KCS-MD600 Frequency Inverter
Main Features:
1. V/F control, senseless vector control and torque control are available;
2. 16 steps speed can be preset;
3. Programmable input and output;
4. No failure at sudden power off;
5. High starting torque (180% at 0.5HZ);
6. Motor short circuit protection,phase failure protection, over current protection, low voltage
protection, over heat protection, over load protection are available;
7. Compact design, which can save space in installation and system integration.
Specification:
Input voltage 220V+/-15% single phase 50/60Hz
Output voltage 220-380V+/-15% three phase 0~650Hz
Max. output frequency 0~650Hz
Carrier wave frequency 0.5kHz-16kHz, which will be auto adjusted according to carrier.
Control Mode RS485 communication interface is optional, adopt Modbus-RTU communication mode.
Starting Torque 0.5Hz/180%(SVC) ;
Speed adjusting range 1:200 ( SVC ) 1:1000(FVC) 1:50(V/F)
Torque control accuracy +/-5%
Overload Capability 150% rated current 60s, 180% rated current 3s.
Torque boost automatic torque boost,manual torque boost 0.1%~30.0% .
Three types are available:liner; Multi-point type; N times square ( 1.2 times square, 1.4
V/F curve
times square ,1.6 times square ,1.8 times square,2 times square ) .
DC brake DC brake frequency:0.00Hz~Max. frequency; Braking time: 0.0s-36.0s; Braking current:
0.0%-100.0%.
JOG control JOG frequency range:0.00Hz-50.00Hz; JOG ACC./DCC time 0.0s-6500.0s.
Multi step speed control 16 steps speed can be set.
In built PID can realize close loop process control for pressure, temperature, flow etc.
Automatic voltage can output constant voltage even grid voltage fluctuates.
regulation
safety detection to Safety detection to Peripherals when power on(such as grounding, shortcut etc.)
Peripherals
Textile swing control Triangular wave frequency control function
Timing control setting range 0H-65535H
Run/Stop command keypad giving,terminals giving,RS485 giving.
Frequency source digital giving, analog voltage giving, analog current giving, impulse giving, RS485 giving.
Five digital inputs,one of which can be used as high speed impulse input, the Max. Frequency
can reach 100kHz.
Input terminals
Source PNP or NPN input.
Two analog inputs.
One high speed impulse output (which can be set into open circuit collector), 0kHz~100kHz
square wave output;
one digital output;
Output terminals
one Relay output;
one analog output,0mA-20mA or 0v-10V selectable.
Protection function motor shortcut detection,input output phase lost protection, over current protection, over
voltage protection, low voltage protection, over heat protection, over load protection.
running environment indoor avoid sunlight, avoid dust、erosion gas、flammable gas, oil mist、steam vapor、water
drop、salt etc.
altitude Under 1000m.
Environmental -10C ~ +40 C. Deration above 40C
Temperature
Humidity under 95%RH, no water condensation
vibration under 5.9m/s(0.6g)
storage temperature -20℃ ~ +60℃