A Ty c o I n t e r n a t i o n a l C o m p a n y
apS
Advanced Power System
Features That Make a Difference:
• Provides uninterrupted power backup for
iSTAR controllers and apC/8X
• Cabinet LEDs indicate battery voltage and
AC fault
• Low battery warning apS Advanced Power System provides Two relay outputs are provided on
uninterrupted power for iSTAR intelligent apS for connection to inputs on iSTAR
• AC failure supervision
access controllers and apC/8X alarm or apC/8X. One is connected to the
• Single or dual battery configurations monitoring panels. The combination of apS power fail input and indicates loss of
with iSTAR controllers or apC/8X panels AC power to apS. A second output
• Dedicated interface with main power input of serves as the basic building block for any is connected to the low battery input
iSTAR and apC/8X
C•CURE Security Management System. and indicates low battery voltage and
• Up to ten hours backup time with dual impending loss of backup power.
batteries apS connects directly to the main power
input replacing the standard power LED indicators located on the cabinet
• Cabinet width matches iSTAR and apC/8X
cabinet and uses the same key supply provided with iSTAR or apC/8X. door of apS display AC loss and
When apS senses an AC power failure, the relative battery voltage level to
• Reverse polarity protection it immediately notifies the host while approximate the state of battery charge.
continuing to supply the power required to
• Overcurrent protection
operate the panel and connected readers.
• Thermal protection
• UL 603 and UL 294 compliant
www.swhouse.com
A Ty c o I n t e r n a t i o n a l C o m p a n y
Specifications
Input Current Draw at 12 VDC1
Voltage . . . . . . . . . . . . . . . . . . . . . 120 VAC, 60 Hz Panels and Boards
Current . . . . . . . . . . . . . . . . . . . . . 2.5 amps AC maximum iSTAR GCM Boards . . . . . . . . . . . 290 mA
iSTAR ACM Boards . . . . . . . . . . . 180 mA
Output RM-4 Board . . . . . . . . . . . . . . . . . 75 mA
DC System RM-4E Board . . . . . . . . . . . . . . . . 280 mA without LCD
Voltage . . . . . . . . . . . . . . . . . . . . . 13.8 VDC iSTAR Relay Board . . . . . . . . . . . . 35 mA
Current . . . . . . . . . . . . . . . . . . . . . 3.75 ADC I8 Input Module . . . . . . . . . . . . . . 150 mA
Protection . . . . . . . . . . . . . . . . . . . Self-resetting PTC rated at 3.75 ADC R8 Output Module . . . . . . . . . . . . 150 mA (no active relays – add 17 mA
per active relay)
Battery apC/L . . . . . . . . . . . . . . . . . . . . . . 120 mA
Voltage . . . . . . . . . . . . . . . . . . . . . 13.8 VDC apC/8X . . . . . . . . . . . . . . . . . . . . . 120 mA
Current . . . . . . . . . . . . . . . . . . . . . 4.5 ADC maximum Star Coupler . . . . . . . . . . . . . . . . . 80 mA (no active relays – add 17 mA
Protection . . . . . . . . . . . . . . . . . . . Fused at 10 ADC fault outputs per active relay)
Mini Star Coupler . . . . . . . . . . . . . 40 mA
AC Fault WPSC Lower . . . . . . . . . . . . . . . . 60 mA
Output . . . . . . . . . . . . . . . . . . . . . Form C dry contact WPSC Upper . . . . . . . . . . . . . . . . 70 mA
Activation . . . . . . . . . . . . . . . . . . . AC power failure, blown AC fuse
Readers
Low Battery Software House Readers . . . . . . . 125 mA
Output . . . . . . . . . . . . . . . . . . . . . Form C dry contact Indala FlexPass Readers . . . . . . . 65 mA
Activation . . . . . . . . . . . . . . . . . . . Below 10.3 VDC Indala FlexPass Midrange . . . . . . . 120 mA
Sensor Eng WR1, WR2 . . . . . . . . 30 mA
Batteries HID MiniProx . . . . . . . . . . . . . . . . 60 mA
Single Rating . . . . . . . . . . . . . . . . 12 V/17 Ah HID Thinline II . . . . . . . . . . . . . . . . 20 mA (avg); 115 mA (peak)
Dual Rating . . . . . . . . . . . . . . . . . . 12 V/34 Ah HID ProxPro . . . . . . . . . . . . . . . . . 100 mA
Battery Backup Time . . . . . . . . . . Five hours at full load using one HID MaxiProx . . . . . . . . . . . . . . . . 200 mA
17 Ah SLA battery; ten hours at full load Barantec Readers . . . . . . . . . . . . .150 mA
using two 17 Ah SLA batteries ProxPoint Plus . . . . . . . . . . . . . . . 30 mA (avg); 75 mA (peak)
Battery Recharge Time . . . . . . . . . 12 hours HID iCLASS Readers . . . . . . . . . . 55 mA (avg); 121 mA (peak)
RM with Mag Stripe . . . . . . . . . . . 80 mA
Physical RM with Mag Stripe with LCD . . . 180 mA
Dimensions (H x W x D) . . . . . . . . 41.28 x 36.83 x 10.16 cm; RM with Indala Proximity . . . . . . . 80 mA
(16.25 x 14.5 x 4.0 in) RM with Indala Proximity
Weight without Battery . . . . . . . . . 8.8 kg (19.5 lbs) with LCD . . . . . . . . . . . . . . . . . . . 180 mA
Battery Weight (single) . . . . . . . . . 6.1 kg (13.5 lbs) RM with HID Proximity . . . . . . . . . 135 mA (avg); 250 mA (peak)
Housing . . . . . . . . . . . . . . . . . . . . 16 gauge carbon steel RM with HID Proximity
Operating Temperature . . . . . . . . . 0° to 50°C (32° to 122°F) with LCD . . . . . . . . . . . . . . . . . . . 235 mA (avg); 350 mA (peak)
Heat Dissipation . . . . . . . . . . . . . . 597 BTU/hr RM with HID
Proximity Mullion . . . . . . . . . . . . . 135 mA (avg); 250 mA (peak)
Regulatory RM1-W with Wiegand . . . . . . . . . 80 mA
Agency Certifications . . . . . . . . . . UL 603, UL 294, RoHS, FCC RM with HID iCLASS . . . . . . . . . . 160 mA
RM with HID iCLASS and LCD . . . 225 mA
RM with Software House
Multi-Technology . . . . . . . . . . . . . 170 mA (avg); 220 mA (peak)
RM with Software House
apS Installation Diagram Multi-Technology and LCD . . . . . . 270 mA (avg); 320 mA (peak)
ARM-1 Relay Module . . . . . . . . . . 17 mA (relay active)
MRM . . . . . . . . . . . . . . . . . . . . . . 140 mA
Schlage Scramble Keypad . . . . . . 500 mA max
Wireless PIM . . . . . . . . . . . . . . . . 300 mA
Wireless Reader Interface (WR1) . 300 mA
T.Rex Request to Exit Detector . . . 50 mA
iSTAR Pro PCMCIA Cards
Diamond SupraMax Modem . . . . . 220 mA
SMC EZ Card 10/100 Ethernet . . 400 mA
Model Numbers
AS0063-00 . . . . . . . . . . . . . . . . . . apS with battery, 120 VAC
AS0063-01 . . . . . . . . . . . . . . . . . . apS without battery, 120 VAC
(1) These currents are estimates. Voltage tolerance on 12 VDC inputs is +/- 15%.
Related Products Approvals
C•CURE 9000 C•CURE 800/8000 iSTAR Pro
www.swhouse.com
The trademarks, logos, and service marks displayed on this document are registered in the United States [or other countries]. Any misuse of the trademarks is strictly prohibited and Tyco International Ltd. will aggressively
enforce its intellectual property rights to the fullest extent of the law, including pursuit of criminal prosecution wherever necessary. All trademarks not owned by Tyco International Ltd. are the property of their respective owners,
and are used with permission or allowed under applicable laws.
Product offerings and specifications are subject to change without notice. Actual products may vary from photos. Not all products include all features. Availability varies by region; contact your sales representative.
© 2012 Tyco International Ltd. and its respective companies. All rights reserved. SH0131-DS-201208-R04-A4-EN