Part    : 4 - AA3
No.     :
     OTIS                             Field Component Manual
                                                                                                GCA 26800H2 VIIIc
                                                                                    Vintage : 01 / 1
Worldwide Engineering
                                                                                    Page    : 1/8
                                                 Software Data                      Date    : 24-NOV-2000
Engineering Center
      Berlin                                 OVF20V (MCB)                           D1      : 24-NOV-2000
                                    Software Baseline Release Document              SCN     : GAA 30330 AAC
                                      OVF20V (MCB)
                                      Software Baseline Release Document
             Authorization Date D1 :                24-Nov-2000
             Running on PCB :                       GCA 26800 H2
             Software Version :                     GAA 30330 AAC
             Document Revision:
                     Date             SCN               Author             Comment
                 24-Feb-1999     GAA 30330 AAA       Blechschmidt      Original document
                 24-Nov-2000     GAA 30330 AAC       Blechschmidt               "
Copyright 2000, OTIS GmbH Berlin
No part of this document may be copied or reproduced in any form or by any means without the prior written
consent of OTIS GmbH.
                                                                    Part    : 4 - AA3
                                                                    No.     :
    OTIS                       Field Component Manual
                                                                                GCA 26800H2 VIIIc
                                                                    Vintage : 01 / 1
Worldwide Engineering
                                                                    Page    : 2/8
                                          Software Data             Date    : 24-NOV-2000
Engineering Center
      Berlin                            OVF20V (MCB)                D1      : 24-NOV-2000
                             Software Baseline Release Document     SCN     : GAA 30330 AAC
QUALITY APPROVALS
Function                  Name                               Date
Originator
                          (G. Blechschmidt)
Software Responsible
                          (G. Blechschmidt)
Software Administrator
                          (Dr. H. K. Spielbauer)
Engineering Responsible
                          (H. Horbrügger)
Product Support
                          (D. Schenkel)
Product Qualification
                          (G. Stricker)
Quality Assurance
                          (R. Müller)
Field Operation Dep.
                          (U. Lassen)
This document was approved by the signers and authorized by the PEGASUS
administrator.
                                                                  Part    : 4 - AA3
                                                                  No.     :
    OTIS                      Field Component Manual
                                                                              GCA 26800H2 VIIIc
                                                                  Vintage : 01 / 1
Worldwide Engineering
                                                                  Page    : 3/8
                                       Software Data              Date    : 24-NOV-2000
Engineering Center
      Berlin                        OVF20V (MCB)                  D1      : 24-NOV-2000
                             Software Baseline Release Document   SCN     : GAA 30330 AAC
SOFTWARE CONFIGURATION NUMBER:
GAA 30330 AAC
CONFIGURATION IDENTIFICATION:
Worldwide baseline software for MCB_II GCA 26800 H2
(in conjunction with VCB board GAA 26800 AS1 and software GAA 30167 AAC).
ENGINEERING AUTHORIZATION DATE (D1):
24-Nov-2000
FIRST DELIVERY FROM COMPONENT FACTORY (D3):
22-Dec-2000
PARENT BASELINE NUMBER:
GAA 30330 AAA
Note: a version GAA 30330 AAB does not exist.
PRODUCT CHANGES:
Brake switch supervising / monitoring (BSW) has been added.
                                                                             Part    : 4 - AA3
                                                                             No.     :
     OTIS                            Field Component Manual
                                                                                         GCA 26800H2 VIIIc
                                                                             Vintage : 01 / 1
Worldwide Engineering
                                                                             Page    : 4/8
                                                Software Data                Date    : 24-NOV-2000
Engineering Center
      Berlin                                OVF20V (MCB)                     D1      : 24-NOV-2000
                                   Software Baseline Release Document        SCN     : GAA 30330 AAC
DELIVERABLE MEDIA:
Download over network or programmed device (PROM or EPROM).
Device data:
     Download Directory                : MECSPUBLIC$ROOT:[MECSPUBLIC]
     Number of required devices        :                             1
     OTIS Blank Part Number,
                             PROM (OTP):                  GAA 616 HK 1
                                 FLASH:                    GO 616 BS 4
     Blank Label Part Number           :                 GAA 102 AFL 4
     Programmed device order number    :              GAA 30330 AAC 1
Device labeling data :
                     COPR. 2000 OTIS
                     GAA 30330 AAC 1
                     Z2       #5932#
                     MCB_II
Note: Labels are shown in scale 2:1 from a recommened original size.
Programming instructions:
     Hex Filename                                 :                    GAA30330AAC.HEX
     Start Address                                :                                0000
     Processor                                    :                           80C196KB
     Checksum                                     :                           5932 (hex)
     Set Length                                   :                                    1
     Word Length (bits)                           :                                    8
     Fill unused bytes with                       :                             FF (hex)
The above configuration has been tested on a CELECTRONIC "promicron 1000"
programmer with module 1500.
The programmer has to be set to extended INTEL hex-format.
                                                                        Part      : 4 - AA3
                                                                        No.       :
       OTIS                      Field Component Manual
                                                                                      GCA 26800H2 VIIIc
                                                                        Vintage : 01 / 1
Worldwide Engineering
                                                                        Page      : 5/8
                                           Software Data                Date      : 24-NOV-2000
Engineering Center
      Berlin                            OVF20V (MCB)                    D1        : 24-NOV-2000
                                Software Baseline Release Document      SCN       : GAA 30330 AAC
FACTORY STOCK HANDLING OF DEVICES PROGRAMMED WITH PREVIOUS SW
VERSIONS:
The new SW version must be used in factory immediately after release.
Deviced pre-programmed with previous SW versions have not to be used any longer.
DEPENDENCIES:
This software runs only on MCB II board version GCA 26800 H2 (or higher)
together with VCB board version GAA 26800 AS1 (or higher).
Additional dependencies:
 • Controllers (modernization and new sales) MCS 220, MCS 220 M only with learn run.
   For learn run the LCB II software GAA30082BAG or higher is required.
 • This software is released for operation with OVF20-1 / 22kW packages only.
 • This software is released for operation with the following motor types only:
   -   ATB-LOHER LUGA 200LB06
   -   REIVAJ TAA20000-G5 with 18ATF machine
 • This software cannot be operated in "Power-Off"-mode (parameter "P-OFF-D" on
   LCB-II must be set to 255).
 • This software cannot be operated on MCB II board version ...H1 (w/o VCB adaption) !
 • Feature LNS-E (LNS information via motor slip & Vdc measurement) is not supported.
OPEN ITEMS:
 • Clearing of error logging is not possible while fan is running.
 • This software cannot be operated in "Power-Off"-mode (parameter "P-OFF-D" on
   LCB-II must be set to 255).
 • VCB - Prom checksum test is not implemented.
                                                                        Part    : 4 - AA3
                                                                        No.     :
    OTIS                         Field Component Manual
                                                                                    GCA 26800H2 VIIIc
                                                                        Vintage : 01 / 1
Worldwide Engineering
                                                                        Page    : 6/8
                                             Software Data              Date    : 24-NOV-2000
Engineering Center
      Berlin                            OVF20V (MCB)                    D1      : 24-NOV-2000
                                Software Baseline Release Document      SCN     : GAA 30330 AAC
REFERENCE DOCUMENTS:
Field Component Manual :
     Field Component Manual                  :     GCA 26800 H2
     (Contents and Revision)
           Guide Lines                       :     GCA 26800 H2 I
           Start Up Routine                  :     GCA 26800 H2 II
           Service Handling                  :     GCA 26800 H2 III
           Service Tool User’s Guide         :     GCA 26800 H2 IV
           Software Data:
           List of Installation Parameters   :     GCA 26800 H2 VIIIa
           Baseline Release Document         :     GCA 26800 H2 VIIIc
Engineering Documents:
     Basic Data OVF20                        :     BD_O20_3.DOC
     Basic Data MCB II                       :     BD_MCB.DOC
                                                                              Part      : 4 - AA3
                                                                              No.       :
       OTIS                           Field Component Manual
                                                                                             GCA 26800H2 VIIIc
                                                                              Vintage : 01 / 1
Worldwide Engineering
                                                                              Page      : 7/8
                                               Software Data                  Date      : 24-NOV-2000
Engineering Center
      Berlin                                 OVF20V (MCB)                     D1        : 24-NOV-2000
                                    Software Baseline Release Document        SCN       : GAA 30330 AAC
QUALIFICATION AND VERIFICATION PROCEDURE:
The qualification and verification has been done with software G1130330AAC on the
following jobsites:
      Unit-Nr.       System        Duty            Motor         Machine              Remarks
  47NG9792          MCS220M        800kg      Type 902: REIVAJ   13VTR        BSW2: Brake switches
(OEC-B build.1a)                  x 1.6m/s    TBA422H1, 8.5kW                  simulated with relays
  47NF9529          MCS220M        2000kg      Type 2: REIVAJ    18ATF        BSW1: Brake switches
(OEC-B build.2)                   x 1.6m/s   TAA20000-G5, 26kW                 installed on machine
     47KK6487       MCS220M        2500kg    Type 1: ATB-Loher    SASSI
    (Halberstadt)                 x 1.0m/s     LUGA, 22kW
The test results are:
      Unit-Nr.      Operating     Number         Number of       Number of           Number of
                      Days        of Runs        Blockages       Recoveries         other Events
  47NG9792              16         20725              0                  0                  7
(OEC-B build.1a)
  47NF9529              16          4122              0                  0                  1
(OEC-B build.2)
     47KK6487           13          5648              0                  0                  12
    (Halberstadt)
Qualification of factory tests:
•    Package test is currently performed with SW version G2230330AAB because of motor
     and current control adaption problems (which will be solved with version
     GAA30330AAD).
•    Run-in test has been verified with software version G1130330AAC.
•    Controller test has been verified with SW version GAA30330AAA.
     This test is currently performed with manually parameter setting. Only the changed
     parameter locations have to be considered when using the GAA30330AAC software
     (see Baseline Modification report).
                                                                      Part    : 4 - AA3
                                                                      No.     :
     OTIS                       Field Component Manual
                                                                                  GCA 26800H2 VIIIc
                                                                      Vintage : 01 / 1
Worldwide Engineering
                                                                      Page    : 8/8
                                         Software Data                Date    : 24-NOV-2000
Engineering Center
      Berlin                          OVF20V (MCB)                    D1      : 24-NOV-2000
                               Software Baseline Release Document     SCN     : GAA 30330 AAC
BASELINE MODIFICATION REPORT
Enhancements:
•   Brake switch supervising / monitoring implemented. The MCB input P1.3 is used a
    brake switch input (BSW). The following brake switch configurations are supported and
    can be configured by the parameter "BrakeSWtype":
    • Type 1: 2 NC-switches wired in parallel
    • Type 2: 2 Make&break switches with additional SW- or BR - contact.
•   New motor type implemented: REIVAJ TAA20000-G5 with 18ATF machine. Parameter
    "Motor type" must be set to 2.
Perfections:
•   Parameter "SYS Inert" has been moved within the CONTRACT parameter menu. The
    new location is now immediately after the "Motor type" parameter.
    This has been done to have unique parameter sequences in all MCB_II&VCB software
    baselines (e.g. GeN2).