100% found this document useful (1 vote)
280 views8 pages

MEK 9200 Brochure

Uploaded by

Loan Do
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
280 views8 pages

MEK 9200 Brochure

Uploaded by

Loan Do
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

This brochure may be revised or replaced by Nihon Kohden at any time without notice.

10309 CAT.No.70-0036
Automated Hematology Analyzer
MEK-9200
Automated Hematology Analyzer
MEK-9200

Feature and Functions

ƒ Reticulocyte measurement ƒ Up to 55 samples/h (CBC + DIFF + RET) ƒ Westgard multirule function in QC mode
ƒ DynaScatter Laser +HEM488 technology ƒ 31 reportable parameters ƒ Re-measurement function
ƒ DynaHelix Flow technology ƒ 8 research parameters ƒ Auto-validation function
ƒ Smart ColoRac Match system ƒ Continuous sample loading system (10 samples/rack) ƒ Simple operation using barcodes for
reagent management function and QC mode
ƒ Up to 90 samples/h (CBC + DIFF) ƒ STAT / manual sample analysis
ƒ HL7 protocol through LAN connection
Technologies aiming for good laborator y operation and better patient outcomes

Hematology Products Since 1972

Nihon Kohden started IVD business in 1972 and has been developing leading edge medical electronic equipment.
Celltac series have been distributed to more than 120 countries in the world.
We will continue fighting disease for better patient outcomes.

History of Celltac Series

1972 1980 1987 1993 2002 2016 2021

MEK-1100 MEK-3100 MEK-7108 MEK-8118 MEK-8222 MEK-9100 MEK-9200


Core Concept

Laboratory
Management Patient Care

Accurate
Results

Efficient
Testing Flow
Shorter
TAT

CelltacG+ is equipped with Nihon Kohden's unique technologies.

DynaScatter Laser +HEM488 technology contributes to accurate 5-part Diff results and reticulocyte results,

DynaHelix Flow generates good quality result, and auto-loader makes Turnaround-Time shorter in laboratory operation.

Other functions and the effectiveness also support better laboratory management with efficient testing-flow.

The interaction of these factors leads to better patient care.


Unique Technology
CelltacG+ newly integrated reticulocyte parameters identified through our unique technology, DynaScatter Laser +HEM488.

The new laser technology has 2 lasers inside and one of them is a blue laser with 488 nm wavelength.

It excites stained cells and identifies reticulocyte based on the fluorescent scattered light.

For Reticulocyte Measurment For CBC Measurement

DynaScatter Laser Technology was initially developped for 5-part Diff. with only one laser source. DynaHelix Flow Technology using sheath flow and swirling flow to
In CelltacG+, 488 nm blue laser was newly integrated into the technology for reticulocyte. accurately count blood cells.

1. Nucleic acid staining solution stains DNA and RNA. This unique technology reduces “re-entry” of blood cells going after
2. The stained cells are excited by the blue laser, and fluoresces are generated. the detection aperture because swirling flow pushes out cells to
3. Cell size is calculated from forward scattered light, drain path. It is very effective especially for low cell volume sample.
DNA information is calculated by green fluorescent light,
and RNA information is calculated by red fluorescent light.

Additionally, fluorescent density is important to identify amount of reticulocytes.


It is analyzed from RNP method* minimizing the influence of interfering substances for more
accurate reticulocyte measurement result.

FL650: RNA
Photo DynaHelix Flow
Detector

FS: Cell Size FL525: DNA


Photo
Detector
Photo
Detector
Laser (= 488 nm)
Swirling Flow
Sheath Flow Aperture

* Y. Nagai et al. “Determination of red cells, nucleic acid-containing cells and platelets (RNP Determination) by a crossover analysis of emission DNA/RNA light”
Int. Jnl. Lab. Hem. 2009; 31: 420–429
Efficient Workflow
These functions realize to improve TAT* for a prompt report on your laboratory.

J Re-measurement J Auto Validation


Automatic re-measurement function occurs The instrument has auto-validation function
when unexpected alarms of equipment are based on the criteria used in your facility.
detected.
(Not related to flagging alarms)

* TAT: Turnaround Time

Measurement Confirmation of results Validation

Pickup Inspected by standard


abnormal sample method, etc.

This function provides Fast and Easy operation to pick up of samples.


You may face some situations such as clinically abnormal sample,
measurement error samples, or samples which barcode label cannot
be read. When CelltacG+ detects such samples, the tube location with a
special mark is shown on a display. You can just simply pick the sample P: Contains positive items
E: Measurement error
up based on the information. B: Barcode cannot be scanned
Specifications
Physical Specifications Barcode Format: • RET%: 15.0% or less (RET%: 1.00% or more and RBC: 300 × 106/μL or more)
Acceptable formats with or without check digits: • RET: 15.0% or less (RET%: 1.00% or more and RBC: 300 × 106/μL or more)
Dimensions and Weight: Industrial 2 of 5, ITF, JAN/EAN/UPC, NW-7, CODE 93, CODE 128 • IRF: 30.0% or less (IRF: 20.0% or more and RET%: 1.00% or more and
Dimensions: 675 W × 589 D × 576 H (mm) ±10% (Main unit only, excluding Loading Capacity: RBC: 300 × 106/μL or more)
protruding parts) • Maximum 70 sample tubes • LFR: 30.0% or less (LFR: 20.0% or more and RET%: 1.00% or more and
Weight: 76 kg ±10% RBC: 300 × 106/μL or more)
Power Requirements: Repeatability and Linearity • MFR: 50.0% or less (MFR: 20.0% or more and RET%: 1.00% or more and
• Line voltage: AC 100 to 240 V ±10% AC, 50/60 Hz RBC: 300 × 106/μL or more)
Precision (Reproducibility)
• Power input: max 360 VA • HFR: 100.0% or less, or within ±2.0 HFR (RET%: 1.00% or more and RBC:
• WBC: 2.0% or less (WBC: 4.00 × 103/μL or more)
Sound Pressure Level: < 75 dB 300× 106/μL or more)
• RBC: 1.5% or less (RBC: 4.00 × 106/μL or more)
31 Reportable Parameters: (Specifications above applies to normal mode)
• HGB: 1.5% or less
WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, PCT, MPV, Linearity
• HCT: 1.5% or less
PDW, P-LCR, NE, NE%, LY, LY%, MO, MO%, EO, EO%, BA, BA%, P-LCC, RET, • WBC: within ±3.0% OR ±0.3 × 103/μL (WBC: 0.20 to 95.0 × 103/μL)
• MCV: 1.0% or less
RET%, IRF, LFR, MFR, HFR • RBC: within ±3.0% OR ±0.08 × 106/μL (RBC: 0.02 to 8.50 × 106/μL)
• PLT: 4.0% or less (PLT: 100 × 103/μL or more)
8 Research Parameters: Mentzer Index, RDWI, IG, IG%, Band, Band%, Seg, Seg% • HGB: within ±1.5% OR ±0.2 g/dL (HGB: 0.10 to 25.0 g/dL)
• NE%: 5.0% or less (NE%: 30.0% or more and WBC: 4.00 × 103/μL or more)
Throughput: • HCT: within ±3.0% OR ±1.0% (HCT: 10.0 to 70.0%)
• LY%: 5.0% or less (LY%: 15.0% or more and WBC: 4.00 × 103/μL or more)
• Up to 90 samples per hour (CBC + DIFF) • PLT: within ±10.0% OR ±20 × 103/μL (PLT: 10 to 1500 × 103/μL)
• MO%: 12.0% or less (MO%: 5.0% or more and WBC: 4.00 × 103/μL or
• Up to 55 samples per hour (CBC + DIFF + RET) • RET%: within ±20% or ± 0.30% (RET%) (RET%: 0.50 to 30.00%)
more)
Patient Memory Capacity: 50,000 patient with graphs • RET: within ±20% or ± 1.50 × 104/μL (RET: 0.50 to 72.0 × 104/μL)
• EO%: 20.0% or less or within ±1.0 EO% (WBC: 4.00 × 103/μL or more)
Sample Volume: (Specifications above applies to normal mode)
• BA%: 30.0% or less or within ±1.0 BA% (WBC: 4.00 × 103/μL or more)
• CBC: 32 μL
• CBC + DIFF: 47 μL
• NE: 8.0% or less (NE: 1.20 × 103/μL or more) Operating Environment
• LY: 8.0% or less (LY: 0.60 × 103/μL or more)
• CBC + RET: 47 μL
• MO: 20.0% or less (MO: 0.20 × 103/μL or more) • Temperature: 15 to 30˚C (59 to 86˚F)
• CBC + DIFF + RET: 47 μL
• EO: 25.0% or less or within ±0.10 × 103/μL (WBC: 4.00 × 103/μL or more) • Humidity: 30 to 85% (non-condensing)
• Pre-dilution mode: 20 μL
• BA: 30.0% or less or within ±0.10 × 103/μL (WBC: 4.00 × 103/μL or more) • Atmospheric pressure: 700 to 1060 hPa (altitude: < 3000 m)

Consumables and Accessories


Common Consumables with New Items
MEK-9100
• Diluent: Isotonac 3 or Isotonac 4,
MEK-640 or MEK-641
• Hemolysing reagent:
Hemolynac 310, MK-310W
Hemolynac 510, MK-510W
• Detergent: Cleanac 710, MK-710W
Cleanac 810, MK-810W
Staining reagent for reticulate: Hematology control for reticulocyte: (Local purchase) SPHERO TM Rainbow (Option) Adapters for blood collection tube:
• Hematology control for 5 part DIFF: Reticulonac, MK-110W MK-RE1, MK-RE2, MK-RE3 Fluorescent Particles (RFP-30-5) YZ-0081B1 (BD, KABE, SARSTEDT for STAT,
MEK-5DL/5DN/5DH and SARSTEDT kit for auto loader)
SPHERO is a trademark of Spherotech, Inc.

You might also like