Torque Sensor Position Sensor Battery S1 S2 S3 S4: Tap Nominal 50/60Hz W 220/230 X 380/400 Y 400,415/420 Z 440/460 Type 1

The document contains a circuit diagram for a remote control system with various components, including power supply options and relay configurations. It provides details on fuse specifications, control connections, and operational notes for the system. Additionally, it outlines the settings for indication relays and battery requirements for maintaining contact indications.

Uploaded by

mail
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
56 views2 pages

Torque Sensor Position Sensor Battery S1 S2 S3 S4: Tap Nominal 50/60Hz W 220/230 X 380/400 Y 400,415/420 Z 440/460 Type 1

The document contains a circuit diagram for a remote control system with various components, including power supply options and relay configurations. It provides details on fuse specifications, control connections, and operational notes for the system. Additionally, it outlines the settings for indication relays and battery requirements for maintaining contact indications.

Uploaded by

mail
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

W

CIRCUIT DRAWN WITH POWER SUPPLY OFF FOR TYPICAL REMOTE CONTROL
M 2 W (C)
2 DETAILS, SEE DOCUMENT
3
3 V
4
1 V (B)
3
PHASE
RWS133
SUPPLY
U
U (A)
3 1 TR AN S F OR ME R TAP P IN G OP TION S
6

5 T ap Nominal 50/60Hz
U V W E TYP E 1
FS1
W 220/230
X 380/400
C1 C2 Y 400,415/420
U W X Y Z
Z 440/460
F US E F S 1= 250mA A NTI-S UR G E
SK2 TYP E 2
0VAC 1 W 346/380
TRANSISTOR SWITCHING FOR
PS1 X 480/500
24VDC CONTACTORS (IQ10-35) 120VAC 4
RELAYS ONLY FITTED WHEN Y 240/240
0VDC
120VAC CONTACTOR IS FITTED 3 4 24VDC Z 550/575
FOR IQ40,70,90,91 & 95 24VDC 6 NOMINAL SUPPLY
F US E F S 1= 250mA A NTI-S UR G E
_ 5 (OUTPUT)

+
AVAILABLE WHEN TYP E 3
SK14 POWERED ONLY
X 660/660-690
0VDC 1
Y 690/-
24VDC 2 F US E F S 1= 150mA A NTI-S UR G E
SK13

26 WAY REFER TO SHEET 2 FOR NOTES


& OPTION PCB'S IF FITTED

SK3 SK13 SK14 DO NOT CONNECT TO


6 1 42 TERMINALS MARKED
MONITOR RELAY
5 3 43
= PLUG & SOCKET CONNECTION
TORQUE 4 2 44
3
2
SK7
SENSOR 1 1 6
SK8 BREAT AT CT/LS S1 8 7
POSITION 10 WAY 2 8
SENSOR BREAK AT OT/LS S2 7 9
SK9
3 10
BATTERY - 4
MAKE AT FULLY SHUT S3 6 11
4 12
+
1 MAKE AT FULLY OPEN S4 5 13
FS2 (IF FITTED) 100mA SK4
CLOSE 9 33
STOP/ MAINTAIN 10 34
50% SK6 OPEN 8 35
COMMON -VE 1 36
18 WAY
ESD 12 25
OPEN INTERLOCK 13 37
CLOSE INTERLOCK 14 38
COMMON -VE 5 31
SK1 SK2
SLOT A SLOT B

Iss Date Chkd Revision Details IQ SET + INDICATION RELAYS (2220-00) + PLUG &
1 300622 PJW First Issue www. .com SOCKET
ROTORK CONTROLS LTD ROTORK CONTROLS INC Drawn by: NJC Circuit Diagram Number Issue Sheet
BATH, BA1 3JQ ROCHESTER Date : 300622 No
ENGLAND NY 14624, USA
Base WD: 100S0012
Job No : - -
100S0012 1
1
of 2
Tel:01225-733200 Tel:585-247-2304 MI No : - - 92 94 B1 C1 B2 C2 J1 T1
IQ3
CIRCUIT DRAWN WITH POWER SUPPLY OFF

SLOT A
SK1
SLOT A SK3
EXTRA CHANGE OVER CONTACTS

2 14
FOR OTHER SETTINGS SEE PUB002-038

S5 3
BREAK AT FULLY SHUT 16
DEFAULT SETTINGS SHOWN

1 15
5 17
BREAK AT FULLY OPEN S6 6 19
4 18
8 20
MAKE WHEN STALLED S7 9 24
7 21
11 30
MAKE ON LOSS OF PHASE S8 12 47
10 46

NOTES 3.INDICATION:
1.FUSES: -For typical position, status and alarm indication see PUB002-041.
-PS1 is a self-resetting fuse. -“S” contacts are user configurable and are shown in their default
-Refer to publication PUB002-039 for approved fuses FS1 and FS2. setting.
-Actuator rated voltage specified on nameplate. Voltage tolerance +/-10%, -Voltage applied to indication contacts must not exceed 120V AC or
applies for rated torque performance; duty cycle is not guaranteed. DC
2.CONTROL: -Maximum individual Switching power must not exceed 60W inductive
-Supply provided on terminals 4 & 5 only available when power is applied to the load or 150W resistive load
actuator : -Total switched current for contacts S1 to S4 must not exceed 8A, with
-Max external load 5W at 24Vdc / 5VA at 120Vac maximum individual current of 5A.
-Connect motor control contactor coils in series with CT/LS S1(closed) and OT/LS
S2(open). 4.BATTERY:
-Voltage applied to CT/LS & OT/LS must not exceed 120V AC or DC. -Battery maintains local and remote “S” contact indication only.
-Maximum individual switching power must not exceed 60W inductive or 150W -Refer to installation manual for approved replacement battery types.
resistive.
Circuit Diagram Number Issue Sheet
No
2
See Sheet 1 for all Revision details/information 100S0012 1 of 2