SL POWER
ME40 Series
40 Watts Single Output External Power Adapter
Medical Grade
Advanced Energy’s SL Power ME40 series of desktop and AT A GLANCE
wall-plug AC-DC external power adapter comprises five
output models. All models feature medical safety approvals
Total Power
and accept a universal input of 90 to 264 VAC. ME40 series
40 Watts
power adapters provide up to 40 Watts of output power with
IP22 rated enclosure and are ideal for applications that are Input Voltage
used in environments where AC mains power may be noisy or 90 to 264 VAC
unstable and equipment shutdown is not an option.
# of Outputs
Single
SPECIAL FEATURES SAFETY
A high performance power supply IEC/EN/UL60601-1, 3rd edition
designed for Medical applications CE Mark
Great EMI, EMC, and noise UKCA Mark
performance ensures easy integration
into the end equipment
Up to 40 W of AC-DC Power
IP22 Rated Enclosure*
Meets EN55011/CISPR11, FCC Part
15.109 Class B Conducted & Radiated
Emissions, with 6db Margin
Meets UL/EN/IEC60601-1-2, 4th
edition for EMC
>8 Years E-Cap Life
>1,000,000 Hours MTBF
3 Years Warranty
Meets DoE Efficiency Level VI
Requirements
RoHS Compliant
Note: *IP22 does not include interchangeable blade versions.
©2022 Advanced Energy Industries, Inc.
ME40
ELECTRICAL SPECIFICATIONS
Input
Input range 100 to 240 VAC, ±10%, 47 to 63 Hz, 1Ø
Input current 1.2 A @ 115 VAC, 0.6 A @ 230 VAC
Inrush current 40 A max., cold start @ 264 VAC input
Input fuses F1, F2: 2 A, 250 VAC fuses (line & neutral lines) provided on all models
Leakage current
Input to GND <500 μA @ 264 VAC, 60 Hz, NC
Output to Earth <4 mA @ 264 VAC, 60 Hz, NC
Efficiency 87%, Typical
Common Mode Noise High frequency (100kHz to 20MHz); <40mA pk-pk
No load input power <0.1 W per DoE Efficiency Level VI Requirements
Output
Output voltage See models chart on page 5
Output power 40 W continuous - See models chart for specific voltage model ratings
Turn on time Less than 700 mS @ 115 VAC, full load
Hold-up time 20 mS min., at full load, 100 VAC input
Ripple and noise See models chart on page 5
Transient response 500 μS response time for return to within 0.5% of final value for any 50% load step over the range of 5% to
100% of rated load, Δi/Δt < 0.2 A/μS.
Max. voltage deviation is ±3.5%
Regulation See models chart on page 5
Reliability
MTBF >1,000,000 hours, full load, 110 VAC & 220 VAC input, 25°C amb., per Telcordia 332 Issue 6, Stress Method
E-cap Life >8 years life based on calculations at 115VAC/60Hz & 230VAC/50Hz, ambient 25°C at 24 hrs per day, 365
days/year, 6 power up cycles per day
Protection
Overtemperature protection Will shutdown upon an overtemperature condition, auto-recovery
Overload protection 130% to 180% of rating, hiccup mode
Overvoltage protection Hiccup mode, see models chart on page 5 for OVP range
Short circuit protection Hiccup mode, auto-recovery
Safety
Safety standards Approved to EN/IEC/UL60601-1, 3rd edition
Drop test 1.4 m from table top to wooden platform, 6 faces
Isolation
Input to Output: 4000 VAC
Isolation Input to Ground: 1500 VAC
Output to Ground: 1500 VAC
Note:
All specifications are typical at nominal input, full load, at 25°C ambient unless noted.
2 advancedenergy.com
ME40
DERATING CHART
EMI/EMC COMPLIANCE
Conducted emissions IEC60601-1-2/EN55011/CISPR11 Class B, FCC Part 15, Class B, 6db margin typ., at 115 VAC and 230VAC
Radiated emissions IEC60601-1-2/EN55011/CISPR11 Class B, FCC Part 15, Class B, 3db margin typ., at 115 VAC and 230VAC
Electro-static discharge (ESD)
EN55024/IEC61000-4-2, Level 4: ±8 kV contact, ±15 kV air, Criteria A
immunity on power ports
Radiated RF EM fields susceptibility EN55022/EN61000-4-3, 10 V/m, 80 MHz to 2.7 GHz, 80% AM at 1 kHz
Electrical Fast Transients (EFT)/Burst
EN55024/IEC61000-4-4, Level 4, ±4 kV, 100 kHz rep rate, 40 A, Criteria A
immunity
Surges, line to line (Diff mode)
EN55024/IEC61000-4-5, Level 4, ±2 kV DM, ±4 kV CM, Criteria A
and line to ground (CMN mode)
Conducted disturbances induced by EN55022/IEC61000-4-6, 3.6V/m - Level 4, 0.15 MHz to 80 MHz; and 12 V/m in ISM and amateur radio bands
RF fields between 0.15 MHz and 80 MHz, 80% AM at 1 kHz
Rated power frequency magnetic
EN55024/IEC1000-4-8, Level 4: 30 A/m, 50 Hz / 60 Hz
fields
EN55024/IEC/EN61000-4-11:
--100% dip for 20 mS, Criteria A
Voltage interruptions, Dips, Sags &
--100% dip for 5000 mS (250/300 cycles), Criteria B
Surges
--60% dip for 100 mS, Criteria B
--30% dip for 500 mS, Criteria A
Harmonic current emissions EN55011/EN61000-3-2, Class A
Flicker test EN61000-3-3
Note:
All specifications are typical at nominal input, full load, at 25°C ambient unless noted.
advancedenergy.com 3
ME40
ENVIRONMENTAL SPECIFICATIONS
-20°C to +70°C
Operating temperature
Start up at -40°C, full load (warmup period before all parameters are within published specifications)
Storage temperature -40°C to +85°C
Relative humidity 5% to 95%, non-condensing
Weight 250 grams
Temperature derating See derating chart
Operating: to 4000 m
Altitude
Non-operating: -500 ft to 40000 ft
Operating: 0.003 g/Hz, 1.5 grams overall, 3 axes, 10 min/axis, 1 Hz to 500 Hz
Non-Operating: random waveform, 3 minutes/axis, 3 axes and sine waveform,
Vibration
Vib. frequency/acceleration: 10Hz to 500 Hz/1g, sweep rate of 1 oct/minutes,
Vibration time of 10 sweeps/axes, 3 axes
Operating: Half-sine, 20gpk, 10ms, 3 axes, 6 shocks total
Non-operating: Half-sine waveform
Shock
Impact acceleration of 100G, Pulse duration of 6ms
Number of shocks: 3 for each of the three axis
Note:
All specifications are typical at nominal input, full load, at 25°C ambient unless noted.
MECHANICAL DRAWING
IEC60320 C14 Receptacle, 2.5mm x 5.5mm x 9.5mm Barrel Connector Interchangeable N.A. Blade, 2.5mm x 5.5mm x 9.5mm Barrel Connector
Notes:
1. Weight: 250 grams.
2. All dimensions in mm.
3. Interchangeable blade models come with North American blade fitted. For other blades (EU, UK, AU) order
blade kit KT1027K.
4. The unit should not be covered or enclosed to protect against excessive case temperature rise.
5. Pins 4,5,6 are located closest to the locking tab.
4 advancedenergy.com
ME40
ORDERING INFORMATION
Output Output Ripple & Line Load Overvoltage Input
Model Number Volts Output Connector
Current Power Noise1 Regulation Regulation Trip Range Configuration
ME40A0503F01 5.0 V 5.0 A 25 W 100mV pk-pk ± 1% ± 5% 6.0V to 7.5V
ME40A0903F01 9.0 V 4.0 A 36 W 100mV pk-pk ± 1% ± 5% 10.8V to 13.5V 2.5 x 5.5 x 9.5mm Class I Desktop,
ME40A1203F01 12.0 V 3.4 A 40 W 120mV pk-pk ± 1% ± 5% 14.4V to 18.0V Straight Barrel Type, IEC60320 C14
ME40A1803F01 18.0 V 2.22 A 40 W 180mV pk-pk ± 1% ± 5% 21.6V to 27.0V Center Positive Receptacle2
ME40A2403F01 24.0 V 1.70 A 40 W 240mV pk-pk ± 1% ± 5% 28.8V to 33.6V
ME40A0503N01 5.0 V 5.0 A 25 W 100mV pk-pk ± 1% ± 5% 6.0V to 7.5V
ME40A0903N01 9.0 V 4.0 A 36 W 100mV pk-pk ± 1% ± 5% 10.8V to 13.5V 2.5 x 5.5 x 9.5mm Class II Desktop,
ME40A1203N01 12.0 V 3.4 A 40 W 120mV pk-pk ± 1% ± 5% 14.4V to 18.0V Straight Barrel Type, IEC60320 C8
ME40A1803N01 18.0 V 2.22 A 40 W 180mV pk-pk ± 1% ± 5% 21.6V to 27.0V Center Positive Receptacle
ME40A2403N01 24.0 V 1.70 A 40 W 240mV pk-pk ± 1% ± 5% 28.8V to 33.6V
ME40A0503Q01 5.0 V 5.0 A 25 W 100mV pk-pk ± 1% ± 5% 6.0V to 7.5V
ME40A0903Q01 9.0 V 4.0 A 36 W 100mV pk-pk ± 1% ± 5% 10.8V to 13.5V 2.5 x 5.5 x 9.5mm Class II Desktop,
ME40A1203Q01 12.0 V 3.4 A 40 W 120mV pk-pk ± 1% ± 5% 14.4V to 18.0V Straight Barrel Type, IEC60320 C18
ME40A1803Q01 18.0 V 2.22 A 40 W 180mV pk-pk ± 1% ± 5% 21.6V to 27.0V Center Positive Receptacle
ME40A2403Q01 24.0 V 1.70 A 40 W 240mV pk-pk ± 1% ± 5% 28.8V to 33.6V
ME40A0503B01 5.0 V 5.0 A 25 W 100mV pk-pk ± 1% ± 5% 6.0V to 7.5V
Class II Wall-Plug,
ME40A0903B01 9.0 V 4.0 A 36 W 100mV pk-pk ± 1% ± 5% 10.8V to 13.5V 2.5 x 5.5 x 9.5mm Interchangeable
ME40A1203B01 12.0 V 3.4 A 40 W 120mV pk-pk ± 1% ± 5% 14.4V to 18.0V Straight Barrel Type, Blades
ME40A1803B01 18.0 V 2.22 A 40 W 180mV pk-pk ± 1% ± 5% 21.6V to 27.0V Center Positive (North American
Blade included)3
ME40A2403B01 24.0 V 1.70 A 40 W 240mV pk-pk ± 1% ± 5% 28.8V to 33.6V
ME40A0503C01 5.0 V 5.0 A 25 W 100mV pk-pk ± 1% ± 5% 6.0V to 7.5V
ME40A0903C01 9.0 V 4.0 A 36 W 100mV pk-pk ± 1% ± 5% 10.8V to 13.5V 2.5 x 5.5 x 9.5mm Class II Wall-Plug,
ME40A1203C01 12.0 V 3.4 A 40 W 120mV pk-pk ± 1% ± 5% 14.4V to 18.0V Straight Barrel Type, Fixed North
ME40A1803C01 18.0 V 2.22 A 40 W 180mV pk-pk ± 1% ± 5% 21.6V to 27.0V Center Positive American Blades4
ME40A2403C01 24.0 V 1.70 A 40 W 240mV pk-pk ± 1% ± 5% 28.8V to 33.6V
Notes:
1. Measured at the output connector, with noise probe directly across output and load terminated with 0.1 μF ceramic and 10 μF low ESR capacitors. For 5 V and 6 V models, values
listed are typical 100 mV pk-pk maximum with 0.1 μF ceramic and 47 μF low ESR capacitors used at measurement point.
2. For input Class I models: For AC GND connected to output common (-), insert a “B” in the part number where the “A” is located (ME40B1203F01).
3. Order blade kit KT-1027K for other blades (EU, UK, Australia).
4. For EU fixed blades, replace “C” in the model number with “M”, for UK blades, replace “C” with “G”, for Australia blades, replace “C” with “H”.
5. All specifications are typical at nominal input, full load, at 25°C ambient unless noted.
advancedenergy.com 5
ME40
CONNECTOR INFORMATION
Standard models include a 2.5mm x 5.5mm x 9.5mm straight barrel type connector (Ault #3), center positive. Other standard options are listed
below. The “03” in the standard model number is replaced by the applicable digits below.
Connector Connector
Description Description
No. No.
2.1 x 5.5 x 9.5 mm straight barrel plug - 2.5 x 5.5 x 9.5 mm straight barrel plug,
02 45
Center positive locking - Center positive
2.5 x 5.5 x 9.5 mm straight barrel plug -
3-pin Snap n Lock, Kycon Kpp - 3P
03 Center positive (Standard models) 48
or equivalent (Pin 1 = (+); pin 2 = (-))
5-pin DIN - 180 male connector (Pins 3,5 = (+);
4-pin Snap n Lock, Kycon Kpp - 4P
12 pins 1,2,4 = (-)) 49
or equivalent (Pins 1,3 = (+); pins 2,4 = (-))
6-pin DIN male connector (Pins 1,2 = (+);
6-pin Minifit - Molex 39-01-2060 or equivalent
22 pins 4,5 = (-)) 51
(Pins 1,4 = (+); pins 3,6 = (-))
8-pin DIN male connector (Pins 3,7 = (+);
23 pins 1,4,6,8 = (-); shell = FG) 65 Stripped and tinned leads
9-pin “D” type, female (Pin 8 = (+); pin 5 = (-);
2.1 x 5.5 x 11 mm right angle barrel plug
32 all others = NC) 70
(High retention) - Center positive
2.5 x 5.5 x 12.5 mm straight barrel plug -
2.5 x 5.5 x 11 mm right angle barrel plug
33 Center positive 71
(High retention) - Center positive
2.1 x 5.5 x 9.5 mm right angle barrel plug - 2.1 x 5.5 x 9.5 mm straight barrel plug
40 72
(High retention) - Center positive (High retention, no spark) - Center positive
2.5 x 5.5 x 9.5 mm right angle barrel plug - 2.5 x 5.5 x 9.5 mm straight barrel plug
41 73
(High retention) - Center positive (High retention, no spark) - Center positive
2.1 x 5.5 x 11 mm straight barrel plug -
42 74 EIAJ#5 style connector - Central positive
(High retention) - Center positive
2.5 x 5.5 x 11 mm straight barrel plug - Micro USB
43 99
(High retention) - Center positive
2.1 x 5.5 x 9.5 mm straight barrel plug,
44
locking - Center positive
6 advancedenergy.com
ABOUT ADVANCED ENERGY
Advanced Energy (AE) has devoted more than three
decades to perfecting power for its global customers. AE
designs and manufactures highly engineered, precision
power conversion, measurement and control solutions for
mission-critical applications and processes.
Our products enable customer innovation in complex
applications for a wide range of industries including
semiconductor equipment, industrial, manufacturing,
telecommunications, data center computing, and medical.
With deep applications know-how and responsive service
and support across the globe, we build collaborative
partnerships to meet rapid technological developments,
propel growth for our customers, and innovate the future of
power.
TRUST
For international contact information,
visit advancedenergy.com.
Specifications are subject to change without notice. Not responsible
powersales@aei.com (Sales Support) for errors or omissions. ©2022 Advanced Energy Industries, Inc. All rights
productsupport.ep@aei.com (Technical Support) reserved. Advanced Energy®, and AE® are U.S. trademarks
+1 888 412 7832 of Advanced Energy Industries, Inc.
ENG-ME40-01 11.23.22