TJ21PE5S

The document provides specifications for a 21 kVA diesel generator set, including details on its engine, alternator, and power output ratings. It highlights standby and prime power definitions, fuel consumption rates, and technical standards compliance. The generator is manufactured by Teksan and features a Perkins engine and Stamford alternator, with various operational and physical characteristics outlined.

Uploaded by

JmlPinkFloyd
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
39 views1 page

TJ21PE5S

The document provides specifications for a 21 kVA diesel generator set, including details on its engine, alternator, and power output ratings. It highlights standby and prime power definitions, fuel consumption rates, and technical standards compliance. The generator is manufactured by Teksan and features a Perkins engine and Stamford alternator, with various operational and physical characteristics outlined.

Uploaded by

JmlPinkFloyd
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

TJ21PE5S

Diesel Generator Sets / 50 Hz

Power Output Ratings 50 Hz / 400 V

kVA 21
Standby Power (ESP)
kW 17

kVA 19
Prime Power (PRP)
kW 15

Engine

Manufacturer PERKINS
Model 404A ­22G
No of Cylinder / Configuration 4 ­ INLINE
Displacement lt 2,216
Bore / Stroke mm 84 / 100
Compression Ratio 23,3:1
Aspiration Naturally Aspirated
Governor Type MECHANIC
Cooling System WATER
Coolant Capacity lt 7 Standby Power
Lubrication Oil Capacity lt 4,9
Standby power is defined as the maximum power
available during a variable electrical power
Electrical System VDC 12 sequence, under the stated operating conditions, for
Speed / Frequency 1500 rpm / 50 Hz which a generating set is capable of delivering in the
event of a utility power outage or under test
Engine Gross Power kWm 20,6 conditions for up to 500 hours of operation per year
110 % 6,2 under average of 70% load. Overloading is not
permissible.
100 % 5,4
Fuel Consumption lt/h
75 % 4 Prime Power
50 % 2,9 Prime power is defined as being the maximum power
which a generating set is capable of delivering
Exhaust Outlet Temperature °C 505 continuously whilst supplying a variable electrical
Exhaust Gas Flow m³/min 3,94 load. Average load should be 70%. The generator can
be overloaded 10% for 1 hour per 12 hours.
Combustion Air Flow m³/min 1,45
Cooling Air Flow m³/min 29,4

Alternator

Manufacturer STAMFORD
Model PI144D
No of Phase 3
Power Factor 0,8
No of Bearing SINGLE
No of Poles 4
No of Leads 12
Voltage Regulation ( Steady State) ± %1
Insulation Class H
Degree of Protection IP 23
Excitation System AVR (Automatic Voltage Regulator), Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %2
Frequency Hz 50
Voltage Output VAC 230 / 400
Rated Power (Standby) kVA 22
Efficiency % 84,4

Noise dB(A)
W x L x H (mm) Weight (kg) lt Fuel Tank (lt)
@ 1m
Canopied 700 x 1750 x 1200 621 75 70
Open Skid 710 x 1400 x 1050 456 75 TBA

­ Technical information and values are according to ISO8528, ISO3046,NEMA MG­1.22, IEC 60034­1, BS 4999­5000, VDE 0530 standards.
­ Producing with ISO9001, ISO14001, OHSAS18001, TSE, CE standards.
­ All information given in this leaflet is intended for general purposes only. Due to a policy continuous improvement Teksan reserves the right to amend
details and specifications without notice and all information given is subject to the Teksan's current condition of sales.

TBA: To Be Ask TBD: To Be Determined NA: Not Avaliable N/A: Not Applicable TTD21PE5S0414­EN