Form CIDB IBS Score M1 (rev.
2010)
                                        CALCULATION FOR IBS SCORE
                                                                                   For Office Use
                                                             Project Registration No:
                                                             Project Category:
Project Name:                                                Contract Value: RM18 million
IBS SCORE for MEREKABENTUK, MEMBINA DAN
MENYIAPKAN UNIT RUMAH TERES DAN
Contractor Name:                                             Developer / Owner Name :
Architect Consultant :                                       Civil & Structural Engineer Consultant Name :
ARCHITECTS                                                   PERUNDING CSS
                                                             No.17-3,Jalan OP 1/2,
                                                             One Puchong Business Park,
                                                             47100 Puchong,Selangor Darul Ehsan.
      List of Submitted Drawings
 1)                                                           6)
 2)                                                           7)
 3)                                                           8)
 4)                                                           9)
 5)                                                          10)
We hereby declare that the information given and the IBS Score submitted herewith is true and complete.
The total IBS Score for the proposed building / project is         70.33
Date : 20/04/2017                                                  Name & Signature of Qualified Person
                               CALCULATIONS OF OVERALL IBS SCORE
PROJECT DETAILS
Project Name : CADANGAN PEMBANGUNAN BLOK TERES 2 TINGKAT ( UNIT) DI ATAS LOT
Type / Block No:                 Terrace House             Total no of Units / Blocks:            1
Contract Value :                 RM mil
Category of Building
            Residential (Landed)                     Industrial                         Commercial
             Residential (high rise)                  Institutional                      Others
For mixed decelopment, please indicate the area of the category:
Residential (landed)                   -   m2         Industrial                -        m2
Residential (high rise)                -   m2         Institutional             -        m2
Commercial                             -   m2         Others                    -        m2
           IBS SCORE for MEREKABENTUK, MEMBINA DAN MENYIAPKAN UNIT RUMAH TERES
Source: Manual for IBS Content Scoring System (IBS Score) - ISBN 983-2724-30-9
   IBS Score = Score for Structural Systems + Score for Wall System + Score for Other Simplified Construction
                                                    System
                                 50[(Qs/Qst)xFs] + 30[(Qw/Qwt)xFw] + S
where :    Qs          Construction area of a structural system
           Qst         Total construction area of building
           Fs          IBS Factor for structural system for Table 1
           Qw          Length of wall system (external or internal wall)
           Qwt         Total wall length (external or internal wall length)
           Fw          IBS Factor for wall system from Table 2
           S           IBS Score for other simplified construction solutions from Table 3
Calculation for IBS Score for a project
Building : Double Storey Terrace
                                             2 storey
1) Construction Area
i) Ground Floor                             72 m2       (for 1 unit)
ii) First Floor                             72 m2       (for 1 unit)
ii) Roof area                               72 m2       (for 1 unit)
iii) Total units                             1
Total Construction Area                   216 m2
2) Structural Systems :
Wall                 Load Bearing Precast Wall System
Roof                 Prefabricated steel roof truss
3) Wall System:
Wall area
i) Internal Precast wall panel                                                    45.2 m / unit
ii)External Precast wall panel                                                    71.3 m / unit
Total Wall Area                                                                  116.5 m
4) Other Simplified Construction Solutions
Beams                                        76% complies to MS1064 Part 10 : 2001
Columns                                      76% complies to MS1064 Part 10 : 2001
Wall                                         76% complies to MS1064 Part 10 : 2001
Slabs                                        76% complies to MS1064 Part 10 : 2001
Windows                                      76% complies to MS1054 Part 5 : 2001
Doors                                        76% complies to MS1054 Part 4 : 2001
a) For building more than 2 storeys
i)Repetition of floor to floor height                          0%
ii)vertical repetition of structure layout                     0%
b) For building 1 or 2 storeys
i)Horizontal repetition of structural layout                  70%
Other Prefab components:-
Prefab Staircase                                               0%
                     ELEMENTS                       Area (m2)    IBS Factor    Coverage %        IBS Score
Part 1 : Structural Systems                            (a)          (b)       (a) / (a) =(c)   (b) x (c) x 50
1.1 Ground Floor
In-situ column & beams using reusable system             72         0.5            33%              8.33
formwork + In-situ concrete using reusable system
formwork
1.2 First Floor
In-situ column & beams using reusable system
formwork + In-situ concrete using reusable system        72         0.5            33%              8.33
formwork
1.6 Roof
Prefabricated roof truss                                 72         1.0            33%             16.67
Total Area                                             216                         100%
Subtotal for Structural System (maximum 50 points) (A)                                             33.33
                     ELEMENTS                       Length (m)   IBS Factor    Coverage %        IBS Score
Part 2 : Wall Systems                                  (a)          (b)       (a) / (a) =(c)   (b) x (c) x 20
Internal Wall
i)In-situ concrete with reusable system formwork       45.2         0.5            39%              3.88
External Wall
i)In-situ concrete with reusable system formwork       71.3         0.5            61%              6.12
Total Area                                            116.5                        100%
Subtotal for Wall System (maximum 20 points) (B)                                                   10.00
Part 3 : Other Simplified Construction Solutions
                                                                 USAGE
                                                                                  % USAGE FOR
                   Elements                       UNIT                            THIS PROJECT
                                                                                                 IBS SCORE
                                                         50%<X<75%   75%<X<100%
1.0 Utilisation of standardised
components based on MS 1064
a) Beams sizes complies to MS 1064 Part
10 : 2001                                         Nos        2           4            76%            4
b) Columns sizes complies to MS 1064 Part
10 : 2001                                 Nos                2           4            76%            4
c) Walls sizes complies to MS 1064 Part 10 :
2001                                         m               2           4            76%            4
d) Slabs sizes complies to MS 1064 Part 10 :
2001                                         m2              2           4            76%            4
e) Windows sizes complies to MS 1064 Part
10 : 2001                                 Nos                2           4            76%            4
2001                                              Nos        2           4            76%            4
2.0 Repetition of Structural Layout
a) For building more than 2 storeys
i) Repetition of floor to floor height            Nos        1           2            N/A            0
ii) vertical repetition of structure layout       Nos        1           2            N/A            0
iii) Horizontal repetition of structural layout   Nos        1           2            N/A            0
b) For building 1 or 2 storeys
i)Horizontal repetition of structural layout      Nos        3           6            70%            3
Subtotal for other simplified construction solution (maximum 30 points) ( C )                      27.0
TOTAL IBS Score (maximum 100 points) ( A + B + C )                                                 70.3
                                       IBS SCORE for Cadangan Pembinaan
IBS Content Score for the project can be calculated using the following formula:
                 IBS Score for project = {IBS Score of building x Qst (building) / Qst(project)}
                                                                 Construction               IBS             IBS
Item                           Building                                       Coverage
                                                                  Area (m 2)           Score(building) Score(project)
  1    Double Storey Terrace                                         216         1.000              70     70.33
       Total                                                         216          1.0                      70.33
       Therefore, the IBS score for the whole of the development project is                    70.33