0% found this document useful (0 votes)
40 views2 pages

HRP 600 Spec

The HRP-600 series is a 600W single output power supply with a built-in active PFC function and high efficiency up to 89%. It offers multiple output voltage options ranging from 3.3V to 48V, with various protections including short circuit and over temperature. The power supply is designed for a wide range of operating conditions and comes with a 5-year warranty.

Uploaded by

ginello.pienello
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
40 views2 pages

HRP 600 Spec

The HRP-600 series is a 600W single output power supply with a built-in active PFC function and high efficiency up to 89%. It offers multiple output voltage options ranging from 3.3V to 48V, with various protections including short circuit and over temperature. The power supply is designed for a wide range of operating conditions and comes with a 5-year warranty.

Uploaded by

ginello.pienello
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

600W Single Output with PFC Function HRP-600 series

Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.94
High efficiency up to 89%
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in constant current limiting circuit
Built-in cooling fan ON-OFF control
Built-in DC OK signal
Built-in remote sense function
All using 105 long life electrolytic capacitors
5 years warranty

SPECIFICATION
MODEL HRP-600-3.3 HRP-600-5 HRP-600-7.5 HRP-600-12 HRP-600-15 HRP-600-24 HRP-600-36 HRP-600-48
DC VOLTAGE 3.3V 5V 7.5V 12V 15V 24V 36V 48V
RATED CURRENT 120A 120A 80A 53A 43A 27A 17.5A 13A
CURRENT RANGE 0 ~ 120A 0 ~ 120A 0 ~ 80A 0 ~ 53A 0 ~ 43A 0 ~ 27A 0 ~ 17.5A 0 ~ 13A
RATED POWER 396W 600W 600W 636W 645W 648W 630W 624W
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p 200mVp-p 240mVp-p
OUTPUT VOLTAGE ADJ. RANGE 2.8 ~ 3.8V 4.3 ~ 5.8V 6.8 ~ 9V 10.2 ~ 13.8V 13.5 ~ 18V 21.6 ~ 28.8V 28.8 ~ 39.6V 40.8 ~ 55.2V
VOLTAGE TOLERANCE Note.3 2.0% 2.0% 2.0% 1.0% 1.0% 1.0% 1.0% 1.0%
LINE REGULATION 0.5% 0.5% 0.5% 0.3% 0.3% 0.2% 0.2% 0.2%
LOAD REGULATION 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5%
SETUP, RISE TIME 1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.) 16ms/230VAC 16ms/115VAC at full load
VOLTAGE RANGE Note.5 85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF>0.94/230VAC PF>0.99/115VAC at full load
INPUT EFFICIENCY (Typ.) 78.5% 82% 87% 88% 88% 88% 89% 89%
AC CURRENT (Typ.) 8.5A/115VAC 5A/230VAC
INRUSH CURRENT (Typ.) 35A/115VAC 70A/230VAC
LEAKAGE CURRENT <1.2mA / 240VAC
105 ~ 135% rated output power
OVERLOAD
Protection type : Constant current limiting, recovers automatically after fault condition is removed
3.96 ~ 4.62V 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V 57.6 ~ 67.2V
OVER VOLTAGE
PROTECTION Protection type : Shut down o/p voltage, re-power on to recover
80 5 (TSW1)detect on heatsink of power transistor
OVER TEMPERATURE 90 5 (TSW2) detect on heatsink of power doide for 3.3V,5V,7.5V ; 100 5 (TSW2) detect on main power output choke for others
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
DC OK SIGNAL PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V
FUNCTION
FAN CONTROL (Typ.) Load 35 15% or RTH2 50 Fan on
WORKING TEMP. -40 ~ +70 (Refer to "Derating Curve")
WORKING HUMIDITY 20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT 0.03%/ (0 ~ 50 )
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved
SAFETY & WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
EMC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
(Note 4) EMC EMISSION Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A
MTBF 140.6K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION 218*105*63.5mm (L*W*H)
PACKING 1.5Kg;8pcs/13Kg/1.34CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.

File Name:HRP-600-SPEC 2011-08-09


600W Single Output with PFC Function HRP-600 series

Mechanical Specification Case No. 977A Unit:mm


152.4 32.8

20.75
O/P
1

11
4-M4 L=6
2
Air flow
3
direction

63.5

105
9.2
4
I/P 5
8.2

1 6
2
10

1 3
3 2 4

CN100
LED
SVR1
(Vo ADJ.)
218
152.4 32.8

8-M4 L=4 (Both Sides) 18max.


12max.

38.3
63.5
12.5
AC Input Terminal Pin No. DC Output Terminal Pin No. Connector Pin No. Assignment(CN100) : HRS DF11-4DP-2DS or equivalent
Assignment Assignment Pin No. Assignment Mating Housing Terminal
Pin No. Assignment Pin No. Assignment 1 DC-OK
1 AC/L 1~3 -V 2 GND HRS DF11-4DS HRS DF11-**SC
2 AC/N 4~6 +V 3 +S or equivalent or equivalent
3 FG 4 -S

Block Diagram
PW M fosc : 70KHz
+S
ACTIVE RECTIFIERS RECTIFIERS
EMI INRUSH POWER +V
I/P FILTER & &
CURRENT SWITCHING -V
LIMITING PFC FILTER
-S

O.T.P. O.L.P.
FG DETECTION
CIRCUIT DC OK
O.T.P.
PFC PWM
CONTROL CONTROL O.V.P.

Derating Curve Output Derating VS Input Voltage

125 100

90
100
80
80
70
LOAD (%)

60
LOAD(%)

50

50

20 40

-40 0 10 20 30 40 50 60 65 70 (HORIZONTAL) 85 100 125 135 155 264

AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz

File Name:HRP-600-SPEC 2011-08-09

You might also like