Ref: SKE/SVSD/01/HT/2017                                                                          Date: 13/09/201
To
The Executive Officer,
Sri Venkatreswara Swami Vari Devasthanam
Dwaraka Tirumala,
West Godavari Dt. , A.P.
Dear Sir,
       Subject: Offer for11KV Indoor air insulated VCB panel - reg.
       We thank you very much for your valuable enquiry and are pleased to submit our offer for
 the same. Please find enclosed the following with our offer:
 1. Bill of Material.
 2. Price Schedule.
 3. Terms and Conditions
 4. Make List
 We trust the above is in line with your requirement and you find our offer complete and competitive.
 In case there are any clarifications kindly advise us so that the same could be replied to you absolute
 satisfaction.
 Thanking You Sir
 Yours Truly
 For Sri Kumar Enterprises
 Amarendra
 Mob:9490106127
 ACB * VCB* OCB* VFD * HV/LV Motors * HV/LV CABLES * POWER QUALITY PRODUCTS * LIGHTING* ENERGY
        MANAGEMENT
      BREAKING CAPACITY : 25kA for 1 Sec
      INSTALLATION: INDOOR
      Equipment Type: PIX ROF
      DEGREE OF PROTECTION: IP4X
      Bill of Materials for 11 KV Switchboard.
                                                                                       Outgoing   Outgoing   Outgoing
                                                                                         CB-1       CB-2       CB-3
Sr.
No.                                        DESCRIPTION                       Incomer    Trafo.     Trafo.
        RATING :                                                               1250A    1250A      1250A      1250A
        QTY:                                                                     1        1          1          1
A       MOVING PORTION :
A1      11 KV, 1250A, 25 KA for 1 Sec. VCB                                       1        1           1         1
A2      1250A Sheet Steel Enclosure with connection                              1        1           1         1
A3      PVC sleeved 2500A Amps AL busbars                                        1        1           1         1
B       CT AND PT DETAILS :
        2 Core CT, 1000/5-5 A, 5P20 FOR PROTECTION, AND CLASS 0.5
B1      FOR METERING, 15 VA                                                      3        0           0         0
        2 Core CT, 600/5-5 A, 5P20 FOR PROTECTION, AND CLASS 1.0 FOR
B2      METERING, 15 VA                                                          0        3           0         3
        2 Core CT, 200/5-5 A, 5P20 FOR PROTECTION, AND CLASS 1.0 FOR
B2      METERING, 15 VA                                                          0        0           3         0
B3      PT 11 KV/110V AND CLASS 1.0 ,100VA/phase                                 1        1           1         1
C       BREAKER PANEL INDICATION LAMPS :
C1      Breaker On / Off / Trip / Trip Circuit Healthy / Spring Charge etc       8        8           8         8
C2      R/Y/B                                                                    3        3           3         3
D       SWITCHES AND OTHER ACCESSORIES :
D1      DC ON/OFF Switch                                                         1        1           1         1
D2      AC ON/OFF Switch                                                         1        1           1         1
D3      Heater with heater switch & thermostat                                   1        1           1         1
D4      Cubicle illumination lamp                                                1        1           1         1
D5      15A, 230V, 3 pin plug plug & socket                                      1        1           1         1
D6      MCB                                                                      6        6           6         6
D7      Local Remote Switch                                                      1        1           1         1
D8      T-N-C Switch                                                             1        1           1         1
D9      Auxiliary contactor (4NO + 4NC)                                          1        1           1         1
      ACB * VCB* OCB* VFD * HV/LV Motors * HV/LV CABLES * POWER QUALITY PRODUCTS * LIGHTING* ENERGY
             MANAGEMENT
D10      14 Window Annunciator                                                 1            1           1     1
D11      Hooter                                                                1            1           1     1
D12      Surge diverter                                                        3            3           3     3
 E       METERS & TRANSDUCERS :
 E1      MFM Conserv EM6400NG RS                                               1            1           1     1
 E2      Ammeter with SS                                                       1            1           1     1
 E3      Voltmeter with SS                                                     1            1           1     1
 E4      Power factor meter                                                    1            1           1     1
 E5      Mega Watt meter                                                       1            1           1     1
  F      RELAYS :
F1       Numerical Relay Micom P111 with MODBUS protocol                       1            1           1     1
F2       VAX31_Trip Circuit Supervision Relay                                  1            1           1     1
F3       VAA33_Transformer Aux. Relay                                          1            2           2     2
F4       VAJH13_Master Trip Relay                                              1            1           1     1
F5       TIMEE                                                                 1            1           1     1
F6       VAGM 22/VAG-11 Over Voltage                                           1            1           1     1
                                                       Price Schedule:
        Sl. No.               Description           Qty Unit Ex-works Price(INR) Total Ex-works Price(INR)
                  Supply and Commissioning of
                  Schneider Make 11kV HT VCB Panels
          1       as per enclosed BOM                 4                 7,50,000                  30,00,000
      Note:
      Terms and Conditions enclosed
      ACB * VCB* OCB* VFD * HV/LV Motors * HV/LV CABLES * POWER QUALITY PRODUCTS * LIGHTING* ENERGY
             MANAGEMENT
                                           TERMS AND CONDITIONS
Article - 1: Scope
The scope of work is restricted to supply, packing, forwarding of Equipments as per agreed BOQ, drawings
and technical specifications.
Article - 2: Offer Validity
Sellers Offer is valid for 30 days from the date of the Offer after expiry of which it will be subject to
confirmation/ revision, if any from Sellers end.
Article  3: Taxes, Duties and Statutory Variations
All taxes and duties shall be extra at actual. All sort of statutory variation including change, addition, deletion,
abolition, repeal or reclassification due to change in Law and/ or directive of authorized agency shall be
exclusively to the Buyers account.
Article - 4: Terms of Payment
     Twenty Percent (40%) of Contract Price as interest free advance along with purchase order.
     Sixty Percent (60%) with 100% duties and taxes against proforma invoice after inspection before dispatch.
Article - 5: Testing Charges/ Inspection
The necessary Routine /Acceptance Tests as per the latest IS/IEC with its latest amendments will be carried
out at Schneider works.
We shall arrange to give you ONE-WEEK advance intimation for deputing your representative to carryout the
necessary pre- dispatch inspection of the equipment(s) if so desired by you. Expenses incurred on account of
Inspection (i.e. fooding, lodging and logistics) for the product / equipment shall not be in the scope of
Schneider Electric Infrastructure Limited.
All routine tests will be done as per IS. No special type test has been offered. All inspection related charges
shall like boarding, travel shall into customer scope.
Article - 6: Completion Period
The Supplier shall complete the ex-works delivery in 12 to14 Weeks from the date of drawing
approval/manufacturing clearance.
Article - 7: Drawing submission schedule
Document / Drawing for approval shall be submitted within 2-3 weeks from the date receipt LOI / PO or along
with the advance
Article - 8: Overall Limitation to Liability
Notwithstanding anything in the Contract to the contrary and to the extent permitted by applicable law, (a) in
no event shall either Party, its officers, directors, or employees be liable for any form of incidental,
consequential, indirect, special or punitive damages of any kind, or for loss of revenue or profits, loss of
business, loss of information or data, or other financial loss, whether such damages arise in contract, tort or
otherwise, irrespective of fault, negligence or strict liability or whether such Party has been advised in advance
of the possibility of such damages; and (b) the maximum liability of the Seller for any and all claims, losses,
    ACB * VCB* OCB* VFD * HV/LV Motors * HV/LV CABLES * POWER QUALITY PRODUCTS * LIGHTING* ENERGY MANAGEMENT
damages, costs and expenses arising from or on connection with this Contract shall not exceed the amounts
actually received by the Seller under this Contract.
Article - 9: Warranty
We warranty the panels against faulty design, bad quality of material, bad workmanship for a period of 12
months from the date of commissioning OR 18 months from the date of dispatch, whichever is earlier.
Article - 10: Freight and Transit Insurance
The FREIGHT and TRANSIT INSURANCE shall be extra at actual.
Article - 11: Supervision of Erection and Commissioning
Advance intimation of at least 7-10 days is required for supervision at Site. Supervision charges shall be Rs
15000/- per man day. Travel expense (to and fro) and stay charges at actual and to be borne by the
purchaser.
The above terms and conditions form integral part of our complete offer together with technical and price
parts.
 ACB * VCB* OCB* VFD * HV/LV Motors * HV/LV CABLES * POWER QUALITY PRODUCTS * LIGHTING* ENERGY MANAGEMENT
                            Make List for HT VCB Panels
Current Transformer               Schneider
Potential Transformer             Schneider
Numerical Relays                  Alstom, Schneider, C&S, ER
Transformer Differential Relays    ABB, ER, Schneider, Alstom
Auxiliary relays                   ABB, Weidmullar, Jyoti, Alstom
Electro-mechanical Relays          Alstom, ABB, ER
Timers                             IP 4X
Conventional Indicating Meters Rishabh, AE, MECO
Digital Indicating Meters          Conzerv, Rishabh, Secure
Multi Function Meters              Conzerv, Rishabh, SATEK, Secure, L&T
TVM with 0.2S accuracy Class       Secure, L&T
MCBs                               Schneider , Legrand, Siemens
Breaker Control Switch             Switron, Recom, Kaycee
Local Remote selector switch       Switron, Recom, Kaycee
Rotary / Toggle switch             Switron, Recom, Kaycee
Fuse                               Cooper Bussman, GEPC
Fuse base                          Cooper Bussman, GEPC, Siemens
Indicating lamps                   Teknic, Essen Denkey/Vaishno, STS, Siemens
Push Buttons                       Teknic, Essen Denkey/Vaishno, STS, Siemens
Auxiliary / Power contactors       Schneider, Siemens, L&T
Surge arrestors                    Oblum, Tyco
Annunciator                        Alan, EAPL, Minilec,
TB                                 Elmex, Connect well  screw type
Transducer                         Rishabh, Secure, AE, Elster
Wire                               KEI , Relicab, Polycab
FBT / ABT Panels                   ER, Artek
Busduct                            Popular Switchgear, Entraco, United Electric
3 Pin socket                       Anchor
ACB * VCB* OCB* VFD * HV/LV Motors * HV/LV CABLES * POWER QUALITY PRODUCTS * LIGHTING* ENERGY MANAGEMENT