Jaiprakash Associates Ltd,

(Cement Division)
MASTER LIST OF LIGHTING ARRANGEMENT FOR CPP-1
SN AREA / LOCATION TYPE OF LIGHT QUANTITY
& TAG NO INSTALLED
1 TG Entrance Tube Light(40 W)
(TL-1 to TL-30)
HPMV(125/150 W)
(HPM-1 to HPM-77)
2 TG Building HPSV(70/150 W)
(HPS-1 to HPS-17)
Tube Light(40 W)
3 CCR / Office / (TL-31 to TL-70)
Conf.Room CFL(11 W)
(CFL-1 to CFL-4)
4 Indoor Store Tube Light(40 W)
(TL-71 to TL-76)
5 Boiler (up to ESP HPSV(70/150 W)
& ID Fan) (HPS-18 to HPS-160)
6 ACC HPSV(70/150 W)
(HPS-161 to HPS-205)
HPMV(125/150 W)
(HPM-78 to HPM-103)
7 DM Plant HPSV(70/150 W)
(HPS-206 to HPS-222)
Flame Proof(200 W)
(FP-1 to FP-4)
8 CHP (coal yard / Pri / HPSV(70/150 W)
Sec. Crasher (HPS-223 to HPS-368)
9 Ash Handling Plant HPSV(70/150 W)
(HPS-369 to HPS-385)
HPSV(70 W)
10 Road Side (HPS-386 to HPS-396 )

ABRIVIATION :
TL Tube Light
CFL Compact Flourasent Lamp
HPMV High Pressure Mercury Vapor Lamp
HPSV High Pressure Sodium Vapor Lamp
Jaiprakash Associates Ltd,
(Cement Division)
MASTER LIST OF LIGHTING ARRANGEMENT FOR CPP-3

SN AREA / LOCATION TYPE OF LIGHT


& TAG NO
1 TG Hall HPMV (125/400W)
(HPM-1 to HPM-22)
CFL(11 W)
(CFL-1 to CFL-3)
TG Building HPMV(125/150 W)
1) 4.5 mtr (HPM-22 to HPM-27)
2 2) 4.5 mtr cable celler HPSV(70/150 W)
3) "0" mtr (HPS-1 to HPS-57)
TG Building Tube Light(40 W)
3 CCR / GM.Office /VP. Office (TL-1 to TL-30)
Conf.Room/training hall/Eng. Office

TG Building Tube Light(40 W)


4 H.T room / I.O room / battery room (TL-31 to TL-71)
GRP/GCP/IO Sever room/stair case

TG Building out door HPSV(70/150W)


5 ACC/ CST/2.5MVA trafo (HPS-58 to HPS-111)
31.5 MVA/ MCT

5 Boiler 1&2 (up to ESP HPSV(70/150 W)


& ID Fan) (HPS-112 to HPS-306)
HPMV(125/150 W)
(HPM-78 to HPM-103)
7 DM Plant HPSV(70/150 W)
(HPS-206 to HPS-222)
Flame Proof(200 W)
(FP-1 to FP-4)
8 CHP HPSV(70/150 W)
Coal silo/Crusher house /"0" mtr (HPS-307 to HPS-412)
dump hopper/ belt conveyers/Coal yard HPSV(400W)
(HPS-223 to HPS-368)
9 Ash Handling Plant HPSV(70/150 W)
(HPS-369 to HPS-385)
HPSV(70 W)
10 Road Side (HPS-386 to HPS-396 )

ABRIVIATION :
TL Tube Light
CFL Compact Flourasent Lamp
HPMV High Pressure Mercury Vapor Lamp
HPSV High Pressure Sodium Vapor Lamp
QUANTITY
INSTALLED
Jaiprakash Associates Ltd,
(Cement Devision)

CHECK LIST OF LIGHTING ARRANGEMENT IN CPP-1

SN TAG NO PHYSICAL GLASS CABLE & FIXING SCREW


OF LIGHT CONDITION CONDITION CONNECTION CONDITION
1 CPP1/TL-1
2 TL-2
3 TL-3
4 TL-4
5 TL-5
6 TL-6
7 TL-7
8 TL-8
9 TL-9
10 TL-10
11 TL-11
12 TL-12
13 TL-13
14 TL-14
15 TL-15
16 TL-16
17 TL-17
18 TL-18
19 TL-19
20 TL-20
21 TL-21
22 TL-22
23 TL-23
24 TL-24
25 TL-25
26 TL-26
27 TL-27
28 TL-28
29 TL-29
30 TL-30
Jaiprakash Associates Ltd,
(Cement Devision)

CHECK LIST OF LIGHTING ARRANGEMENT IN CPP-1

SN TAG NO PHYSICAL GLASS CABLE & FIXING SCREW


OF LIGHT CONDITION CONDITION CONNECTION CONDITION
31 CPP1/HPS-1
32 HPS-2
33 HPS-3
34 HPS-4
35 HPS-5
36 HPS-6
37 HPS-7
38 HPS-8
39 HPS-9
40 HPS-10
41 HPS-11
42 HPS-12
43 HPS-13
44 HPS-14
45 HPS-15
46 HPS-16
47 HPS-17
48 CPP1/HPM-1
49 HPM-2
50 HPM-3
51 HPM-4
52 HPM-5
53 HPM-6
54 HPM-7
55 HPM-8
56 HPM-9
57 HPM-10
58 HPM-11
59 HPM-12
60 HPM-13
Jaiprakash Associates Ltd,
(Cement Devision)

SN TAG NO PHYSICAL GLASS CABLE & FIXING SCREW


OF LIGHT CONDITION CONDITION CONNECTION CONDITION
ates Ltd,
AREA : TG ENTRANCE

GLOW CHECKED BY
TEST NAME SIGN & DATE
ates Ltd,
AREA : TG BUILDING

GLOW CHECKED BY
TEST NAME SIGN & DATE
AREA : TG BUILDING

GLOW CHECKED BY
TEST NAME SIGN & DATE
Jaiprakash Associates Ltd,
(Cement Devision)
AREA : TG ENTRANCE
CHECK LIST OF LIGHTING ARRANGEMENT IN CPP-3

SN TAG NO PHYSICAL GLASS CABLE & FIXING SCREW GLOW CHECKED BY


OF LIGHT CONDITION CONDITION CONNECTION CONDITION TEST NAME SIGN & DATE
1 CPP1/TL-1
2 TL-2
3 TL-3
4 TL-4
5 TL-5
6 TL-6
7 TL-7
8 TL-8
9 TL-9
10 TL-10
11 TL-11
12 TL-12
13 TL-13
14 TL-14
15 TL-15
16 TL-16
17 TL-17
18 TL-18
19 TL-19
20 TL-20
21 TL-21
22 TL-22
23 TL-23
24 TL-24
25 TL-25
26 TL-26
27 TL-27
28 TL-28
29 TL-29
30 TL-30
Jaiprakash Associates Ltd,
(Cement Devision)
AREA : TG BUILDING
CHECK LIST OF LIGHTING ARRANGEMENT IN CPP-3

SN TAG NO PHYSICAL GLASS CABLE & FIXING SCREW GLOW CHECKED BY


OF LIGHT CONDITION CONDITION CONNECTION CONDITION TEST NAME SIGN & DATE
31 CPP3HPS-1
32 HPS-2
33 HPS-3
34 HPS-4
35 HPS-5
36 HPS-6
37 HPS-7
38 HPS-8
39 HPS-9
40 HPS-10
41 HPS-11
42 HPS-12
43 HPS-13
44 HPS-14
45 HPS-15
46 HPS-16
47 HPS-17
48 CPP3/HPM-1
49 HPM-2
50 HPM-3
51 HPM-4
52 HPM-5
53 HPM-6
54 HPM-7
55 HPM-8
56 HPM-9
57 HPM-10
58 HPM-11
59 HPM-12
60 HPM-13
Jaiprakash Associates Ltd,
(Cement Devision)
AREA : TG BUILDING

SN TAG NO PHYSICAL GLASS CABLE & FIXING SCREW GLOW CHECKED BY


OF LIGHT CONDITION CONDITION CONNECTION CONDITION TEST NAME SIGN & DATE

You might also like