Mechatronic
Pressure Measurement
Differential Pressure Transmitter
Model 891.34.2189
                                                                                                                                WIKA Data Sheet PV 17.18
 Applications
 Suitable for all gaseous and liquid media that will not
  obstruct the pressure system
 Heating, climatic, ventilating, dust removing technoclogy
 Technical building equipment, filter plants,
  drinking and service water treatment
 Monitoring and control of pumps in pressure boosting
  and fire exstinguishing plants
 Special Features
 Differential pressure measuring ranges from
  0 ... 160 mbar
 High working pressure (static pressure) up to 25 bar
 Overpressure safety either side up to 25 bar
 Solid case construction for protection against external
  mechanical effects                                                                        DELTA-trans with integrated 3½-digit LCD-display and
 Integrated pressure equalising valve (option)                                             compression fitting with ferrule (option)
Description
The differential pressure transmitters DELTA-trans are parti-                              As an option, the differential pressure transmitter DELTA-
cularly intended for the measurementof very low differential                               trans (in 2-wire design; 4 ... 20 mA) may be supplied with an
pressures with high demands on one-sided overload.                                         integrated 3½-digit LCD-display.
Standard output signals of 4 … 20 mA (2-wire system) or                                    Electrical connection is made by means of a cable box with
0 … 20 mA (3-wire system) can be provided from a non-                                      cable gland M20 x 1.5.
stabilised DC supply of 10 … 30 V.
Due to the solid and compact design of the instrument,
the operation requires almost no maintenance even under
arduous industrial service conditions.
 WIKA Data Sheet PV 17.18 ∙ 12/2009                                                                                                          Page 1 of 4
Data sheets showing similar devices:
DELTA-plus, Differential pressure gauges with integrated working pressure gauges; Model 702.01.100; see data sheet PM 07.15
DELTA-switch, Differential pressure switches; Model 851.02.100; see data sheet PV 27.17
DELTA-comb, Differential pressure gauges with alarm contacts, and micro switch; Model 702.02.100; see data sheet PV 27.16
Specifications                                        DELTA-trans Model 891.34.2189
Differential pressure range        bar                0 ... 0.16 to 0 ... 25
Max. working pressure (stat.)      bar                25
Overpressure safety                bar                Either side max. 25
Process connections                (wetted)           2x G ¼ female, lower mount (LM), in-line, axle base 26 mm
                                                      (option: other pressure connections male or female or
                                                      conpression fitting with ferrule for pipe Ø 6, 8 or 10 mm respectively)
Media chamber                      (wetted)           GD-AISi 12 (Cu) 3.2982, black lacquered
                                                      (option GD-AlSi 12 (Cu) HART-COAT-surface protection or stainless steel)
Press. element compress. spring    (wetted)           Stainless steel 1.4310 or FD SiCr EN 10270-2
Press. element separ. diaphragm    (wetted)           FPM/FKM fabric back stay (option: NBR)
Links                              (wetted)           Stainless steel 1.4305, FPM/FKM (option: NBR)
Sealings                           (wetted)           FPM/FKM (option: NBR)
Press. equalising valve (option)   (wetted)           Stainless steel and FPM/FKM
4-way valve manifold (option)      (wetted)           Cu-alloy or stainless steel, 1x pressure equalising valve, 2x gauge valve,
                                                      1x valve for purging or air bleeding
Power supply UB                    DC V               10 < UB ≤ 30 (option: LCD-display 14 < UB ≤ 30)
Permissible residual ripple        % of span / 10 V   ≤ 0.1
Supply voltage effect              % ss               ≤ 10
Output signal and                                     4 … 20 mA, 2-wire system RA ≤ (UB - 10 V) / 0.02 A with RA in Ohm and UB in Volt
permissible max. load RA                              0 … 20 mA, 3-wire system RA ≤ (UB - 10 V) / 0.02 A with RA in Ohm and UB in Volt
Effect of load                     % of span          ≤ 0.1
Response time                      s                  Approx. 1 (approx. 50 ms option)
Output signal adjustment
 Zero point, electrical           % of span          ±15
 Span, electrical                 % of span          ±30
Linearity                          % of span          2.5 (limit point calibration)
(including hysteresis)                                Option: 1.6 (limit point calibration)
Permissible
 Medium temperature               °C                 +80 max.
 Ambient temperature              °C                 -10 … +60 (option LCD-display 0 … +50)
Compensated temperat. range        °C                 -10 … +60 (option LCD-display 0 … +50)
Temperature coefficients in
compensated temperat. range
 average TK of zero point         % of span / 10 K   ≤ 0.4
 average TK of span               % of span / 10 K   ≤ 0.4
LCD-display (option)                                  Only with electrical output signal 4 ... 20 mA, 2-wire system
 Voltage load                     DC V               3.5
 Display                                             3½-digit, height 12.7 mm
 Ambient temperature              °C                 0 … +50
 Storage temperature              °C                 -10 … +80
Wiring                                                Terminal box ( screw terminals up to 2.5 mm2)
Wiring protection                                     Protected against reserve polarity and overvoltage
EMC (electromagnetic                                  Interference emission per EN 50 081 - 1 (March 93) and EN 50 081 - 2 (March 94),
compatibility)                                        Interference immunity per EN 50 082 - 2 (March 95)
Ingress protection                                    IP 54 per EN 60 529 / IEC 529 (option: IP 65)
Weight                             kg                 Approx. 1.3
Dimensions                         mm                 See drawings
Page  of 4                                                                                           WIKA Data Sheet PV 17.18 ∙ 12/2009
Approval German Lloyd (option)
 Additional or deviating specifications
 Pressure ranges                      bar               0 ... 0.25 to 0 ... 10
 Output signal                                          4 ... 20 mA, 2-wire or 0 ... 20 mA, 3-wire, current limit I < 32 mA
 Permissible ambient temperatur       °C                -10 ... +70
 EMC (electromagnetic                                   Interference emission per EN 50 081 - 1 (March 93) and EN 50 081 - 2 (March 94),
 compatibility)                                         Interference immunity per EN 50 082 - 2 (March 95)
 ESD                                  kV                ±8          contact discharge                                            IEC 1000-4-2
 Electromagnetic fields               V/m               10          80 % AM, 1 kHz, 0.01 ... 1000 MHz                            IEC 1000-4-3
 Burst                                kV                ±2          coupling clamp                                               IEC 1000-4-4
 Conducted HF-disturbance             V                 3           80 % AM, 1 kHz, 0.01 ... 1000 MHz                            IEC 1000-4-6
 Surge                                kV                ±0.5        symmetrically                                                IEC 1000-4-5
                                      kV                ±1          asymmetrically, Ri= 42 Ohm
                                      kV                ±1          symmetrically
                                      kV                ±2          asymmetrically, Ri= 42 Ohm, with surge protection only
                                                                    e.g. MM-DS/x-NFE(L), firm Dehn & Söhne, or equivalent
 Conducted NF-disturbance             Veff.             3           0.05 ... 10 kHz                                              IEC 945
 Vibration test Fc
 2 ... 25 Hz, ±1.6 mm                 %                 < 2.5      error                                                                                 IEC 68-2-6
 25 ... 100 Hz, 4 g                   %                 < 2.5      error
Design and operating principle                                                      Illustration of operating principle
The differential pressure transmitter consists mainly of a
mechanical measuring system (1) with elastic pressure
element (2), magnetic-field-dependent sensor (3) with signal
processing board (4) and case with the connecting parts for
the electronics.
A magnet (5) rigidly coupled to the pressure element influ-
ences the electromagnetic field of the HALL sensor. The
resulting signal is amplified to a standard output signal via
                                                                                                                                                                          2155079.01
the signal processing board.
For recalibration, zero and span can be adjusted by means
of easily accessable potentiometers (6).1)
                                                                                    1) Restriction: If an LCD display is integrated, it must be noted that the zero point and
                                                                                       span adjustment is to be used only for recalibration of the measuring range. Changes
Pressure entries identified,                                                           of the measuring range made by the user by means of the zero and span adjustment
                                                                                       will not be taken into account by the display. If zero / span adjustments are to be
j high pressure, i low pressure                                                        applied during use, we recommend a display 0 ... 100 %.
Position of the potentiometer                             Connection details
The potentiometers are accessible                         The terminal 1 and 5 are briged internally in the
after unscrewing the screw plugs                          terminal box providing two terminals for the
in the top of the casing.                                 0 V / S - connection.
                                                                4 ... 20 mA 2-wire system                             0 ... 20 mA 3-wire system
                                                                   0V/S-                                                        0V/S-
                                                                   UB+/ S +                                                            U B+
                                                                     Test -                                                           Test +
                                                                     Test +                                                       S + / Test -
                                                                                                                                    mA
                                                                                             Terminal box                         Receiving
                                                                      mA                                                          instrument                  Terminal
                                                                     Receiving instrument                                         (e.g. indicator)            box
                                           2158991.01
                                                                                                                                                                         1416324.03
                                                                     (e.g. indicator)
    SP Potentiometer for span
    NP Potentiometer for zero point
                                                                     Power supply                                                Power supply
WIKA Data Sheet PV 17.18 ∙ 12/2009                                                                                                                          Page 3 of 4
Dimensions in mm
Standard version                                                                                                   Option LCD-display
                                                                                                                                                              2156921.03
Option                                             Option Integrated                                Option
Panel mounting                                     pressure equalising valve                        4-way valve manifold
                                                                                                                      Pressure
                                                                                                                      equalising
                                                                                                                      valve
                                                                                                                                                        Valve for
                                                                                                                                                        purging
                                                                                                                                                        or air
                                                                                                                                                        bleeding
Panel cut-out
                                                                                                                           Gauge valve,               Gauge valve,
                                                                                                                           high pressure              low pressure
                                                                                                                           side j                     side i
                                      2157322.02
                                                                                       2261804.01
                                                                                                                                                              2261821.04
                    Panel
Ordering information
Model / Measuring range / Output signal / Process connection / Material of media chamber / Material of seperation
diaphragm and sealings / Options
Modifications may take place and materials specified may be replaced by others without prior notice.
Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing.
      Page 4 of 4                                                                                                             WIKA Data Sheet PV 17.18 ∙ 12/2009
                                                                                                                                                                           12/2009 GB
                                                                                                                    WIKA Alexander Wiegand SE & Co. KG
                                                                                                                    Alexander-Wiegand-Straße 30
                                                                                                                    63911 Klingenberg/Germany
                                                                                                                    Tel.   (+49) 9372/132-0
                                                                                                                    Fax    (+49) 9372/132-406
                                                                                                                    E-mail info@wika.de
                                                                                                                    www.wika.de