A B C D E F G A B C D E F G A B C D E F G A B C D E F G

01 E L E C T R I C A L N O T E S 4.00m
5.65m

1.659m
1.907m
4.00m
5.65m

1.659m
1.907m

4.00m
5.65m

1.659m
1.907m

4.00m
5.65m

1.659m
1.907m

E 01 NOT TO SCALE
2.175m 1.825m .708m .951m 1.102m .804m 2.175m 1.825m .708m .951m 1.102m .804m 2.175m 1.825m .708m .951m 1.102m .804m 2.175m 1.825m .708m .951m 1.102m .804m
.875m 3.125m .875m 3.125m
LOT 51 BLK. 18, PCS-04-033217 LOT 51 BLK. 18, PCS-04-033217 LOT 51 BLK. 18, PCS-04-033217 LOT 51 BLK. 18, PCS-04-033217
1. ALL ELECTRICAL WORKS SHALL BE DONE IN ACCORDANCE PROPOSED FIREWALL EXTENSION
WITH THE PROVISION OF THE LATEST EDITION OF THE PHILIPPINE 1
PROPOSED FIREWALL
1 1
PROPOSED FIREWALL
1
PROPOSED FIREWALL EXTENSION

EXISTING FIREWALL 6" CHB


R

EXISTING FIREWALL 6" CHB

EXISTING FIREWALL 6" CHB

EXISTING FIREWALL 6" CHB


ELECTRICAL CODE (PEC, THE RULES AND REGULATIONS OF

1.50m
ROOF-02

1.50m

1.50m

1.50m
KITCHEN ROOF-02
LOCAL AND NATIONAL AUTHORITIES CONCERNED WITH PROPOSED ROOF LINE PB ROOF LINE
T&B c T&B 03 KITCHEN
ENFORCEMENT OF RULES AND REGULATIONS OF LOCAL UTILITY EXISTING EXISTING PROPOSED
PB
COMPANY. 2 S2de 2 01
01
2
PB
04
2
01 d g f 01 01
S1c

1.50m
RF PB

1.50m

1.50m

1.50m
02
2. THE SERVICE VOLTAGE TO THE BUILDING SHALL BE SINGLE PHASE, SERVICE
PROPOSED
SERVICE
PROPOSED
02
THREE WIRE 230 VOLTS, 60 HERTZ SYSTEM. 02 DINING
03
02 DINING
PB
02
03 AREA 03 AREA02 03
3

STAIRWELL
EXISTING 04 EXISTING
3 3 3

STAIRWELL
04 04 04
e 05

STAIRWELL

STAIRWELL
3. THE INSTALLATION SHALL BE DONE AS FOLLOWS : 05
06
b b
S1b 06
05
06
05
06
PB

5.00m
a. INTERMEDIATE METALLIC CONDUIT (IMC) ----- POWER SERVICE 07 BEDROOM-01

5.00m

5.00m

5.00m
07 01 07 WP 07 BEDROOM-01
ENTRANCE FEEDERS 4 08
a a
4 08
09
PROPOSED
08 4 08 PROPOSED
09 09 09

3.50m
b. POLYVINYL CHLORIDE (PVC) ----- LIGHTING, POWER BRANCH 10

3.50m

3.50m

3.50m
10 10 10
11
11 g f 11
CIRCUITS, AND AUXILIARY LAYOUT. 12
LIVING 12
12
LIVING
12

L
AREA AREA

WAL
ALL

ALL

L
13
EXISTING EXISTING

WAL
11.50m
13 S2fg 13 13

11.50m

11.50m

11.50m
EXISTING LIGHT AND

CE W

CE W
NCE
4. ALL WIRES TO BE USED SHALL BE COPPER AND POWER PANEL BOARD

NCE
LOCATED AT ENTRYWAY PB PB

FEN

FEN
FE
THERMOPLASTIC HEAT INSULATED TYPE "THWN" UNLESS NOTED a a

D FE
ENTRY ENTRY

SED
S1a

D
OTHERWISE SPECIFIED. 5

O SE

O SE

O SE
5 5 5

PO
.80m
ROP

ROP

ROP
PRO

.80m
P

P
5. ALL MATERIALS TO BE USED SHALL BE BRAND NEW AND OF THE EXISTING OUTLETS ARE ROOF LINE CORNER
CORNER CORNER CORNER

2.55m

2.55m
ROOF LINE
APPROVED TYPE FOR THE LOCATION AND PURPOSED INTENDED. NOT INCLUDED IN THE
IMPROVEMENT OF LAWN LAWN LAWN LAWN
CIRCUITS LAYOUT BELOW
EXISTING EXISTING BELOW

6. THE MINIMUM SIZE OF WIRE AND CONDUIT TO BE USED SHALL BE 3.5


GARAGE

5.00m

PROPOSED FENCE WALL


mm THHN AND 20 MM DIA. RESPECTIVELY. GARAGE

5.00m

5.00m

5.00m
PROPOSED FENCE WALL

PROPOSED FENCE WALL

PROPOSED FENCE WALL


6
GARAGE
AREA
6 AREA
BELOW 6
GARAGE
AREA 6 AREA
BELOW
EXISTING EXISTING
7. WHENEVER NECESSARY PULL BOX SHALL BE PROVIDED EVEN NOT
INDICATED IN THE PLAN.

8. BRANCH CIRCUIT HOMERUNS SHALL NOT BE COMBINED IN THE SAME


RACEWAY AND RACEWAY FOR AUXILIARY LINES SHALL NOT CONTAINS
POWER LINES. 7 7 7 7
POWER POWER
SOURCE; 230 V SOURCE; 230 V
INTERNET INTERNET
9. MOUNTING HEIGHTS SHALL BE AS FOLLOWS : S.E. S.E.

a. 0.30m ABOVE FLOOR FINISH ----- C.O. OUTLET & AUX. PROPOSED RENOVATION PROPOSED RENOVATION PROPOSED RENOVATION PROPOSED RENOVATION
OUTLET
b. 1.40m ABOVE FLOOR FINISH ----- LIGHT CONTROL
GROUND FLOOR SECOND FLOOR GROUND FLOOR SECOND FLOOR
SWITCH 02 L I G H T I N G L A Y O U T 03 L I G H T I N G L A Y O U T 04 P O W E R L A Y O U T 05 P O W E R L A Y O U T
c. 1.70m ABOVE FLOOR FINISH @ CENTER ----- PANEL BOARDS
E 01 SCALE: 1:100MTS. E 01 SCALE: 1:100MTS. E 01 SCALE: 1:100MTS. E 01 SCALE: 1:100MTS.
d. ALL OTHER HEIGHTS ----- VERIFY TO THE
ARCHITECT
PANEL: MDP PANELBOARD SPECIFICATIONS: BREAKER: MAIN:
10. ALL SERVICE ENTRANCE EQUIPMENTS SUCH AS PANEL BOARD SCHEDULE OF LOADS MAIN: 2 POLE, BOLT-ON TYPE, 3-WIRE I = 5820 / 230 + 25% (8.00) = 27.30 A USE: 2- 14.00 SQ. MM. THWN & 1-8.00 SQ. MM. THWN IN
SHALL BE PROPERLY GROUNDED IN ACCORDANCE WITH THE BRANCHES: 2 POLE, BOLT-ON TYPE BKR = 27.30 X 1.25 = 34.12 A 25 MM DIA. IMC ( 27.30/60A)
MOUNTING: NEMA 2, WALL MOUNTED WITH SPLASHED OF GRAY PAINT USE 2P, 60AT MAIN: 22KAIC MAIN: 60AT, 2PCB, 230V, B.O, I.T
PROVISION OF THE PHILIPPINE ELECTRICAL CODE.

11. THERE SHALL ONLY BE ONE SERVICE ENTRANCE DROP FOR THE
BUILDING. DESCRIPTION OF LOADS SWITCHES LOAD IN AMPERES BREAKER SPECIFICATIONS WIRE SCHEDULE
CKT.
NO.
SERVICE FIXTURES LO. CO. VA. VOLT S1 S2 S3 S4 S3W AB BC AC ABC AT AF POLE KAIC SERVICE WR. GROUND WIRE TYPE COLOR
DROP KW/HR
M
PB
01 LIGHTING OUTLET @ G/F AND 2/F 13 1300 230 05 5.56A 15 60 2 5 2-5.5 mm^2 2.0 sqmm THWN R+Y+G

METER PB
02 DUPLEX OUTLET @ G/F AND 2/F 04 720 230 3.13A 20 60 2 5 2-5.5 mm^2 2.0 sqmm THWN R+Y+G
PB
03 KITCHEN RANGE OUTLET 01 3000 230 3.04A 30 60 2 5 2-5.5 mm^2 2.0 sqmm THWN R+Y+G
PB
04 REFRIGERATOR OUTLET 01 800 230 3.47A 30 60 2 5 2-5.5 mm^2 2.0 sqmm THWN R+Y+G

MAIN 13 06 5820 230 15.2 A 30 60 2 5

"PB" PROPOSED RENOVATION

MAIN: 60AT, 2PCB, 06 S C H E D U L E O F L O A D S


15AT 20AT 230V, B.O, I.T E 01 NOT TO SCALE

CKT 1 CKT 2
30AT 30AT
REFRIGIRATOR CENTER LIGHT WALL LAMP
CKT 3 CKT 4 CO
CONVENIENCE OUTLET REF
CONVENIENCE OUTLET Sa
WEATHER PROOF SINGLE POLE SWITCH
CONVENIENCE OUTLET CT COUNTERTOP PINLIGHT
WP
CONVENIENCE OUTLET
T EF EXHAUST FAN
TELEPHONE OUTLET
L
LAN OUTLET
GROUND APPLICABLE
07 E L E C T R I C A L S Y M B O L S
E 01 NOT TO SCALE

DETAIL OF
08 P A N E L B O A R D
E 01 NOT TO SCALE

OFFICE OF: REPUBLIC ACT 545: SEC.25 ELECTRICAL ENGINEER: PROJECT TITLE: SHEET CONTENTS: OWNERS' NAME:

E01
WOODTOWN RESIDENCES
CONSTRUCTIFY BUILDERS INC. RENOVATION & EXTENSION Ms. MA. KARINA P. DIAZ
AS SHOWN
3RD FLOOR, UNIT K RAMOS BUILDING SINGLE-ATTACHED UNIT
BARANGAY SAMPALOC I,DASMARINAS CAVITE
DASMARINAS CAVITE, LANGKAAN 1
BLK 18 LOT 54, PHASE 03 BACOOR, CAVITE 4102

You might also like