H3DE型

The H3DE series solid-state timers are DIN track mounted devices designed for a wide AC/DC power supply range, offering various models for different applications, including multi-functional and standard types. They feature easy identification, high immunity to noise, and compliance with international safety standards. The timers support multiple operating modes, have a broad time setting range, and include accessories for installation.

Uploaded by

zc264042467
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
9 views34 pages

H3DE型

The H3DE series solid-state timers are DIN track mounted devices designed for a wide AC/DC power supply range, offering various models for different applications, including multi-functional and standard types. They feature easy identification, high immunity to noise, and compliance with international safety standards. The timers support multiple operating modes, have a broad time setting range, and include accessories for installation.

Uploaded by

zc264042467
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 34

Solid-state Timer

H3DE CSM_H3DE_DS_E_3_2

DIN Track Mounted, Standard 22.5-mm Width Timer Range


• A wide AC/DC power supply range (24 to 230 VAC/DC) reduces the number of timer models kept in stock. (except for H3DE-H)
• 12-VDC model available for a specific application. (H3DE-M2)
• Nameplate provided for easy timer identification and management.
• Terminal clamp left open when delivered.
• Finger protection terminal block to meet VDE0106/P100.
• Enables easy sequence checks through instantaneous outputs for a zero set value at any time range.
• Incorporates environment-friendly, cadmium-free contacts. (except for H3DE-H)
• High immunity to inverter noise.
• Approved by UL and CSA.
• Conforms to EN61812-1 and IEC60664-1 4 kV/2 for Low Voltage, and EMC Directives.

■ Broad Line-up of H3DE Series

H3DE

H3DE-M/S H3DE-F H3DE-G H3DE-H

Standard Timer Twin Timer Star-delta Timer Power OFF-delay Timer


H3DE-M H3DE-F H3DE-G H3DE-H
H3DE-S

Contents
Solid-state Timer
H3DE-M/-S...................................................................................................................................... 2
H3DE-F ........................................................................................................................................... 12
H3DE-G .......................................................................................................................................... 18
H3DE-H........................................................................................................................................... 24
Common to ALL Timers
Accessories..................................................................................................................................... 30
Precautions ..................................................................................................................................... 31

1
Solid-state Multi-functional Timer

H3DE-M/-S
• Eight operating modes (H3DE-M) and four operating modes
(H3DE-S) cover a wide range of applications.
• Programmable contact enables the building of a self-holding re-
lay circuit (-@2 models).
• A wide time setting range of 0.10 s to 120 h.

Model Number Structure


■ Model Number Legend
H3DE -
1 2
1. M : Multi-function type
S: Standard type
2. 2 : DPDT
1 : SPDT

Ordering Information
■ List of Models
Supply voltage Control output Model
Multi-function type Standard type
12 VDC Contact output: DPDT (time-limit output SPDT and switchable H3DE-M2 ---
SPDT (time-limit ←→ instantaneous)) (see note)
24 to 230 VAC/DC Contact output: DPDT (time-limit output SPDT and switchable H3DE-M2 H3DE-S2
SPDT (time-limit ←→ instantaneous)) (see note)
Contact output: SPDT (time-limit output SPDT) H3DE-M1 H3DE-S1

Note: Specify both the model number and supply voltage when ordering H3DE-M2.
Example: H3DE-M2 24 to 230 VAC/DC
Supply voltage

■ Accessories (Order Separately)


Optional Products for Track Mounting Model
Mounting Track 50 cm (l) x 7.3 mm (t) PFP-50N
1 m (l) x 7.3 mm (t) PFP-100N
1 m (l) x 16 mm (t) PFP-100N2
End Plate PFP-M
Spacer PFP-S

2
H3DE-M/-S
Specifications
■ General
Item H3DE-M2 H3DE-M1 H3DE-S2 H3DE-S1
Operating mode A: ON-delay (Signal or Power) A: ON-delay
B: Flicker OFF start (Signal or Power) B2: Flicker ON start
B2: Flicker ON start (Signal or Power) E: Interval
C: Signal ON/OFF-delay J: One-shot
D: Signal OFF-delay
E: Interval (Signal or Power)
G: Signal ON/OFF-delay
J: One-shot (Signal or Power)
Terminal block Clamps two 2.5 mm2 max. bar terminals without sleeves.
Terminal screw tightening 0.98 N·m max. {approx. 10 kgf·cm max.}
torque
Input type Voltage input ---
Output type Relay: DPDT Relay: SPDT Relay: DPDT Relay: SPDT
Mounting method DIN track mounting (see note)
Attachment Nameplate
Approved standards UL508, CSA 22.2 No.14
Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P100
Output category according to IEC60947-5-1 (AC-13; 250 V 5A/AC-15; 250 V 3 A/DC-13; 30 V 0.1 A)

Note: Can be mounted to 35-mm DIN track with a plate thickness of 1 to 2.5 mm.

■ Time Ranges
Time scale display Time unit display
sec min hrs 10 h
x 0.1 0.1 to 1.2 s 0.1 to 1.2 min 0.1 to 1.2 h 1 to 12 h
x1 1 to 12 s 1 to 12 min 1 to 12 h 10 to 120 h

Note: When the main dial is set to “0” for all settings, the output will operate instantaneously.

■ Ratings
Rated supply voltage 24 to 230 VAC/DC (50/60 Hz)
(see notes 1 and 2) 12 VDC (H3DE-M2 model only)
Operating voltage range 85% to 110% of rated supply voltage
Power reset Minimum power-off time: 0.1 s
Reset voltage 2.4 VAC/DC max.
Power consump- H3DE-M1 AC: approx. 4.3 VA (2.2 W) at 230 VAC
tion (see note 3) DC: approx. 0.7 W at 24 VDC
H3DE-M2 AC: approx. 4.8 VA (2.4 W) at 230 VAC
DC: approx. 1.0 W at 24 VDC
H3DE-S1 AC: approx. 2.7 VA (1.6 W) at 230 VAC
DC: approx. 0.7 W at 24 VDC
H3DE-S2 AC: approx. 3.2 VA (1.9 W) at 230 VAC
DC: approx. 1.0 W at 24 VDC
Voltage input Max. permissible capacitance between input lines (terminals B1 and A2): 2000 pF
Load connectable in parallel with inputs (terminals B1 and A2)
H-level: 20.4 to 253 VAC/DC
L-level: 0 to 2.4 VAC/DC
Control output Contact output: 5 A at 250 VAC with resistive load (cosφ = 1)
5 A at 30 VDC with resistive load (cosφ = 1)
Ambient temperature Operating: -10°C to 55°C (with no icing)
Storage: -25°C to 65°C (with no icing)
Ambient humidity Operating: 35% to 85%

Note: 1. DC ripple rate: 20% max.


2. Since an inrush current of 0.25 A will occur when using the power supply voltage at 24 VDC, pay careful attention when turning on or off
the power supply to the Timer with a solid-state output such as a sensor.
3. The power consumption is for mode A after the Timer counts the time-up time and for the AC input at 50 Hz. The power consumption of
the H3DE-M@ includes the input circuit with the B1 and A1 terminals short-circuited.

3
H3DE-M/-S
■ Characteristics
Accuracy of operating ±1% max. of FS (±1% ±10 ms max. at 1.2-s range) (see note 1)
time
Setting error ±10% ±50 ms max. of FS (see note 1)
Signal input time 50 ms min. (see note 1)
Influence of voltage ±0.5% max. of FS (±0.5% ±10 ms max. at 1.2-s range)
Influence of temperature ±2% max. of FS (±2%±10 ms max. at 1.2-s range)
Insulation resistance 100 MΩ min. at 500 VDC
Dielectric strength Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC for 1 min.
Between control output terminals and operating circuit: 2,000 VAC for 1 min.
Between contacts of different polarities: 2,000 VAC for 1 min.
Between contacts not located next to each other: 1,000 VAC for 1 min.
Vibration resistance Malfunction: 0.5-mm single amplitude at 10 to 55 Hz
Destruction: 0.75-mm single amplitude at 10 to 55 Hz
Shock resistance Malfunction: 100 m/s2
Destruction: 1,000 m/s2
Contact material AGNi+gold plating (Use the G6RN-1 at 12 VDC.)
Impulse withstand volt- 3 kV (between power terminals)
age 4.5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts)
Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) ±1.5 kV
Static immunity Malfunction: 4 kV
Destruction: 8 kV
Life expectancy Mechanical: 10 million operations min. (under no load at 1,800 operations/h)
Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h)
(see note 2)
EMC (EMI) EN61812-1
Emission Enclosure: EN55011 Group 1 class B
Emission AC Mains: EN55011 Group 1 class B
Harmonic Current: EN61000-3-2
Voltage Fluctuation and Flickering: EN61000-3-3
(EMS) EN61812-1
Immunity ESD: EN61000-4-2: 6 kV contact discharge (level 3)
8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity Burst: EN61000-4-4: 2 kV power port and output port (level 3)
1 kV control port with capacitive clamp (level 3)
Immunity Surge: EN61000-4-5: 2 kV common mode (level 3)
1 kV differential mode (level 3)
Degree of protection IP30 (Terminal block: IP20)
Weight 120 g

Note: 1. With the H3DE-M@, if the voltage exceeds 26.4 VAC/DC, the following hold at signal OFF for C, D, and G modes:
Accuracy of operating time: ±1% ±50 ms max. at 1.2-s range
Setting error: ±10% +100/-50 ms max.
Signal input time: 100 ms min.
2. For reference: A maximum current of 0.15 A can be switched at 125 VDC (cosφ=1).
A maximum current of 0.1 A can be switched if L/R is 7 ms.
In both cases, a life of 100,000 operations can be expected.
The minimum applicable load is 10 mA at 5 VDC (failure level: P).

4
H3DE-M/-S
Connections
■ Block Diagram
H3DE-M1/-M2
AC (DC) input Zero setting
Time scale/ Operating
detection
unit selectors mode selector
circuit

Power supply Oscillation Counting


Output circuit
circuit circuit circuit

Indicator
Start input Input circuit circuit

Power-ON Output
indicator indicator

H3DE-S1/-S2
Zero setting
AC (DC) input Time scale/ Operating
detection
circuit unit selectors mode selector

Power supply Oscillation Counting


Output circuit
circuit circuit circuit

Indicator
circuit

Power-ON Output
indicator indicator

■ I/O Functions
Item H3DE-M1/-M2 H3DE-S1/-S2
Input Start Starts operation. No input is available.
Output Control output Outputs are turned ON according to designated out- Outputs are turned ON according to designated out-
put mode when preset value is reached. (See note.) put mode when preset value is reached. (see note.)
Note: When the output type selector switch on the bottom of the Timer is set to the instantaneous side, the relay R2 (terminal numbers 21/25, 22/
26, and 24/28) becomes an instantaneous contact and turns ON/OFF in synchronization with the changes in the power supply.

5
H3DE-M/-S
■ Terminal Arrangement
H3DE-M1 H3DE-M2 H3DE-S1 H3DE-S2

-------------------------------------------------

-------------------------------------------------
-------------------------------------------------
-------------------------------------------------

-------------------------------------------------
-------------------------------------------------

-------------------------------------------------
-------------------------------------------------

-------------------------------------------------
-------------------------------------------------
-------------------------------------------------
-------------------------------------------------
25/21
A1 15 A1 15 A1 15 A1 15 25
/21

(see note 1) (see note 1)


R1 R1 R2 R1 R1 R2
15 15 25/21 15 15 25/21

28/24 26/22 18 16
18 16 18 16 18 16 28/2426/22

28/24 26/22 B1 28/24 26/22


B1

------------
------------

18 16 A2 18 16 A2 18 16 A2 18 16 A2

(see note 2) (see note 2) (see note 2) (see note 2)

(DIN notation) (DIN notation) (DIN notation) (DIN notation)

Note: 1. The relay R2 can be set to either instantaneous or time-limit contact using the switch located on the bottom of the Timer.
2. DC supply voltage does not require the designation of polarity.
3. The contact symbol for the H3DE is indicated with because it offers multiple operating modes and is different from the delayed
contact for conventional timers.

■ Input Connections
The inputs of the H3DE-M1/-M2 are voltage (voltage imposition or open) inputs.

No-contact Input No-contact Input Contact Input


(Connection to PNP output sensor.) (Connection to NPN output sensor.)
Sensor
Timer

(+) A2
Timer Timer
24 VDC
(−)
B1 A1
B1 A1 B1 A1
(+)
Start Start
24 VDC
(−) A2 A2

Operates with PNP transistor ON Sensor Operates with relay ON


Operates with NPN transistor ON

Voltage Input Signal Levels


1. Transistor ON
Residual voltage: 1 V max.
No-contact (Voltage between terminals B1 and A2 must be more than
input the rated "H-level" voltage (20.4 VDC min.).)
2. Transistor OFF
Leakage current: 0.01 mA max.
(Voltage between terminals B1 and A2 must be less than
the rated "L-level" voltage (2.4 VDC max.).)
Use contacts that can adequately switch 0.1 mA at each
Contact voltage to be imposed. (When the contacts are ON or
input OFF, voltage between terminals B1 and A2 must be within
the following ranges:
When contacts are ON: 20.4 to 253 VAC/DC
When contacts are OFF: 0 to 2.4 VAC/DC

6
H3DE-M/-S
Operation
■ Basic Operation
Setting of Selector
The selectors can be turned clockwise and counterclockwise to Selection of Time Unit and Time Scale
select the desired time unit, time scale, or operating mode.
The desired time unit (s, m, h, or 10h) can be displayed in the time
Each selector has a snap mechanism that secures the selector at a unit display window above the time setting dial by turning the time
given position. Set the selector at a position at which it is secured. Do unit selector located at the upper right corner of the front panel. Time
not set it midway between two securing positions or a malfunction scale (0.1 or 1) is selected with the time scale selector at the upper
could result from improper setting. left corner of the front panel, it appears in the time scale display win-
dow above the selector.

Time unit display


window
Time scale display
window

Operating
mode selector Time scale
selector
Operating
mode display
window

Time unit selector


Selection of Operating Mode
The H3DE-M/-S can be set to any one of the operating modes A to J.
Turn the operating mode selector with a screwdriver until the desired
operating mode (A, B, C, B2, D, E, J, or G for the H3DE-M and A, E,
J, or B2 for the H3DE-S) appears in the operating mode display win-
dow located below the selector.

7
H3DE-M/-S
■ Timing Chart
Note: 1. The minimum power reset time is 0.1 s and the minimum signal input time is 0.05 s.
2. The letter “t” in the timing charts stands for the set time and “t–a” means that the period is less than the time set.
3. There is no start input with H3DE-S@ models. Operation starts when the power is turned ON.
4. There is no instantaneous output with H3DE-M1/-S1 models.
Operating Timing chart
mode
A: ON-delay t
t−a
t
Power (A1 and A2) Basic operation

Start (B1 and A2)


(see note) Power
Time-limit contacts: NC
15 and 16 (25 and 26)
**
*
Time-limit contacts: NO Start
(output indicator) t
15 and 18 (25 and 28)

Instantaneous contacts: Output


NC 25 and 26

Instantaneous contacts: * For power-on operation, impose voltage to the


NO 25 and 28 Start input. The Timer starts operating at the
moment the power is turned on.
Power indicator ** Start input is invalid while the Timer is in
operation.
B: t t
t−a
t t t
t−a
Basic operation
Flicker OFF Power (A1 and A2)
start
Power
Start (B1 and A2)
(see note) **
Output relay: NC 15 *
and 16 (25 and 26) Start
Output relay: NO t t t t
(output indicator)
15 and 18 (25 and 28) Output
Instantaneous contacts:
NC 25 and 26 * For power-on operation, impose voltage to the
Start input. The Timer starts operating at the
Instantaneous contacts: moment the power is turned on.
NO 25 and 28 ** Start input is invalid while the Timer is in
operation.
Power indicator
B2: t t
t−a
t t t
t−a
Flicker ON Power (A1 and A2)
start Basic operation
Start (B1 and A2)
(see note)
Power
Output relay: NC 15
and 16 (25 and 26) **
*
Output relay: NO Start
(output indicator)
15 and 18 (25 and 28) t t t t
Instantaneous contacts:
NC 25 and 26 Output

Instantaneous contacts: * For power-on operation, impose voltage to the


NO 25 and 28 Start input. The Timer starts operating at the
moment the power is turned on.
** Start input is invalid while the Timer is in
Power indicator operation.
C: t t t
t−a
t
t−a
Signal ON/
OFF-delay Power (A1 and A2)

Start (B1 and A2)


(see note) Basic operation
Output relay: NC 15
and 16 (25 and 26)
Power
Output relay: NO
(output indicator)
15 and 18 (25 and 28) *
Instantaneous contacts: Start
NC 25 and 26 t t t t
Instantaneous contacts: Output
NO 25 and 28

* Start input is valid and retriggerable while the


Power indicator Timer is in operation.

Note: The start input of the H3DE-M1 or H3DE-M2 model is activated by applying a voltage to B1 and A2 terminals.
The voltage can be applied by turning on the contact between B1 and A1 (Refer to Terminal Arrangement on page 6)

8
H3DE-M/-S
.

Operating Timing chart


mode
D: t−a t−a t−a
t t
Signal OFF- Power (A1 and A2)
delay Basic operation
Start (B1 and A2)
(see note)
Output relay: NC 15
and 16 (25 and 26)
Power
Output relay: NO
(output indicator) *
15 and 18 (25 and 28) Start
Instantaneous contacts: t
NC 25 and 26
Output
Instantaneous contacts:
NO 25 and 28
* Start input is valid and retriggerable while the
Power indicator Timer is in operation.

E: Interval t t
t−a t−a
t
Power (A1 and A2) Basic operation

Start (B1 and A2)


(see note) Power
Output relay: NC 15
and 16 (25 and 26) **
*
Output relay: NO
Start
(output indicator) t
15 and 18 (25 and 28)
Instantaneous contacts: Output
NC 25 and 26

Instantaneous contacts:
* For power-on operation, impose voltage to the
NO 25 and 28
Start input. The Timer starts operating at the
moment the power is turned on.
** Start input is valid and retriggerable while the
Power indicator Timer is in operation.

G: t t t
t−a
t
t−a
Signal ON/
Power (A1 and A2)
OFF-delay
Start (B1 and A2) Basic operation
(see note)
Output relay: NC 15
and 16 (25 and 26) Power
Output relay: NO
(output indicator) *
15 and 18 (25 and 28)
Start
Instantaneous contacts: t t t t
NC 25 and 26

Instantaneous contacts: Output


NO 25 and 28
* Start input is valid and retriggerable while the
Power indicator Timer is in operation.

J: t t
t−a t−a
t
One-shot out- Power (A1 and A2)
put Basic operation
(ON delay) Start (B1 and A2)
(see note)
Power
Output relay: NC 15
and 16 (25 and 26)
**
Output relay: NO Approx. Approx. Approx. *
(output indicator) 1+0.6 s 1+0.6 s 1+0.6 s Start
15 and 18 (25 and 28) (fixed) (fixed) (fixed)

Instantaneous contacts: t Approx. 1+0.6 s


NC 25 and 26
Output (fixed)
Instantaneous contacts: * For power-on operation, impose voltage to the
NO 25 and 28 Start input. The Timer starts operating at the
moment the power is turned on.
** Start input is valid and retriggerable while the
Power indicator Timer is in operation.

Note: The start input of the H3DE-M1 or H3DE-M2 model is activated by applying a voltage to B1 and A2 terminals.
The voltage can be applied by turning on the contact between B1 and A1 (Refer to Terminal Arrangement on page 6).

9
H3DE-M/-S
Nomenclature
Nameplate for user use (20
x 5.4 mm white panel)
Time scale display window Time unit display window
Time scale selector Time unit selector (select one from
(select 0.1 or 1) sec, min, hrs, and 10 h)

Main dial (for setting a time value)


Output indicator (orange)
(Lit while Timer gives output.)

Operating mode selector


(select a mode from A, B, C, Operating mode display window
B2, D, E, J, and G for the
H3DE-M1/-M2, from A, E, J,
and B2 for the H3DE-S1/S2)

Power-on indicator (green)


(Lit while the power is on.)

(Front View)

Output Type Selector Switch Settings

Setting Output type

Time-limit output (terminal numbers 25, 26 and


28) (default setting)
Output type selector switch for
H3DE-M2/-S2 (default setting
is time-limit output) Instantaneous output
(terminal numbers 21, 22 and 24)

(Bottom View)

10
H3DE-M/-S
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Terminal block (black)

H3DE-M/-S
Surface color: Light gray 5Y7/1 (OMRON)

Output type selector switch (default setting: Time-limit output)

Terminal block (black)

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.


To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

In the interest of product improvement, specifications are subject to change without notice.

11
Solid-state Twin Timer

H3DE-F
• Operates in flicker-OFF or flicker-ON start mode with one Unit.
• Independent ON- and OFF-time settings.
Combinations of long ON- or OFF-time and short OFF- or ON-
time setting are possible.
• Long time range from 0.1 s to 12 h for both ON and OFF time
settings.

Model Number Structure


■ Model Number Legend
H3DE -
1

1. F: Twin timers

Ordering Information
■ List of Models
Operating mode Supply voltage Model
Flicker-OFF/Flicker-ON start 24 to 230 VAC/VDC H3DE-F

■ Accessories (Order Separately)


Optional Products for Track Mounting Model
Mounting Track 50 cm (l) x 7.3 mm (t) PFP-50N
1 m (l) x 7.3 mm (t) PFP-100N
1 m (l) x 16 mm (t) PFP-100N2
End Plate PFP-M
Spacer PFP-S

12
H3DE-F
Specifications
■ General
Item H3DE-F
Operating mode Flicker-OFF/Flicker-ON start
Operating/Reset method Time-limit operation/Time-limit reset or self-reset
Terminal block Clamps two 2.5 mm2 max. bar terminals without sleeves
Terminal screw tightening torque 0.98 N·m max. {approx. 10 kgf·cm max.}
Output type Relay: SPDT
Mounting method DIN track mounting (see note)
Attachment Nameplate
Approved standards UL508, CSA 22.2 No.14
Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P 100
Output category according to IEC60947-5-1 (AC-13; 250 V 5A/AC-15; 250 V 3 A/DC-13; 30 V 0.1 A)

Note: Can be mounted to 35-mm DIN track with a plate thickness of 1 to 2.5 mm.

■ Time Ranges
Time scale display Time unit display
(see note 1)
sec 10 s min hrs
x 0.1 0.1 to 1.2 s 1 to 12 s 0.1 to 1.2 min 0.1 to 1.2 h
x1 1 to 12 s 10 to 120 s 1 to 12 min 1 to 12 h

Note: 1. Time scale display is applied commonly for ON and OFF time.
2. When the main dial is set to “0” for all settings, the output will operate instantaneously.

■ Ratings
Rated supply voltage (see note) 24 to 230 VAC/VDC (50/60 Hz)
Operating voltage range 85% to 110% of rated supply voltage
Power reset Minimum power-off time: 0.1 s
Reset voltage 2.4 VAC/DC max.
Power consumption AC: Approx. 3.1 VA (1.8 W) at 230 VAC
DC: Approx. 0.8 W at 24 VDC
Control output Contact output: 5 A at 250 VAC with resistive load (cosφ = 1)
5 A at 30 VDC with resistive load (cosf = 1)
Ambient temperature Operating: -10°C to 55°C (with no icing)
Storage: -25°C to 65°C (with no icing)
Ambient humidity Operating: 35% to 85%

Note: DC ripple rate: 20% max.

13
H3DE-F
■ Characteristics
Accuracy of operating time ±1% max. of FS (±1% ±10 ms max. at 1.2-s range)
Setting error ±10% ± 0.05 s max. of FS
Influence of voltage ±0.5% max. of FS (±0.5% ±10 ms max. at 1.2-s range)
Influence of temperature ±2% max. of FS (±2% ± 10 ms max. at 1.2-s range)
Insulation resistance 100 MΩ min. at 500 VDC
Dielectric strength Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC (50/60 Hz) for 1
min.
Between control output terminals and operating circuit: 2,000 VAC (50/60 Hz) for 1 min.
Between contacts not located next to each other: 1,000 VAC (50/60 Hz) for 1 min.
Impulse withstand voltage 3 kV (between power supply terminals)
4.5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts)
Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) ±1.5 kV
Static immunity Malfunction: 4 kV
Destruction: 8 kV
Vibration resistance Malfunction: 0.5-mm single amplitude at 10 to 55 Hz
Destruction: 0.75-mm single amplitude at 10 to 55 Hz
Shock resistance Malfunction: 100 m/s2
Destruction: 1,000 m/s2
Life expectancy Mechanical: 10 million operations min. (under no load at 1,800 operations/h)
Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h)
EMC (EMI) EN61812-1
Emission Enclosure: EN55011 Group 1 class B
Emission AC Mains: EN55011 Group 1 class B
Harmonic Current: EN61000-3-2
Voltage Fluctuation and Flickering: EN61000-3-3
(EMS) EN61812-1
Immunity ESD: EN61000-4-2: 6 kV contact discharge (level 3)
8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity Burst: EN61000-4-4: 2 kV power port and output port (level 3)
1 kV control port with capacitive clamp (level 3)
Immunity Surge: EN61000-4-5: 2 kV common mode (level 3)
1 kV differential mode (level 3)
Degree of protection IP30 (IP20 for terminal block)
Weight Approx. 110 g

Note: For reference:


A maximum current of 0.15 A can be switched at 125 VDC (cosφ=1).
A maximum current of 0.1 A can be switched if L/R is 7 ms.
In both cases, a life of 100,000 operations can be expected.
The minimum applicable load is 10 mA at 5 VDC (failure level: P).

14
H3DE-F
Connections
■ Block Diagram

ON OFF
indicator indicator ON/OFF start
selector

AC (DC) Indicator Time unit


input circuit selector

ROM RAM Clock

One-chip microcomputer
Power Output
supply circuit
circuit

■ I/O Function
Inputs ---
Outputs Control output Outputs are turned ON/OFF according to the time set by the ON-and OFF-time setting dial.

■ Terminal Arrangement

(DIN notation)

15
A1

A2
16 18

Note: DC supply voltage does not require the designation of polarity.

15
H3DE-F
Operation
■ Basic Operation
Time Unit Selection Time Scale Selection
The time unit display window for output ON is located on the upper- The time scale selector on the upper-left side of the front panel can
right side of the front panel above the corresponding time unit selec- be set to 0.1 or 1 as a magnification coefficient.
tor.
The time unit display window for output OFF is located on the lower-
right side of the front panel below the corresponding time unit selec-
tor.
According to the setting of each time unit selector, “sec” for seconds,
“10s” for 10 seconds, “min” for minutes, or “hrs” for hours will appear Time scale display window
in the corresponding time unit display window. Time scale selector
ON-time setting
dial

ON-time unit display window

ON-time unit selector (select OFF-time setting dial


one from sec, 10 s, min, or hrs)

Time Setting
OFF-time unit selector (select
one from sec, 10 s, min, or hrs) Use the ON/OFF-time setting dial to set the ON/OFF time.

OFF-time unit display window

■ Timing Charts
Operating Timing chart
mode
Flicker-OFF 0.1 s min.
start Power (A1 and A2) ON
OFF

Output relay: NO ON
15 and 18 OFF
(ON indicator)
Output relay: NC ON
15 and 16 OFF
ON
OFF indicator OFF
tON: ON set time
tOFF: OFF set time
Flicker-ON 0.1 s min.
start Power (A1 and A2) ON
OFF

Output relay: ON
NO 15 and 18 OFF
(ON indicator)
Output relay: NC ON
15 and 16 OFF
ON
OFF indicator OFF
tON: ON set time
tOFF: OFF set time

Note: 1. The reset time requires a minimum of 0.1 s.


2. When power is supplied in flicker-ON start mode, the OFF indicator lights momentarily. This, however, has no effect on the performance
of the Timer.

16
H3DE-F
Nomenclature
Nameplate for user use (20 x 5.4 mm white panel)

Time scale display window ON-time unit display window

Time scale selector Time unit selector


(select 0.1 or 1) (select one from s, 10s, min, or h for output ON)
Output ON indicator (orange) ON-time setting dial

OFF-time setting dial


Output OFF indicator (green)

OFF-time unit selector


(select one from s, 10s, min, or h)

OFF-time unit display window

(Front View)

ON/OFF Start Selector Switch Settings


Setting Operating mode
Flicker-ON start

ON/OFF start selector Flicker-OFF start


(default is flicker-OFF start)

(Bottom View)

Dimensions
Terminal block (black)

H3DE-F

Surface color:
Light gray 5Y7/1
(OMRON)

Terminal block (black)

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.


To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

In the interest of product improvement, specifications are subject to change without notice.

17
Solid-state Star-delta Timer

H3DE-G
• A wide star-time range (up to 120 seconds) and star-delta trans-
fer time range (up to 0.5 seconds)

Model Number Structure


■ Model Number Legend
H3DE -
1

1. G: Star-delta timer

Ordering Information
■ List of Models
Supply voltage Model
24 to 230 VAC/VDC H3DE-G

■ Accessories (Order Separately)


Optional Products for Track Mounting Model
Mounting Track 50 cm (l) x 7.3 mm (t) PFP-50N
1 m (l) x 7.3 mm (t) PFP-100N
1 m (l) x 16 mm (t) PFP-100N2
End Plate PFP-M
Spacer PFP-S

18
H3DE-G
Specifications
■ General
Item H3DE-G
Operating mode Star-delta operation
Operating/Reset method Time-limit operation/Self-reset
Terminal block Clamps two 2.5 mm2 max. bar terminals without sleeves
Terminal screw tightening torque 0.98 N·m max. {approx. 10 kgf·cm max.}
Output type (Star operation circuit) Relay: SPDT
(Delta operation circuit) Relay: SPDT
Mounting method DIN track mounting (see note)
Attachment Nameplate
Approved standards UL508, CSA 22.2 No.14
Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P100
Output category according to IEC60947-5-1 (AC-13; 250 V 5A/AC-15; 250 V 3 A/DC-13; 30 V 0.1 A)

Note: Can be mounted to 35-mm DIN track with a plate thickness of 1 to 2.5 mm.

■ Time Ranges
Time scale display Star operation time ranges
x1 1 to 12 s
x 10 10 to 120 s

Star-delta transfer time Programmable at 0.05 s, 0.1 s, 0.25 s or 0.5 s

■ Ratings
Rated supply voltage (see note) 24 to 230 VAC/VDC (50/60 Hz)
Operating voltage range 85% to 110% of rated supply voltage
Power reset Minimum power-off time: 0.5 s
Reset voltage 24 VAC/DC max.
Power consumption AC: Approx. 3 VA (1.8 W) at 230 VAC
DC: Approx. 0.8 W at 24 VDC
Control output Contact output: 5 A at 250 VAC with resistive load (cosφ = 1)
5 A at 30 VDC with resistive load (cosφ = 1)
Ambient temperature Operating: -10°C to 55°C (with no icing)
Storage: -25°C to 65°C (with no icing)
Ambient humidity Operating: 35% to 85%
Note: DC ripple rate: 20% max.

19
H3DE-G
■ Characteristics
Accuracy of operating time ±1% max. of FS
Setting error ±10% ± 0.05 s max. of FS
Total tolerance of transfer ± (25% FS + 5 ms) max.
time
Influence of voltage ±0.5% max. of FS
Influence of temperature ±2% max. of FS
Insulation resistance 100 MΩ min. at 500 VDC
Dielectric strength Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC (50/60 Hz) for 1
min.
Between control output terminals and operating circuit: 2,000 VAC (50/60 Hz) for 1 min.
Between contacts not located next to each other: 1,000 VAC (50/60 Hz) for 1 min.
Impulse withstand voltage 3 kV (between power supply terminals)
4.5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts)
Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 ms, 1-ns rise) ±1.5 kV
Static immunity Malfunction: 4 kV
Destruction: 8 kV
Vibration resistance Malfunction: 0.5-mm single amplitude at 10 to 55 Hz
Destruction: 0.75-mm single amplitude at 10 to 55 Hz
Shock resistance Malfunction: 100 m/s2
Destruction: 1,000 m/s2
Life expectancy Mechanical: 10 million operations min. (under no load at 1,800 operations/h)
Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h)
EMC (EMI) EN61812-1
Emission Enclosure: EN55011 Group 1 class B
Emission AC Mains: EN55011 Group 1 class B
Harmonic Current: EN61000-3-2
Voltage Fluctuation and Flickering: EN61000-3-3
(EMS) EN61812-1
Immunity ESD: EN61000-4-2: 6 kV contact discharge (level 3)
8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity Burst: EN61000-4-4: 2 kV power port and output port (level 3)
1 kV control port with capacitive clamp (level 3)
Immunity Surge: EN61000-4-5: 2 kV common mode (level 3)
1 kV differential mode (level 3)
Degree of protection IP30 (IP20 for terminal block)
Weight Approx. 120 g

Note: For reference:


A maximum current of 0.15 A can be switched at 125 VDC (cosφ=1).
A maximum current of 0.1 A can be switched if L/R is 7 ms.
In both cases, a life of 100,000 operations can be expected.
The minimum applicable load is 10 mA at 5 VDC (failure level: P).

20
H3DE-G
Connections
■ Block Diagram

AC (DC) input Star Star-delta


operation transfer
time scale time
selector selection

Star Star Star-delta Star-delta


Power operation operation transfer transfer Star operation
supply time time time time
circuit oscillation counting oscillation counting Output
circuit circuit circuit circuit circuit
Delta operation

Indicator
circuit

Star operation Delta operation


indicator indicator

■ I/O Functions
Inputs ---
Outputs Control output Star output is turned OFF when the dial set value is reached and delta output is ON after
the preset transfer time elapses

■ Terminal Arrangement
---------------------------------------------------------------
---------------------------------------------------------------
---------------------------------------------------------------

25
Delta contact
Star contact

15 25

18 16 28 26

28 26

(DIN notation)

15 25
A1

A2
16 18 26 28

Note: DC supply voltage does not require the designation of polarity.

21
H3DE-G
Operation
■ Basic Operation
Time Unit Setting Time Scale Selection
The star-delta transfer time is set to 0.05, 0.1, 0.25 or 0.5 with the The star operation time scale selector on the upper-left side of the
star-delta transfer time selector on the lower-right side of the front front panel can be set to 1 or 10 as a magnification.
panel and the set value appears in the star-delta transfer time display
window below the selector.

Star operation time


scale display window
Star operation time
scale selector

Time setting dial


Star-delta transfer time selector
Star-delta transfer time display
window
Time Setting
The operation time of the Timer is set with the time setting dial.

■ Timing Charts
0.5 s
Power (A1 and A2) ON
OFF
Star contact
15 and 18 ON
(star indicator) OFF
Star contact ON
15 and 16 OFF
Delta contact ON
25 and 28 OFF
(delta indicator)
Delta contact ON
25 and 26 OFF
t1: Star operation time setting
t2: Star-delta transfer time

Note: The reset time requires a maximum of 0.5 s.

Nomenclature
Nameplate for user use (20 x 5.4 mm white panel)

Time scale display window

Star operation time scale selector


(select 1 or 10)
Time setting dial (for setting star operation time)
Star operation indicator (green)

Delta operation indicator (orange)


Star-delta transfer time selector

Star-delta transfer time display window

(Front View)

22
H3DE-G
Dimensions
Terminal block (black)

H3DE-G

Surface color:
Light gray 5Y7/1
(OMRON)

Terminal block (black)

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.


To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

In the interest of product improvement, specifications are subject to change without notice.

23
Solid-state Power OFF-delay Timer

H3DE-H
• Two delay-time models available.
0.1 to 12 seconds (S Series)
1 to 120 seconds (L Series)
• Covers wide range of supply voltage.

Model Number Structure


■ Model Number Legend
H3DE -
1

1. H: Power OFF-delay timer

Ordering Information
■ List of Models
Supply voltage Model
S Series (time range: 0.1 to 12 s) L Series (time range: 1 to 120 s)
100 to 120 VAC H3DE-H H3DE-H
200 to 230 VAC
24 VAC/VDC
48 VAC/VDC

Note: Specify both the model number and supply voltage when ordering.
Example: H3DE-H 24 VAC/DC S
Time span code
Supply voltage

■ Accessories (Order Separately)


Optional Products for Track Mounting Model
Mounting Track 50 cm (l) x 7.3 mm (t) PFP-50N
1 m (l) x 7.3 mm (t) PFP-100N
1 m (l) x 16 mm (t) PFP-100N2
End Plate PFP-M
Spacer PFP-S

24
H3DE-H
Specifications
■ General
Item H3DE-H
Operating mode Power OFF-delay
Operating/Reset method Instantaneous operation/Time-limit reset
Terminal block Clamps Two 2.5 mm2 max. bar terminals without sleeves
Terminal screw tightening torque 0.98 N·m max. {approx. 10 kgf·cm max.}
Output type Relay: SPDT
Mounting method DIN track mounting (see note)
Attachment Nameplate
Approved standards UL508, CSA 22.2 No.14
Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P100
Output category according to IEC60947-5-1 (AC-13; 250 V 5A/AC-15; 250 V 3 A/DC-13; 30 V 0.1 A)

Note: Can be mounted to 35-mm DIN track with a plate thickness of 1 to 2.5 mm.

■ Time Ranges
Time scale display Time ranges Min. power ON time
S series x 0.1 s 0.1 to 1.2 s 0.1 s minimum
x1s 1 to 12 s
L series x1s 1 to 12 s 0.3 s minimum
x 10 s 10 to 120 s

Note: The Timer will not operate if the specified power-on time is not kept. Be sure to supply power for at least the period specified.

■ Ratings
Rated supply voltage (see note) 100 to 120 VAC (50/60 Hz)
200 to 230 VAC (50/60 Hz)
24 VAC/VDC (50/60 Hz)
48 VAC/VDC (50/60 Hz)
Operating voltage range 85% to 110% of rated supply voltage
Power consumption 24 VAC/VDC Type AC: Approx. 0.3 VA (0.2 W) at 24 VAC
DC: Approx. 0.2 W at 24 VDC
48 VAC/VDC Type AC: Approx. 0.5 VA (0.5 W) at 48 VAC
DC: Approx. 0.5 W at 48 VDC
100 to 120 VAC Type AC: Approx. 0.8 VA (0.7 W) at 120 VAC
200 to 230 VAC Type AC: Approx. 1.6 VA (1.0 W) at 230 VAC
Control output Contact output: 5 A at 250 VAC with resistive load (cosφ = 1)
5 A at 30 VDC with resistive load (cosφ = 1)
Ambient temperature Operating: -10°C to 55°C (with no icing)
Storage: -25°C to 65°C (with no icing)
Ambient humidity Operating: 35% to 85%

Note: The ripple in DC power supply must be 20% max. A single-phase, full-wave rectifying power supply can be connected if the ripple output of
the power supply is a maximum of 20% of the whole output.

25
H3DE-H
■ Characteristics
Accuracy of operating time ±1% max. of FS (±1% ±10 ms max. at 1.2-s range)
Setting error ±10% ± 0.05 s max. of FS
Influence of voltage ±0.5% max. of FS (±0.5% ±10 ms max. at 1.2-s range)
Influence of temperature ±2% max. of FS (±2% ± 10 ms max. at 1.2-s range)
Insulation resistance 100 MΩ min. at 500 VDC
Dielectric strength Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC (50/60 Hz) for 1
min.
Between control output terminals and operating circuit: 2,000 VAC (50/60 Hz) for 1 min.
Between contacts not located next to each other: 1,000 VAC (50/60 Hz) for 1 min.
Impulse withstand voltage 3 kV (or 1 kV for 24/48 VAC/VDC models) (between power supply terminals)
4.5 kV (or 1.5 kV for 24/48 VAC/VDC models) (between current-carrying metal parts and exposed non-current-
carrying metal parts)
Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 ms, 1-ns rise) ±1.5 kV (between power
supply terminals)
Static immunity Malfunction: 4 kV
Destruction: 8 kV
Vibration resistance Malfunction: 0.5-mm single amplitude at 10 to 55 Hz
Destruction: 0.75-mm single amplitude at 10 to 55 Hz
Shock resistance Malfunction: 100 m/s2
Destruction: 1,000 m/s2
Life expectancy Mechanical: 10 million operations min. (under no load at 1,200 operations/h)
Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,200 operations/h)
EMC (EMI) EN61812-1
Emission Enclosure: EN55011 Group 1 class A
Emission AC Mains: EN55011 Group 1 class A
Harmonic Current: EN61000-3-2
Voltage Fluctuation and Flickering: EN61000-3-3
(EMS) EN61812-1
Immunity ESD: EN61000-4-2: 6 kV contact discharge (level 3)
8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity Burst: EN61000-4-4: 2 kV power port and output port (level 3)
1 kV control port with capacitive clamp (level 3)
Immunity Surge: EN61000-4-5: 2 kV common mode (level 3)
1 kV differential mode (level 3)
Degree of protection IP30 (IP20 for terminal block)
Weight Approx. 120 g

Note: For reference:


A maximum current of 0.15 A can be switched at 125 VDC (cosφ=1).
A maximum current of 0.1 A can be switched if L/R is 7 ms.
In both cases, a life of 100,000 operations can be expected.
The minimum applicable load is 100 mA at 5 VDC (failure level: P).

26
H3DE-H
Connections
■ Block Diagram

Indicator Time scale


AC (DC) input circuit selector

Power supply Oscillation Counting Output


circuit circuit circuit circuit

Power failure
detection circuit

■ I/O Functions
Inputs ---
Outputs Control output The Timer operates instantaneously when the Timer is turned ON. The Timer is in counting operation
after the Timer is turned OFF and the output of the Timer is turned OFF when the preset time elapses.

■ Terminal Arrangement

(DIN notation)

15
A1

A2
16 18

Note: DC supply voltage does not require the designation of polarity.

27
H3DE-H
Operation
■ Basic Operation
Time Scale Selection Time Setting
The time scale selector on the upper left-hand side of the front panel The operating time of the Timer is set with the time setting dial.
of the S Series can be set to 0.1 or 1 and that of the L Series can be
set to 1 or 10 as magnification coefficients.

Time scale display window


Time scale selector

Time
setting
dial

■ Timing Charts
Power supply ON
(A1 and A2) OFF
Output relay: NC ON
15 and 16 OFF
Output relay: NO ON
15 and 18 OFF
Power indicator ON
OFF

t: Set time
Rt: Minimum power-on time (S-series: 0.1 s min.; L-series: 0.3 s min.)
(The output may never turn ON if this time or more is not ensured.)

Nomenclature
Nameplate for user use
(20 x 5.4 mm white panel)
Time scale
display window

Time scale selector Time setting dial (for setting


S Series: Set to 0.1 or 1 power OFF-delay time)
L Series: Set to 1 or 10

Power indicator (green)


Lit when the Timer is turned ON.

(Front View)

28
H3DE-H
Dimensions
Terminal block (black)

H3DE-H

Surface color:
Light gray 5Y7/1
(OMRON)

Terminal block (black)

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.


To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

In the interest of product improvement, specifications are subject to change without notice.

29
H3DE
Accessories (Order Separately) (Common)
Note: The following is common for all H3DE models.
Note: All units are in millimeters unless otherwise indicated.

■ Dimensions
Mounting Track
PFP-100N, PFP-50N PFP-100N2

16
7.3±0.15
4.5 4.5
27±0.15 35±0.3 27 24 29.2
35±0.3

15 25 25 25 25 * 15 25 25 25 25 15 1 1.5
1 10 10
10 10 L
L

L: Length
1m PFP-100N
50 cm PFP-50N
1m PFP-100N2

End Plate Spacer


PFP-M PFP-S
16
10 12
5
6.2
1.8

1
50 35.5 35.3 34.8
1.8 44.3

11.5 1.3
10 M4 x 8 4.8
pan head
screw 16.5

30
H3DE
Safety Precautions (Common)
Refer to Safety Precautions for All Timers.
Note: The following is common for all H3DE models.

■ Changing of Setting
!CAUTION ■ Power Supplies
Do not change the time unit, time scale, operating mode, or output The H3DE Series is provided with a transformerless power supply
type selector switch while the Timer is in operation or malfunction system. An electric shock may be received if the input terminal or the
could result. output type selector switch is touched while power is being supplied.
Use the bar terminal for wiring the H3DE. Using a stranded-wire ter-
■ Mounting and Dismounting minal may cause a short-circuit due to a stray wire entering into the
Timer.
The H3DE should be mounted as horizontally as possible. Both AC and DC power supplies can be connected to the power
When mounting the H3DE on a socket mounting track, hook portion input terminals without regarding polarity.
(A) of the Timer to an edge of the track first, and then depress the With the H3DE only, a DC power supply must be connected to the
Timer in the direction of (B). power input terminals as designated according to the polarity of the
terminals.
A DC power supply can be connected if its ripple factor is 20% or
less and the mean voltage is within the rated operating voltage range
of the Timer.
(A)
Connect the power supply voltage through a relay or switch in such a
way that the voltage reaches a fixed value at once or the Timer may
not be reset or a timer error could result.
For the power supply of an input device, use an isolating transformer,
of which the primary and secondary windings are mutually isolated
(B) and the secondary winding is not grounded.

A1
When dismounting the H3DE, pull out portion (C) with a flat-blade
screwdriver and remove the Timer from the mounting track. B1
H3DE Power supply
Start
input

A2
Rectifier circuit

Circuit

Isolation transformer is required.


The H3DE-H has a large inrush current; provide sufficient power
supply capacity. If the power supply capacity is too small, there may
be delays in turning ON the output.
(C) 30 mm min.

Rail stopper ■ Installation


The H3DE can be mounted and dismounted with ease if a distance If the load current is continuously being supplied to the Timer for a
of 30 mm or more is kept between the H3DE and the top surface of long period of time, be sure to provide the mounting clearance as
other equipment located below the H3DE. shown in the figure below. If used under the conditions other than
those specified below, the life of internal components may be short-
ened due to an excessive rise in the internal temperature.

H3DE H3DE H3DE


DIN track

t t
t: Mounting clearance (mm)

31
H3DE
Switching Current vs. Ambient Temperature Contact or transistor for
(When Mounting Two or More H3DE Units external input signal
A1
Side-by-Side)
B1
70 Mounting clearance:
Incorrect H3DE Power supply
50 mm
Ambient temperature (°C)

Mounting
60 clearance: 10 mm A2
Short-circuit
Maximum range of current
operating ambient
50 temperature
A1

40 Mounting
clearance: 5 mm B1
H3DE

30 Mounting
clearance: 0 mm
A2
20

Contact or transistor for


external input signal
A1
0 1 2 3 4 5 Load current (A)

■ Input/Output
B1
H3DE Power supply
Correct

Relationship between Input and Power A2


Short-circuit
Supply Circuits current
A1

B1
H3DE
B1 A1

AC/DC
power Input circuit Power supply
supply circuit A2

The H3DE Series is provided with a transformerless power supply


A2 system.

Since the input circuit and the power supply circuit are configured
independently, the input circuit can be turned on or off irrespective of
■ Input Wires
the on/off state of the power supply. The input wires must be as short as possible. If the floating capacity
It must be noted that a voltage equivalent to the power supply voltage of wires exceeds 2,000 pF (approx. 17 m for cables with 120 pF/m),
is applied to the input circuit. the operation will be affected. Pay particular attention when using
When connecting a relay or a transistor as an external signal input shielded cables.
device, pay attention to the following points to prevent short-circuiting
due to a sneak current to the transformerless power supply. ■ Wiring (H3DE-H)
If a relay or transistor is connected to two or more Timers, the input
terminals of those Timers must be wired properly so that they will not The H3DE has a high impedance circuit. Therefore, the H3DE may
be different in phase or the terminals will be short-circuited to one not be reset if the H3DE is influenced by inductive voltage. In order to
another (refer to the figures below). eliminate any influence of inductive voltage, the wires connected to
the H3DE must be as short as possible and should not be installed
alongside power lines. If the H3DE is influenced by inductive voltage
that is 30% or more of the rated voltage, connect a CR filter with a
capacitance of approximately 0.1 µF and a resistance of approxi-
mately 120 Ω or a bleeder resistor between the power supply termi-
nals. If there is any residual voltage due to current leakage, connect
a bleeder resistor between the power supply terminals.

32
H3DE
■ Operation (H3DE-H) ■ Environment
An interval of 3 s minimum is required to turn on the H3DE after the When using the Timer in an area with excess electronic noise, sepa-
H3DE is turned off. If the H3DE is turned on and off repeatedly with rate the Timer, wiring, and the equipment which generates the input
an interval of shorter than 3 s, the internal parts of the H3DE may signals as far as possible from the noise sources. It is also recom-
deteriorate and the H3DE may malfunction. mended to shield the input signal wiring to prevent electronic interfer-
ence.
3 s min.
Organic solvents (such as paint thinner), as well as very acidic or
Power basic solutions can damage the outer casing of the Timer.
Do not use the Timer in places where it is exposed to dust, corrosive
Output gas, or direct sunlight.
state 1
When storing the Timer, make sure that the ambient temperature
and humidity are within the rated values. Leave the Timer at room
Output temperature for at least three hours before using the Timer if it has
state 2 been stored at an ambient temperature of –10°C or below.
If it is required that the output be turned on repeatedly with an inter-
val of shorter than 3 s, consider use of the H3DE-M2/-M1 in mode D
(signal OFF-delay). ■ Others
If the Timer is mounted on a control board, dismount the Timer from
■ Precautions for EN61812-1 the control board or short-circuit the circuitry of the power board
before carrying out a voltage withstand test between the electric cir-
Conformance cuitry and non current-carrying metal part of the Timer, in order to
prevent the internal circuitry of the Timer from damage.
The H3DE as a built-in timer conforms to EN61812-1 provided that It must be noted that although the electrical life expectancy of the
the following conditions are satisfied: H3DE Timer shown in the catalog is the same as the H3DR Timer
The output section of the H3DE is provided only with basic isolation. shown in the catalog, the actual performance varies because the
To ensure reinforced isolation required by the EN61812-1, provide built-in relays are different as follows:
supplementary basic isolation on the load side connected to the out-
Built-in relay for the H3DR: G2R; 100,000 operations min.
put.
(10 A for SPDT and 5 A for DPDT at
The H3DE itself is designed according to the following: 250 VAC, resistive load at
1,800 operations/h.)
• Overvoltage category III
• Pollution degree 2 Built-in relay for the H3DE: G6RN; 50,000 operations min.
(8 A at 250 VAC, resistive load at
On the above basis: 360 operations/h.)
Operation parts on the front and bottom: Reinforced isolation
- With clearance of 5.5 mm and creepage distance of 5.5 mm at
230 VAC
Output: Basic isolation
- With clearance of 3 mm and creepage distance of 3 mm at
230 VAC

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.


To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

In the interest of product improvement, specifications are subject to change without notice.

33
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.

Warranty and Limitations of Liability

WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR


FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

Application Considerations

SUITABILITY FOR USE


OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.

• Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

Disclaimers

CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.

DIMENSIONS AND WEIGHTS


Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.

ERRORS AND OMISSIONS


The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

2010.10
In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2010 All Right Reserved.

You might also like