Opti-Core™ Fiber Optic Indoor-Outdoor Asia Pacific
Cable with Tight Buffered Fibers SPECIFICATION SHEE T
specifications
The Opti-Core Fiber Optic family of cables shall contain 4 to 72 optical fibers. The fibers
shall be tight-buffered for easy termination with field-installable connectors. The cables
shall be flame rated for use indoors, complying with UL standards for riser and IEC
standards for Low Smoke/Zero Halogen (LSZH). The cables shall have UV resistant and
water blocking properties for use in outdoor environments. The cables shall have options
for singlemode (OS2) or multimode fibers (OM3 and OM4) to support 10 Gb/s network
transmission and beyond.
applications
• Can be used indoors and outdoors; a good choice for entrance facilities
• Typical applications include LAN backbones, backbones in data centers, and routing between telecommunications rooms
• This cable is suited for installation in ducts and on trays
standards and flame rating physical & mechanical properties
Telcordia GR-409-CORE (Indoor Fiber Optic Cable) Fiber count: 4 6 8 12 24 48 72
ISO 11801 (Generic Cabling for Customer Premises) Nominal outside
5.3 5.3 5.8 6.6 8.8 18.3 21.9
UL 1666 (Riser) diameter (mm):
IEC 60332 (Flame Retardant) Bend radius
IEC 61034 and IEC 60754-2 (Low Smoke and Zero Halogen) (Installation/short 20x cable outside diameter
or Zero Halogen to IEC 60754-1 term/with load):
RoHS Compliant Bend radius
(Operation/long 10x cable outside diameter
term/no load):
Weight (kg/km): 25 32 41 53 60 253 381
Tensile strength
c able c ons t r u c t ion (all- diele c t ric) (Installation/short 660 660 660 660 1320 1320 1320
term), N:
4 to 24 fibers: 900μm tight buffered fibers are protected by
water blocking strength members in a flame- Tensile strength
retardant outer jacket (Operation/long 200 200 200 200 400 400 400
term), N:
48 and 72 fibers: 4 or 6 sub-units with 12 fibers per sub-unit.
Cable has a dielectric central strength member Compressive
and 1-2 ripcords. Subunits are surrounded by strength (Crush), 1000 1000 1000 1000 1000 1000 1000
tape (Riser only) and outer jacket. Each sub-unit N/cm:
contains twelve 900μm tight buffered fibers, Compressive
water blocking strength members and a strength for
flame-retardant sheath. 500/10
FLKLZ12 (Crush),
Outer jacket: Outer sheath is Black. Material is flame-retardant, N/cm:
UV stabilized and resistant to water and moisture. Temperature range: Storage: -25°C to 70°C
Installation: 0°C to 50°C
Operation: -20°C to 60°C
Water penetration: 3m sample, no leakage after 24 hours
optical properties
Maximum OS2 Singlemode 0.7 dB/km @1310 nm,
attenuation: (ITU-T G.652.D): 0.7 dB/km @1550 nm
OM3 & OM4 3.5 dB/km @850 nm,
Multimode: 1.5 dB/km @1300 nm
FLKLZ12: 2.8 dB/km @850 nm,
1.0 dB/km @1300 nm
w w w. p a n d u i t .co m
Opti-Core™ Fiber Optic Indoor-Outdoor Cable with Tight Buffered Fibers
key features and benefits
900μm tight buffered fibers: Easy to handle, strip, and connectorize in the field
Flame retardant riser or LSZH Provides life safety benefits; meets industry standards for smoke and flame and is well suited for indoor
jacket: installations
Water swellable elements: Prevent the migration of water throughout the cable (longitudinally water blocked)
Sub-unit design with central Simplifies fiber identification, provides easy access and routing of fibers, increases cable durability
strength member:
Highest quality OM3 and OM4 Supports 10 Gb/s applications while maintaining compatibility with existing 50μm multimode systems
laser optimized fiber:
fiber color sequence
1 2 3 4 5 6 7 8 9 10 11 12
Blue Orange Green Brown Slate White Red Black Yellow Violet Pink Aqua
Fibers 13 through 24 repeat this color sequence and have a Black dash. Fiber 20 is light green with a black tracer.
ordering information
*Example: FLKLZ12 = OM4 12 Fiber Indoor-Outdoor Cable, LSZH, 900μm Tight Buffered Fibers
Character 1 2 3 4 5 6 7
Example* F L K L Z 1 2
1 and 2 – Fiber Product, Region 4 – Flame Rating 6 and 7 – Fiber Count
FL = Fiber Cable, Asia Pacific L = LSZH 04 = 4-fiber
R = Riser 06 = 6-fiber
3 – Cable Construction 08 = 8-fiber
K = Indoor-Outdoor Tight Buffered 5 – Fiber Type 12 = 12-fiber
All-Dielectric 9 = Singlemode OS2 9/125μm 24 = 24-fiber
X = Multimode OM3 50/125μm 48 = 48-fiber (OS2 only)
Z = Multimode OM4 50/125μm 72 = 72-fiber (OS2 only)
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
PANDUIT US/CANADA PANDUIT EUROPE LTD. PANDUIT SINGAPORE PTE. LTD. PANDUIT JAPAN PANDUIT LATIN AMERICA PANDUIT AUSTRALIA PTY. LTD.
Phone: 800.777.3300 London, UK Republic of Singapore Tokyo, Japan Guadalajara, Mexico Victoria, Australia
Phone: 44.20.8601.7200 Phone: 65.6305.7575 Phone: 81.3.6863.6000 Phone: 52.33.3777.6000 Phone: 61.3.9794.9020
For a copy of Panduit product warranties, log on to www.panduit.com/warranty
For more information
©2023 Panduit Corp.
Visit us at www.panduit.com ALL RIGHTS RESERVED.
Contact Customer Service by email: cs@panduit.com FBSP230-WW-ENG
or by phone: 800.777.3300 8/2023