iHFG Standard Components: International Health Facility Guidelines
iHFG Standard Components: International Health Facility Guidelines
ANMM ANAESTHETIC - MACHINE WITH ANAESTHETIC MONITOR PO/C POWER OUTLET - CLEANER'S
AV AUDIO VISUAL OUTLET PTZ PAN-TILT-ZOOM CAMERA
SERVCIE 4 x AV
AV/DC AUDIO VISUAL OUTLET - DIRECT CONNECTION PU/IN1 PUMP - INFUSION, SINGLE PENDANT - 4 x COM/2
BNR BENCH - RESINATE PU/IR PUMP - INFUSION, RAPID SURGICAL DROP 1 x O2
BRCCM BRACKET - CARDIAC MONITOR PU/S PUMP - SYRINGE (SPE/S) 1 x MA
BS1 BOWL STAND - SINGLE PU/SAM PUMP - SUCTION, ASPIRATOR, MOBILE 1x S
CARP CARDIAC PROTECTED PU/SAP PUMP - SUCTION, ASPIRATOR, PORTABLE 2 x SA (FOR DRILLS)
CBT/BFW CABINET - BLANKET/ FLUID WARMING RAG RETURN AIR GRILLE 1 x CO2 (OPTIONAL)
10 x PO/1I
CBT/SER CABINET - SERVER, OPERATING THEATRE INTEGRATION S SUCTION
1 x DCE
CBT/STO CABINET - STORAGE, OPERATING THEATRE INSTRUMENT SA SURGICAL AIR 1 x TA/DC (FOR SUPPLY UNIT BRAKES)
CHR/A CHAIR - ANAESTHETIST SAC STAFF ASSIST CALL
CMP COMPUTER SB SUCTION BOTTLE
L/O2M 1 x AV (MON/D)
COM/1 COMMUNICATION OUTLET - SINGLE SBC SUCTION BOTTLE CARRIER
(IN CEILING 1 x COM/2 (MON/D)
COM/2 COMMUNICATION OUTLET - DOUBLE SC SCAVENGE OUTLET OUTLETS) 1 x DCU/1
COM/DC COMMUNICATION OUTLET - DIRECT CONNECTION SK4 FLOOR VINYL COVED SKIRTING 1 x PO/2U (MON/D)
CONP/SR CONTROL PANEL - SURGICAL, RECESSED SME SMOKE EVACUATOR
DCE DIRECT CONNECTION - EMERGENCY POWER SUPPLY SPE/A SERVICES PENDANT - ANAESTHESIA L/O3CM2 2 x AV (MON/D & MON/TS)
DCU/1 DIRECT CONNECTION - UNINTERRUPTED POWER SUPPLY, SINGLE SPE/P SERVICES PENDANT - PERFUSSIONIST (IN CEILING 2 x COM/2 (MON/D & MON/TS)
DDG DISPENSER - DISPOSABLE GLOVES SPE/S SERVICES PENDANT - SURGICAL OUTLETS) 1 x DCU/1
DFP DOOR AND DOOR FRAME PROTECTION ST/O STOOL - OPERATING, MOBILE 2 x PO/2U (MON/D & MON/TS)
1 x COM/DC (IN LIGHT CAMERA)
DFR DEFIBRILLATOR T/A TROLLEY - ANAESTHETIC
EC EMERGENCY CALL T/AMD TROLLEY - AUTOMATED MEDICATION DISPENSING
ESU ELECTRO SURGICAL UNIT T/G TROLLEY - GOWNS CONP/SR 1 x DCU/1
1 x COM/DC
HHU HYPO-HYPERTHERMIA UNIT T/I TROLLEY - INSTRUMENT
IM/USU IMAGING - ULTRASOUND SCANNING UNIT T/R TROLLEY - RESUSCITATION, ADULT
IVS IV STAND - MOBILE TA/DC TOOL AIR - DIRECT CONNECTION MON/D 55" 2 x AV (1 PER MONITOR)
KB KICKBUCKET & STAND TB/MY TABLE - MAYO (BOTH) 2 x COM/2 (1 PER MONITOR)
2 x PO/2U (1 PER MONITOR)
L/CCD LIGHT - COLOUR CORRECTED, DIMMABLE TP/HH TELEPHONE - HANDSET, HANDSFREE
L/LA LIGHT - 'LASER IN USE' V1 VINYL FLOORING, STANDARD SLIP RESISTANT
MON/TS 1 x AV
L/O2M LIGHT - OPERATING, 2-ARM, 1 LIGHT / 1 MONITOR WPFSR WALL PAINT FINISH, SCRUB RESISTANT
(WALL MOUNTED 1 x COM/2
L/O3CM2 LIGHT - OPERATING, 3-ARM, 1 LIGHT WITH CAMERA / 2 MONITORS WV WALL VINYL FULLY RECESSED) 1 x PO/2U
LIND/S LINEN CARRIER - DIRTY, SINGLE
MA MEDICAL AIR
SERVICE 4 x AV (2 PER ARM) PTZ, OPTIONAL 1 x COM/DC
MON/C MONITOR - CARDIAC (IN CEILING 1 x DCU/1
PENDANT - 4 x COM/2 (2 PER ARM)
MON/D MONITOR - DISPLAY ANAESTHETIC 1 x O2 (ANAESTHESIA ARM) OUTLETS)
MON/TS MONITOR - TOUCH SCREEN DROP (SPE/A) 2 x O2 (PERFUSIONIST ARM)
N2O NITROUS OXIDE PERFUSSIONIST 2 x N2O (ANAESTHESIA ARM) NOTE:
DROP (SPE/P) 1 x MA (ANAESTHESIA ARM) RADIATION SHIELDING REQUIREMENTS TO BE PROVIDED BY A QUALIFIED
O2 OXYGEN
2 x MA (PERFUSIONIST ARM) RADIATION SHIELDING CONSULTANT
OPC ORDERLY/ PORTER CALL
OPS/R OBSERVATION PANEL WITH SLIDING PANEL - RADIATION SHIELDING 1 x S (ANAESTHESIA ARM) NOTE:
2 x S (PERFUSIONIST ARM) NUMBER OF REQUIRED SERVICES PER PENDANT TO BE ADJUSTED TO MEET
OPV OBSERVATION PANEL WITH INTEGRAL VENETIAN BLINDS
2 x SC (ANAESTHESIA ARM) PROJECT REQURIEMENTS BUT NOT TO BE LESS THAN THE NUMBERS SHOWN
OTA/M OPERATING TABLE - MOBILE, ELECTRIC 1 x CO2 (PERFUSIONIST ARM) - (OPTIONAL) HERE.
PC2 PLASTERBOARD CORNICE, FLUSHED COVED 1 x EC
PO/1-32A POWER OUTLET - SINGLE, 32 AMPS 1 x SAC NOTE:
PO/1I ISOLATED POWER SUPPLY - SINGLE 1 x OPC (OPTIONAL) WALL FINISH: FULL HEIGHT WALL VINYL OR EPOXY PAINT OR WPFSR.
20 x PO/1I (10 PER ARM) DOOR: LAMINATED DOOR PANEL WITH ENAMEL PAINT FINISH ON METAL DOOR
PO/2E POWER OUTLET - EMERGENCY, DOUBLE
1 x DCE FRAME
PO/2U UNINTERRUPTED POWER SUPPLY - DOUBLE
8400 1 x TA/DC (FOR SUPPLY UNIT BRAKES)
T/R
PU/SAP
T/G OPENING
BS1
CHR/A
DFR
T/A
900
TB/MY
IVS IVS T/AMD
PU/S PU/S PU/IR IM/USU BS1
PU/IN1 PU/IN1 CARDIAC/ECHO (OPTIONAL)
KB SERVICES
ZONE
SPE/P
900
CBT/STO MON/D
(OPTIONAL) MON/C KB
SPE/A (FULLY
BRCCM HEAT LUNG RECESSED,
BYPASS OPTIONAL)
MACHINE LIND/S
725 HEPA FILTER
T/I
IN CEILING
ANMM
1850
LIND/S
MON/D T/I
(FULLY
RECESSED, MON/TS
OPTIONAL) (FULLY
T/I RECESSED,
6850
CL OF ROOM OPTIONAL)
PUMP -
L/O2M L/O3CM2 INTRA-AORTIC
(OPTIONAL)
(OPTIONAL)
MON/TS MON/D
ST/O
AUTOMATED OTA/M
SUPPLY TP/HH
2200
STATION - ST/O
ESU , SME
MAIN UNIT MOUNTED ON
SUP/S SPE/S
COAGULATION
AUTOMATED UNIT - ACT
SERVICES
SUPPLY
STATION -
1550
55 m² CBT/SER
(OPTIONAL)
AUX UNIT 1 CARP FLOOR=V1
ZONE 4 2
3
LOW LEVEL RAG
SB SB
SBC
SB SB
1600MM CLEAR PU/SAM
HHU 1600MM CLEAR
OPENING OPENING
CL OF WALL
L/LA CONP/SR DDG L/LA SERVICES
FROM ANESTHETIC INDUCTION ROOM EXIT BAY & (SLIDING DOOR ZONE
CL OF COLUMN (SLIDING DOOR OPTIONAL) SCRUB UP OPTIONAL) CL OF COLUMN
PLAN
REV DESCRIPTION DATE BY REV DESCRIPTION DATE BY COMPATIBILITY
1 FIRST ISSUE 27.01.23 AK
iHFG
Facility Guidelines
Health Facility Briefing System (HFBS) at: REVIT FILE NAME PAPER DRAWING ID ISSUE
www.healthdesign.com.au ©TAHPI
or-ca-i or-ca-i-1 1
This document is for advisory purpose only
iHFG Standard Components
Room Layout Sheet
PU/IN1
PU/IN1
CONP/SR CONTROL PANEL - SURGICAL, RECESSED IM/USU
CARDIAC/ECHO
PU/SAP
DDG DISPENSER - DISPOSABLE GLOVES (OPTIONAL)
OPS/R
DFP DOOR AND DOOR FRAME PROTECTION T/AMD
PU/IR
DFR DEFIBRILLATOR
PU/S
PU/S
HHU HYPO-HYPERTHERMIA UNIT T/G DFR BS1
900
TB/MY
CHR/A
IM/USU IMAGING - ULTRASOUND SCANNING UNIT DFP
T/A T/R
IVS IV STAND - MOBILE 600
KB KICKBUCKET & STAND
L/O2M LIGHT - OPERATING, 2-ARM, 1 LIGHT / 1 MONITOR 300 DOOR FROM
L/O3CM2 LIGHT - OPERATING, 3-ARM, 1 LIGHT WITH CAMERA / 2 MONITORS 150 STERILE SK4
SK4 STOCK
LIND/S LINEN CARRIER - DIRTY, SINGLE 0 SK4
MON/D MONITOR - DISPLAY PO/2E PO/2U PO/2E
ELEVATION 1
COM/1
MON/TS MONITOR - TOUCH SCREEN
OPS/R OBSERVATION PANEL WITH SLIDING PANEL - RADIATION SHIELDING
3000
OPV OBSERVATION PANEL WITH INTEGRAL VENETIAN BLINDS
PC2 WPFSR L/O3CM2 WPFSR PC2
PC2 PLASTERBOARD CORNICE, FLUSHED COVED
PO/1-32A POWER OUTLET - SINGLE, 32 AMPS
PO/2E POWER OUTLET - EMERGENCY, DOUBLE
PO/2U UNINTERRUPTED POWER SUPPLY - DOUBLE 2200
PO/C POWER OUTLET - CLEANER'S MON/D MON/TS WPFSR
MON/D (OPTIONAL) (OPTIONAL)
PTZ PAN-TILT-ZOOM CAMERA WV
(FULLY
PU/IN1 PUMP - INFUSION, SINGLE RECESSED, CBT/SER
PU/IR PUMP - INFUSION, RAPID OPTIONAL) (OPTIONAL)
MON/TS COAGULATION
PU/S PUMP - SYRINGE (OPTIONAL) CMP UNIT, ACT
PU/SAM PUMP - SUCTION, ASPIRATOR, MOBILE (FULLY RECESSED)
PU/SAP PUMP - SUCTION, ASPIRATOR, PORTABLE 1100
(OPTIONAL)
TP/HH
PO/1-32A
RAG RETURN AIR GRILLE 900
SBC
BS1 BS1 LIND/S LIND/S BNR
PO/2U
COM/2
SB
SB
SB SUCTION BOTTLE
PO/2U
PO/2U
COM/2
COM/2
COM/1
WPFSR
SBC SUCTION BOTTLE CARRIER 600 WV
KB KB
RAG
RAG
OPV
2 x MA (PERFUSIONIST ARM) 1200 CMP
1 x S (ANAESTHESIA ARM)
2 x S (PERFUSIONIST ARM)
SBC
SB
PO/C
ELEVATION 3
1 x TA/DC (FOR SUPPLY UNIT BRAKES)
Facility Guidelines
Health Facility Briefing System (HFBS) at: REVIT FILE NAME PAPER DRAWING ID ISSUE
www.healthdesign.com.au ©TAHPI
or-ca-i or-ca-i-2 1
This document is for advisory purpose only
iHFG Standard Components
Room Layout Sheet
GENERAL NOTES:
THIS DRAWING TO BE READ IN CONJUNCTION WITH R.D.S.
(ROOM DATA SHEETS) WHICH TAKES PRECEDENCE.
CEILING LEGEND:
CEILING TYPE
CORNICE TYPE
BP-PC2
2700 HEIGHT ABOVE F.F.L.
ELECTRICAL LEGEND:
MECHANICAL LEGEND:
SPRINKLER
CL OF ROOM
L/LA
PTZ
PBSR-PC2
L/CC L/CC L/CC 3000
2400
L/CC
L/CC
L/CCD L/CCD
SETTING OUT POINT
SETTING OUT FOR L/03CM2
CL OF ROOM
L/CC
PBSR
3000
2200
L/CC
L/CC
L/CCD L/CCD
L/CCD
L/CC
L/LA L/LA
Facility Guidelines
Health Facility Briefing System (HFBS) at: REVIT FILE NAME PAPER DRAWING ID ISSUE
www.healthdesign.com.au ©TAHPI
or-ca-i or-ca-i-3 1
This document is for advisory purpose only
iHFG Standard Components
Room Layout Sheet
ISOMETRIC VIEW 1
ISOMETRIC VIEW 2
Facility Guidelines
Health Facility Briefing System (HFBS) at: REVIT FILE NAME PAPER DRAWING ID ISSUE
www.healthdesign.com.au ©TAHPI
or-ca-i or-ca-i-4 1
This document is for advisory purpose only