN port using a web
                                                                                    browser
                                                                                  • Supports SCPI remote control commands
www.siglent.com 2
  Super Phosphor Oscilloscope
SDS3000X HD Series                                                                      SDS2000X HD Series
SDS3104X HD (1 GHz)                                                                     SDS2354X HD (350 MHz)
SDS3054X HD (500 MHz)                                                                   SDS2204X HD (200 MHz)
SDS3034X HD (350 MHz)                                                                   SDS2104X HD (100 MHz)
Features and Benefits:                                                                  Features and Benefits:
• 4 analog channels, up to 1 GHz bandwidth with up to 4GSa/s sample rate                • 12-bit High Resolution
• 12-bit ADC                                                                              • 12-bit Analog-Digital Convertors with sample rate up to 2 GSa/s
• Low background noise: 125 μVrms @ 1 GHz bandwidth                                       • Front ends with 70 μVrms noise floor @ 500 MHz bandwidth and 0.5% DC
• SPO technology                                                                            gain accuracy
  • Waveform capture rates up to 200,000 wfm/s in Normal mode and 890,000               • 4 analog channels, up to 350 MHz bandwidth (upgradable to 500 MHz)
     wfm/s in Sequence mode                                                             • SPO technology
  • Supports 256-level intensity grading and color temperature display modes              • Waveform capture rate up to 100,000 wfm/s (normal mode), and
  • Up to 400 Mpts/ch record length                                                         500,000 wfm/s (sequence mode)
  • Digital trigger system                                                                • Supports 256-level intensity grading and color temperature display modes
• Intelligent trigger: Edge, Slope, Pulse, Window, Runt, Interval, Dropout,               • Up to 200 Mpts/ch record length
  Pattern, Qualified, Nth edge, Setup/hold, Delay and Video (HDTV supported).             • Digital trigger system
  Zone Trigger simplifies advanced triggering                                           • Intelligent trigger: Edge, Slope, Pulse, Window, Runt, Interval, Dropout,
• Serial bus triggering and decoder, supports protocols I2C, SPI, UART, CAN,              Pattern, Qualified, Nth edge, Setup/hold, Delay and Video (HDTV supported).
  LIN, CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT, Manchester and ARINC429                 Zone Trigger simplifies advanced triggering
• Segmented acquisition (Sequence) mode, dividing the maximum record                    • Serial bus triggering and decoder, supports protocols I2C, SPI, UART, CAN,
  length into multiple segments (up to 80,000), according to trigger conditions           LIN, CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT and Manchester
  set by the user, with a very small dead time between segments to capture the          • Segmented acquisition (Sequence) mode, dividing the maximum record
  qualifying event                                                                        length into multiple segments (up to 80,000), according to trigger conditions
• History waveform record (History) function, the maximum recorded waveform               set by the user, with a very small dead time between segments to capture the
  length is 80,000 frames                                                                 qualifying event
• Automatic measurements on 50+ parameters, supports statistics with                    • History waveform record (History) function, the maximum recorded waveform
  histogram, track, trend, Gating measurement, and measurements on Math,                  length is 80,000 frames
  History and Memory traces                                                             • Automatic measurements on 50+ parameters, supports statistics with
• 4 Math traces (4 Mpts FFT, Filter, addition, subtraction, multiplication, division,     histogram, track, trend, Gating measurement, and measurements on Math,
  integration, differential, square root, etc.), supports formula editor                  History and Ref
• Abundant data analysis functions such as Search, Navigate, Digital Voltmeter,         • 2 Math traces (2 Mpts FFT, addition, subtraction, multiplication, division,
  Counter, Waveform Histogram, Bode plot and Power Analysis                               integration, differential, square root, etc.), supports formula editor
• High Speed hardware-based Average, ERES; High Speed hardware-based                    • Abundant data analysis functions such as Search, Navigate, Digital Voltmeter,
  Mask Test function, with Mask Editor tool for creating user-defined masks               Counter, Waveform Histogram, Bode plot and Power Analysis
• 16 digital channels (optional)                                                        • High Speed hardware-based Average, ERES; High Speed hardware-based
• External 50 MHz waveform generator (optional)                                           Mask Test function, with Mask Editor tool for creating user-defined masks
• Large 10.1” TFT-LCD display with 1024 * 600 resolution; Capacitive touch              • 16 digital channels (optional)
  screen supports multi-touch gestures                                                  • Built-in 25 MHz waveform generator
• Interfaces include: 2x USB 3.0 Host, 1x USB 2.0 Host , USB 3.0 Device                 • Large 10.1” TFT-LCD display with 1024 * 600 resolution; Capacitive touch
  (USBTMC), 1000M LAN ((VXI-11/Telnet/Socket/LXI)), External Triger In, Aux               screen supports multi-touch gestures
  Out (Pass/Fail, Trigger Out)                                                          • Interfaces include: USB Hosts, USB Device (USBTMC), LAN (VXI-11/Telnet/
• Built-in web server supports remote control over the LAN port using a web               Socket), Pass/Fail, Trigger Out
  browser. Supports SCPI remote control commands. Supports external mouse               • Built-in web server supports remote control over the LAN port using a web
  and keyboard                                                                            browser. Supports SCPI remote control commands. Supports external mouse
                                                                                          and keyboard
                                                                                                                                                         www.siglent.com 3
  Super Phosphor Oscilloscope
SDS2000X Plus Series                                                              SDS2000X-E Series
SDS2354X Plus (350 MHz)                                                           SDS2352X-E (350 MHz)
SDS2204X Plus (200 MHz)                                                           SDS2202X-E (200 MHz)
SDS2104X Plus / SDS2102X Plus (100 MHz)
                                                                                  Features and Benefits:
Features and Benefits:                                                            • Real-time sampling rate up to 2 GSa/s (1 GSa/s per channel, if both channels
• 350 MHz, 200 MHz, 100 MHz models with real-time sample rate up to 2 GSa/s.        active)
  A 500 MHz bandwidth upgrade option is available for 350 MHz models.             • Intelligent trigger: Edge, Slope, Pulse Width, Window, Runt, Interval, Time
• SPO technology                                                                    out (Dropout), Pattern
  • Waveform capture rates up to 120,000 wfm/s (normal mode) and 500,000          • Serial bus triggering and decoding (standard), supports protocols IIC, SPI,
    wfm/s (sequence mode)                                                           UART, CAN, LIN
  • Supports 256-level intensity grading and color temperature display modes      • Video trigger, supports HDTV
  • Record length up to 200 Mpts/ch, 400 Mpts in total for all 4 channels         • Low background noise with voltage scales from 500 μV/div to 10 V/div
  • Digital trigger system                                                        • 10 types of one-button shortcuts, supports Auto Setup, Default, Cursors,
• Intelligent trigger: Edge, Slope, Pulse, Window, Runt, Interval, Dropout,         Measure, Roll, History, Display/Persist, Clear Sweep, Zoom and Print
  Pattern and Video (HDTV supported). Trigger zone helps to simplify advanced     • Segmented acquisition (Sequence) mode, divides the maximum record length
  triggering                                                                        into multiple segments (up to 80,000), according to trigger conditions set by
• Serial bus triggering and decoder, supports I2C, SPI, UART, CAN, LIN               the user, with a very small dead time segment to capture qualifying events
  (Standard) and CAN FD, FlexRay, I2S, and MIL-STD-1553B, SENT and                • History waveform record (history) function (maximum recorded waveform
  Manchester (optional) protocols                                                   length is 80,000 frames)
• Low background noise, features 0.5 mV/div to 10 V/div voltage scales            • Automatic measurement function for 38 parameters as well as Measurement
• 10-bit mode provides higher resolution and lower noise                            Statistics, Zoom, Gating, Math, History and Reference functions
• Segmented acquisition (Sequence) mode, dividing the maximum record              • 1 Mpts FFT
  length into multiple segments (up to 90,000), according to trigger conditions   • Math and measurement functions use all sampled data points in memory (up
  set by the user, with a very small dead time between segments to capture the       to 28 Mpts)
  qualifying event                                                                • Preset key can be customized for user settings or factory “defaults”
• History waveform record (History) function for up to 90,000 triggered           • Security Erase mode
  waveforms (frames)                                                              • High Speed hardware based Pass / Fail function
• Automatic measurement function on 50+ parameters, supports statistics with      • Search and navigate
  histogram and trend                                                             • Large 7 inch TFT -LCD display with 800 * 480 resolution
• Two Math traces, support 2 Mpts FFT, +, -, x, ÷, d/dt, ∫dt, √, average, ERES,   • Multiple interface types: USB Host, USB Device (USB -TMC), LAN, Pass / Fail,
  and formula editor                                                                 Trigger Out
• Abundant data processing and analysis functions such as Search,                 • Supports SCPI remote control commands
  Navigate, Mask Test, Bode plot, Power Analysis (optional) and Counter           • VXI-11+SCPI, Telnet (port 5024) +SCPI and Socket (port 5025) +SCPI
• 16 digital channels (optional)                                                     programming over LAN
• Built-in 50 MHz waveform generator (optional)                                   • Supports web control and virtual instrument control panel for both PC and
• Large 10.1” TFT-LCD display with 1024x600 resolution; Capacitive touch            mobile terminals
  screen supports multi-touch gestures                                            • Web control update rate of up-to 10 times/s provides nearly real-time update
• Multiple interfaces: USB Host, USB Device (USBTMC), LAN(VXI-11/Telnet/            rate
  Socket), Pass/Fail, Trigger Out                                                 • Supports Multi-language display and embedded online help
• Built-in web server supports remote control by the LAN port using a web
  browser; Supports SCPI remote control commands
www.siglent.com 4
  Super Phosphor Oscilloscope
SDS1000X HD Series                                                                  SDS800X HD Series
SDS1204X HD / SDS1202X HD (200 MHz)                                                 SDS824X HD / SDS822X HD (200 MHz)
SDS1104X HD / SDS1102X HD (100 MHz)                                                 SDS814X HD / SDS812X HD (100 MHz)
                                                                                    SDS804X HD / SDS802X HD (70 MHz)
Features and Benefits:
• 12-bit High Resolution                                                            Features and Benefits:
  • 12-bit Analog-Digital Convertors with sample rate up to 2 GSa/s                 • 12-bit High Resolution
  • Front ends with 70 μVrms noise floor @ 200 MHz bandwidth                          • 12-bit Analog-Digital Convertors with sample rate up to 2 GSa/s
• 2/4 analog channels, up to 200 MHz bandwidth                                        • Front ends with 70 μVrms noise floor @ 200 MHz bandwidth
• SPO technology                                                                    • 2/4 analog channels, up to 200 MHz bandwidth
  • Waveform capture rate up to 120,000 wfm/s (normal mode), and 500,000            • SPO technology
    wfm/s (sequence mode)                                                             • Waveform capture rate up to 120,000 wfm/s (normal mode), and 500,000
  • Supports 256-level intensity grading and color temperature display modes            wfm/s (sequence mode)
  • Up to 100 Mpts record length                                                      • Supports 256-level intensity grading and color temperature display modes
  • Digital trigger system                                                            • Up to 100 Mpts record length
• Intelligent trigger: Edge, Slope, Pulse width, Window, Runt, Interval, Dropout,     • Digital trigger system
  Pattern, Video (HDTV supported) , Qualified, Nth edge, Delay, Setup/Hold          • Intelligent trigger: Edge, Slope, Pulse width, Window, Runt, Interval, Dropout,
  time.                                                                               Pattern, Video (HDTV supported) , Qualified, Nth edge, Delay, Setup/Hold
• Serial bus triggering and decoder, supports protocols I2C, SPI, UART, CAN,          time.
  LIN, CAN FD(decode only), FlexRay(decode only)                                    • Serial bus triggering and decoder, supports protocols I2C, SPI, UART, CAN,
• Segmented acquisition (Sequence) mode, dividing the maximum record                  LIN
  length into multiple segments (up to 80,000), according to trigger conditions     • Segmented acquisition (Sequence) mode, dividing the maximum record
  set by the user, with a very small dead time between segments to capture the        length into multiple segments (up to 80,000), according to trigger conditions
  qualifying event                                                                    set by the user, with a very small dead time between segments to capture the
• History waveform record (History) function, the maximum recorded waveform           qualifying event
  length is 80,000 frames                                                           • History waveform record (History) function, the maximum recorded waveform
• Automatic measurements on 50+ parameters, supports statistics with                  length is 80,000 frames
  histogram, track, trend, Gating measurement, and measurements on Math,            • Automatic measurements on 50+ parameters, supports statistics with
  History and Ref                                                                     histogram, track, trend, Gating measurement, and measurements on Math,
• 4 Math traces (2 Mpts FFT, addition, subtraction, multiplication, division,         History and Ref
  integration, differential, square root, etc.), supports formula editor            • 4 Math traces (2 Mpts FFT, addition, subtraction, multiplication, division,
• Abundant data analysis functions such as Search, Navigate, Counter, Bode            integration, differential, square root, etc.), supports formula editor
  plot and Power Analysis                                                           • Abundant data analysis functions such as Search, Navigate, Counter, Bode
• High Speed hardware-based Mask Test function, with Mask Editor tool for             plot and Power Analysis
  creating user-defined masks                                                       • High Speed hardware-based Mask Test function, with Mask Editor tool for
• 16 digital channels (optional)                                                      creating user-defined masks
• 25 MHz waveform generator(optional)                                               • 16 digital channels (optional)
• Large 10.1” TFT-LCD display with 1024 * 600 resolution; Capacitive touch          • 25 MHz waveform generator(optional)
  screen supports multi-touch gestures                                              • 7” TFT-LCD display with 1024 * 600 resolution; Capacitive touch screen
• Interfaces include: USB Hosts, USB Device (USBTMC), LAN (VXI-11/Telnet/             supports multi-touch gestures
  Socket), Pass/Fail, Trigger Out                                                   • Interfaces include: USB Hosts, USB Device (USBTMC), LAN (VXI-11/Telnet/
• Built-in web server supports remote control over the LAN port using a web           Socket), Pass/Fail, Trigger Out
  browser. Supports SCPI remote control commands. Supports external mouse           • Built-in web server supports remote control over the LAN port using a web
  and keyboard                                                                        browser. Supports SCPI remote control commands. Supports external mouse
                                                                                      and keyboard. Supports NTP.
                                                                                                                                                   www.siglent.com 5
  Digital Storage Oscilloscope
SDS1000X-E Series                                                                   SDS1000DL+ / SDS1000CML+ Series
                                                                                    SDS1152CML+ (150 MHz)
SDS1204X-E / SDS1202X-E (200 MHz)
                                                                                    SDS1102CML+ (100 MHz)
SDS1104X-E (100 MHz)
                                                                                    SDS1072CML+ (70 MHz)
                                                                                    SDS1052DL+ (50 MHz)
Features and Benefits:
• Two channel series have one 1 GSa/s ADC, four channel series have two 1
                                                                                    Features and Benefits
   GSa/s ADCs. When all channels are enabled, each channel has a maximum
                                                                                    • 50 MHz, 70 MHz, 100 MHz, 150 MHz bandwidth models
   sample rate of 500 MSa/s. When a single channel per ADC is active, it has
                                                                                    • Real-time sampling rate up to 1 GSa/s, Equivalent-time sampling rate up to
   sampling rate of 1 GSa/s
                                                                                       50 GSa/s
• The newest generation of SPO technology
                                                                                    • Memory Depth up to 2 Mpts
   • Waveform capture rate up to 100,000 wfm/s (normal mode), and
                                                                                    • Trigger types: Edge, Pulse, Video, Slope, Alternate
    400,000 wfm/s (sequence mode)
                                                                                    • Waveform math functions:+, -, *, /, FFT
   • Supports 256-level intensity grading and color display modes
                                                                                    • 6 digits frequency counter
   • Record length up to 14 Mpts
                                                                                    • Supports Multi-language display and embedded online help
   • Digital trigger system
                                                                                    • Screensaver from 1 minute to 5 hours
• Intelligent trigger: Edge, Slope, Pulse Width, Window, Runt, Interval, Time
                                                                                    • Digital filter and waveform recorder function
   out (Dropout), Pattern
                                                                                    • 7 inch TFT-LCD display with 800 * 480 resolution
• Serial bus triggering and decoding (Standard), supports protocols IIC, SPI,
   UART, RS232, CAN, LIN
• Segmented acquisition (Sequence) mode, divides the maximum record length
   into multiple segments (up to 80,000), according to trigger conditions set by
   the user, with a very small dead time segment to capture the qualifying event.
• 1 Mpts FFT
• Math and measurement functions use all sampled data points (up to 14 Mpts)
• MSO, 16 digital channels (four channel series only, optional)
• Search and navigate (four channel series only)
• USB AWG module (four channel series only, optional)
• Bode plot (four channel series only)
www.siglent.com 6
 Handheld Oscilloscope                                                                  Arbitrary Waveform Generator
                                                                                       SDG7000A Series
SHS1000X/SHS800X Series                                                                SDG7102A (1 GHz)
                                                                                       SDG7052A (500 MHz)
SHS1202X (200 MHz)                                                                     SDG7032A (350 MHz)
SHS1102X (100 MHz)
                                                                                       Features and Benefits
SHS820X (200 MHz)                                                                      • Dual channel differential/single-ended output, 16-bit LVDS/LVTTL digital bus
SHS810X (100 MHz)                                                                         output
                                                                                       • High-performance sampling system with 5 GSa/s sample rate and 14 -bit
Features and Benefits                                                                     vertical resolution
• 200 MHz, 100 MHz bandwidth models                                                    • 1 GHz maximum bandwidth
• Sample rate of 1 GSa/s (single-channel), Sample rate of 500 MSa/s (two-              • Generates arbitrary waveform with sample rates of 0.01 Sa/s ~ 2.5 GSa/s,
  channels)                                                                               with maximum memory depth of 512 Mpts, and provides segment editing /
• The Siglent SPO technology                                                              playback functions
  • Waveform capture rates up to 100,000 wfm/s (normal mode) and                       • Generates vector signals with up to 500 MS/s symbol rate
    400,000 wfm/s (sequence mode)                                                      • Generates low jitter pulses with 1 ns minimum pulse width and 500 ps
  • Supports 256-level intensity grading and color temperature display modes
                                                                                          minimum edge
  • Record length up to 12 Mpts
                                                                                       • Up to 1 GHz bandwidth White Gaussian Noise and the bandwidth is adjustable
  • Digital trigger system
                                                                                       • Supports PRBS up to 312.5 Mbps
• Intelligent trigger: Edge, Slope, Pulse Width, Window, Runt, Interval, Time
                                                                                       • The digital bus can output digital signals up to 1 Gbps.
  out (Dropout), Pattern
                                                                                       • Supports analog/digital modulation, sweeping and bursting
• Serial bus triggering and decoding (Standard) for IIC, SPI, UART, CAN, and
                                                                                       • Enhanced dual channel operation functions: inter channel tracking, coupling
  LIN protocols
                                                                                          and copying; Dual channel superposition function; Supports mutual
• Video trigger/HDTV
                                                                                          modulation between channels
• Low background noise with voltage scales from 2 mV/div to 100 V/div
                                                                                       • The 24 Vpp analog output is superimposed with ± 12 Vdc offset to provide a
• 3 one-button shortcuts for Oscilloscope, Multimeter and Recorder functions
                                                                                          maximum output range of ± 24 V (48 V)
• 8 one-button shortcuts for: Run/Stop, Auto Setup, Default, Measure, Cursors,
                                                                                       • High precision Frequency Counter
  Display/Persist, Clear Sweep and Print. More function shortcuts available
                                                                                       • 5-inch capacitive touch screen with resolution of 800x480; Supports
  when combined with the shift button
• Segmented acquisition (Sequence) mode, divides the maximum record length                external mouse and keyboard operation; Supports WebServer to control the
  into multiple segments (up to 80,000), according to trigger conditions set by           instruments remotely
  the user, with a very small dead time segment to capture the qualifying event        • Supports multiple interfaces: 10 MHz In, 10 MHz Out, Trigger In/Out, Markers
• History waveform record (History) function (maximum recorded waveform                   etc
  length is 80,000 frames)                                                             • Supports SCPI command for easy integration into test systems
• Automatic measurement function for 38 parameters as well as Measurement
  Statistics, Zoom, Gating, Math, History and Reference functions
• 1 Mpts FFT. Support Peaks and Markers
• Math and measurement functions use all sampled data points (up to 12 Mpts)
• Math functions (FFT, addition, subtraction, multiplication, division, integration,
  differential, square root)
• Default key can be customized for user settings or factory “defaults”
• Supports Multi-language display and embedded online help
• Security Erase mode
• Search and navigate function
• Includes Recorder mode, including Sample and Measurement Loggers
• 6000 counts Digital Multimeter, Support DCV, ACV, DCI, ACI, Resistance,
  Diode, Capacitance, Continuity test.
• True RMS AC Voltage/Current measurement multimeter
• 5.6-inch TFT-LCD display with 640 * 480 resolution
• Interface types: Isolated USB Host, USB Device (MicroUSB -TMC)
• Supports SCPI remote control commands
• UL2054 certified lithium battery pack, 6900 mAh capacity, external charger
• IP Rating: IP51
• Compliance with UL61010-1, UL61010-2-030, UL61010-2-033
                                                                                                                                                    www.siglent.com 7
 Function/Arbitrary Waveform Generator
SDG6000X Series                                                                 SDG2000X Series
SDG6052X (500 MHz)                                                              SDG2122X (120 MHz)
SDG6032X (350 MHz)                                                              SDG2082X (80 MHz)
SDG6022X (200 MHz)                                                              SDG2042X (40 MHz)
Features and Benefits                                                           Features and Benefits
• Innovative TrueArb and EasyPulse technology                                   • Dual-channel, 120 MHz maximum bandwidth, 20 Vpp maximum output
• Dual-Channel, 500 MHz maximum bandwidth, 20 Vpp maximum output                  amplitude, high fidelity output with 80 dB dynamic range
   amplitude, high fidelity output with 80 dB dynamic range                     • High-performance sampling system with 1.2 GSa/s sampling rate and 16-bit
• High-performance sampling system with 2.4 GSa/s sampling rate and 16-bit        vertical resolution. No detail in your waveforms will be lost
   vertical resolution                                                          • Innovative TrueArb technology, based on a point-by-point architecture,
• Multi-function signal generator, meeting requirements in wide range,             supports any 8 pts~8 Mpts Arb waveform with a sampling rate in range of
   Continuous Wave Generator, Pulse Generator, Function Arbitrary Waveform        1 μSa/s~75 MSa/s
   Generator, IQ Signal Generator (optional), Noise Generator, PRBS Generator   • Innovative EasyPulse technology, capable of generating lower jitter Square or
• Sweep and Burst function                                                         Pulse waveforms, brings a wide range and extremely high precision in pulse
• Harmonics function                                                              width and rise/fall time adjustments
• Waveform Combining function                                                   • Sweep and Burst function; Harmonics mode supported
• Channel Coupling, Copy and Tracking function                                  • 4.3” touch screen display for easier operation
• 196 built-in arbitrary waveforms
• High precision Frequency Counter
• Standard interfaces include: USB Host, USB Device (USBTMC), LAN (VXI-11,
   Socket, Telnet), GPIB (Optional)
• 4.3” touch screen display for easier operation
www.siglent.com 8
 Function/Arbitrary Waveform Generator                                             Programmable Switching DC Power Supply
                                                                                   SPS5000X Series
SDG1000X Series
                                                                                   SPS5161X       (160 V, 7.5 A)            SPS5081X      (80   V,   15   A)
SDG1062X (60 MHz)                                                                  SPS5162X       (160 V, 15 A)             SPS5082X      (80   V,   30   A)
SDG1032X (30 MHz)                                                                  SPS5163X       (160 V, 22.5 A)           SPS5083X      (80   V,   45   A)
Features and Benefits                                                              SPS5164X       (160 V, 7.5 A)            SPS5084X      (80   V,   15   A)
• 150 MSa/s sampling rate, 14-bit vertical resolution, and 16 kpts waveform        SPS5165X       (160 V, 7.5 A)            SPS5085X      (80   V,   15   A)
  length                                                                           SPS5051X       (50 V, 10 A)
• Innovative TrueArb and EasyPulse technology                                      SPS5041X       (40 V, 30 A)
• Special circuit for Square wave function, can generate Square waves up to 60     SPS5042X       (40 V, 60 A)
  MHz with jitter less than 300 ps+0.05 ppm of period                              SPS5043X       (40 V, 90 A)
• Plenty of analog and digital modulation types: AM, DSB-AM, FM, PM, FSK,          SPS5044X       (40 V, 30 A)
  ASK, PSK and PWM, Sweep and Burst functions                                      SPS5045X       (40 V, 30 A)
• Waveform Combining function
• High precision Frequency Counter                                                 Features and Benefits
• Standard interfaces: USB Host, USB Device (USBTMC), LAN (VXI-11)                 • Rated Output Voltage: 40 V, 50 V, 80 V, 160 V
• Optional interface: GPIB                                                         • Rated Output Power: 180 W, 360 W, 720 W, 1080 W
                                                                                   • Wide range of output voltage and current, high efficiency power supply
                                                                                   • CV, CC priority mode selection, better protection of equipment under test
                                                                                   • Load transient recovery time (Load change from 50~100%) <1 ms
                                                                                   • Adjustable slew rate of output voltage and current
                                                                                   • Setting and readback resolution: 1 mV, 1 mA
                                                                                   • User enabled internal output discharge circuit to accelerate the down
                                                                                      programming of the output voltage
                                                                                   • Remote Voltage Sensing
                                                                                   • List function up to 50 steps; can be created from the front panel or by
                                                                                      importing list sequence files from a USB memory device
                                                                                   • External analog voltage and resistor control of voltage or current output
                                                                                   • External voltage and current monitoring output
                                                                                   • OVP, OCP, LPP, OTP protection.
                                                                                   • 2.4-inch OLED high brightness liquid crystal display, 170-degree viewing angle
                                                                                   • Standard Interface: USB, LAN, Analog Control Interface
                                                                                   • Optional Interface: USB-GPIB module
SDG800 Series                                                                      • 1/2, 1/3, 1/6 rack mount size
                                                                                   • Embedded Web Server offers remote control through a web browser without
SDG830 (30 MHz)                                                                       the need for the driver or software
SDG810 (10 MHz)
Features and Benefits
• Advanced DDS technology, 3.5 inch color TFT-LCD
• 125 MSa/s sampling rate,14 bit vertical resolution,16 Kpts max wave length
• 5 types of standard waveforms, built-in 46 types of arbitrary waveforms, sync
  signal output, 1 μHz frequency resolution
• Complete modulation functions: AM,DSB-AM, FM, PM, FSK, ASK, PWM, linear/
  logarithmic sweep and burst
• Innovative EasyPulse technology, can output pulse of low jitter, quick rising/
  falling edge
• Support USB-TMC protocol and SCPI programming command control
• Arbitrary waveform edit software, provides lots of painting method, capable
  of edit complicate waveform quickly and precisely
                                                                                                                                                www.siglent.com 9
  Programmable Linear DC Power Supply                                           Programmable Linear DC Power Supply
SPD3303X Series
SPD3303X-E (10 mv, 10 mA)
SPD3303X (1 mv, 1 mA)
                                                                              SPD1000X Series
Features and Benefits
• 3 independent controlled and isolated outputs, 32 V/3.2 A×2,
                                                                              SPD1168X (16 V/8 A)
   2.5 V/3.3 V/5 V/3.2 A×1, total 220 W
                                                                              SPD1305X (30 V/5 A)
• 5 digits Voltage, 4 digits Current Display, Minimum Resolution: 1 mV/1 mA
  (SPD3303X)                                                                  Features and Benefits
• Supports front panel timing output functions
                                                                              • Single path high-precision programmable voltage output
• 4.3 inch true color TFT- LCD 480x272 display
                                                                                 16 V/8 A, total power up to 128 W
• 3 types of output modes: independent, series, parallel
                                                                                 30 V/5 A, total power up to 150 W
• 100 V/120 V/220 V/230 V compatible design to meet the needs of different
                                                                              • Stable, reliable, Low ripple and noise:≤ 350 uVrms/3 mVpp; < 2 mArms
  power grids                                                                 • Fast transient response time: < 50 μs
• Intelligent temperature-controlled fan, effectively reducing noise
                                                                              • 5 digit Voltage, 4 digit Current Display, Minimum Resolution: 1 mV/1 mA
• Clear graphical interface, with the waveform display function
                                                                              • Supports front panel timing output functions
• Internal 5 groups of system parameter save/recall, supports data storage
                                                                              • 2.8 inch true color TFT- LCD 240 *320 display
   space expansion                                                            • 2 types of output modes:Two-wire output mode, 4-wire compensation output
• Provides PC software: Easypower, supports SCPI, LabView driver
                                                                                 mode, Maximum compensation voltage 1 V
                                                                              • 100/120/220/230 V compatible design to meet the needs of different power
                                                                                 grids
                                                                              • Intelligent temperature-controlled fan reduces noise
                                                                              • Clear graphical interface, with the waveform display function
                                                                              • Internal 5 groups of system parameter save/recall
                                                                              • Includes PC software: Easypower, supports SCPI, LabView driver
SPD3303C Series
SPD3303C (10 mv,10 mA)
Features and Benefits
• 3 independent controlled and isolated output: 32 V/3.2 A×2, 2.5 V/3.3 V/
   5 V/3.2 A×1, total power 220 W
• Resolution: 10 mV/10 mA
• Supports panel timing output functions
• LED display; 32 V full scale, 4 digits; 3.2 A full scale, 3 digits
• 100 V/120 V/220 V/230 V compatible design, to meet the needs of different
   power grids
• Intelligent fan for temperature control, effectively reduces noise
• Five groups of internal system parameter storage. Supports data storage
   space expansion
• Supports SCPI commands & USB device interface. Includes PC software
www.siglent.com 10
  Programmable DC Electronic Load                                               Digital Multimeter
SDL1000X Series
                                                                            SDM3065X Series
SDL1030X/X-E (300 W)
SDL1020X/X-E (200 W)                                                        SDM3065X
                                                                            SDM3065X-SC (with Scanner Card)
Features and Benefits
                                                                            Features and Benefits
• SDL1020X (Single channel ): DC 150 V/30 A, total power up to 200 W        •   4.3” TFT-LCD, 480*272
• SDL1030X (Single channel ): DC 150 V/30 A, total power up to 300 W        •   Real 6½ digits readings resolution (2,200,000 counts)
• 4 static modes / Dynamic mode: CC/CV/CR/CP                                •   1Gb Nand flash size, Mass storage configuration files and data files
• CC Dynamic mode: Continuous, pulsed, toggled                              •   True-RMS AC Voltage and AC Current measuring
• CC Dynamic mode: 25 kHz, CP Dynamic mode: 12.5 kHz, CV Dynamic mode:      •   Supports double display, Chinese and English Menu
   0.5 Hz                                                                   •   File management (support for U-disc and local storage)
• Measuring speed of voltage and current: up to 500 kHz                     •   Built-in cold terminal compensation for thermocouple
• Adjustable current rise time range: 0.001 A/us~2.5 A/us                   •   Comes with easy, converient and flexble any sensor measurement control
• Min. readback resolution: 0.1 mV, 0.1 mA                                      software: EasyDMM
• Short-circuit, Battery test, CR-LED mode, and factory test functions      •   Standard interfaces: USB Device, USB Host, LAN (Optional Accessories: USB-
• 4-wire SENSE compensation mode function                                       GPIB Adapter)
• List function supports editing as many as 100 steps                       •   Scanner Card SC1016 (Only for SDM3065X-SC)
• Program function supports 50 groups of steps                              •   Built-in Hlep system makes information acquisition easier
• OCP, OVP, OPP, OTP and LRV protection                                     •   Support remote control operation via SCPI commands. Compatible with
• External analog control                                                       commands of other main stream multimeters
• Voltage, Current monitoring via 0-10 V                                    •   Supports intelligent management system for laboratory based on BS
• 3.5 inch TFT-LCD display, capable of displaying multiple parameters and       framework and LAN
   states simultaneously
• Built-in RS232/USB/LAN communication interface, USB-GPIB module
   (optional)
• Waveform trend chart and ease-to-use file storage and call functions
• Includes PC software: Supports SCPI, LabView driver
                                                                            SDM3055 Series
                                                                            SDM3055
                                                                            SDM3055-SC (with Scanner Card)
                                                                            Features and Benefits
                                                                            • Real 5½ digits readings resolution ( 240, 000 counts )
                                                                            • Up to 150 rdgs/s measurement speed
                                                                            • True-RMS AC Voltage and AC Current measuring
                                                                            • 1 Gb Nand flash size, Mass storage configuration files and data files
                                                                            • Built-in cold terminal compensation for thermocouple temperature
                                                                                measurements
                                                                            • With easy, convenient and flexible PC software: EasyDMM
                                                                                standard interfaces: USB Host, LAN ( Optional Accessories USB-GPIB Adapter )
                                                                            • Scanner Card SC1016 ( Only for SDM3055-SC )
                                                                            • Support remote control operation via SCPI commands.Compatible with
                                                                                commands of main stream multimeters
                                                                                                                                            www.siglent.com 11
  Digital Multimeter                                                       Vector Network Analyzer
SDM3045X Series                                                           SNA5000A Series
                                                                          SNA5032A        (100 kHz~26.5 GHz)
SDM3045X                                                                  SNA5022A        (100 kHz~13.5 GHz)
                                                                          SNA5014A        (9 kHz~8.5 GHz)
Features and Benefits                                                     SNA5004A        (9 kHz~4.5 GHz)
• Real 4½ digit (60000 counts) readings resolution
• Up to 150 rdgs/s measurement speed
                                                                          SNA5012A        (9 kHz~8.5 GHz)
• True-RMS AC Voltage and AC Current measuring
                                                                          SNA5002A        (9 kHz~4.5 GHz)
• 1 Gb NAND flash size, Mass storage configuration files and data files
• Built-in cold terminal compensation for thermocouple
                                                                          Features and Benefits:
                                                                          • Frequency range: 9 kHz~8.5 GHz and 100 kHz~26.5 GHz
• With easy, convenient and flexible PC software: EasyDMM
                                                                          • Frequency resolution: 1 Hz
• Standard interface: USB Device, USB Host, LAN (Optioanal Accessories:
                                                                          • Level resolution: 0.05 dB
  USB-GPIB Adapter)
                                                                          • Range of IFBW: 10 Hz~3 MHz
• USB & LAN remote interfaces support common SCPI command set.
                                                                          • Setting range of output level: -55 dBm ~ +10 dBm
  Compatible with other popular DMMs on the market
                                                                          • Dynamic range: 125 dB
                                                                          • Types of calibration: Response calibration, Enhanced Response calibration,
                                                                            Full-one portcalibration, Full-two port calibration, Full-three port calibration,
                                                                            Full-four port calibration, TRL calibration
                                                                          • Types of measurement: Scattering-parameter measurement,
                                                                            differential-parameter measurement,receiver measurement, time-domain
                                                                            parameter analysis, limit test, ripple test, impedance conversion, fixture
                                                                            simulation, adapter removal/insertion, enhanced time-domain parameter
                                                                            analysis (TDR), spectrum analysis, frequency offset, scalar mixer measurement
                                                                          • Support Bias-Tees
                                                                          • Interface: LAN, USB Device, USB Host(USB-GPIB)
                                                                          • Remote control: SCPI/Labview/IVI based on USB-TMC/VXI-11/Socket/Telnet/
                                                                            WebServer
                                                                          • 12.1-inch touch screen
                                                                          • Video output: HDMI
www.siglent.com 12
  Portable Vector Network Analyzer                                               Switch Matrix
SHN900A Series                                                                   SSM5000A Series
SHN926A (30 kHz~26.5 GHz)                                                        SSM5342A           (100 kHz~26.5 GHz)
SHN920A (30 kHz~20 GHz)                                                          SSM5321A           (100 kHz~26.5 GHz)
SHN914A (30 kHz~14 GHz)                                                          SSM5144A           (9 kHz~9 GHz)
                                                                                 SSM5142A           (9 kHz~9 GHz)
Features and Benefits:                                                           SSM5124A           (9 kHz~9 GHz)
• Standard VNA and CAT mode, optional SA mode                                    SSM5122A           (9 kHz~9 GHz)
• Frequency range: 30 kHz - 26.5 GHz
• Frequency resolution: 1 Hz
• Level resolution: 0.05 dB
                                                                                 Features and Benefits:
• Range of IFBW: 10 Hz~3 MHz                                                     • Characteristic impedance: 50 Ω
• Setting range of output level: -45 dBm ~ +10 dBm                               • Highest frequency: 9 GHz (or 26.5 GHz)
• Dynamic range: 110 dB(Typ.)                                                    • Maximum number of input ports: 4
• Types of calibration: Response calibration, Enhanced Response calibration,     • Maximum number of output ports: 24
  Full-one port calibration, Full-two port calibration, TRL calibration          • RF connector: 3.5 mm female
• Types of measurement: Scattering-parameter measurement, differential-          • Maximum input power: 20 dBm
  parameter measurement, receiver measurement, time-domain parameter             • Maximum input DC voltage: 35 V
  analysis, limit test, ripple test, impedance conversion, fixture simulation,   • Interface: LAN, USB Device, Direct Control (in), Direct Control (out) Screen
  adapter removal/insertion, spectrum analysis frequency offset, scalar mixer      size: 2.4-inch
  measurement, pulse measurement
• Internal Bias-Tee connections
• Support GPS, Time and Location Information Saving
• Interface: LAN, USB Device, USB Host (USB-GPIB)
• Remote control: SCPI/ Labview/ IVI based on USB-TMC / VXI-11 / Socket /
  Telnet / WebServer
• 8.4-inch touch screen, Mouse, Keyboard
• Typical working time 4 hours, 3.2 kg net weight
                                                                                                                                           www.siglent.com 13
  Mechanical Switch                                            Spectrum Analyzer
SSU5000A Series                                               SSA5000A Series
SSU5504A       (DC~50 GHz)                                    SSA5085A (9 kHz~26.5 GHz)
SSU5503A       (DC~50 GHz)                                    SSA5083A (9 kHz~13.6 GHz)
SSU5502A       (DC~50 GHz)
SSU5501A       (DC~50 GHz)                                    Features and Benefits:
SSU5266A       (DC~26.5 GHz)                                  • Spectrum Analyzer Frequency Range from 9 kHz up to 13.6 GHz/26.5 GHz
SSU5265A       (DC~26.5 GHz)                                  • -165 dBm/Hz Displayed Average Noise Level (Typ.)
                                                              • -105 dBc/Hz@1 GHz,10 kHz offset SSB Phase Noise (Typ.)
SSU5264A       (DC~26.5 GHz)
                                                              • 25 MHz/40 MHz Analysis Bandwidth
SSU5263A       (DC~26.5 GHz)
                                                              • 100% POI 7.20 μs, Dynamic Range 60 dB, Multi-view for Density, Spectrogram
SSU5262A       (DC~26.5 GHz)
                                                                and PvT
SSU5261A       (DC~26.5 GHz)                                  • Channel power, ACPR, OBW, Harmonic, TOI measurement etc.
SSU5184A       (DC~18 GHz)                                    • Analog Modulation Analysis and Vector Digital Modulation Analysis
SSU5183A       (DC~18 GHz)                                    • 12.1 inch Multi-Touch Screen, HDMI output
SSU5182A       (DC~18 GHz)                                    • Web Browser Remote Control on PC and Mobile Terminals and File Operation
SSU5181A       (DC~18 GHz)
Features and Benefits:
• Maximum frequency: 18 GHz/ 26.5 GHz/ 50 GHz
• 1 to 4 SPDT switches or 1 to 2 SP6T switch configurations
• SCPI Controllable via VISA and EasySSU software
• USB Connectivity
• Size: WxHxD=153x62.4x137.5 mm
• RF connector: SMA female or 2.4 mm female
www.siglent.com 14
  Spectrum Analyzer                                                          Real-Time Spectrum Analyzer
SSA3000X Plus Series                                                         SSA3000X-R Series
SSA3075X      Plus     (9   kHz~7.5 GHz)                                     SSA3075X-R (9 kHz~7.5 GHz)
SSA3032X      Plus     (9   kHz~3.2 GHz)                                     SSA3050X-R (9 kHz~5.0 GHz)
SSA3021X      Plus     (9   kHz~2.1 GHz)                                     SSA3032X-R (9 kHz~3.2 GHz)
SSA3015X      Plus     (9   kHz~1.5 GHz)
                                                                             Features and Benefits:
Features and Benefits:                                                       • -165 dBm/Hz Displayed Average Noise Level (Typ.)
• -165 dBm/Hz Displayed Average Noise Level (Typ.)                           • -98 dBc/Hz.@10 kHz Offset Phase Noise (1 GHz, Typ.)
• -98 dBc/Hz.@10 kHz Offset Phase Noise (1 GHz, Typ.)                        • Level Measurement Uncertainty < 0.7 dB (Typ.)
• Level Measurement Uncertainty < 0.7 dB (Typ.)                              • 1 Hz Minimum Resolution Bandwidth (RBW)
• 1 Hz Minimum Resolution Bandwidth (RBW)                                    • Preamplifier Standard
• Preamplifier Standard                                                      • Tracking Generator Standard
• Tracking Generator                                                         • Up to 40 MHz Real Time Analysis Bandwidth
• Analog and Digital Signal Modulation Analysis Mode (Opt.)                  • 100% POI 7.20 μs, Dynamic Range 60 dB
• EMI Filter and Quasi-Peak Detector Kit(Opt.)                               • Multi-view for Density, Spectrogram, PvT, and multi trigger and FMT
• 10.1 lnch Multi-Touch Screen , Mouse and Keyboard supported                • Modulation Analysis up to 40 MHz BW (Opt.)
• Web Browser Remote Control on PC and Mobile Terminals and File Operation   • EMI Filter and Quasi-Peak Detector Kit(Opt.)
                                                                             • 10.1 inch Multi-Touch Screen , Mouse and Keyboard supported
                                                                             • Web Browser Remote Control on PC and Mobile Terminals and File Operation
SSA3000X Series
SSA3032X (9 kHz~3.2 GHz)
SSA3021X (9 kHz~2.1 GHz)
Features and Benefits:
• -161 dBm/Hz Displayed Average Noise Level (Typ.)
• -98 dBc/Hz @10 kHz Offset Phase Noise (1 GHz, Typ.)
• Total Amplitude Accuracy < 0.7 dB
• 1 Hz Minimum Resolution Bandwidth (RBW)
• Preamplifier Standard
• Up to 3.2 GHz Tracking Generator (Standard)
• Reflection Measurement Kit (Opt.)
• Advanced Measurement Kit (Opt.)
• EMI Pre-compliance Measurements Kit (Opt.)
• 10.1 lnch WVGA (1024x600) Display
                                                                                                                                       www.siglent.com 15
  Portable Spectrum Analyzer                                                       Spectrum & Vector Network Analyzer
SHA850A Series                                                                     SVA1000X Series
SHA852A (9 kHz~7.5 GHz)                                                            SVA1075X (9 kHz~7.5 GHz)
SHA851A (9 kHz~3.6 GHz)                                                            SVA1032X (9 kHz~3.2 GHz)
                                                                                   SVA1015X (9 kHz~1.5 GHz)
Features and Benefits:
• Spectrum Analyzer Frequency Range from 9 kHz up to 7.5 GHz, -165 dBm/            Features and Benefits:
  Hz Displayed Average Noise Level (Typ.), -104 dBc/Hz.@10 kHz Offset Phase        • Vector Network Analyzer Frequency Range from 100 kHz up to 7.5 GHz
  Noise (1 GHz, Typ.), 1 Hz up to 10 MHz Minimum Resolution Bandwidth (RBW),       • -165 dBm/Hz Displayed Average Noise Level (Typ.)
  Preamplifier and independent signal source up to 7.5 GHz, GPS positioning and    • -98 dBc/Hz.@10 kHz Offset Phase Noise (1 GHz, Typ.)
  logging                                                                          • Level Measurement Uncertainty < 0.7 dB (Typ.)
• Cable and Antenna Test Frequency Range from 100 kHz up to 7.5 GHz,               • 1 Hz Minimum Resolution Bandwidth (RBW)
  Distance To Fault and Time Domain Analysis                                       • Preamplifier Standard
• Vector Network Analyzer, Bias out up to 32VDC                                    • Tracking Generator Standard
• Typical working time 4 hours, 3.2 kg net weight, 8.4 lnch Multi-Touch Screen ,   • Distance To Fault (Opt.)
  Mouse and Keyboard supported                                                     • Analog and Digital Signal Modulation Analysis Mode (Opt.)
                                                                                   • EMI Filter and Quasi-Peak Detector Kit(Opt.)
                                                                                   • Advanced Measurement Kit (Opt.)
                                                                                   • 10.1 lnch Multi-Touch Screen , Mouse and Keyboard supported
                                                                                   • Web Browser Remote Control on PC and Mobile Terminals and File Operation
www.siglent.com 16
  RF Signal Generator                                                          RF Signal Generator
SSG6000A Series
SSG6087A (CW MODE 100 kHz ~ 40 GHz)                                          SSG5000X Series
SSG6085A (CW MODE 100 kHz ~ 20 GHz)
SSG6083A (CW MODE 100 kHz ~ 13.6 GHz)                                        SSG5060X (CW MODE 9 kHz ~ 6 GHz)
Features and Benefits                                                        SSG5040X (CW MODE 9 kHz ~ 4 GHz)
• Frequency up to 13.6 GHz/ 20 GHz/ 40GHz                                    SSG5060X-V (CW MODE 9 kHz ~ 6 GHz /
• 0.01 Hz frequency setting resolution                                       IQ MODE 10 MHz ~ 6 GHz)
• Level setting range: -130 dBm ~ 24 dBm                                     SSG5040X-V (CW MODE 9 kHz ~ 4 GHz /
• Phase Noise: -135 dBc / Hz @ 1 GHz, 20 kHz offset (typ.)                   IQ MODE 10 MHz ~ 4 GHz)
• Level error ≤ 0.7 dB (typ.)
• Provides AM analog modulation with internal, external or Int+Ext source    Features and Benefits
• Single pulse, double pulse and pulse train generator (option)              • Frequency up to 4 GHz/6 GHz
• The power meter control kit can easily use the power meter to measure      • 0.001 Hz frequency setting resolution
   power, control power output and correct line loss 5 inch TFT capacitive   • High output power up to +26 dBm (typ.)
   touch screen, mouse and keyboard supported                                • Phase Noise: -120 dBc/ Hz @ 1 GHz, 20 kHz offset (typ.)
• Web browser remote control on PC and mobile terminals                      • User flatness correction with power sensor to correct the cable loss
• Standard interface includes USB Host, USB Device (USB TMC), LAN (VXI-11,   • Provides AM, FM, PM analog modulation with internal, external or Int+Ext
   Socket, Telnet). Optional interface: GPIB                                    source
• Standard OCXO and step attenuator (0 to 110 dB, 10 dB step)                • Single pulse, double pulse and Pulse train generator (option)
                                                                             • Internal IQ modulation with 150 MHz modulation bandwidth with perfect in-
                                                                                factory calibration
                                                                             • Internal include some digital communication stand file such as 5G-NR, LTE,
                                                                                WCDMA, WLAN, and playback them
                                                                             • Internal Custom mode generate common IQ signal such as QAM, FSK, ASK,
                                                                                MSK
                                                                             • Analog differential I/Q outputs
                                                                             • External analog I/Q input
                                                                             • USB-power meter measurement
                                                                             • 5inch TFT capacitive touch screen, mouse and keyboard supported
                                                                             • Web browser remote control on PC and mobile terminals
                                                                             • Standard interface included USB Host, USB Device (USB TMC), LAN (VXI-11,
                                                                                Socket, Telnet). Optional interface: GPIB
SSG5000A Series
SSG5085A (CW MODE 9 kHz ~ 20 GHz)
SSG5083A (CW MODE 9 kHz ~ 13.6 GHz)
Features and Benefits
• Frequency up to 13.6 GHz / 20 GHz
• 0.001 Hz frequency setting resolution
• Level setting range: -130 dBm ~ 25 dBm
• Phase Noise: -120 dBc / Hz @ 1 GHz, 20 kHz offset (typ.)
• Level error ≤ 0.7 dB (typ.)
• Provides AM, FM, PM analog modulation with internal, external or Int+Ext
   source
• Single pulse, double pulse and pulse train generator (option)
• The power meter control kit can easily use the power meter to measure
   power, control power output and correct line loss
• 5 inch TFT capacitive touch screen, mouse and keyboard supported
• Web browser remote control on PC and mobile terminals
• Standard interface includes USB Host, USB Device (USB TMC), LAN (VXI-11,
   Socket, Telnet). Optional interface: GPIB
                                                                                                                                          www.siglent.com 17
  RF Signal Generator
SSG3000X Series
SSG3032X (CW MODE 9 kHz~3.2 GHz)
SSG3021X (CW MODE 9 kHz~2.1 GHz)
SSG3032X-IQE (IQ MODE 10 MHz~3.2 GHz)
SSG3021X-IQE (IQ MODE 10 MHz~2.1 GHz)
Features and Benefits
• 0.01 Hz frequency setting resolution
• Level output from -110 dBm to +13 dBm
• Maximum level up to +20 dBm (typ.)
• Phase Noise: -110 dBc/ Hz @ 1 GHz , 20 kHz offset (typ.)
• Level accuracy ≤0.7 dB (typ.)
• Provides AM, FM, &PM analog modulation with internal, external or Int+Ext
  source
• Pulse modulation, on/off ratio ≥70 dBc
• Pulse train generator (option)
• External IQ modulation with SDG6000X as the baseband IQ signal
• USB-power meter measurement
• 5 inch TFT capacitive touch screen, mouse and keyboard supported
• Web browser remote control on PC and mobile terminals
• Standard interface include USB Host, USB Device (USB TMC), LAN (VXI-11,
   Socket, Telnet). Optional interface: GPIB
www.siglent.com 18
Probes and Accessories
Type            Model      Picture   Specifications
                                     PB470, 70 MHz bandwidth
                PB470
                                     PP510, 100 MHz bandwidth
                PP510
                                     PP215, 200 MHz bandwidth
                PP215
                                     1 X/10 X decay, 1 M/10 Mohm, 300 V/600 V
Passive Probe
                                     10X CAT II 1000 V, CAT III 600 V, 250 MHz-bandwidth, SHS1000 handheld
                PB925
                                     oscilloscope option
                SAP1000              Active Probe, 1 GHz
                SAP2500              Active Probe, 2.5 GHz
Active Probe
                SAP2500D             Differential Active Probe, 2.5 GHz
                SAP5000D             Differential Active Probe, 5 GHz
                                     Bandwidth: DC-600 kHz ; Current Range: L (50 mA~10 A Peak),
                                     H(1 A~100 A Peak); Attenuation accuracy L (0.1 V/A), H (0.01 V/A); Typical
                CPL5100              DC precision: L (3%±50 mA), H(500 mA~40 A Peak : 4%±50 mA; 4 0A~100
                                     A Peak : ±15% Maximum); Rise Time: ≤583 ns; Operating voltage RMS:
                                     CATI 600 V CATII 600 V CATIII 300 V; 9 V alkaline layer-built battery/ 15H
                                     Bandwidth: 100 kHz; Maximum continuous current 20 Arms; Peak current 60
                                     A; Switching ratio: 50 m /A; 5 mV/A;
                CP4020
                                     DC measurement accuracy: 50 mV/A (0.4 A-10 ApK) ± 2%; 5 mV/A
                                     (1 A-60 ApK)±2%; 9 V battery-powered
                                     Bandwidth: 1 MHz; Maximum continuous current 50 Arms;
                                     Peak current 140 A; Switching ratio: 500 mV/A; 50 mV/A;
Current Probe   CP4050               DC measurement accuracy: 500 mV/A (20 mA-14 ApK) ±3%±20 mA;
                                     50 mV/A (200 mA-100 ApK )±4%± 200 mA;
                                     50 mV/A (100 A-140 ApK)±15% max; 9 V battery-powered
                                     Bandwidth: 150 KHz; Maximum continuous current 70 Arms; Peak current
                                     200 A; Switching ratio: 50 mV/A; 5 mV/A;
                CP4070
                                     DC measurement accuracy: 50 mV/A(0.4A-10ApK)±2%; 5 mV/A
                                     (1 A-200 ApK)±2%; 9 V battery-powered
                                     Bandwidth: 300 kHz; Maximum continuous current 70 Arms; Peak current
                                     200 A;Switching ratio:100 mV/A;10 mV/A;
                CP4070A              DC measurement accuracy:100 mV/A (50 mA-10 ApK) ±3%±50 mA;
                                     10 mV/A (500 mA-40 ApK) ±4%±50 mA;
                                     10 mV/A (40 A-200 ApK) ±15% max; 9 V battery-powered
                                                                                               www.siglent.com 19
 Type                Model      Picture   Specifications
                                          Frequency is determined by oscilloscope. Isolated USB function/arbitrary
 USB AWG
                     SAG1021I             waveform generator, 125 Msa/s, 16 kpts Arb Wave Length, Insulation Voltage,
 Module
                                          ±42 Vpk(Hardware)
                     BAG-H2               Soft Carry Case for SHA850A, SHN900A
                                          Soft Carry Case for SDS1000DL+/CML+, SDS1000X, SDS1000X-E, SDS2000X-E
 Carry Bag           BAG-S1
                                          Series
                                          Soft Carry Case for SDS2000X, SDS2000X Plus, SDS2000X HD, SDS5000X,
                     BAG-S2
                                          SSA3000X, SSA3000X Plus, SVA1000X, SSA3000X-R
                                          Bandwidth: 50 MHz; Maximum continuous current 30 Arms; Peak current 50 A;
                                          Switching ratio: 5 A/30 A;
                     SCP5030
                                          Accuracy: 5 A(±1%±1 mA); 30 A(±1%±10 mA); Powered by oscilloscope via
                                          SAPBUS
                                          Bandwidth: 100 MHz; Maximum continuous current 30 Arms; Peak current 50
                                          A; Switching ratio: 5 A/30 A;
                     SCP5030A
                                          Accuracy: 5 A(±1%±1 mA); 30 A(±1%±10 mA); Powered by oscilloscope via
                                          SAPBUS
                                          Bandwidth: 12 MHz; Maximum continuous current 150 Arms; Peak current
                                          300 A; Switching ratio: 30 A/150 A;
                     SCP5150
                                          Accuracy: 30 A(±1%±10 mA); 150 A(±1%±100 mA); Powered by oscilloscope
                                          via SAPBUS
                                          Bandwidth: 2 MHz; Maximum continuous current 500 Arms; Peak current 750
                                          A; Switching ratio: 75 A/500 A;
                     SCP5500
                                          Accuracy: 75 A(±1%±10 mA); 500 A(±1%±100 mA); Powered by oscilloscope
                                          via SAPBUS
 Current Probe
                                          Bandwidth: 50 MHz; Maximum continuous current 30 Arms; Peak current 50 A;
                                          Switching ratio: 5 A/30 A;
                     CP6030
                                          Accuracy: 5 A(±1%±1 mA); 30 A(±1%±10 mA); Standard DC12 V/1 A power
                                          adapter
                                          Bandwidth: 100 MHz; Maximum continuous current 30 Arms; Peak current 50
                                          A; Switching ratio: 5 A/30 A;
                     CP6030A
                                          Accuracy: 5 A(±1%±1 mA); 30 A(±1%±10 mA); Standard DC12 V/1 A power
                                          adapter
                                          Bandwidth: 12 MHz; Maximum continuous current 150 Arms; Peak current
                                          300 A; Switching ratio: 30 A/150 A;
                     CP6150
                                          Accuracy: 30 A(±1%±10 mA); 150 A(±1%±100 mA); Standard DC12 V/1 A
                                          power adapter
                                          Bandwidth: 5 MHz; Maximum continuous current 500 Arms; Peak current 750
                                          A; Switching ratio: 75 A/500 A;
                     CP6500
                                          Accuracy: 75 A(±1%±10 mA); 500 A(±1%±100 mA); Standard DC12 V/1 A
                                          power adapter
www.siglent.com 20
Type            Model      Picture   Specifications
                                     Bandwidth: 50 MHz; Maximum continuous current 30 Arms; Peak current 50 A;
                                     Switching ratio: 5 A/30 A;
                CP6030
                                     Accuracy: 5 A(±1%±1 mA); 30 A(±1%±10 mA); Standard DC12 V/1 A power
                                     adapter
                                     Bandwidth: 100 MHz; Maximum continuous current 30 Arms; Peak current 50
                                     A; Switching ratio: 5 A/30 A;
                CP6030A
                                     Accuracy: 5 A(±1%±1 mA); 30 A(±1%±10 mA); Standard DC12 V/1 A power
                                     adapter
Current Probe
                                     Bandwidth: 12 MHz; Maximum continuous current 150 Arms; Peak current
                                     300 A; Switching ratio: 30 A/150 A;
                CP6150
                                     Accuracy: 30 A(±1%±10 mA); 150 A(±1%±100 mA); Standard DC12 V/1 A
                                     power adapter
                                     Bandwidth: 5 MHz; Maximum continuous current 500 Arms; Peak current 750
                                     A; Switching ratio: 75 A/500 A;
                CP6500
                                     Accuracy: 75 A(±1%±10 mA); 500 A(±1%±100 mA); Standard DC12 V/1 A
                                     power adapter
                                     Bandwidth: 50 MHz; Rise Time ≤7 ns; DC Accuracy ±2%; Max Input: 600 V
                                     CATIII, 1000 V CATII; Max Differential Test Voltage (DC + Peak AC): 50 X:
                DPB1300
                                     ±130 V, 500 X: ±1300 V. Input impedance/capacitance: 5 MΩ/<4 pF(Single-
                                     ended), 10 MΩ/< 2 pF(Two inputs); DC 12 V/1.2 A Power
                                     Bandwidth: 50 MHz; Maximum input differential voltage 800 V (DC + Peak
                DPB4080              AC); Range selection (attenuation ratio):10 X/100 X; Accuracy: ±1%;
                                     Standard DC 9 V/1 A power adapter
                                     Bandwidth: 70 MHz; Maximum input differential voltage 1500 V (DC +
                DPB5150              Peak AC); Range selection (attenuation ratio): 50 X/500 X; Accuracy: ±2%;
                                     Standard 5 V/1 A USB power adapter
High Voltage
Differential
Probe
                                     Bandwidth: 100 MHz; Maximum input differential voltage 1500 V (DC +
                DPB5150A             Peak AC); Range selection (attenuation ratio): 50 X/500 X; Accuracy: ±2%;
                                     Standard 5 V/1 A USB power adapter
                                     Bandwidth: 70 MHz; Maximum input differential voltage 7000 V (DC + Peak
                DPB5700              AC); Range selection (attenuation ratio): 100 X/1000 X; Accuracy: ±2%;
                                     Standard 5 V/1 A USB power adapter
                                     Bandwidth: 100 MHz; Maximum input differential voltage 7000 V (DC + Peak
                DPB5700A             AC);Range selection (attenuation ratio): 100 X/1000 X; Accuracy: ±2%;
                                     Standard 5 V/1 A USB power adapter
High Voltage                         Bandwidth: 40 MHz; Maximum input differential voltage DC: 10 kV; AC(rms):
                HPB4010
Probe                                7 kV(sine); AC(Vpp): 20 kV(Pulse); attenuation ratio1: 1000; Accuracy: ≤3%
Logic Probe     SPL2016              Logic Probe, 16-channel, 500 MSa/s
                                                                                               www.siglent.com 21
 Type                Model               Picture   Specifications
                                                   MSO function hardware for SDS2000X-E oscilloscope, 16-channel, 500 MSa/s,
 Logic Analyzer      SLA1016
                                                   14 Mpts
                                                   Three magnetic field near-field probes and one electric field near field probe;
 Near-Field                                        Frequency range: 30 MHz~3 GHz; resolution 25 mm; distinguished within
                     SRF5030T
 Probe                                             10 cm range of the magnetic field; for EMI radiation interference and the
                                                   intensity detector
 Deskew Fixture      DF2001A                       Deskew fixture for voltage and current probes
                     N-BNC-2L                      N-BNC cable, 2 GHz bandwidth
                     N-N-6L                        N-N cable, 6 GHz bandwidth
                     N-SMA-6L                      N-SMA cable, 6 GHz bandwidth
                     N-N-18L                       N(M)-N(M) cable, 18 GHz
                     N-SMA-18L                     N(M)-SMA(M) cable, 18 GHz
 Cable               SMA-SMA-18L                   SMA(M)-SMA(M) cable, 18 GHz
                     SMA-SMA-26L                   SMA(M)-SMA(M) cable, 26 GHz
                     SMAF-SMA-26L                  SMA(F)-SMA(M) cable, 26 GHz
                     2.92F-2.92F-40A               2.92 mm Female - 2.92 mm Female adaptor, 40 GHz
                     V26-N35MN35F-25IN             NMD 3.5 mm male - NMD 3.5 mm female; 26.5 GHz; length 25''/635 mm
                     V26-N35FA35F-25IN             NMD 3.5 mm female - APC 3.5 mm female; 26.5 GHz; length 25''/635 mm
www.siglent.com 22
Type             Model            Picture   Specifications
GPIB             USB-GPIB                   USB-GPIB Adapter, USB Device expanded into GPIB interface
Isolated Front                              USB 5V power supply, plug and play, the maximum input voltage 600Vp-p,
                 ISFE
End                                         floating test. Work with oscilloscopes
STB Test board   STB-3                      For experimental teaching and product demos
                 FX-USB2                    USB 2.0 test fixture
Test fixture     FX-ETH                     100Base-TX & 1000Base-T compliance test fixture
                 FX-AMETH                   100Base-T1 & 1000Base-T1 compliance test fixture
                                            Rackmount kit for two intruments ,SDG800, SDG1000X, SDG2000X,
                 SDG-2-RMK                  SDG5000,SDG6000X series generators and SDM digital multimeters;
                                            Height 3U
                                            Rackmount kit , compatible with the SDS800X HD, SDS1000X-E, SDS1000X-U,
                 SDS1X-E-RMK
                                            SDS2000X-E model; Height 4U
                                            Rackmount kit, compatible with SDG800, SDG1000X, SDG2000X, SDG5000,
                 SDG-RMK                    SDG6000X series generators and SDM digital multimeters, SDL1000X load;
                                            Height 3U
Rack Mount
                                            Rackmount kit , compatible with the SSA3000X, SSA3000X Plus, SVA1000X,
                 SSA-RMK
                                            SSA3000X-R model; Height 6U
                 SSG-RMK                    Rack Mount kit; SSG3000X, SSG5000X, SSG5000A, SDG7000A; Height 3U
                                            Rack Mount kit for SDS1000X HD, SDS2000X HD, SDS3000X HD; Height
                 SDS2000 HD-RMK
                                            6U(exactly 260 mm)
                                                                                                    www.siglent.com 23
 Type                Model          Picture   Specifications
                     SPD3000-RMK              Rackmount kit , compatible with the SPD3000X/X-E/D/S/C models, Height 4U
                     SPS5000X-RMK             SPS5000X EIA Standard rack, Height 3U
                                              Rackmount kit is designed for use with only one instrument, is compatible
                     SDS2000-RMK
                                              with the SDS2000,SDS2000X, SDS2000X Plus series Oscilloscope; Height 6U
 Rack Mount
                     SDS5000X-RMK             Rack Mount kit for SDS5000X; Height 6U
                     SDS6000-RMK              Rack Mount kit for SDS6000A, SNA5000A, SSA5000A; Height 7U
                     SSG6000A-RMK             Rack Mount kit; SSG6000A; Height 2U
                                              Mechanical Calibration Kit: Open (M), Short (M), Match (M,50), Through (F-F),
                     F503ME
                                              4.5 GHz
                     F503FE                   Mechanical Calibration Kit: OSLT, DC - 4.5 GHz, N-Female connector
                     F504MS                   Mechanical Calibration Kit: OSLT, DC - 9 GHz, N-Male connector
                     F504FS                   Mechanical Calibration Kit: OSLT, DC - 9 GHz, N-Female connector
                     F504TS                   Mechanical Calibration Kit: OSLT, DC - 9 GHz, N-Male and Female connector
                     F505TS                   Mechanical Calibration Kit: OSLT, DC - 18 GHz, N-Male and Female connector
 VNA Calibration
 Kit
                                              Mechanical Calibration Kit: OSLT, DC - 4.5 GHz, 3.5 mm SMA-Male
                     F603ME
                                              connector
                                              Mechanical Calibration Kit: Open (M), Short (M), Match (M,50), Through (F-F),
                     F603FE
                                              4.5 GHz, SMA-type
                                              Mechanical Calibration Kit: OSLT, DC - 9 GHz, 3.5 mm SMA-Male
                     F604MS
                                              connector
                                              Mechanical Calibration Kit: OSLT, DC - 9 GHz, 3.5 mm SMA-Female
                     F604FS
                                              connector
                                              Mechanical Calibration Kit: OSLT, DC - 9 GHz, 3.5 mm-Male and Female
                     F604TS
                                              connector
                                              Mechanical Calibration Kit: OSLT, DC - 27 GHz, 3.5 mm-Male and Female
                     F604TY
                                              connector
www.siglent.com 24
Type              Model      Picture   Specifications
                  Y504MS               Integrated Mechanical Calibration Kit: OSLT, DC - 9 GHz, N-Male
VNA Calibration
Kit
                  Y504FS               Integrated Mechanical Calibration Kit: OSLT, DC - 9 GHz, N-Female
                                       Increase the voltage and current output capabilities to generators like the
                                       SIGLENT SDG family.
                                       Typical Input Impedance: 15 kΩ
                                       Input:
                                       +/- 6.5 V Vpp (Gain: X1)
                                       +/- 1.3 V (Gain: X10)
Amplifier         SPA1010
                                       Gain: Switched 10 V/1 V and 10 V/10 V
                                       Output Voltage: 25.4 Vpp
                                       Output Current: 1.12 A
                                       Slew Rate: ≥ 90 V/μs
                                       Overshoot: ≤ 4%
                                       Compatible with all SIGLENT SDG series generators
Synchronous
                  SYN64                64 synchronous module
Module
                  ANT-GPS1             GPS antenna, SMA(M), 100 cm
                                       Directional Antenna Suit, N type,
                                       ANT-DA11 antenna (10 MHz~200 MHz),
                  ANT-DA1              ANT-DA12 antenna (200 MHz~500 MHz),
                                       ANT-DA13 antenna (500 MHz~8 GHz),
                                       Amplifier handle 12dB@1GHz(typ.)
                                       Contains amplifier handle and 10 MHz ~ 200 MHz antenna. Antenna gain
Antenna           ANT-DA11             10 dB (typical value); SWR <1:1.9 (typical value); 50 Ω/N type, female;
                                       polarization direction horizontal and vertical
                                       Contains amplifier handle and 200 MHz ~ 500 MHz antenna. Antenna gain
                  ANT-DA12             10 dB (typical value); SWR <1:1.9 (typical value); 50 Ω/N type, female;
                                       polarization direction horizontal and vertical
                                       Contains amplifier handle and 500 MHz ~ 8 GHz antenna. Antenna gain 10 dB
                  ANT-DA13             (typical value); SWR <1:1.9 (typical value); 50 Ω/N type, female; polarization
                                       direction horizontal and vertical
                                       Board integrated with RF components like amplier, mixer, filter for vector
RF Test board     SNA-TB01
                                       network analyzer demonstration
                                                                                                    www.siglent.com 25
 Type                Model       Picture   Specifications
                     ADP-18                Adjustable differential TDR probe DC~18 GHz
                     ADP-26                Adjustable differential TDR probe DC~26.5 GHz
 TDR Probe
                     ASP-18                Adjustable single-end TDR probe DC~18 GHz
                     ASP-26                Adjustable single-end TDR probe DC~26.5 GHz
                     SSM5122A              2 input ports, 12 output ports, 3.5 mm female, 9 kHz~9 GHz
                     SSM5124A              2 input ports, 24 output ports, 3.5 mm female, 9 kHz~9 GHz
                     SSM5142A              4 input ports, 12 output ports, 3.5 mm female, 9 kHz~9 GHz
 Switch Matrix
                     SSM5144A              4 input ports, 24 output ports, 3.5 mm female, 9 kHz~9 GHz
                     SSM5321A              2 input ports, 6 output ports, 3.5 mm female, 100 kHz~26.5 GHz
                     SSM5342A              4 input ports, 12 output ports, 3.5 mm female, 100 kHz~26.5 GHz
 SSA3000X                                  Utility Kit for SSA3000X Series: N (M) -SMA (M) cable, N (M) -N (M) cable, N (M)
                     UKitSSA3X
 Utility Kit                               -BNC (F) adaptor (2 pcs), N (M) -SMA (F) adaptor (2 pcs), 10 dB attenuator;
 Rechargeable
                     10V8_BAT              10.8V, 74 Wh
 lithium battery
 AC-DC adapter       12V_AP_4A             12V, 4A
 Reflection                                RB (1 MHz~2.5 GHz), N (M) -N (M) adaptor (2 pcs), for SSA3000X,
                     RB3X25
 Bridge                                    SSA3000X Plus series
                                           A comprehensive PC-based software for general and standards-based signals
 PC Software         SigIQPro
                                           creation, supporting Bluetooth, IoT, Custom OFDM, etc.
 Noise Source
                     NSD28                 Noise source driver, connect spectrum analyzer to noise source
 Driver
www.siglent.com 26
Type              Model      Picture   Specifications
                  SEM5002A             2 ports, 9 kHz~4.5 GHz, SMA female
                  SEM5012A             2 ports, 9 kHz~9 GHz, SMA female
                  SEM5022A             2 ports, 100 kHz~13.5 GHz, 3.5 mm female
                  SEM5032A             2 ports, 100 kHz~26.5 GHz, 3.5 mm female
VNA Calibration
Kit
                  SEM5004A             4 ports, 9 kHz~4.5 GHz, SMA female
                  SEM5014A             4 ports, 9 kHz~9 GHz, SMA female
                  SEM5024A             4 ports, 100 kHz~13.5 GHz, 3.5 mm female
                  SEM5034A             4 ports, 100 kHz~26.5 GHz, 3.5 mm female
                  SSU5181A             DC~18 GHz, including one SPDT mechanical switch, SMA female
                  SSU5182A             DC~18 GHz, including two SPDT mechanical switchs, SMA female
                  SSU5183A             DC~18 GHz, including three SPDT mechanical switchs, SMA female
                  SSU5184A             DC~18 GHz, including four SPDT mechanical switchs, SMA female
                  SSU5261A             DC~26.5 GHz, including one SPDT mechanical switch, SMA female
                  SSU5262A             DC~26.5 GHz, including two SPDT mechanical switchs, SMA female
                  SSU5263A             DC~26.5 GHz, including three SPDT mechanical switchs, SMA female
Mechanical
Switch
                  SSU5264A             DC~26.5 GHz, including four SPDT mechanical switchs, SMA female
                  SSU5265A             DC~26.5 GHz, including one SP6T mechanical switch, SMA female
                  SSU5266A             DC~26.5 GHz, including two SP6T mechanical switchs, SMA female
                  SSU5501A             DC~50 GHz, including one SPDT mechanical switch, 2.4 mm female
                  SSU5502A             DC~50 GHz, including two SPDT mechanical switchs, 2.4 mm female
                  SSU5503A             DC~50 GHz, including three SPDT mechanical switchs, 2.4 mm female
                  SSU5504A             DC~50 GHz, including four SPDT mechanical switchs, 2.4 mm female
                                                                                               www.siglent.com 27