PRESSURE
SERIES 636
FIXED RANGE PRESSURE TRANSMITTER
Stainless Steel, Explosion-Proof, Accuracy ±0.30%, 4-20 mA or 1-5 VDC Signal
CALIBRATION SERVICES AVAILABLE
3/4 NPT #22 AWG LEADS 24 [609.60]
LEADS PLUS SHIELD/DRAIN
1-1/4 [31.75] HEX 1-1/8
[28.58]
Ø1-25/32 4-1/16
[45.24] [103.19]
1 [25.40] HEX 1-1/4
[31.75]
1/2 NPT
The Series 636 Fixed Range Pressure Transmitter is a low cost, fixed range, SPECIFICATIONS
stainless steel transmitter with ±0.30% accuracy. It is designed to continuously Service: Liquid, gas or vapor.
measure pressure for years in even the toughest environmental and media conditions. Wetted Materials: 316L SS.
Transmitters are explosion-proof, (FM approved) and meet NACE standards for off- Fill Fluid: DC 200 silicone (standard).
shore applications. Accuracy: ±0.30% of calibrated span including linearity hysteresis and repeatability
(BFSL) at 25°C (77°F) and 12 VDC excitation.
BENEFITS/FEATURES Stability: ±0.5% of upper range limit for six months.
• Long service life and lower cost to maintain reduces total cost of ownership Temperature Limits: Electronics (ambient): -40 to 140°F (-40 to 60°C); Process
• Explosion-proof housing for use in applications where protection of process and interface: -40 to 212°F (-40 to 100°C).
personnel is needed Pressure Limits: 300% upper range limit.
Compensated Temperature Range: -20 to 180°F (-29 to 82°C).
APPLICATIONS Thermal Effect: (includes zero and span). Between -20 and 180°F (-29 and 82°C).
• Off-shore ±2.0% per 50°F (28°C).
• Process applications Power Requirements: 12-30 VDC (636), 8-14 VDC (636LP), reverse polarity
protection.
Output Signal: 4-20 mA DC, limited to 30 mA DC (636), 1-5 VDC (636LP).
Single Pressure Transmitters
MODEL CHART Zero and Span Adjustments: Null: 4.0 mA ±2% span (636),1 VDC ±1% span
Model Output Operating Range, psi Operating Range, bar (636LP); Span: 16.0 mA ±1% span (636), 4 VDC ±1% span (636LP).
636-0 4-20 mA 0 to 15 0 to 1 Loop Resistance: 900 Ω max @ 30 V.
636-1 4-20 mA 0 to 30 0 to 2 Electrical Connection: 3/4˝ female NPT 24˝ (61 cm), 22 AWG.
636-2 4-20 mA 0 to 100 0 to 7 Process Connection: 1/2˝ female NPT.
636-3 4-20 mA 0 to 300 0 to 20 Enclosure Rating: NEMA 4 (IP56).
Weight: 0.83 Ib (374 g).
OPTIONS Compliance: CSA, FM.
Use order code: Description FM and CSA approved explosion-proof for Class I, Division 1, Groups B, C, and D,
NISTCAL-PT1 NIST traceable calibration certificate Class II Groups E, F, and G Class III.
102 DWYER INSTRUMENTS, LLC | dwyer-inst.com