Pressed
Pressed
                                                                                                                                                                                              1
80            80 SERIES
SERIES        Modular timers 16 A
    2
                             80 SERIES                                                                                                                       80
                             Modular Solid State timer (SST) 1 A                                                                                             SERIES
                                                                                                                                                              3
80           80 SERIES
SERIES       Modular timers 6 - 8 A
    4
                             80 SERIES                                                                                                                                                      80
                             Modular timers 1 - 6 - 8 - 16 A                                                                                                                                SERIES
                             Ordering information
                             Example: 80 series, modular timers, 1 CO (SPDT) - 16 A, supply rated at (12…240)V AC/DC.
                                                             8 0 . 0                   1 . 0 . 2 4 0 . 0                                       0       0           0
                              Series                                                                                           Versions
                              Type                                                                                             0 = Standard
                              0 = Multi-function (AI, DI, SW, BE, CE, DE)                                                     Supply voltage
                              1 = On-delay (AI)                                                                               240 = (12…240)V AC/DC (80.01, 80.91)
                              2 = Interval (DI)                                                                               240 = (24…240)V AC/DC (80.11, 80.21, 80.41, 80.71, 80.82)
                              4 = Off-delay with control signal (BE)                                                          240 = (24…240)V AC, (24…220)V DC (80.61)
                              6 = Power off-delay (True off-delay) (BI)                                                       Supply version
                              7 = Multi-function with solid state output                                                      0 = AC (50/60 Hz)/DC
                                   (AI, DI, SW, BE, CE, DE)
                                                                                                                               No. of poles
                              8 = Star-delta (SD)
                                                                                                                               1 = 1 CO (SPDT)
                              9 = Asymmetrical flasher (LI, LE)
                                                                                                                               1 = 1 NO (SPST-NO), type 80.71 only
                                                                                                                               2 = 2 NO (DPST-NO), type 80.82 only
                              Technical data
                             Insulation
                             Dielectric strength                                                                 80.01/11/21/41/82/91                      80.61             80.71
                                                                  between input and output circuit       V AC   4000                                      2500              2500
                                                                  between open contacts                  V AC   1000                                      1000              —
                             Insulation (1.2/50 µs) between input and output                               kV   6                                         4                 4
                             EMC specifications
                             Type of test                                                                        Reference standard        80.01/11/21/41/61/71/91           80.82
                             Electrostatic discharge                               contact discharge             EN 61000-4-2              4 kV                              4 kV
                                                                                   air discharge                 EN 61000-4-2              8 kV                              8 kV
                             Radio-frequency electromagnetic field (80 ÷ 1000 MHz)                               EN 61000-4-3              10 V/m                            10 V/m
                             Fast transients (burst) (5-50 ns, 5 kHz) on Supply terminals                        EN 61000-4-4              4 kV                              4 kV
                             Surges (1.2/50 µs) on Supply terminals                common mode                   EN 61000-4-5              4 kV                              4 kV
                                                                                   differential mode             EN 61000-4-5              4 kV                              4 kV
                                      on start terminal (B1)                       common mode                   EN 61000-4-5              4 kV                              4 kV
                                                                                   differential mode
                             Radio-frequency common mode (0.15 ÷ 80 MHz) on Supply terminals
                                                                                                                 EN 61000-4-5
                                                                                                                 EN 61000-4-6
                                                                                                                                           4 kV
                                                                                                                                           10 V
                                                                                                                                                                             4 kV
                                                                                                                                                                             10 V
                                                                                                                                                                                                 H
                             Radiated and conducted emission                                                     EN 55022                  class B                           class A
                             Other data
                             Current absorption on signal control (B1)                                           < 1 mA
                             Power lost to the environment                         without contact current W    1.4
                                                                                   with rated current       W   3.2
                                  Screw torque                                                             Nm 0.8
                             Max. wire size                                                                   solid cable                                  stranded cable
                                                                                                         mm2 1 x 6 / 2 x 4                                1 x 4 / 2 x 2.5
                                                                                                         AWG 1 x 10 / 2 x 12                              1 x 12 / 2 x 14
                              Accessories
                                                          Sheet of marker tags, for types 80.82, plastic, 24 tags, 9 x 17 mm                               020.24
020.24
                                                          Sheet of marker tags (CEMBRE'S Thermal transfer printers) for relays types
                                                                                                                                                           060.48
                                                          80.01/11/21/41/61/71 (48 tags), 6 x 12 mm
XI-2016, www.findernet.com
060.48
                                                                                                                                                                                             5
80           80 SERIES
SERIES       Modular timers 1 - 6 - 8 - 16 A
    Outline drawings
    80.01                                      80.11
    Screw terminal                             Screw terminal
    80.21                                      80.41
    Screw terminal                             Screw terminal
    80.91                                      80.71
    Screw terminal                             Screw terminal
    80.61                                      80.82
    Screw terminal                             Screw terminal
                                                                XI-2016, www.findernet.com
    6
                             80 SERIES                                                                                                                                                       80
                             Modular timers 1 - 6 - 8 - 16 A                                                                                                                                 SERIES
                             Functions
                                  U = Supply voltage                                                                              NO output                         Contacts
                                                                             LED*                         Supply voltage
                                                                                                                                   contact                Open                 Closed
                                   S = Signal switch
                                                                                                                OFF                     Open              15 - 18              15 - 16
                                      = Output contact
                                                                                                                ON                      Open              15 - 18              15 - 16
                                                                                                                                    Open
                                                                                                                ON                                        15 - 18              15 - 16
                                                                                                                              (Timing in Progress)
ON Closed 15 - 16 15 - 18
                                                         * The LED on type 80.61 is illuminated only when the supply voltage is applied to the timer; during the timing period the LED
                                                            is not illuminated.
                                                                                                                          (DI) Interval.
                                                                                                                          Apply power to timer. Output contacts transfer immediately.
                                               80.01                                                                      After the preset time has elapsed, contacts reset.
80.71
• Possible to control an external load, such as another relay coil or timer, connected to the control signal terminal B1.
                                                         **	A voltage other than the supply voltage can be applied to the command Start (B1), example:
                                                             A1 - A2 = 230 V AC
                                                             B1 - A2 = 12 V DC
                                                                                                                                                                                              7
80             80 SERIES
SERIES         Modular timers 6 - 8 - 16 A
    Functions
    Wiring diagram
    Without control signal   Type                                                            (AI) On-delay.
                             80.11                                                           Apply power to timer. Output contacts transfer after preset
                                                                                             time has elapsed. Reset occurs when power is removed.
        80.11/21/61
                             80.61                                                           (BI) Power off-delay (True off-delay).
                                                                                             Apply power to timer (minimum 500 ms). Output contacts
                                                                                             transfer immediately. Removal of power initiates the preset
                                                                                             delay, after which time the output contacts reset.
           80.41
    Without control signal   80.91                                                           (LI) Asymmetrical flasher (starting pulse on).
                                                                                             Apply power to timer. Output contacts transfer immediately
                                                                                             and cycle between ON and OFF for as long as power is applied.
                                                                                             The ON (T1) and OFF (T2) times are independently adjustable.
H
80.91
• Possible to control an external load, such as another relay coil or timer, connected to the control signal terminal B1.
                             ** A voltage other than the supply voltage can be applied to the command Start (B1), example:
                                 A1 - A2 = 230 V AC
                                 B1 - A2 = 12 V DC