26230, 80107 Inline
3/2, 5/2 and 5/3 directional control valves
Actuation: electromagnetic
Indirectly controlled soft seal spool valves
Port size: G 1/4, G 1/2
Straight-through flow, high Cv-factor
Compact design
Maintenance-free
Easy to service
Easily interchangeable solenoid system
Standard manual override
The valves and solenoids are ATEX approved
Technical data Ordering information
Operating medium: See page 2
Solenoid valve for filtered, lubricated *1)
or non-lubricated air Further versions
Operation: NPT
Solenoid, indirectly controlled
Flow direction: Accessories data sheet
Fixed Manifold system 7503364
Mounting position: Connectors N/UK 7.7.002
Optional
Nominal size: 3/2
6 and 12 mm 2 2
Port size: 14 12 14 12
G 1/4, G 1/2
1 3 3 1
Electrical connection:
Connector interface to DIN EN 175301-803 2
form A and B 14 12
Operating pressure: 3 1
1 to 10 bar
Temperature: 5/2
-10 ... 50°C 24 42
Please consult our technical service for use below +2°C. If installed
in the open protect all connections against the penetration of moisture! 14 12 14 12
Material: 3 15 5 13
Housing: Aluminium
Pilot flange: Plastic 5/3
Seat seal: NBR (Perbunan) 42 42
*1) Oil recommendation: Shell Hydrol DO 32, Esso Febis (as of July 1992)
or comparable oils with DVI values < 8 (DIN 53521) and ISO viscosity class 14 12 14 12
32-46 (DIN 51519).
5 13 5 13
42
14 12
5 13
11/05 Our policy is one of continued research and development. We therefore reserve
the right to amend, without notice, the specifications given in this document.
N/UK 5.4.336.01
26230, 80107 Inline
General information
Symbol Type* Function Port size Nominal Operating pressure (bar) Flow Power Weight Dimensions
size Min. Max. (l/min) drawn (W) (kg) Nr.
2 8010750 *2) 3/2 mono NC G 1/4 6 1,0 10 *3) 1200 <5 0,4 1
14 12
8010850 *2) 3/2 mono NC G 1/2 12 1,5 10 *3) 3000 <5 0,7 2
1 3
2 8012750 *2) 3/2 mono NO G 1/4 6 1,0 10 *3) 1200 <5 0,4 1
14 12
8012850 *2) 3/2 mono NO G 1/2 12 1,5 10 *3) 3000 <5 0,7 2
3 1
2 8011750 3/2 bi G 1/4 6 1,0 10 1200 <5 0,77 3
14 12
3 1
24 2623000 *2) 5/2 mono G 1/4 6 1 10 *3) 1200 <5 0,4 5
14 12
2623500 *2) 5/2 mono G 1/2 12 2 10 *3) 3000 <5 0,7 6
3 15
42 2623100 5/2 bi G 1/4 6 1 10 1200 <5 0,4 7
14 12
2623600 5/2 bi G 1/2 12 2 10 3000 <5 0,7 8
5 13
42
14 12 2623200 5/3 G 1/4 6 3 10 900 <5 1,0 9
2623700 5/3 G 1/2 12 2,5 10 2200 <5 1,6 10
5 13
42 2623300 5/3 G 1/4 6 3 10 900 <5 1,0 9
14 12
2623800 5/3 G 1/2 12 2,5 10 2200 <5 1,6 10
5 13
42 2623400 5/3 G 1/4 6 3 10 900 <5 1,0 9
14 12
5 13
2 8010751 *2) 3/2 mono NC G 1/4 6 2 8 *3) 1200 <2 0,4 1
14 12
8010851 *2) 3/2 mono NC G 1/2 12 2 8 *3) 3000 <2 0,7 2
1 3
24 2623001 *2) 5/2 mono G 1/4 6 2 8 *3) 1200 <2 0,4 5
14 12
2623501 *2) 5/2 mono G 1/2 12 2 8 *3) 3000 <2 0,7 6
3 15
42 2623101 5/2 bi G 1/4 6 2 8 1200 <2 0,4 7
14 12
2623601 5/2 bi G 1/2 12 2 8 3000 <2 0,7 8
5 13
All types with manual override
* When ordering please indicate solenoid, voltage and current type (frequency).
*2) Port 3 is not throttleable
*3) Stagnation pressure at R ≤ operating pressure -1 bar
Ordering information
3/2 directional control valve, connection G 1/4,
actuating solenoid 24 V DC, with connector DIN 43650 form B,
protection class IP65
Part No.: 8010750.3053.024.00
Warning
These products are intended for use in industrial compressed air sys- systems and to provide adequate safeguards to prevent personal
tems only. Do not use these products where pressures and tempera- injury or damage to equipment in the event of such failure.
tures can exceed those listed under ‘Technical Data’.
System designers must provide a warning to end users in the
Before using these products with fluids other than those specified, for
system instructional manual if protection against a failure mode
non-industrial applications, life-support systems, or other applications
cannot be adequately provided.
not within published specifications, consult NORGREN.
Through misuse, age, or malfunction, components used in fluid power System designers and end users are cautioned to review specific
systems can fail in various modes. The system designer is warned to warnings found in instruction sheets packed and shipped with these
consider the failure modes of all component parts used in fluid power products where applicable.
N/UK 5.4.336.02 Our policy is one of continued research and development. We therefore reserve
the right to amend, without notice, the specifications given in this document.
11/05
26230, 80107 Inline
Solenoid actuators
Type Power consumption Rated current at Protection class Temperatur e Weight Dimensions Circuit
24 V DC 230 V AC 24 V DC 230 V AC Fluid max. Ambient/fluid diagram
(W) (VA) (mA) (mA) (°C) (kg) No. No.
3052 4,8 8,5 – – IP 00 -40 ... +50 0,06 11 1
3050 1,7 4,3 – – without connector,
IP 65 with connector*
Form B *6)
3030 4,5 8,0 – – IP 00 -40 ... +50 0,09 12 1
3036 1,6 3,5 – – without connector,
IP 65 with connector*
Form A *6)
3062 2,7 – – – Cat. II2G, EEx m II T5 -20 ... +50 0,13 13 1
3 m cable *2)
3063 – 2,1 – – Cat. II2G, EEx m II T5 -20 ... +50 0,13 13 8
3 m cable *2)
3060 5,0 – – – Cat. II2G, EEx m II T4 -20 ... +50 0,13 13 1
3 m cable *2)
3061 – 5,0 – – Cat. II2G, EEx m II T4 -20 ... +50 0,13 13 8
3 m cable *2)
* Connector not supplied, Order No.: form A 0570275, form B 0680003, DIN EN 1753301-803
*2) Certificate of Conformity PTB No. 03 ATEX 2015 X
Valves and solenoids can only be combined if their electrical ratings correspond with each other (see table »General information«).
For valve with power consumption < 5 watt please use 4,8 or 4,5 watt solenoids.
For valve with power consumption < 2 watt please use 1,7 or 1,6 watt solenoids.
Standard voltages 24 V DC, 230 V AC. Further versions on request.
Accessories
Connectors
0570275 form A 0680003 form B
11/05 Our policy is one of continued research and development. We therefore reserve
the right to amend, without notice, the specifications given in this document.
N/UK 5.4.336.03
26230, 80107 Inline
Basic dimensions for valves
,
14
1
B
A 1
2
G
K
J
L
F
H
P R
E D S
C 1 Manual override
Dimensional A B C D E F G H J K L ØP R S
drawing No.
1 G 1/4 115,5 55 41 7 11 24 7,5 24,5 27 23 5,5 5 30
2 G 1/2 143,5 65 46 9,5 29 33 31,5 – 46 50 7 2,5 35
,
14
1
1
A
2
B
G
3
L
J
F
1
12
E D R
1 Manual override
C S
Dimensional A B C D E F G H J K L ØP R S
drawing No.
3 G 1/4 186,5 55 41 7 81,5 24 78 95 27 93,5 5,5 5 30
4 G 1/2 195,5 65 46 9,5 81 33 81 – 46 100,5 7 2,5 35
N/UK 5.4.336.04 Our policy is one of continued research and development. We therefore reserve
the right to amend, without notice, the specifications given in this document.
11/05
26230, 80107 Inline
Basic dimensions for valves
,
14
3
B
2
G
G
1
A
K
4
L
G
F
P
5
H
J
E D R
C S 1 Manual override
Dimensional A B C D E F G H J K L M ØP R S
drawing No.
5 G 1/4 139,5 55 40 7,5 35 24 – 5 – 67 12 7 5 30
6 G 1/2 171,5 65 46 9,5 59,5 33 30 16 46 60 13 7 3 35
to
14
1
3
2
G
1
B
4
L
G
5
F
1
H
12
E D R
D1 S 1 Manual override
C
Dimensional A B C D D1 E F G H K L M ØP R S
drawing No.
7 G 1/4 214,5 55 40 40 7,5 107,5 24 77,5 67 – 12 7 5 30
8 G 1/2 223,5 65 46 46 9,5 112 33 82,5 46 60 13 7 3 35
9 G 1/4 232,5 55 40 40 7,5 118 24 88 67 – 12 7 5 30
10 G 1/2 289 70 46 50 10 144,5 33 – 50 60 16,5 7 4 40
11/05 Our policy is one of continued research and development. We therefore reserve
the right to amend, without notice, the specifications given in this document.
N/UK 5.4.336.05
26230, 80107 Inline
Basic dimensions for solenoid operators
11 12
29 36
29,5
29,5
11 15
65 12 72 12
30
22
Ø9 Ø9
13
29
1 Solenoid actuators
4x90° turnable
29,5
22
~ 56
Circuit diagrams
N/UK 5.4.336.06 Our policy is one of continued research and development. We therefore reserve
the right to amend, without notice, the specifications given in this document.
11/05