Accessories
Transmitters to combine with pressure gauges
Model 891.34
Model 892.34 Ex-Version
                                                                                                   WIKA Data Sheet AC 08.02
 Applications
 For installation in pressure gauges, measuring ranges from
  0 … 2.5 mbar to 0 … 1000 bar
 Transmitter with magnetic field-dependent sensor and
  amplifier
 Industry standard signals are available 4 ... 20 mA resp.
  0 ... 20 mA
 With mechanical analogue indication
 Special Features
 Basic pressure gauge with mechanical analogue indica-
  tion, needing no external power
 Transmitter without effect on mechanical analogue
  indication
 Combination of transmitters and alarm contacts possible
 Liquid filling case possible
 Optional accessories in accordance with details given in       Bourdon tube pressure gauge, Model 632.50
  the respective basic pressure gauge data sheets                with transmitter Model 891.34
Description
Service intended
WIKA pressure gauges with integrated transmitter Model           The standard 4 ... 20 mA current signals in 2-wire system or
89X.34 combine the advantages of on-site mechanical              0 ... 20 mA in 3-wire system are generated by the integrated
indication with the demands for electrical signal transmis-      amplifier on the pressure gauge with transmitter, Model
sion for modern measured value registration in industry.         891.34.
Operating principle                                              The intrinsically safe version, Ex-class version Model
Spring-elastic measuring elements in bourdon tube,               892.34, has to be used in explosion hazardous areas.
diaphragm or capsule form are used as pressure pick-ups.         The EC-Type Examination Certificate of the DMT (Deutsche
The movement of the measuring element is used on the             Montan Technologie GmbH) for intrinsically safe instru-
mechanical side for movement deflection and converted            ments in ignition protection Class “Ex II 2G EEx ia IIC T6”
into an electrical output signal on the electrical side by a     and “I M2 EEx ia I” is provided for Model 892.34.
magnetic field-dependent sensor (Hall sensor).                   Due to the standard 4 ... 20 mA output signal these gauges
                                                                 can be used in all industries.
  WIKA Data Sheet AC 08.02 ∙ 05/2008                                                                             Page  of 4
Data Sheets showing similar devices:
Electrical Alarm Contacts; Models 8xx; see Data Sheet AC 08.01
 Specifications                                                   Model 891.34 and Model 892.34 (Ex-version)
 Power supply UB
  For non-Ex-class version                   DC V                10 < UB ≤ 30
  For Ex-class version                                           see section Ex-class protection
 Supply voltage effect                        % of FS/10 V        ≤ 0.1
 Permissible residual ripple                  % ss                ≤ 10
  Output signal                                                  for non-Ex-class version, Model 891.34:
                                                                  4 … 20 mA, 2-wire
                                                                  0 … 20 mA, 3-wire
                                                                  {0 ... 10 V, 3-wire}
  Permissible max. load RA                                       RA ≤ (UB - 10 V)/0.02 A with RA in Ohm and UB in Volt, however max. 600 Ω Ω
  Output signal for Ex                                           for Ex-class version, Model 892.34:
                                                                  4 … 20 mA, 2-wire
  Permissible max. load RA for Ex                                RA ≤ (UB - 12.5 V)/0.02 A with RA in Ohm and UB in Volt, however max. 600 Ω Ω
 Effect of load                               % FS                ≤ 0.1
 Response time                                ms                  approx. 50 (Model 736.51 approx. 1 s, optional 50 ms)
 Output signal adjustment
  Zero point, electrical                     % of span           ±5
  Span, electrical                           % of span           ±5
 Linearity by accuracy of local readout
  Class 1.6                                  % of span           ± 1.0 (limit point calibration)
  Class 1.0                                  % of span           ± 0.8 (limit point calibration)
 Hysteresis by accuracy of local readout:
  Class 1.6                                  % of span           ≤ 0.8
  Class 1.0                                  % of span           ≤ 0.5
 Permissible
  Medium temperature 1)                      °C                  -25 … +100
  Ambient temperature 1)                     °C                  -20 … +60
 Compensated temperature range                °C                  -25 … +60
 Temperature coefficient in compensated temperature range
  Average TK on zero point                   % of span/10 K      ≤ 0.3
  Average TK on span                         % of span/10 K      ≤ 0.3
 Ex-class protection                                              according to EC-Type Examination Certificate DMT 01 ATEX E 021 for Model 892.34
 Output signal                                                    4 … 20 mA, 2-wire
 Ex-certification                                                 Ex II 2G EEx ia IIC T6 and I M2 EEx ia I
 Conformity specifications
  Power supply                               DC V                12.5 … 28
  Short circuit rating                       mA                  100
  Rating                                     mW                  1000
  Internal capacitance                       nF                  Ci ≤ 24
  Internal inductance                        mH                  Li ≤ 0.2
  Medium temperature                         °C                  -20 … +60
  Ambient temperature                        °C                  -20 … +60
 CE-Conformity                                                    Interference emission and immunity per EN 61 326
 Wiring                                                           Terminal box (screw terminal up to 2,5 mm²)
 Wiring protection                                                Protected against reverse polarity and overvoltage
 Ingress protection                                               IP 65 per EN 60 529 / IEC 529
{ } Items in curved brackets { } are optional for additional price.
1) For maximum values of Ex-class versions: see Ex-class protection
 Page  of 4                                                                                                    WIKA Data Sheet AC 08.02 ∙ 05/2008
Dimensions in mm
                            only with filled version
                                                                                                                        1592513.01
                                                                       Equipotential bonding terminal
                                                                       only on Ex versions
Position of potentiometer
The potentiometers are accessible after unscrewing the screw plugs in the top of the casing.
                                                        SP Potentiometer for span
                                                        NP Potentiometer for zero point
                                                                                                                        1592483.01
Connection details
The terminals 1 and 5 are bridged internally in the terminal box providing two terminals for the 0 V / S- connection.
                 4 … 20 mA 2-wire system                                                                      0 … 20 mA 3-wire system
                                                                                                                                                    1416324.03
         0 V / S-                                                                                            0 V / S-
         UB+ / S+                                                                                            UB+
                Test-                                                                                              Test+
                Test+                                                                                        S+ / Test-
                                                                                                        mA
           mA                                                                                  Receiving instrument
                                                 Terminal box                                  e.g. indicator                        Terminal box
          Receiving instrument
          e.g. indicator
             Power supply                                                                        Power supply
Operating Instructions including further information about mounting and commissioning as well as operation and mainte-
nance is enclosed to each shipment of a pressure transmitter with local readout.
 WIKA Data Sheet AC 08.02 ∙ 05/2008                                                                                                      Page  of 4
Feasibility of installing transmitters into pressure gauges
The described transmitters will be built in the following
pressure gauges 1). Furthermore in most alarm contacts can
be combined with transmitters (see food notes for limita-
tions).
 Pressure gauge                                                           Transmitters                      Transmitters and alarm contacts
 Mo-          No-            Pressure                 Data sheet          Model                             Transmitter model
 del          minal          connection                                   891.34           892.34           891.34                           892.34
              size                                                                                          Alarm contact model (data sheet AC 08.01)
                                                                                                            821             831              831
 632.50 100                  bottom                   PM 06.03            x                x
 736.51 100/160 bottom                                PM 07.08            x                x                x 2)            x                    x
1)    Other feasibility of installing into pressure gauges on request.
2)    Inquire feasibility when intended for flammmable gases!
Measuring instruments with integrated tranmitter see “Mechatronical Pressure Measurement” with Models PGT.
Accessories
Power supply unit devices for pressure gauge with                                                  Ex-Galvanic Separator for pressure gauge with trans-
Transmitter Model 891.34 under non-Ex-operation                                                    mitter Model 892.34 under Ex-operation
For non-Ex-operation the following power supply unit                                               For Ex-operation the following ex-galvanic separator are
devices are available for DC-supply of transmitter Model                                           available for galvanical separation and transfer of power
891.34:                                                                                            supply for transmitter Model 892.34:
Model A-VA-1                                                                                       Model KFD2-STC4-Ex1
Power Supply Unit, line voltage AC 230 V, output voltage DC                                        Ex-Transmitter Supply Isolator, line voltage: DC 20 ... 32 V,
24 V, max. 70 mA                                                                                   output voltage: max. DC 25.4 V, max. 88.2 mA
Model KFA6-STR-1.24.500                                                                            Model SI815-52
Power Supply Unit, line voltage AC 90 ... 253 V, 48 ... 63 Hz,                                     Ex-Galvanic Separator with power supply transfer for 2-wire
output voltage DC 24 V, max. 500 mA                                                                system 4 ... 20 mA.
                                                                                                   The galvanic separator is usable with power supply or
                                                                                                   electronic indicating instrument with integrated power
                                                                                                   supply for transmitter. When calculating the permissi-
                                                                                                   ble max. load RA a voltage drop of 7.7 V at the galvanic
                                                                                                   separator has to be considered.
Ordering information
Pressure gauge model / Nominal size / Scale range / Size and location of connection / Model-no. of Transmitter / Output
signal required
Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing.
Modifications may take place and materials specified may be replaced by others without prior notice.
                                                                                                                                                                     9029281 05/2008 GB
     Page  of 4                                                                                                                WIKA Data Sheet AC 08.02 ∙ 05/2008
                                                                                                                       WIKA Alexander Wiegand GmbH & Co. KG
                                                                                                                       Alexander-Wiegand-Straße 30
                                                                                                                       63911 Klingenberg/Germany
                                                                                                                       Tel.   (+49) 9372/132-0
                                                                                                                       Fax    (+49) 9372/132-406
                                                                                                                       E-mail info@wika.de