DC/DC C 28 V I: Onverters OLT Nput
DC/DC C 28 V I: Onverters OLT Nput
55 to +125C operation 16 to 40 VDC input Fully isolated Optocoupler feedback Fixed frequency, 550 kHz typical Topology Single Ended Forward 50 V for up to 50 ms transient protection Inhibit and sync functions Indefinite short circuit protection Undervoltage lockout Up to 84% efficiency, 28 W/in3
Size (max.): Non flanged 1.460 x 1.130 x 0.330 (37.08 x 28.70 x 8.38 mm) Flanged 2.005 x 1.130 x 0.330 (50.93 x 28.70 x 8.38 mm) Weight: 30 grams maximum. Screening: Standard, ES, or 883 (Class H).
DESCRIPTION
The MHF+ Series of high frequency DC/DC converters offers a wide input voltage range of 16 to 40 volts and up to 15 watts of output power. The units are capable of withstanding short term transients up to 50 volts. The package is a hermetically sealed, welded metal case. Flanged and non-flanged models are available.
INHIBIT FUNCTION
MHF+ converters provide an inhibit terminal that can be used to disable internal switching, resulting in no output and very low quiescent input current. The converter is inhibited when a TTL compatible low (0.8 output disabled) is applied to the inhibit pin. The unit is enabled when the pin, which is internally connected to a pull-up resistor, is left unconnected or is connected to an open-collector gate. The open circuit output voltage associated with the inhibit pin is 8.5 to 12 V. In the inhibit mode, a maximum of 4 mA must be sunk from the inhibit pin.
CONVERTER DESIGN
The MHF+ converters are switching regulators that use a quasisquare wave, single-ended forward converter design with a constant switching frequency of 550 kHz. Isolation between input and output circuits is provided with a transformer in the forward path and a temperature compensated optical link in the feedback control loop. For the MHF+ dual output models, good cross regulation is maintained by tightly coupled output magnetics. Up to 90% of the total output power (80% on 2805D) is available from either output, providing the opposite output is simultaneously carrying 10% of the total output power (20% on 2805D models). Predictable current limit is accomplished by directly monitoring the output load current and providing a constant current output above the overload point.
SYNCHRONIZATION
A synchronization feature is included with the MHF+ Series that allows the user to match the switching frequency of the converter to the frequency of the system clock. An external synchronization feature is included that allows the user to adjust the nominally 550 kHz operating frequency to any frequency within the range of 500 kHz to 600 kHz. This is initiated by applying a TTL compatible input of the desired frequency to pin 5.
UNDERVOLTAGE LOCKOUT
Undervoltage lockout prevents the units from operating below approximately 12 VDC input voltage to keep system current levels smooth, especially during initialization or re-start operations.
DC/DC CONVERTERS
SYNC AND INHIBIT
Sync In (500 to 600 kHz) Duty cycle 40% to 60% Logic low 0.8 V max Logic high 4.5 V min, 5 V max Referenced to input common If not used, connect to input common Inhibit TTL Open Collector Logic low (output disabled) Logic low voltage 0.8 V Inhibit pin current 4.0 mA max Referenced to input common Logic high (output enabled) Open collector or unconnected
TYPICAL CHARACTERISTICS
Output Voltage Temperature Coefficient 100 ppm/C typical 150 ppm/C maximum Input to Output Capacitance 60 pF typical Undervoltage Lockout 12 V input typical Current Limit 115% of full load typical Isolation 100 megohm minimum at 500 V Audio Rejection 50 dB typical Conversion Frequency (55C to +125C Tc) Free run 550 kHz typical 480 kHz min, 620 kHz max Inhibit Pin Voltage (unit enabled) 8.5 to 12 V
Electrical Characteristics: 25C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
SINGLE OUTPUT MODELS PARAMETER OUTPUT VOLTAGE OUTPUT CURRENT OUTPUT POWER OUTPUT RIPPLE VOLTAGE LINE REGULATION LOAD REGULATION INPUT VOLTAGE NO LOAD TO FULL INPUT CURRENT CONDITION VIN = 16 to 40 VDC VIN = 16 to 40 VDC 10 kHz - 2 MHz Tc = 55C to +125C Vin = 16 to 40 VDC NO LOAD TO FULL CONTINUOUS TRANSIENT 50 ms NO LOAD FULL LOAD INHIBITED 10 kHz - 10 MHz Tc = 55C to +125C SHORT CIRCUIT POWER DISSIPATION RECOVERY2 50% 100% 50% TRANSIENT RECOVERY2 16 40 16 VDC TRANSIENT3 RECOVERY2 DELAY OVERSHOOT4 MHF+283R3S MIN 3.27 0 0 16 72 400 800 TYP MAX 3.30 3.33 2.4 30 50 5 20 28 25 5 45 75 5 7.5 150 150 550 0.8 10 200 8 80 120 100 50 40 50 65 397 12 80 120 8 30 500 300 800 1.2 25 300 MHF+2805S MIN 4.95 0 0 16 75 400 800 TYP MAX 5.00 5.05 2.4 30 60 5 20 28 25 560 5 35 77 3.5 7.5 150 150 550 0.8 10 100 12 80 100 50 50 40 50 40 624 12 80 100 6 30 400 300 800 1.2 25 600 MHF+285R2S MIN 5.16 0 0 16 75 400 800 TYP MAX 5.20 5.24 2.4 30 60 5 20 28 25 560 5 35 77 3.5 7.5 150 150 550 0.8 10 100 12.48 50 100 35 35 40 50 42 605 12 100 100 6 30 400 300 800 1.2 25 600 UNITS VDC A W mV p-p mV mV VDC V mA
mA pp % W ms mV pk s mV pk ms ms mV pk
START-UP
Notes 1. Indefinite short circuit protection not guaranteed above 125C (case) 2. Recovery time is measured from application of the transient to the point at which Vout is within regulation.
3. Input step transition time >10 s. 4. Input step transition time <100 s.
DC/DC CONVERTERS
Electrical Characteristics: 25C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
SINGLE OUTPUT MODELS PARAMETER OUTPUT VOLTAGE OUTPUT CURRENT OUTPUT POWER OUTPUT RIPPLE VOLTAGE LINE REGULATION LOAD REGULATION INPUT VOLTAGE NO LOAD TO FULL INPUT CURRENT CONDITION VIN = 16 to 40 VDC VIN = 16 to 40 VDC 10 kHz - 2 MHz Tc = 55C to +125C Vin = 16 to 40 VDC NO LOAD TO FULL CONTINUOUS TRANSIENT 50 ms NO LOAD FULL LOAD INHIBITED 10 kHz - 10 MHz Tc = 55C to +125C SHORT CIRCUIT POWER DISSIPATION RECOVERY2 50% 100% 50% TRANSIENT RECOVERY2 16 40 40 VDC TRANSIENT3 RECOVERY2 DELAY OVERSHOOT4 MHF+2812S MIN TYP MAX 11.88 12.00 12.12 0 1.25 0 16 78 500 800 0 0 30 50 5 20 28 25 680 5 35 79 3.5 7.5 150 150 550 0.8 10 15 80 120 50 50 40 50 50 752 12 80 120 6 30 500 300 800 1.2 25 MHF+2815S MIN TYP MAX 14.85 15.00 15.15 0 1.00 0 16 78 600 800 0 0 30 50 5 20 28 25 670 5 35 80 3.5 7.5 200 150 550 0.8 10 15 80 120 50 50 40 50 62 752 12 80 120 6 30 600 300 800 1.2 25
mA pp % W ms mV pk s mV pk ms ms mV pk
START-UP
200 1200
200 1500
Notes 1. Indefinite short circuit protection not guaranteed above 125C (case) 2. Recovery time is measured from application of the transient to point at which Vout is within regulation.
3. Input step transition time >10 s. 4. Input step transition time <100 s.
DC/DC CONVERTERS
MHF+2805D MIN 4.95 4.92 16 77 600 600 800 0 TYP 5.00 5.00 1.2 30 60 5 20 6 28 20 540 6 20 40 79 3 7.5 200 150 150 600 0.8 12 100 MAX 5.05 5.08 1.92 12 80 120 50 80 50 100 7.5 40 50 40 600 12 50 80 6 30 600 600 500 800 1.2 20 250 MIN 11.88 11.82 16 76 600 600 750 0 MHF+2812D TYP 12.00 12.00 0.625 30 60 5 20 3 28 25 645 5 35 50 83 3 7.5 300 100 200 550 0.8 12 200 MAX 12.12 1218 1.125 15 80 120 50 100 50 100 6 40 50 50 754 12 60 100 6 50 600 500 400 750 1.2 25 750 MIN 14.85 14.78 16 76 600 600 750 0 MHF+2815D TYP 15.00 15.00 0.500 30 50 5 20 3 28 25 638 5 35 50 84 3 7.5 300 100 200 550 0.8 12 200 MAX 15.15 15.23 0.900 15 80 120 50 100 50 100 6 40 50 50 754 12 60 100 6 50 600 600 500 750 1.2 25 750 s mV pk ms ms mV pk % VDC V mA mV A W mV p-p mV UNITS VDC
Electrical Characteristics: 25C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
NEGATIVE VOUT CONTINUOUS TRANSIENT 50 msec NO LOAD FULL LOAD INHIBITED 10 kHz - 10 MHz Tc = 55C to +125C SHORT CIRCUIT3 POWER DISSIPATION RECOVERY4 50% 100% 50% +VOUT TRANSIENT VOUT RECOVERY4 16 40 40 VDC TRANSIENT6 RECOVERY4 DELAY OVERSHOOT7
mA p-p % W ms
mV pk
Notes 1. Up to 13.5 watts, 90% (9.6W, 80% for 2805D) of the total output power is available from either output providing the opposite output is simultaneously carrying 10% (20% for 2805D) of the total output power. Each output must carry a minimum of 10% (20% for 2805D) of the total output power in order to maintain regulation on the negative output. 2. Effect on Vout for the following conditions: +Po = 50% to 10% and Po = 50% +Po = 50% and Po = 50% to 10%
3. Indefinite short circuit protection not guaranteed above 125C (case) 4. Recovery time is measured from application of the transient to point at which Vout is within regulation. 5. Response of either output with the opposite output held at half of the total output power. 6. Input step transition time >10 s. 7. Input step transition time <100 s.
DC/DC CONVERTERS
BLOCK DIAGRAM
5 H
Positive Input
2 F
Positive Output
Inhibit
PWM Controller IC
ID Limit Ref.
Input Common
Output Common
DC/DC CONVERTERS
PIN OUT Single Output (Except MHF+2828S) Inhibit No connection Output Common Positive Output Sync Case Ground Input Common Positive Input MHF+2828S Inhibit Positive Output (See note 1, below) Output Common Sync Case Ground Input Common Positive Input Dual Output Inhibit Positive Output Output Common Negative Output Sync Case Ground Input Common Positive Input
1. Pin 3 of MHF+2828S will provide 14 Vout referenced to output common (pin 4). 2. If Sync is not used, pin 5 should be connected to input common.
STANDARD MICROCIRCUIT DRAWING (SMD) IN PROCESS 5962-9213901HXC IN PROCESS 5962-9166401HXC 5962-9160101HXC 5962-9689801HXC 5962-9555901HXC 5962-9214401HXC 5962-9161401HXC
MHF+ SIMILAR PART MHF+283R3S/883 MHF+2805S/883 MHF+285R2S/883 MHF+2812S/883 MHF+2815S/883 MHF+2828S/883 MHF+2805D/883 MHF+2812D/883 MHF+2815D/883
Flanged SMDs have the suffix HZC instead of HXC. For exact specifications for an SMD product, refer to the SMD drawing. Call your Interpoint representative for status on the MHF+ SMD releases which are in process. SMDs can be downloaded from http://www.dscc.dla.mil/programs/smcr
DC/DC CONVERTERS
90 90 16V 80 80 90
Typical Performance Curves: 25C Tc , 28 VDC Vin, 100% load, free run, unless otherwise specified.
80
16V
16V
EFFICIENCY (%)
EFFICIENCY (%)
70 40V 28V 60
70 40V 60
EFFICIENCY (%)
28V
70 40V 60 28V
50
50
50
40
10
12
40
10
12
14 15
40
10
12
14 15
MHF+2805S EFFICIENCY
MHF+2812S EFFICIENCY
MHF+2815S EFFICIENCY
FIGURE 3
FIGURE 4
FIGURE 5
90 16V 80
90 16V 80
90 16V 80
EFFICIENCY (%)
EFFICIENCY (%)
EFFICIENCY (%)
70 40V 60 28V
70 40V 60 28V 50
70 40V 60 28V 50
50
40
40 2 4 6 8 10 12
40 2 4 6 8 10 12 14 15
10
12
14
MHF+2805D EFFICIENCY
MHF+2812D EFFICIENCY
MHF+2815D EFFICIENCY
FIGURE 6
FIGURE 7
FIGURE 8
0 10
ATTENUATION (dB)
500mV/div.
VOUT
100% to 50%
100mV/div.
50% to 100%
20V/div.
VIN
FREQUENCY (kHz)
FIGURE 9
FIGURE 10
FIGURE 11
DC/DC CONVERTERS
Typical Performance Curves: 25C Tc , 28 VDC Vin, 100% load, free run, unless otherwise specified.
20V/div.
100% to 10%
100mV/div.
200mV/div. 20V/div.
POUT= 12W
VIN
+VOUT
10% to 100%
1V/div.
VOUT
VIN
2 ms/div
FIGURE 12
FIGURE 13
FIGURE 14
100% to 50%
PO= 7.5 W
100mV/div.
100mV/div.
5V/div.
+VOUT
20% to 100%
20V/div.
50s/div 20% 100% MHF+2815D +VOUT STEP LOAD RESPONSE
50% to 100%
VIN
2 ms/div
FIGURE 15
FIGURE 16
FIGURE 17
10
10
8 6
16 MHF+2805S&D
5 2812D 2815D 0
4 2 0 2 4 6 8 10 20
15
14
5 2805D
13
MHF+2812S&D MHF+2815S&D
10
20
40
60
80
100
10
12 10
11
12
13
14
15
POSITIVE OUTPUT LOAD (% OF TOTAL LOAD) VOUT WITH SHIFT IN LOAD BALANCE
CROSS REGULATION
OUTPUT LOAD (%) COND. A: 50% LOAD +V; 50% to 10% V COND. B: 50% LOAD V; 50% to 10% +V
FIGURE 18
FIGURE 19
FIGURE 20
DC/DC CONVERTERS
Squared corner and dot on top of case indicate pin one.
Materials Header Cold Rolled Steel/Nickel/Gold Cover Kovar/Nickel (SMHF Series Cold Rolled Steel/Nickel/Gold) Pins #52 alloy/Gold compression glass seal Case dimensions in inches (mm) Tolerance 0.005 (0.13) for three decimal places 0.01 (0.3) for two decimal places unless otherwise specified CAUTION Heat from reflow or wave soldering may damage the device. Solder pins individually with heat application not exceeding 300C for 10 seconds per pin.
BOTTOM VIEW CASE E1 MHF+ Series Single and Dual: Screening Standard, ES, or 883
Seam Seal Projection Weld Squared corner and dot on top of case indicate pin one.
0.960 (24.38) 0.030 dia. (0.76)
0.160 (4.06) 0.000 0.000 0.000 0.000 0.330 max (8.38) 0.25 (6.35) 0.330 max (8.38) 0.25 (6.35)
0.205 (5.21)
Note: Although every effort has been made to render the case drawings at actual size, variations in the printing process may cause some distortion. Please refer to the numerical dimensions for accuracy.
DC/DC CONVERTERS
Materials Header Cold Rolled Steel/Nickel/Gold Cover MHF+ Series and FMH Filter Kovar/Nickel SMHF Cold Rolled Steel/Nickel Pins #52 alloy (all cases) compression glass seal Case dimensions in inches (mm) Tolerance 0.005 (0.13) for three decimal places 0.01 (0.2) for two decimal places unless otherwise specified CAUTION Heat from reflow or wave soldering may damage the device. Solder pins individually with heat application not exceeding 300C for 10 seconds per pin.
CASE G BOTTOM VIEW Flanged package See Figure 24 for pin configuration
10
DC/DC CONVERTERS
BOTTOM VIEW CASE G1
Flanged cases: Designator "F" required in Case Option position of model number MHF+ Series Single and Dual: Screening Standard, ES, or 883
Seam Seal Projection Weld Squared corner and dot on top of case indicate pin one.
0.960 (24.38) 0.030 dia. (0.76)
0.560 (14.22) 8 7 6
0.160 (4.06) 0.000 0.000 0.000 0.330 max. (8.38) 0.330 max. (8.38) 0.25 (6.35) 0.25 (6.35) 0.140 (3.56) 0.000
0.205 (5.21)
0.505 (12.83)
0.705 (17.91)
0.905 (22.99)
1.105 (28.07)
1.590 (40.39)
11
DC/DC CONVERTERS
TABLE 1: ENVIRONMENTAL SCREENING
STANDARD
/ES
yes
yes
yes
no no
no yes
yes no
no no
no yes
yes no
no no
no yes
yes no
FINAL ELECTRICAL TEST MIL-PRF-38534, Group A Subgroups 1 through 6: -55C, +25C, +125C Subgroups 1 and 4: +25C case HERMETICITY TESTING Fine Leak, Method 1014, Cond. A Gross Leak, Method 1014, Cond. C Gross Leak, Dip (1 x 10-3) FINAL VISUAL INSPECTION Method 2009 yes yes yes no no yes yes yes no yes yes no no yes no yes yes no
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534. *883 products are built with element evaluated components and are 100% tested and guaranteed over the full military temperature range of 55C to +125C.
Contact Information: Interpoint Headquarters USA Phone: 1-800-822-8782 +425-882-3100 Email: power@intp.com
www.interpoint.com Interpoint UK Phone: +44-1252-815511 Email: poweruk@intp.com Interpoint France Phone: +33-134285455 Email: powerfr@intp.com
12
21621-001-DTS Rev B This revision supercedes all previous releases. All technical information is believed to be accurate, but no responsibility is assumed for errors or omissions. Interpoint reserves the right to make changes in products or specifications without notice. MHF+ Series is a trademark of Interpoint. Copyright 1999-2000 Interpoint. All rights reserved.
FEATURES
55 to +125C operation 16 to 48 VDC input Fully Isolated Optocoupler feedback Fixed frequency 450 kHz Topology Current Mode Flyback Transient protection 80 V/120 ms Inhibit and sync functions Indefinite short circuit protection Undervoltage lockout Up to 76% efficiency
Size (max.): Non flanged, case E2, 1.460 x 1.130 x 0.330 inches (37.08 x 28.70 x 8.38 mm) Flanged , case G2, 2.005 x 1.130 x 0.330 inches (50.93 x 28.70 x 8.38 mm) See Figures 13 - 16 for dimensions. Weight: 32 grams maximum. Screening: Standard, ES, or 883 (Class H). See Table 1 for screening options.
DESCRIPTION
Interpoints MHF+ Series Triple DC/DC converters provide a wide input voltage range of 16 to 48 VDC delivering 15 watts of total output power with output voltages of +5 and 12 or +5 and 15 VDC. The main output, +5 VDC, will supply up to 7.5 watts and the auxiliaries will supply up to 7.5 watts of combined power. Full power operation at -55 C to +125C plus the ability to withstand transients of up to 80 V for up to 120 milliseconds make these converters an ideal choice for your high reliability systems.
SYNCHRONIZATION
To synchronize the converters switching frequency to a system clock apply the clock signal to the sync terminal (pin 7). When multiple converters are powered from a single power source, asynchronous (free run) operation will result in lower peak noise for common spectral peaks, but synchronous operation will eliminate any possibility of interference frequencies in the low audio band. Source impedance of the signal should be less than 100 ohms and the transition time should be less than 100 nanoseconds. The capacitively coupled sync input will synchronize on a differential signal of as low as 4 volts to as high as 10 volts. If the sync function is not used, the terminal should be left open.
CONVERTER DESIGN
MHF+ Triple Series of DC/DC converters incorporate dual-phase, phase-shifted technology with a continuous flyback topology. This design eliminates a minimum load requirement on the main output and eliminates cross regulation effects between the main output voltage and the auxiliary output voltages. The phase-shifted design offers a further benefit in reduced input and output ripple.
INHIBIT FUNCTION
An open collector, TTL compatible, inhibit terminal (pin 1) provides shut-down and start-up control. Applying a logic level low (<0.8 V), referenced to input common, will disable the output of the converter. When inhibited input current is reduced to 5 mA or less and there is no generation of switching noise. The inhibit terminal typically sinks 3 mA when the converter is inhibited. Leaving the terminal open or pulling it high will enable the converter. Use an open collector interface for logic high voltages of up to 11 volts. (Refer to Figure 2 for a connection diagram.) An open collector interface is not required if the logic high is in excess of the open circuit voltage of the inhibit terminal, 11 volts, but less than 40 volts.
PACKAGING
MHF+ Triple converters are packaged in hermetically sealed metal cases. MHF+ Triple converters can be purchased in a flanged or non-flanged case. The flanged option provides increased heat dissipation and also provides greater stability when mechanically secured.
DC/DC CONVERTERS
SYNC AND INHIBIT
Sync 400 to 600 kHz Duty cycle 40% to 60% Logic low 0.8 V max Logic high 4.5 V min, 10.0 V max If not used, leave unconnected Referenced to input common Inhibit: TTL Open Collector Logic low (output disabled) Logic low voltage 0.8 V max Inhibit pin current 3.0 typ, 5.0 max Referenced to input common Logic high (output enabled) Open collector Unconnected or 11 to 40 V
TYPICAL CHARACTERISTICS
Output Voltage Temperature Coefficient 150 ppm/C typical Current Limit 130% typical Isolation 100 megohm minimum at 500 V Conversion Frequency Free run 375 minimum, 500 kHz maximum External sync range 400 to 600 kHz Inhibit Pin Voltage (unit enabled) 10 V typical
POSITIVE INPUT
0
FEEDBACK ISOLATOR
+5 OUTPUT
PWM CM CONTROLLER
+ AUX. OUTPUT
SYNC
PWM CM CONTROLLER
180
AUX. OUTPUT
DC/DC CONVERTERS
MHF+28512T PARAMETER OUTPUT VOLTAGE CONDITION MAIN + AUXILIARY AUXILIARY OUTPUT CURRENT1 MAIN + AUXILIARY AUXILIARY TOTAL OUTPUT POWER2 MAIN + AUXILIARY AUXILIARY TOTAL OUTPUT RIPPLE VOLTAGE LINE REGULATION3 VIN = MIN. TO MAX. LOAD REGULATION3, 4 CROSS REGULATION5 INPUT VOLTAGE 10 kHz to 2 MHz 10 kHz to 2 MHz MAIN AUXILIARY MAIN AUXILIARY AUXILIARY CONTINUOUS TRANSIENT 120 ms INPUT CURRENT NO LOAD3 FULL LOAD INHIBITED3 INPUT RIPPLE CURRENT EFFICIENCY LOAD FAULT6 POWER DISSIPATION MAIN3 STEP LOAD RESPONSE3, 7, 8 AUXILIARY TRANSIENT MAIN AUXILIARY RECOVERY MAIN RECOVERY AUX. DELAY EACH OUTPUT 5 2 10 12 12 850 750 8 3 25 10 kHz to 10 MHz MAIN AUXILIARY MIN 4.95 11.64 11.64 0 16 74 TYP 5.0 12.0 12.0 20 30 25 120 25 120 28 20 705 3 20 76 MAX 5.05 12.36 12.36 1.5 0.416 0.416 2.125 7.5 5 5 15 75 90 75 240 60 240 1200 48 80 35 724 5 50 MIN 4.925 14.55 14.55 0 16 74
Electrical Characteristics: 25C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
mV pk ms ms
START-UP3,
Notes 1. The sum of the 12 volt auxiliary output currents may not exceed 625 mA. The sum of the 15 volt auxiliary output currents may not exceed 500 mA. 2. The sum of the auxiliary output power may not exceed 7.5 watts. 3. Case temperature 55C to +125C. 4. Load regulation for the +5 is specified at 0.0 to 1.5 A with the aux. both held at 3.76 W (313 mA for the 12, 250 mA for the 15). Load regulation for the aux. is specified as both aux. from 0.0 to 3.76 W (313 mA for 12, 250 mA for 15) at the same time with the +5 held at 1.5 A.
5. Cross regulation only occurs between the two auxiliaries and is measured on aux. +5 is held constant at 1.0 A. Cross regulation is specified for two conditions: Negative aux.= 3.76 W; positive aux.= 0.37 W to 3.76 W. Negative aux. = 0.37 W to 3.76 W; positive aux. = 3.76 W. 6. Load fault = <0.05 . 7. Transition time is 2 10 s. 8. Time to settle to within 1% of Vout final value.
DC/DC CONVERTERS
CONNECTION DIAGRAMS
MHF+ Triple
POSITIVE INPUT
9
10 k
INHIBIT
1N4148 2N3501
200 pF
10 K 3.9 K
INPUT COMMON
+5 Output 2 + Aux. Output 4 Output Common 3 Aux. Output 5 Aux. Load + Aux. Load
+5 Load
If the sync terminal ([pin 7) is not used, it must be left floating. The ac coupling shown will prevent sync signal failure.
Positive Input
Positive Output
Positive Input
28V
MHF+ TRIPLE
Input Common 6
Chassis Ground
*The case ground connection should be as low an impedance as possible to minimize EMI. Direct contact of baseplate to chassis ground provides the lowest impedance.
DC/DC CONVERTERS
PIN OUT Pin 1 2 3 4 5 6 7 8 9 Description Inhibit Main (+5 V) Output Output Common Positive Auxiliary Output Negative Auxiliary Output Case Ground Sync In Input Common Positive Input
SMD NUMBERS
STANDARD MICROCIRCUIT DRAWING (SMD) 5962-9560101HXC 5962-9560201HXC MHF+ SIMILAR PART MHF+28512T/883 MHF+28515T/883
Flanged SMDs have the suffix HZC instead of HXC. For exact specifications for an SMD product, refer to the SMD drawing. SMDs can be downloaded from http://www.dscc.dla.mil/programs/smcr
DC/DC CONVERTERS
80 75 EFFICIENCY
200 mV / div.
Typical Performance Curves: 25C Tc , 28 VDC Vin, 100% load, free run, unless otherwise specified.
16 V
5 VDC
28 V 70 65 60 55 48 V
70 65 60 55
28 V 48 V
500 mV / div.
10
12
14
16
10
12
14
16
MHF+28512T EFFICIENCY
MHF+28515T EFFICIENCY
FIGURE 6
FIGURE 7
FIGURE 8
10 V / div.
10 V / div.
10 V / div.
VIN
VIN
VIN
+12 VDC
+5 GND 5 ms / div.
+5 GND 5 ms / div.
12 VDC
5 ms / div.
FIGURE 9
11.5 11 INPUT VOLTAGE 10.5 10 MHF+28512T 9.5 9 8.5 2 4 6 8 10 12 14 16 MAXIMUM OUTPUT POWER (W) MHF+28515T
FIGURE 10
FIGURE 11
FIGURE 12
DC/DC CONVERTERS
Materials Header Cold Rolled Steel/Nickel/Gold Cover Kovar/Nickel (SMHF Series Cold Rolled Steel/Nickel/Gold) Pins #52 alloy/Gold compression glass seal Case dimensions in inches (mm) Tolerance 0.005 (0.13) for three decimal places 0.01 (0.3) for two decimal places unless otherwise specified CAUTION Heat from reflow or wave soldering may damage the device. Solder pins individually with heat application not exceeding 300C for 10 seconds per pin.
BOTTOM VIEW CASE E2 MHF+ Series Triple: Screening Standard, ES, or 883
Seam Seal Projection Weld Squared corner and dot on top of case indicate pin one.
0.960 (24.38)
0.160 (4.06) 0.000 0.330 max (8.38) 0.25 (6.35) 0.25 (6.35) 0.330 max (8.38) 0.000 0.000 0.000
0.205 (5.21)
Note: Although every effort has been made to render the case drawings at actual size, variations in the printing process may cause some distortion. Please refer to the numerical dimensions for accuracy.
DC/DC CONVERTERS
Squared corner and dot on top of case indicate pin one.
CASE G BOTTOM VIEW Flanged package See Figure 16 for pin configuration
Materials Header Cold Rolled Steel/Nickel/Gold Cover MHF+ Series and FMH Filter Kovar/Nickel Pins #52 alloy (all cases) compression glass seal Case dimensions in inches (mm) Tolerance 0.005 (0.13) for three decimal places 0.01 (0.2) for two decimal places unless otherwise specified
CAUTION Heat from reflow or wave soldering may damage the device. Solder pins individually with heat application not exceeding 300C for 10 seconds per pin.
BOTTOM VIEW CASE G2 Flanged case: Designator (F) required in Case Option position of model number. MHF+ Series Triple: Screening Standard, ES, or 883
Seam Seal Projection Weld Squared corner and dot on top of case indicate pin one.
0.960 (24.38)
5
0.128 dia (3.25)
0.560 (14.22)
0.160 (4.06) 0.000 0.330 max. (8.38) 0.330 max. (8.38) 0.25 (6.35) 0.25 (6.35) 0.140 (3.56) 0.000 0.000 0.000
0.505 (12.83)
0.705 (17.91)
0.905 (22.99)
1.105 (28.07)
0.205 (5.21)
Note: Although every effort has been made to render the case drawings at actual size, variations in the printing process may cause some distortion. Please refer to the numerical dimensions for accuracy.
1.590 (40.39)
DC/DC CONVERTERS
TABLE 1: ENVIRONMENTAL SCREENING
STANDARD /ES /883 (Class H)*
yes
yes
yes
no no
no yes
yes no
no no
no yes
yes no
no no
no yes
yes no
FINAL ELECTRICAL TEST MIL-PRF-38534, Group A Subgroups 1 through 6: -55C, +25C, +125C Subgroups 1 and 4: +25C case HERMETICITY TESTING Fine Leak, Method 1014, Cond. A Gross Leak, Method 1014, Cond. C Gross Leak, Dip (1 x 10-3) FINAL VISUAL INSPECTION Method 2009 yes yes yes no no yes yes yes no yes yes no no yes no yes yes no
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534. *883 products are built with element evaluated components and are 100% tested and guaranteed over the full military temperature range of 55C to +125C.
Interpoint Headquarters USA Phone: 1-800-822-8782 +425-882-3100 Email: power@intp.com Interpoint UK Phone: +44-1252-815511 Email: poweruk@intp.com
21623-002-DTS Rev B This revision supercedes all previous releases. All technical information is believed to be accurate, but no responsibility is assumed for errors or omissions. Interpoint reserves the right to make changes in products or specifications without notice. MHF+ Series is a trademark of Interpoint. Copyright 1995 - 1999 Interpoint. All rights reserved.