AIIe DP
AIIe DP
Transmitter
       The      FCX–AIIe differential
   pressure (flow) transmitter accurately
   measures differential pressure, liquid
   level, gauge pressure or flow rate
   and transmits a proportional 4 to 20
   mA signal. The transmitter combines
   a unique silicon capacitance sensor
   with state-of-the-art microprocessor
   technology to provide exceptional
   performance and reliability.
Features
High Performance                                           Application Flexibility
Combine the proven variable capacitance                    Various features and options make the FCX–AIIe
measurement principle with a sensor machined from a        suitable for a wide variety of process applications:
single silicon wafer and the result is a performance       • All 316 and 316L SST wetted parts
specification traditionally reserved for the elite class   • 30:1 turndown for all ranges
transmitter. The standard accuracy of the FCX-AIIe         • Analog indicator orients in either the vertical or
±0.1% and long term stability is ± 0.2% for three years.     horizontal plane.
Isolated Sensor                                            • Full range of hazardous area approvals
The "Advanced Floating Cell" serves to increase the        • RFI filter and lightning arrester
mechanical integrity of the measuring cell by isolating    • 5-digit LCD meter with support for engineering units
the silicon sensor from adverse conditions present in
                                                           Output Linearization
normal process applications. This unique cell
                                                           In addition to selectable linear or square root outputs,
construction reduces total measurement error by
                                                           the AIIe can also be programmed to linearize a
minimizing the effects of varying process temperature,                                                                Barton Instrument Systems, LLC
                                                           differential pressure curve of up to 14 points. This
static pressure, and overpressure.                                                                                    900 S. Turnbull Canyon Road
                                                           programmable functionality renders the transmitter
                                                           suitable to tank volume applications.                      City of Industry, CA 91745
Communication Protocols
The FCX–AIIe communicates in both Fuji proprietary
                                                           Burnout Flexibility                                        T (626) 961-2547
and HART(r) protocol. Any HART®compatible device
                                                           The AIIe's burnout signal is adjustable via the hand
can communicate with the FCX–AIIe.                                                                                    F (626) 933-7241 (Sales)
                                                           held communicator to either under scale (3.2 to 3.8 mA)
                                                                                                                      e info@barton-instruments.com
                                                           over scale (20.8 to 21.6 mA) or output hold (last value)
                                                           complying with NAMUR NE43.
Specifications                                                                                                                                                S
FUNCTIONAL SPECIFICATIONS                                                                                                                                     Zero/span adjustment:
Service                                                                                                                                                        Adjustable via the HHC or external adjustment screw.
 Liquid, gas, or vapor                                                                                                                                        Damping:
Span and range limit                                                                                                                                           Adjustable between 0 to 32 seconds via the HHC
                                               DIFFERENTIAL PRESSURE                                                                                          Zero elevation/suppression:
                                                          Calibrated Span                                                                                      –100% to +100% of URL. Zero plus span not to exceed URL.
    Range              Minimum                                                                                          Maximum
    Code in w.c. (psi)   kPa                               mBar                                         in w.c. (psi)     kPa         mBar                    Normal/reverse action
                33              4            1.06         10.6                                               125          32           320                     Selectable from HHC.
                34             17            4.33         43.3                                               520          130          1300
                35            (2.5)          16.66        166.6                                              (72)         500          5000                   Burnout direction
                                                                                                                                                               Selectable from HHC
Vacuum Limitation                                                                                                                                              If self-diagnostic detects transmitter failure, the analog signal will
 Silicone fill sensor:                                                                                                  Silicone Oil (Code:Y & G)
                                                                                                                                                               be driven to either “Output Hold” (last value), “Output Overscale”
 (see diagram)                                                                                        101                                                      (between 20.8mA to 21.6mA) or “Output Underscale”
                                                          OPERATING PRESSURE , kPa abs (psi abs)
                                                                                                   (14.65)
 Fluorinated fill sensor:                                                                                                                                      (between 3.2mA to 3.8mA).
 66kPa abs /
                                                                                                                                                              Loop-check output
 500mm Hg abs /
                                                                                                        20                     Operating Area
                                                                                                                                                               Any constant signal between 3.8mA and 21.6mA via HHC.
 9.6 PSI abs                                                                                        (2.90)
 at 60°C max.                                                                                                                                                 Temperature limit
                                                                                                                                                               Ambient: –40 to +85°C ( –40 to +185°F)
Static pressure and                                                                                     4                                                        –20 to +80°C ( –4 to +176°F) for LCD indicator
over range limit                                                                                    (0.58)
                                                                                                                                                                 –40 to +60°C ( –40 to +140°F) for arrester option
 16 MPa (2300 psig)                                                                                    2.7
                                                                                                    (0.39)
                                                                                                                                                                 –10 to +60°C ( –14 to +140°F) for fluorinated oil filled transmitters
Output signal                                                                                                             Non-operating Area
                                                                                                                                                                 For explosion-proof units (flameproof or intrinsic safety), ambient
 4 to 20mA DC c/w                                                                                             – 40                     60              120       temperature must be within the limits specified in each standard.
 HART & Fuji Protocol                                                                                          (-40)                  (140)           (248)
                                                                                                                                                               Process: –40 to +120°C ( –40 to +248°F) for silicone fill sensor
                                                                                                                    PROCESS TEMPERATURE , °C (°F)
Power supply                                                                                                                                                     –20 to +80°C ( –4 to +176°F) for fluorinated oil fill sensor
 Transmitter operates                                                                                                                                          Storage: – 40 to +90°C ( –40 to +194°F)
 on 10.5V to 45V DC at transmitter terminals.                                                                                                                 Humidity limit
 10.5V to 32V DC for the units with optional arrester.                                                                                                         0 to 100% RH
Load limitations: see figure below                                                                                                                            Communication
                                                                                                                                                               Hart or Fuji proprietary protocol.
                       2000
                                      1533 Ω                                                                                                                  Programmable output linearization function:
 LOAD RESISTANCE , Ω
Process connections:
 1/4-18 NPT or Rc1/4 on 54mm (2-1/8’’) centers, as specified.                                  Accessories
 Meets DIN 19213.                                                                              Flange adapters:
Process-wetted parts material:                                                                  Converts process connection to 1/2-14 NPT in carbon steel or in
                                                                                                316 stainless steel.
   Material
     code                                                    Wetted                            Hand-held communicator:
  (7th digit   Process cover       Diaphragm              sensor body             Vent/drain
   in Code                                                                                      Installed with Fuji Proprietary Protocol.
  symbols)
       V       316 stainless     316L stainless           316 stainless       316 stainless
               steel             steel                    steel               steel
Notes:
1 The static pressure of any transmitter with B7M, L7M or 304SS bolting must be limited to 1450 psi (+10MPa) max.
2 Specify SS bolts for all tropicalized service
3 Specify this field only when necessary
Outline Diagram
FCX-AIIe Differential Pressure Transmitter
           Bracket may be
           wall mounted.
           Four 9 mm (3/8’’)
           diameter holes,
                                                                                                         Zero Adj. Screw
    2’’ pipe                                              Detail “A”
                                                     Pressure Connection
                                                                                                                                                                                  (1-11/16’’)
                                                                                                                               (3-1/16’’)
                                                                                                                                                                                     43.5
                                                                                                                                                                120 (4-11/16’’)
                                                                                                                                                130 (5-1/4’’)
                                                                                                                        ø 80
                                                                                                                                                                                                                                                (3-1/16’’)
                                                                                                                                                                                                                                                  ø 80
                                                                                                                                   52.5
                                                                                                                                   (2’’)
                                      38
  U-Bolt                                                  Vent / Drain Plug
                                   (1-1/2’’)
                                  58               37
                               (2-5/16’’)        (1-7/16’’)
                                                                                 210                            27
                                                                               (8-1/4’’)                                 Detail “B”                                                                         154 (6’’)
                                                                                                           (1-1/16’’)
                                                                                                                         Conduit Connection
                                                                                                                                                                                                   59          43
                                                                                                                                                                                                (2-5/16’’) (1-11/16’’)
                                                                                                  With Field Indicator (option)
                                                                                                                                                      Earth Terminal
                                                                                                                                                                                                                                              231 (8-3/8’’)
                                                                                                                                                                     Side Vent
                                                                                                                                                                       (option)
                                            (5/16’’)
                                                                                                                                                                                                                                                              Sensor
                                               8
                                                                                                                                                                                                                                  (1-5/8’’)
                                                                                                                                                                                                                                                              Unit
                                                                                                                                                                                                                                    41.3
                                                                                                   E
                                                                                                                                                                                                                        Pressure Connection
                                                                                                                                            Pressure Connection
                      ø7                                                                                                                                                                                                (High Pressure Side)
                                                                                                                                             (Low Pressure Side)
                     (1/4’’)                                                   D
                 See Table 1                                            See Table 1
54 (2’’)
70 (2-3/4’’)
                                                                                                                                                                                                                                    Local
                                                                                                                                                                                                                                    Indicator
These Barton products are represented in your area by:                                 Sales Offices