0% found this document useful (0 votes)
45 views3 pages

Key GPM400T DS

The GP-M400T is a built-in temperature sensor with a rated pressure of 0 to +5802 PSI and a maximum allowable pressure of 7252 PSI. It features a display range for pressure and temperature, with various output options and environmental resistance ratings including IP67. The device is suitable for liquid that does not corrode the fluid contact part and operates within a temperature range of -20 to +100°C.

Uploaded by

argudin1993
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
45 views3 pages

Key GPM400T DS

The GP-M400T is a built-in temperature sensor with a rated pressure of 0 to +5802 PSI and a maximum allowable pressure of 7252 PSI. It features a display range for pressure and temperature, with various output options and environmental resistance ratings including IP67. The device is suitable for liquid that does not corrode the fluid contact part and operates within a temperature range of -20 to +100°C.

Uploaded by

argudin1993
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Data Sheet

GP-M400T
Main Unit, Built-in temperature sensor Positive-pressure Type, 40 MPa

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Specifications
Model GP-M400T
Rated pressure 0 to +5802 PSI
(0 to +40 MPa)
Possible display range –580.1 to +6381.7 PSI
(–4.00 to +44.00 MPa)
Allowable pressure 7252 PSI (50 MPa)
Zero-cut pressure value ±0.5% of F.S.
Burst pressure 14504 PSI (100 MPa)
Display resolution 1.5 PSI (0.01 MPa)
Fluid type Liquid that will not corrode the fluid contact part
Type of pressure Gauge pressure
Precision ±1.0% of F.S. or less*1
Repeatability ±0.3% of F.S. or less*2
Temperature characteristics ±0.6% of F.S. / 10°C 50°F
Connection port G3/4 (Changes to R1/8 male, R1/4 male, R3/8 male, G1/4 female, NPT1/8 male,
and NPT1/4 male with available adapters.)
Box rotation angle Maximum 330°
Medium temperature –20 to +100°C –4 to +212°F (no freezing/condensation)*3*4
Power voltage 10 to 30 VDC, Ripple (P-P): 10% max., Class 2 or LPS
Current consumption 60 mA or less (when 24 V: 30 mA or less; when 12 V: 50 mA or less. Excluding
output)*5
Possible display range (temperature) –32 to +112°C –25.6 to +233.6°F
Display method 4 column digital LED white/Vertical inversion of display is possible
Display resolution (temperature) 0.1°C 32.18°F
Liquid contact temperature measurement accuracy ±3.5°C ±6.3°F (at an ambient temperature of 25°C 77°F)*6
Display method Status indicator (orange, green, red, blue), output indicator 1 (orange), output
indicator 2 (orange), temperature indicator (white), communication indicator
(green)
Pressure hysteresis During hysteresis mode: variable (Hysteresis is the difference between the upper
setting value and the lower setting value)
During window mode: fixed (0.5% of F.S.)
Pressure Control output Selectable from 3 to 5000 ms
responsiveness
Analog output As above +2 ms (90% response)
Output Output 1 control output NPN/PNP open collector (Selectable) 30 V or less,
Output 2 Max. 100 mA Residual voltage for the Main Unit is 1 V or less, N.O./N.C.
Output 2 Control output
selectable
replacement type
Analog output Pressure analog output/temperature analog output (selectable), 4–20 mA;
maximum load resistance 260 Ω
Network compatibility IO-Link*7

KEYENCE AMERICA 1-888-539-3623(Toll Free) https://www.keyence.com 2025/03/28 Page 1 of 3


Data Sheet

Environmental Enclosure rating IP67


resistance
Ambient temperature –20 to +80°C –4 to +176°F (no freezing or condensation)*8
Relative humidity 35 to 85% RH (no condensation)*8
Vibration resistance IEC60068-2-6 20 G (10 to 2000 Hz In each direction of X, Y, Z for 2 hours)
Shock resistance IEC60068-2-27 50 G (11 ms In each direction X, Y, Z 3 times)
Material Wetted part Pressure port: SUSXM7/Diaphragm pressure port: Al2O3/O-Ring: FKM
properties
Other parts Housing metal portion: SUS304, SUS303; Housing plastic portion: PPSU; Air
hole*9: PTFE, nickel-plated brass.
Applicable cable M12 connector 4 pin
Weight Approx. 150 g 5.29 oz

*1 This is the value when considering linearity + hysteresis + repeatability in a stable environment of 23°C 73.4°F.
*2 The repeatability, based on consistent conditions, is the difference in the detection points at the time of fluctuations in the repetition.
*3 When the temperature of the piping exceeds 80°C 176°F, do not connect the cable.
*4 Condensation may cause measurement failure or breakage. To prevent condensation, take the following measures:
• Make sure the ambient temperature is the same or lower than the fluid temperature.
• Use A/C for dehumidification.
• Keep the sensor 30 cm 11.81" or more from the cooling pipe using connective piping.
*5 Consumption current including output is 0.3 A and under.
*6 This is the value when the measured fluid is water and a KEYENCE adapter is used.
*7 IO-Link specification v1.1/COM2 (38.4 kbps) is supported.
*8 See "7" in "Other precautions" on P.13 for measures on preventing condensation.
*9 Only GP-M001T/M010T/M025T

KEYENCE AMERICA 1-888-539-3623(Toll Free) https://www.keyence.com 2025/03/28 Page 2 of 3


Data Sheet

Dimensions
* Download CAD file or product manual for larger image/text and more detail.

KEYENCE AMERICA 1-888-539-3623(Toll Free) https://www.keyence.com 2025/03/28 Page 3 of 3