This document provides specifications for an 89kVA/71kW diesel generator set that operates at 50Hz/400V including: 1) Power output ratings for standby and prime power modes and definitions of each. 2) Engine details like the Perkins 1104A-44TG2 model with 4 cylinders, 4.4L displacement, and 80.7kWm gross power. 3) Alternator details like the Crompton Greaves G1R200MD 3-phase model with 90.75kVA standby power rating, 90.1% efficiency, and 50Hz/230/400V output. 4) Dimensions and weights for the canopied and open sk

Uploaded by

blago956
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
111 views1 page

TJ89PE5C

This document provides specifications for an 89kVA/71kW diesel generator set that operates at 50Hz/400V including: 1) Power output ratings for standby and prime power modes and definitions of each. 2) Engine details like the Perkins 1104A-44TG2 model with 4 cylinders, 4.4L displacement, and 80.7kWm gross power. 3) Alternator details like the Crompton Greaves G1R200MD 3-phase model with 90.75kVA standby power rating, 90.1% efficiency, and 50Hz/230/400V output. 4) Dimensions and weights for the canopied and open sk

Uploaded by

blago956
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

TJ89PE5C

DieselGeneratorSets/50Hz


50Hz/400V

PowerOutputRatings
StandbyPower(ESP)

PrimePower(PRP)

kVA

kW
kVA
kW

89
71
81
65

StandbyPower(ESP)
Manufacturer
Model
NoofCylinder/Configuration
Displacement
Bore/Stroke
CompressionRatio
Aspiration
GovernorType
CoolingSystem
CoolantCapacity
LubricationOilCapacity
ElectricalSystem
Speed /Frequency
EngineGrossPower

FuelConsumption

lt/h

ExhaustOutletTemperature
ExhaustGasFlow

CombustionAirFlow
CoolingAirFlow

lt
mm

lt
lt
VDC

kWm
110%
100%
75%
50%
C
m/min
m/min
m/min

PERKINS
1104A 44TG2
4INLINE
4,4
105 /127
17,25:1
Turbocharged
MECHANIC
WATER
13

StandbyPower
Standbypowerisdefinedasthemaximumpower
availableduringavariableelectricalpower
sequence,underthestatedoperatingconditions,for
whichageneratingsetiscapableofdeliveringinthe
eventofautilitypoweroutageorundertest
conditionsforupto500hoursofoperationperyear
underaverageof70%load.Overloadingisnot
permissible.

8
12
1500rpm/50Hz
80,7
20,5
18,7
14

PrimePower
Primepowerisdefinedasbeingthemaximumpower
whichageneratingsetiscapableofdelivering
continuouslywhilstsupplyingavariableelectrical
load.Averageloadshouldbe70%.Thegeneratorcan
beoverloaded10%for1hourper12hours.

9,7
580
13,3
5,14

89

Alternator
Manufacturer
Model
NoofPhase
PowerFactor
NoofBearing
NoofPoles
NoofLeads
VoltageRegulation(SteadyState)
InsulationClass
DegreeofProtection
ExcitationSystem
ConnectionType
TotalHarmonicContent(NoLoad)
Frequency
VoltageOutput
RatedPower (Standby)
Efficiency

Hz
VAC
kVA
%

CROMPTONGREAVES

G1R200MD
3
0,8
SINGLE
4
12
%1
H
IP23
AVR(AutomaticVoltageRegulator),Brushless
STAR

<%2,5
50
230/400
90,75
90,1

WxLxH(mm)

Canopied
OpenSkid

950 x2650 x1450


950 x2000 x1230

Weight(kg)

1247
952

lt

FuelTank(lt)

NoisedB(A)
@1m

160

76

160

TBA

TechnicalinformationandvaluesareaccordingtoISO8528,ISO3046,NEMAMG1.22,IEC600341,BS49995000,VDE0530standards.
ProducingwithISO9001,ISO14001,OHSAS18001,TSE,CEstandards.
Allinformationgiveninthisleafletisintendedforgeneralpurposesonly.DuetoapolicycontinuousimprovementTeksanreservestherighttoamend
detailsandspecificationswithoutnoticeandallinformationgivenissubjecttotheTeksan'scurrentconditionofsales.
TBA:ToBeAsk

TBD:ToBeDetermined

NA:NotAvaliable

N/A:NotApplicable

www.teksangenerator.com

TTD89PE5C0414EN

11.06.2014 15:43

You might also like